Search PubMed⌕ Search

Biomedical subjects

E C Benzel

Publications and source records attributed to E C Benzel.

119 records · Page 7Linked to original sources

Operative stabilization of the posttraumatic thoracic and lumbar spine: a comparative analysis of the Harrington distraction rod and the modified Weiss spring.

To assess the efficacy of operative stabilization techniques, a retrospective study of Harrington distraction rod (HDR) and modified Weiss spring instrumentation was performed in 90 patients. An operation was performed for one or both of two indications: persistent spine instability or the presence of a neurological deficit in patients with incomplete neurological injuries and myelographic evidence of spinal cord or cauda equina compression. The lateral extracavitary operative approach to the spine for decompression and anterior interbody fusion was performed with an accompanying HDR (47 patients) or modified Weiss spring placement (43 patients). Eight HDRs failed, resulting in gross instability (17 per cent) that either resulted in further neurological injury (1 patient), further surgery (2 patients), or increased morbidity secondary to prolonged bed rest (5 patients). One Weiss spring failed, requiring further surgery (2.3 per cent). Nonsurgical complications were similar in both groups and appeared to be unrelated to the type of instrumentation utilized. The modified Weiss spring instrumentation technique, which offers a dynamic compression fixation of the spine, was clearly superior to the HDR technique, which offers a rigid distraction fixation. The biomechanics of distraction versus compression and rigid versus nonrigid spine stabilization are discussed.

Bone Wires↗

Functional recovery after decompressive operation for thoracic and lumbar spine fractures.

A series of 105 operative cases of thoracic and lumbar spine trauma is presented. All patients underwent an anterior decompression and fusion via the lateral extracavity approach with or without an accompanying posterior internal stabilization procedure (modified Weiss springs or Harrington distraction rods). All patients were allowed to plateau neurologically before reconstructive spine surgery was performed. The patient's neurological grade at the time of surgery and after recovery was assessed according to a seven-grade scale presented herein. None of the 34 patients with a motor and sensory complete myelopathy recovered any function below the level in injury. Of the 10 motor-complete patients with some sensory perception, 4 improved neurologically; however, only 1 of these improved to a state of limited ambulation. The rest remained nonambulatory. Of the 33 patients with significantly disabling incomplete motor and sensory myelopathies, 17 improved to a level of minimal neurological deficit; only 3 patients were left nonambulatory. Of the 21 patients whose physical finding demonstrated a minimal neurological deficit preoperatively, 17 recovered to a normal neurological state. Seven patients were neurologically normal preoperatively and were unchanged postoperatively. Reconstruction of the spine with an anterior decompression and an accompanying stabilization procedure, when appropriate, leads to a better neurological outcome than that expected with either a conservative, nonoperative approach or an operative posterior stabilization approach.

Adolescent↗

Recovery of nerve root function after complete quadriplegia from cervical spine fractures.

Thirty-five patients with complete myelopathies secondary to cervical spine fractures from C-4 to C-7 underwent spinal decompressions and fusions between 1975 and 1981. Twenty-five of these patients underwent simultaneous nerve root decompressions, 23 with an accompanying anterior decompression and fusion and 2 with an accompanying posterior fusion. Substantial recovery of nerve root function occurred in 15 of these patients. A posterior reduction and fusion without nerve root decompression was performed in each of the remaining 10 patients. None of these patients demonstrated a significant improvement neurologically. Operation for nerve root decompression is indicated in selected victims of spinal cord injury.

Cervical Vertebrae↗

Internal carotid artery stump angioplasty for the treatment of cerebrovascular occlusive disease.

Nineteen patients underwent a total of 21 stump angioplasty procedures for an occluded internal carotid artery. Indications for surgery included the preparation of the donor vessel for a subsequent extracranial-intracranial bypass procedure, the occurrence of emboli to the intracranial vasculature from the external carotid artery circulation, and the association with symptomatic occlusive disease of the external carotid artery accompanying occlusion of the ipsilateral internal carotid artery. The technique utilized and the results obtained in these 19 patients are presented. In select patients, the removal of an occluded internal carotid artery stump via a stump angioplasty is beneficial in preventing the catastrophic sequela of embolic cerebrovascular disease.

Arterial Occlusive Diseases↗

Trauma to the high cervical carotid artery.

