Accurate skin dose measurements using radiochromic film in clinical applications.

Megavoltage x-ray beams exhibit the well-known phenomena of dose buildup within the first few millimeters of the incident phantom surface, or the skin. Results of the surface dose measurements, however, depend vastly on the measurement technique employed. Our goal in this study was to determine a correction procedure in order to obtain an accurate skin dose estimate at the clinically relevant depth based on radiochromic film measurements. To illustrate this correction, we have used as a reference point a depth of 70 micron. We used the new GAFCHROMIC dosimetry films (HS, XR-T, and EBT) that have effective points of measurement at depths slightly larger than 70 micron. In addition to films, we also used an Attix parallel-plate chamber and a home-built extrapolation chamber to cover tissue-equivalent depths in the range from 4 micron to 1 mm of water-equivalent depth. Our measurements suggest that within the first millimeter of the skin region, the PDD for a 6 MV photon beam and field size of 10 x 10 cm2 increases from 14% to 43%. For the three GAFCHROMIC dosimetry film models, the 6 MV beam entrance skin dose measurement corrections due to their effective point of measurement are as follows: 15% for the EBT, 15% for the HS, and 16% for the XR-T model GAFCHROMIC films. The correction factors for the exit skin dose due to the build-down region are negligible. There is a small field size dependence for the entrance skin dose correction factor when using the EBT GAFCHROMIC film model. Finally, a procedure that uses EBT model GAFCHROMIC film for an accurate measurement of the skin dose in a parallel-opposed pair 6 MV photon beam arrangement is described.

Computer Simulation↗

Comparison of measured and Monte Carlo calculated dose distributions in inhomogeneous phantoms in clinical electron beams.

Calculations of dose distributions in heterogeneous phantoms in clinical electron beams, carried out using the fast voxel Monte Carlo (MC) system XVMC and the conventional MC code EGSnrc, were compared with measurements. Irradiations were performed using the 9 MeV and 15 MeV beams from a Varian Clinac-18 accelerator with a 10 x 10 cm2 applicator and an SSD of 100 cm. Depth doses were measured with thermoluminescent dosimetry techniques (TLD 700) in phantoms consisting of slabs of Solid Water (SW) and bone and slabs of SW and lung tissue-equivalent materials. Lateral profiles in water were measured using an electron diode at different depths behind one and two immersed aluminium rods. The accelerator was modelled using the EGS4/BEAM system and optimized phase-space files were used as input to the EGSnrc and the XVMC calculations. Also, for the XVMC, an experiment-based beam model was used. All measurements were corrected by the EGSnrc-calculated stopping power ratios. Overall, there is excellent agreement between the corrected experimental and the two MC dose distributions. Small remaining discrepancies may be due to the non-equivalence between physical and simulated tissue-equivalent materials and to detector fluence perturbation effect correction factors that were calculated for the 9 MeV beam at selected depths in the heterogeneous phantoms.

Algorithms↗

Electron fluence correction factors for various materials in clinical electron beams.

Relative to solid water, electron fluence correction factors at the depth of dose maximum in bone, lung, aluminum, and copper for nominal electron beam energies of 9 MeV and 15 MeV of the Clinac 18 accelerator have been determined experimentally and by Monte Carlo calculation. Thermoluminescent dosimeters were used to measure depth doses in these materials. The measured relative dose at dmax in the various materials versus that of solid water, when irradiated with the same number of monitor units, has been used to calculate the ratio of electron fluence for the various materials to that of solid water. The beams of the Clinac 18 were fully characterized using the EGS4/BEAM system. EGSnrc with the relativistic spin option turned on was used to optimize the primary electron energy at the exit window, and to calculate depth doses in the five phantom materials using the optimized phase-space data. Normalizing all depth doses to the dose maximum in solid water stopping power ratio corrected, measured depth doses and calculated depth doses differ by less than +/- 1% at the depth of dose maximum and by less than 4% elsewhere. Monte Carlo calculated ratios of doses in each material to dose in LiF were used to convert the TLD measurements at the dose maximum into dose at the center of the TLD in the phantom material. Fluence perturbation correction factors for a LiF TLD at the depth of dose maximum deduced from these calculations amount to less than 1% for 0.15 mm thick TLDs in low Z materials and are between 1% and 3% for TLDs in Al and Cu phantoms. Electron fluence ratios of the studied materials relative to solid water vary between 0.83+/-0.01 and 1.55+/-0.02 for materials varying in density from 0.27 g/cm3 (lung) to 8.96 g/cm3 (Cu). The difference in electron fluence ratios derived from measurements and calculations ranges from -1.6% to +0.2% at 9 MeV and from -1.9% to +0.2% at 15 MeV and is not significant at the 1sigma level. Excluding the data for Cu, electron fluence correction factors for open electron beams are approximately proportional to the electron density of the phantom material and only weakly dependent on electron beam energy.

