Fast maximum entropy approximation in SPECT using the RBI-MAP algorithm.

In this work, we present a method for approximating constrained maximum entropy (ME) reconstructions of SPECT data with modifications to a block-iterative maximum a posteriori (MAP) algorithm. Maximum likelihood (ML)-based reconstruction algorithms require some form of noise smoothing. Constrained ME provides a more formal method of noise smoothing without requiring the user to select parameters. In the context of SPECT, constrained ME seeks the minimum-information image estimate among those whose projections are a given distance from the noisy measured data, with that distance determined by the magnitude of the Poisson noise. Images that meet the distance criterion are referred to as feasible images. We find that modeling of all principal degrading factors (attenuation, detector response, and scatter) in the reconstruction is critical because feasibility is not meaningful unless the projection model is as accurate as possible. Because the constrained ME solution is the same as a MAP solution for a particular value of the MAP weighting parameter, beta, the constrained ME solution can be found with a MAP algorithm if the correct value of beta is found. We show that the RBI-MAP algorithm, if used with a dynamic scheme for estimating beta, can approximate constrained ME solutions in 20 or fewer iterations. We compare results for various methods of achieving feasible images on a simulation of Tl-201 cardiac SPECT data. Results show that the RBI-MAP ME approximation provides images and quantitative estimates close to those from a slower algorithm that gives the true ME solution. Also, we find that the ME results have higher spatial resolution and greater high-frequency noise content than a feasibility-based stopping rule, feasibility-based low-pass filtering, and a quadratic Gibbs prior with beta selected according to the feasibility criterion. We conclude that fast ME approximation is possible using either RBI-MAP with the dynamic procedure or a feasibility-based stopping rule, and that such reconstructions may be particularly useful in applications where resolution is critical.

Algorithms↗

Receiver operating characteristic evaluation of iterative reconstruction with attenuation correction in 99mTc-sestamibi myocardial SPECT images.

UNLABELLED: The purpose of this study was to evaluate differences in myocardial defect detection between 99mTc-sestamibi myocardial SPECT images reconstructed using conventional filtered backprojection (FBP) without attenuation correction (AC) and those reconstructed using maximum-likelihood expectation maximization with nonuniform attenuation correction (MLAC). METHODS: An observer study and receiver operating characteristic (ROC) curve analysis were performed using simulated 99mTc-sestamibi SPECT data from a population of 24 mathematic anthropomorphic torso phantoms, which realistically modeled a wide range of anatomic variations. The phantoms modeled male patients with a flat diaphragm, male patients with a diaphragm raised to the level of the heart, and female patients with large breasts. Transmural, cold defects with a contrast of 0.25 were simulated in the left ventricular wall for 6 locations. Noisy projection data were generated from the phantoms and included the effects of nonuniform attenuation, collimator-detector response, and scatter. The data were then reconstructed using FBP and MLAC. Images were displayed in the short- and long-axis formats, as in clinical practice. Eight observers viewed blocks of FBP and MLAC images and, for each image, indicated on a continuous rating scale the probability that a defect was present. From the rating data, FBP and MLAC ROC curves were generated, and their areas (Az) were estimated and compared. RESULTS: In general, the FBP and MLAC ROC curves did not cross and the MLAC curve showed a higher Az than did the corresponding FBP curve. For male phantoms with a flat diaphragm, the average difference in Az was 0.04 and was not statistically significant (at the P = 0.05 level) for 6 of 8 observers. For male phantoms with a raised diaphragm, the average difference in Az was 0.22 and was statistically significant for 6 of 8 observers. For female phantoms with large breasts, the average difference in Az was 0.19 and was statistically significant for all 8 observers. CONCLUSION: This study showed an improvement in defect detection in myocardial SPECT images using MLAC in comparison with images using FBP without AC, particularly for patients with large breasts or with a diaphragm raised to the level of the heart.

Breast↗

Simultaneous technetium-99m/thallium-201 SPECT imaging with model-based compensation for cross-contaminating effects.

Simultaneous acquisition of dual-isotope SPECT data offers a number of advantages over separately acquired data; however, simultaneous acquisition can result in cross-contamination between isotopes. In this work we propose and evaluate two frameworks for iterative model-based compensation of cross-contamination in dual-isotope SPECT. The methods were applied to cardiac imaging with technetium-99m-sestamibi and thallium-201, and they were compared with a subtraction-based compensation method using a cross-talk estimate obtained from an auxiliary energy window. Monte Carlo simulations were performed to carefully study aspects of bias and noise for the methods, and a torso phantom with cardiac insert was used to evaluate the performance of the methods for experimentally acquired data. The cross-talk compensation methods substantially improved lesion contrast and significantly reduced quantitative errors for simultaneously acquired data. Thallium image normalized mean square error (NMSE) was reduced from 0.522 without cross-talk compensation to as low as 0.052 with model-based cross-talk compensation. This is compared with a NMSE of 0.091 for the subtraction-based compensation method. The application of a preliminary model for cross-talk arising from lead fluorescence x-rays and collimator scatter gave promising results, and the future development of a more accurate model for collimator interactions would probably benefit simultaneous Tc/Tl imaging. Model-based compensation methods provide feasible cross-talk compensation in clinically acceptable times, and they may ultimately make simultaneous dual-isotope protocols an effective alternative for many imaging procedures.