An alternative approach to the treatment of distal extracranial nonoccluding internal carotid artery penetrating injuries is described in which internal carotid artery ligation is followed expectantly. A warning transient neurologic deficit prompted an unsuccessful attempt at revascularization via a superficial temporal artery to middle cerebral artery anastomosis. The failure of the anastomosis was thought to be secondary to a postinjury hypercoagulable state and a diminished demand for intracranial blood flow secondary to an unexpected, impressive development of collateral blood supply.

Adult↗

Neurological improvement associated with late decompression of the thoracolumbar spinal cord.

We reviewed the cases of 20 patients admitted to our institution with thoracolumbar spinal cord injury who had previously undergone laminectomy and/or spinal instrumentation. Thirteen patients had a mass in the spinal canal, and 7 had kyphotic deformities. The lateral extracavitary approach to the spine and posterior stabilization when indicated were done in each. Seventeen patients obtained substantial neurological improvement. All 7 patients with kyphosis regained the ability to walk, as did all but 3 of the nonambulatory patients with a mass in the spinal canal. Morbidity was limited to pneumothorax and 1 case of late kyphosis associated with premature removal of the spinal fixation devices. Elective anterior approaches for reconstruction of the spinal canal with appropriate stabilization afford the best opportunity for neurological improvement in cases of thoracolumbar spinal cord injury.

Fracture Fixation↗

Spinal intradural extraarachnoid metastasis.

A case of carcinomatous metastasis at the L2-3 level localized in the intradural extraarachnoid space is presented. The anatomy of the subarachnoid angle where the transition occurs from peripheral nerve to nerve root is reviewed. Anatomic evidence suggests that the spread of the tumor to the potential intradural extraarachnoid space might be via the perineural sheath.

Arachnoid↗

Computed tomography of traumatic atlantooccipital dislocation.

Although atlantooccipital dislocation is a well-recognized radiological entity, its computed tomographic (CT) recognition has not been previously described. It is the purpose of this report to show the complementary role of CT in precisely defining the abnormalities in both the coronal and the sagittal reconstruction planes. A case is presented and the literature is reviewed.

Atlanto-Occipital Joint↗

Spine policy.

Explore the source record for details and available documents.

Health Policy↗

Evaluation of CSF shunt function: value of functional examination with contrast material.

Functional positive-contrast shuntography includes a patency check of both limbs of the shunt and the shunt valve by fluoroscopy following the injection of an iodinated contrast agent (anatomic shuntogram) and an assessment of the adequacy of ventricular fluid drainage under physiologic conditions by using serial CT scans to assess the rate of iodine dissipation from the ventricular system (physiologic shuntogram). To demonstrate its efficacy and utility, 82 functional shuntograms were obtained in 55 patients. Fifty-one of the 82 studies were abnormal. Of these, 22 demonstrated patency of both the proximal and distal limbs with an accompanying slow dissipation of contrast material after injection (21 of 22 patients were adults). Eighteen of these 22 patients improved following the reduction of shunt drainage pressure. In the case of frank shunt obstruction, the site of obstruction was delineated clearly in all 29 cases. Correlation of clinical outcome with test results confirmed the utility of this technique, especially when applied to the shunted adult hydrocephalic patient whose response to the shunt had been inadequate. The technique described here allows the clinician to differentiate between physiologic and anatomic shunt failure and between shunt failure and normal shunt function. It also allows for precise localization of the shunt obstruction in anatomic shunt failure and for demonstration of physiologic shunt failure when shunt patency is demonstrated in the presence of the slow dissipation of intraventricular contrast medium.

Adult↗

Metrizamide shuntography for evaluation of shunt malfunction in hydrocephalus.

Ventricular shunts were evaluated by a shuntographic technique using metrizamide for the contrast material and delayed spot films and computed tomography (CT) to evaluate shunt function. Thirty hydrocephalic patients were studied who had clinical presentations of shunt malfunction. Fifty-two shuntograms were obtained; most demonstrated the cause of shunt malfunction. No contrast-related complications resulted from the procedure. Diagnostic accuracy was greatly improved by this method, since both anatomic and functional evaluations could be performed. In patients with normal studies, unnecessary surgery was eliminated; in abnormal shuntograms, the duration of surgery and the likelihood of complications were reduced because the surgeons knew the exact anatomic derangements to be corrected.

Cerebrospinal Fluid Shunts↗