Electrons↗

A monitor unit "odometer" for measuring linac workload.

The annual linac workload is often required by regulatory agencies to assess compliance with license conditions. Summation of the monitor units produced by the machine is generally used for this purpose. Various methods of estimating this value have inherent inaccuracies. We have built an integrating Monitor Unit "odometer" that is able to automatically accumulate all MUs delivered by the linac and segregate the total by mode (photon or electron) and energy. The device has been used to record clinical linac MU workloads for 10 months, and was installed in a new dual-energy linac during the acceptance and commissioning process.

Electrons↗

Designing attenuators for total-body irradiation using virtual simulation.

In total-body photon irradiation, the lungs are the most commonly shielded organ. Lung compensators are often designed by using high-energy portal films. Other organs, such as the kidneys and liver, are poorly visualized in portal films due to their unit-density composition. A computed tomography-based technique to design kidney and liver attenuators involves outlining these organs in a virtual simulation. The position and the shape of the attenuator are then determined from a digitally-reconstructed radiograph. Appropriate attenuator thickness is determined from measured transmission curves. This article provides a summary of this technique for total-body photon irradiation in a 4-MV photon beam.

Computer Simulation↗

Saturation current and collection efficiency for ionization chambers in pulsed beams.

Saturation currents and collection efficiencies in ionization chambers exposed to pulsed megavoltage photon and electron beams are determined assuming a linear relationship between 1/I and 1/V in the extreme near-saturation region, with I and V the chamber current and polarizing voltage, respectively. Careful measurements of chamber current against polarizing voltage in the extreme near-saturation region reveal a current rising faster than that predicted by the linear relationship. This excess current combined with conventional "two-voltage" technique for determination of collection efficiency may result in an up to 0.7% overestimate of the saturation current for standard radiation field sizes of 10X10 cm2. The measured excess current is attributed to charge multiplication in the chamber air volume and to radiation-induced conductivity in the stem of the chamber (stem effect). These effects may be accounted for by an exponential term used in conjunction with Boag's equation for collection efficiency in pulsed beams. The semiempirical model follows the experimental data well and accounts for both the charge recombination as well as for the charge multiplication effects and the chamber stem effect.

Biophysical Phenomena↗

Detecting electron beam energy shifts with a commercially available energy monitor.

Routine electron beam quality assurance requires an accurate, yet practical, method of energy characterization. Subtle shifts in beam energy may be produced by the linac bending magnet assembly, and the sensitivity of a commercially available electron beam energy-monitoring device for monitoring these small energy drifts has been evaluated. The device shows an 11% change in signal for a 2 mm change in the I50 energy parameter for low energy electron beams (in the vicinity of 6 MeV) and a 2.5% change in signal for a 2 mm change in the I50 energy parameter for high energy electron beams (in the vicinity of 22 MeV). Thus the device is capable of detecting small energy shifts resulting from bending magnet drift for all clinically relevant electron beams.

Dose-Response Relationship, Radiation↗

Dosimetry of hip irradiation for the prevention of heterotopic bone formation after arthroplasty.