Drug Interactions↗

Fast implementations of reconstruction-based scatter compensation in fully 3D SPECT image reconstruction.

Accurate scatter compensation in SPECT can be performed by modelling the scatter response function during the reconstruction process. This method is called reconstruction-based scatter compensation (RBSC). It has been shown that RBSC has a number of advantages over other methods of compensating for scatter, but using RBSC for fully 3D compensation has resulted in prohibitively long reconstruction times. In this work we propose two new methods that can be used in conjunction with existing methods to achieve marked reductions in RBSC reconstruction times. The first method, coarse-grid scatter modelling, significantly accelerates the scatter model by exploiting the fact that scatter is dominated by low-frequency information. The second method, intermittent RBSC, further accelerates the reconstruction process by limiting the number of iterations during which scatter is modelled. The fast implementations were evaluated using a Monte Carlo simulated experiment of the 3D MCAT phantom with 99mTc tracer, and also using experimentally acquired data with 201Tl tracer. Results indicated that these fast methods can reconstruct, with fully 3D compensation, images very similar to those obtained using standard RBSC methods, and in reconstruction times that are an order of magnitude shorter. Using these methods, fully 3D iterative reconstruction with RBSC can be performed well within the realm of clinically realistic times (under 10 minutes for 64 x 64 x 24 image reconstruction).

Humans↗

Improved estimation of the detector response function for converging beam collimators.

Converging beam collimator geometries offer improved tradeoffs between resolution and noise for single photon emission computed tomography (SPECT). The major factor limiting the resolution in SPECT is the collimator-detector response blurring. In order to compensate for this blurring it is useful to be able to calculate the collimator response function. A previous formulation presented a method for calculating the response for parallel and converging beam collimators that assumed that the shape of the holes did not change over the face of the collimator. However, cast collimators are fabricated using pins with a constant cross-section (shape perpendicular to the pin axis). As a result, due to the angulation of the pins, the holes made by these pins have shapes on the front and back faces of the collimator that change with position. This change in hole shape is especially pronounced when the angle between the collimator hole and the collimator normal is large, as is the case for half-fan-beam or short-focal-length collimators. This paper presents a derivation of a modification to the original method that accounts for the change in shape of the collimator holes. The method has been verified by comparing predicted line spread functions to experimentally measured ones for a collimator with a maximum hole angle of 35 degrees with respect to the normal. This formulation is useful for predicting the response of fan-beam collimators in the design process and for use in detector response compensation algorithms.

Equipment Design↗

Application of reconstruction-based scatter compensation to thallium-201 SPECT: implementations for reduced reconstructed image noise.

Scatter compensation in Tl-201 single photon emission computed tomography (SPECT) presents an interesting challenge because of the multiple emission energies and relatively large proportion of scattered photons. In this paper, we present a simulation study investigating reconstructed image noise levels arising from various implementations of iterative reconstruction-based scatter compensation (RBSC) in Tl-201 SPECT. A two-stage analysis was used to study single and multiple energy window implementations of reconstruction-based scatter compensation, and RBSC was compared to the upper limits on performance for other approaches to handling scatter. In the first stage, singular value decomposition of the system transfer matrix was used to analyze noise levels in a manner independent of the choice of reconstruction algorithm, providing results valid across a wide range of regularizations. In the second stage, the data were reconstructed using maximum-likelihood expectation-maximization, and the noise properties of the resultant images were analyzed. The best RBSC performance was obtained using multiple energy windows, one for each emission photopeak, and RBSC outperformed the upper limit on subtraction-based compensation methods. Implementing RBSC with the correct choice of energy window acquisition scheme is a promising method for performing scatter compensation for Tl-201 SPECT.

Phantoms, Imaging↗

Analysis of the reconstructibility and noise properties of scattered photons in 99mTc SPECT.

Since scattered photons carry degraded spatial information, scatter is typically considered a source of contamination in SPECT. However, with the advent of scatter modelling methods and reconstruction-based scatter compensation (RBSC), it may be possible to utilize scattered data in a productive manner. In this work we analyse the reconstructibility of scattered photon projection data and investigate the potential for using scattered photons to reduce the noise levels of SPECT images. We have simulated projection data for an elliptical phantom containing three cold rods in a uniform background of 99mTc activity. A variety of photopeak and scatter energy windows were formed, as well as corresponding RBSC transfer matrices. Each statistically weighted matrix was decomposed using SVD and analysed in terms of reconstructibility and noise properties. Results indicate that scattered photons contain sufficient information to reconstruct the source activity, but the scatter-only matrices are very poorly conditioned. We have also evaluated several methods of utilizing scattered events via RBSC, and compared them with other, idealized methods of handling scatter. It was found that scattered photons can be used productively when photopeak and non-photopeak data are separated through the use of multiple energy windows. The RBSC methods outperformed ideal scatter subtraction, but fell short of methods which assume perfect discrimination between scattered and primary events. The knowledge gained by this study may help guide future research and lead to better approaches to handling scatter in SPECT.