PURPOSE: The dosimetry of hip irradiation for the prevention of heterotopic bone formation following arthroplasty is complicated by the use of custom shielding in the treatment portal, and the fact that irradiation is usually required during a 48 hour period following surgery. Both the machine output and depth dose factors of the resulting fields are modified by the presence of the shielding blocks. A simplified dosimetric approach, based on correction factors for both the output and depth dose as a function of field geometry is presented for various megavoltage energy beams. MATERIALS AND METHODS: Measurements of relative dose factors (RDF) and percentage depth dose (PDD) were carried out for different combinations of field size, block size and separation between adjacent blocks. Both RDF and PDD measurements were made in a water phantom. Ratios of RDF and PDD were obtained by dividing individual measurements or curves by the corresponding values for the open field (i.e., without blocks). The average values of these ratios constitute the correction factors to be applied for a given MU or treatment time calculation. RESULTS: Extensive RDF and PDD measurements reveal that for the field and block dimensions of interest the correction factors for RDF can be parameterized as a function of separation between two adjacent blocks and beam energy alone and the depth correction factors are additionally only a function of depth. The correction factors for depth dose are equally valid for fixed source-skin distance techniques (that use PDD) and fixed source-axis distance techniques (that use TMR). CONCLUSION: A simple model for the calculation of output in hip irradiation is presented for the situation where the use of computer-based algorithms may not be practical. The model accurately predicts the RDF of the treatment portal to within 2% and the PDD to within 2% for the range of field sizes, block sizes, block gaps and beam energies of interest ignoring other variables.

Arthroplasty, Replacement, Hip↗

Verification of segmented beam delivery using a commercial electronic portal imaging device.

In modern radiotherapy, three-dimensional conformal dose distributions are achieved through the delivery of beam ports having precalculated planar distributions of photon beam intensity. Although sophisticated means to calculate and deliver these spatially modulated beams have been developed, means to verify their actual delivery are relatively cumbersome, making equipment and treatment quality assurance difficult to enforce. An electronic portal imaging device of the scanning liquid ionization chamber type yields images which, once calibrated from a previously determined calibration curve, provide highly precise planar maps of the incident dose rate. For verification of an intensity-modulated beam delivered in the segmented approach with a multileaf collimator, a portal image is acquired for each subfield of the leaf sequence. Subsequent to their calibration, the images are multiplied by their respective associated monitor unit settings, and summed to produce a planar dose distribution at the measurement depth in phantom. The excellent agreement of our portal imager measurements with calculations of our treatment planning system and measurements with a one-dimensional beam profiler attests to the usefulness of this method for the planar verification of intensity-modulated fields produced in the segmented approach on a computerized linear accelerator equipped with a multileaf collimator.

Humans↗

Setup verification in linac-based radiosurgery.

A semi-automatic technique for the direct setup alignment of radiosurgical circular fields from an isocentric linac to treatment room laser cross-hairs is described. Alignment is achieved by acquiring images of the treatment room positioning laser cross-hairs superimposed on the radiosurgical circular field image. An alignment algorithm calculates the center of the radiosurgical field image as well as the intersection of the laser cross-hairs. This determines any alignment deviations and the information is then used to translate the radiosurgical collimator to its correct aligned position. Two detectors, each being sensitive to the lasers and ionizing radiation, were used to acquire the radiation/laser images. The first detector consists of a 0.3-mm-thick layer of photoconducting a-Se deposited on a 1.5-mm-thick copper plate and the second is film. The algorithm and detector system can detect deviations with a precision of approximately 0.04 mm. A device with gyroscopic degrees of freedom was built in order to firmly hold the detector at any orientation perpendicular to the radiosurgical beam axis. This device was used in conjunction with our alignment algorithm to quantify the isocentric sphere relative to the treatment room lasers over all gantry and couch angles used in dynamic stereotactic radiosurgery.

Algorithms↗

Stereotactic radiation in primary brain tumors in children and adolescents.

To evaluate treatment outcome and morbidity of stereotactic external-beam irradiation (SEBI) in pediatric patients, we reviewed 14 children treated with SEBI, using a 10-MV isocentric linear accelerator at McGill University between 1988 and 1994. The median follow-up was 46 months (range 6-82 months). The median age was 14 years. There were 8 low-grade astrocytomas, 3 neuromas and 4 other histologies. Twelve patients received fractionated treatments. The median collimator diameter was 2.5 cm (range 1-5 cm). The median biological effective dose delivered to the entire tumor volume was 57 Gy for astrocytomas and 43 Gy for the other histologies. The overall actuarial survival rate and disease-free survival rate at 5 years were 83 and 62%, respectively. For the patients with low-grade astrocytomas, the 5-year survival and disease-free survival rates were 100 and 60%, respectively. Four children had recurrence at a median of 37 months. Four patients developed treatment-related complications: 1 had edema alone, 2 had necrosis and 1 had edema associated with necrosis. Neither the physical nor radiobiological parameters were predictive of the treatment outcome or the treatment complications. Stereotactic irradiation is a valid option for progressive nonresectable tumors in children.

Adolescent↗

The integral biologically effective dose to predict brain stem toxicity of hypofractionated stereotactic radiotherapy.

OBJECTIVE: The aim of this work was to develop a parameter for use during fractionated stereotactic radiotherapy treatment planning to aid in the determination of the appropriate treatment volume and fractionation regimen that will minimize risk of late damage to normal tissue. MATERIALS & METHODS: We have used the linear quadratic model to assess the biologically effective dose at the periphery of stereotactic radiotherapy treatment volumes that impinge on the brain stem. This paper reports a retrospective study of 77 patients with malignant and benign intracranial lesions, treated between 1987 and 1995, with the dynamic rotation technique in 6 fractions over a period of 2 weeks, to a total dose of 42 Gy prescribed at the 90% isodose surface. From differential dose-volume histograms, we evaluated biologically effective dose-volume histograms and obtained an integral biologically-effective dose (IBED) in each case. RESULTS: Of the 77 patients in the study, 36 had target volumes positioned so that the brain stem received more than 1% of the prescribed dose, and 4 of these, all treated for meningioma, developed serious late damage involving the brain stem. Other than type of lesion, the only significant variable was the volume of brain stem exposed. An analysis of the IBEDs received by these 36 patients shows evidence of a threshold value for late damage to the brain stem consistent with similar thresholds that have been determined for external beam radiotherapy. CONCLUSION: We have introduced a new parameter, the IBED, that may be used to represent the fractional effective dose to structures such as the brain stem that are partially irradiated with stereotactic dose distributions. The IBED is easily calculated prior to treatment and may be used to determine appropriate treatment volumes and fractionation regimens minimizing possible toxicity to normal tissue.

Adolescent↗

Proton beam output measurement with an extrapolation chamber.

A variable air-volume, parallel-plate extrapolation chamber forming an integral part of a polystyrene phantom was used in measurement of dose rate in a 250 MeV clinical proton beam. The sensitive air-volume of the extrapolation chamber is controlled through the movement of the chamber piston by means of a micrometer mounted on the phantom body. The relative displacement of the piston is monitored by a calibrated mechanical distance travel indicator. The proton beam dose rate determined with the uncalibrated extrapolation chamber was 5% lower than the dose rate determined with a calibrated Farmer-type thimble chamber at the same depth in the polystyrene phantom. Despite the current 5% discrepancy, uncalibrated extrapolation chambers may offer a simple and practical alternative to current techniques used in output measurements of proton beam machines.

Calibration↗

Verification of the correspondence between CT-stimulated and treatment beams.

A single phantom technique has been developed to verify the full CT simulation and treatment-beam delivery procedures. The phantom consists of a target delineated by thin copper strips, affixed to therapy verification film, and inserted securely between two slices of water-equivalent material. The target is defined with the aid of the copper strips, and the position of the isocenter and beam parameters such as field size, and gantry and collimator angle are determined by CT simulation. With these parameters, the phantom is subsequently irradiated by the linear accelerator in the treatment position. Correspondence between the planned and the irradiated region is determined by the position of the copper strips on the film. The technique is a simple and practical method for verifying the entire CT simulation and treatment-beam delivery processes, and provides a permanent record of the correspondence between the planning digitally reconstructed radiographs (DRR) and the actual beam delivered.

Computer Simulation↗

Determination of saturation charge and collection efficiency for ionization chambers in continuous beams.