Computer Simulation↗

Scatter compensation methods in 3D iterative SPECT reconstruction: a simulation study.

Effects of different scatter compensation methods incorporated in fully 3D iterative reconstruction are investigated. The methods are: (i) the inclusion of an 'ideal scatter estimate' (ISE); (ii) like (i) but with a noiseless scatter estimate (ISE-NF); (iii) incorporation of scatter in the point spread function during iterative reconstruction ('ideal scatter model', ISM); (iv) no scatter compensation (NSC); (v) ideal scatter rejection (ISR), as can be approximated by using a camera with a perfect energy resolution. The iterative method used was an ordered subset expectation maximization (OS-EM) algorithm. A cylinder containing small cold spheres was used to calculate contrast-to-noise curves. For a brain study, global errors between reconstruction and 'true' distributions were calculated. Results show that ISR is superior to all other methods. In all cases considered, ISM is superior to ISE and performs approximately as well as (brain study) or better than (cylinder data) ISE-NF. Both ISM and ISE improve contrast-to-noise curves and reduce global errors, compared with NSC. In the case of ISE, blurring of the scatter estimate with a Gaussian kernel results in slightly reduced errors in brain studies, especially at low count levels. The optimal Gaussian kernel size is strongly dependent on the noise level.

Algorithms↗

Quantitative single-photon emission computed tomography: basics and clinical considerations.

Although quantitative single-photon emission computed tomography (SPECT) has been the goal of much research effort for a number of years, only recently has it received wide interest, especially for clinical applications. It has been increasingly recognized that the achievement of quantitative SPECT will increase the accuracy of measurements, such as dimensions of specific regions of interest, absolute amount of radioactivity, and dosimetry calculations, and substantially reduce reconstruction image artifacts and distortions, thus, greatly improving clinical diagnosis. This article provides a review of the definition of terms, major factors affecting SPECT quantitation and their degrading effects on SPECT image quality, and methods to compensate for these effects. Compensation methods include those that make certain approximations for ease of implementation and those that provide more accurate compensation by modeling the imaging process more exactly, usually at the cost of increased complexity and computational requirements. Different reconstruction and compensation methods may be compared through the use of phantom cardiac and brain SPECT studies. The clinical efficacy of the methods may be demonstrated by applying them to a clinical thallium-201 myocardial perfusion SPECT study. The results clearly demonstrate that, by modeling the imaging process and/or image degrading factors three-dimensionally, quantitative reconstruction and compensation methods provide the best image quality and quantitative accuracy. Important research efforts and developmental work being conducted currently to bring quantitative SPECT into routine clinical use are also discussed.

Humans↗

Simultaneous acquisition of emission and transmission data for improved thallium-201 cardiac SPECT imaging using a technetium-99m transmission source.

Transmission computed tomography (TCT) data provides useful complementary information to single-photon emission computed tomography (SPECT) reconstructions, especially for cardiac studies. In particular, TCT data has been used to correct for nonuniform attenuation in the chest. Typically the transmission data are acquired in a separate acquisition, but simultaneous acquisition is preferable both to save time and to avoid difficulties involved with registration. In this work, we present a technique for simultaneously acquiring 201Tl SPECT and TCT data using a 99mTc sheet source that requires only minor equipment modifications. The use of these isotopes results in cross-contamination of the emission and transmission data. We present a practical technique to compensate for this contamination using post-acquisition image processing. This technique was evaluated by performing phantom and patient studies. The resulting images compare well with data obtained from separate emission and transmission studies.

Heart↗

Quantitative myocardial perfusion SPECT.

In recent years, there has been much interest in the clinical application of attenuation compensation to myocardial perfusion single photon emission computed tomography (SPECT) with the promise that accurate quantitative images can be obtained to improve clinical diagnoses. The different attenuation compensation methods that are available create confusion and some misconceptions. Also, attenuation-compensated images reveal other image-degrading effects including collimator-detector blurring and scatter that are not apparent in uncompensated images. This article presents basic concepts of the major factors that degrade the quality and quantitative accuracy of myocardial perfusion SPECT images, and includes a discussion of the various image reconstruction and compensation methods and misconceptions and pitfalls in implementation. The differences between the various compensation methods and their performance are demonstrated. Particular emphasis is directed to an approach that promises to provide quantitative myocardial perfusion SPECT images by accurately compensating for the 3-dimensional (3-D) attenuation, collimator-detector response, and scatter effects. With advances in the computer hardware and optimized implementation techniques, quantitatively accurate and high-quality myocardial perfusion SPECT images can be obtained in clinically acceptable processing time. Examples from simulation, phantom, and patient studies are used to demonstrate the various aspects of the investigation. We conclude that quantitative myocardial perfusion SPECT, which holds great promise to improve clinical diagnosis, is an achievable goal in the near future.

Algorithms↗