The procedure recommended by radiation dosimetry protocols for determining the collection efficiency f of an ionization chamber assumes the predominance of general recombination and ignores other charge loss mechanisms such as initial recombination and ionic diffusion. For continuous radiation beams, general recombination theory predicts that f can be determined from a linear relationship between 1/Q and 1/V2 in the near saturation region (f > 0.7), where Q is the measured charge and V the applied chamber potential. Measurements with Farmer-type cylindrical ionization chambers exposed to cobalt-60 gamma rays reveal that the assumed linear relationship between 1/Q and 1/V2 breaks down in the extreme near-saturation region (f > 0.99) where Q increases with V at a rate exceeding the predictions of general recombination theory. A comprehensive model is developed to describe the saturation characteristics of ionization chambers. The model accounts for dosimetric charge loss (initial recombination, ionic diffusion, and general recombination) and nondosimetric charge multiplication in an ionization chamber, and suggests that charge multiplication plays a significant role under typical chamber operating conditions (300 V) used in radiation dosimetry. Through exclusion of charge multiplication from the measured chamber signal Q, the model predicts the breakdown of the 1/Q vs 1/V2 relationship and shows that the final approach to saturation is governed by initial recombination and ionic diffusion which are characterized by a linear relationship between 1/Q and 1/V. Collection efficiencies calculated with this model differ by up to 0.4% from those determined through a rigorous application of general recombination theory alone.

Biophysical Phenomena↗

Superficial and orthovoltage x-ray beam dosimetry.

Output of superficial and orthovoltage x-ray units may be measured with cylindrical or end-window parallel-plate ionization chambers. The air-kerma calibration factors for these chambers are usually determined free in air, and the x-ray machine output is stated as the air-kerma rate free in air, which, when multiplied with the appropriate backscatter factor, gives the air-kerma rate on the surface of a phantom or patient. For end-window chambers, especially when they are used for measurements of small fields or low x-ray energies, the air-kerma calibration factors may also be determined with the chamber embedded in a tissue-equivalent phantom. This results in field size dependent air-kerma in-air calibration factors but obviates the requirement for knowledge of back-scatter factors when determining the air-kerma rate on the surface of a phantom. Since there still is considerable uncertainty in tabulated backscatter factors as a function of field size and x-ray beam energy, the output measurement technique which determines the air-kerma rate on phantom surface with a phantom-embedded end-window ionization chamber offers a clear advantage over the in-air calibration method.

Air↗

Viability of an isocentric cobalt-60 teletherapy unit for stereotactic radiosurgery.

The potential for radiosurgery with an isocentric teletherapy cobalt unit was evaluated in three areas: (1) the physical properties of radiosurgical beams, (2) the quality of radiosurgical dose distributions obtained with four to ten noncoplanar converging arcs, and (3) the accuracy with which the radiosurgical dose can be delivered. In each of these areas the cobalt unit provides a viable alternative to an isocentric linear accelerator (linac) as a radiation source for radiosurgery. A 10 MV x-ray beam from a linac used for radiosurgery served as a standard for comparison. The difference between the 80%-20% penumbras of stationary radiosurgical fields in the nominal diameter range from 10 to 40 mm of the cobalt-60 and 10 MV photon beams is remarkably small, with the cobalt-60 beam penumbras, on average, only about 0.7 mm larger than those of the linac beam. Differences between the cobalt-60 and 10 MV radiosurgical treatment plans in terms of dose homogeneity within the target volume, conformity of the prescribed isodose volume to the target volume, and dose falloffs outside the target volume are also minimal, and therefore of essentially no clinical significance. Moreover, measured isodose distributions for a radiosurgical procedure on our Theratron T-780 cobalt unit agreed with calculated distributions to within the +/- 1 mm spatial and +/- 5% numerical dose tolerances, which are generally specified for radiosurgery. The viability of isocentric cobalt units for radiosurgery will be of particular interest to centers in developing countries where cobalt units, because of their relatively low costs, provide the only megavoltage source of radiation for radiotherapy, and could easily and inexpensively be modified for radiosurgery. Of course, the quality assurance protocols and mechanical condition of a particular teletherapy cobalt unit must meet stringent requirements before the use of the unit for radiosurgery can be advocated.

Biophysical Phenomena↗