Search PubMed⌕ Search

Biomedical subjects

E Adalsteinsson

Publications and source records attributed to E Adalsteinsson.

25 records · Page 2Linked to original sources

Feasibility study of lactate imaging of head and neck tumors.

A proton spectroscopic imaging sequence was used to investigate the feasibility of lactate imaging in head and neck tumors. The sequence employs a two-shot lactate editing method with inversion recovery for additional lipid suppression, and a restricted field of view to suppress motion artifacts. Variations in acquisition parameters and two different receive coils were investigated on twelve patients. Elevated lactate was detected in three patients, no lactate was observed in seven patients, and two studies were inconclusive because of severe motion or inhomogeneity artifacts. Best results were obtained with an anterior/posterior neck coil at a 288 ms echo time (TE).

Adult↗

Volumetric spectroscopic imaging with spiral-based k-space trajectories.

Spiral-based k-space trajectories were applied in a spectroscopic imaging sequence with time-varying readout gradients to collect volumetric chemical shift information. In addition to spectroscopic imaging of low signal-to-noise ratio (SNR) brain metabolites, the spiral trajectories were used to rapidly collect reference signals from the high SNR water signal to automatically phase the spectra and to aid the reconstruction of metabolite maps. Spectral-spatial pulses were used for excitation and water suppression. The pulses were designed to achieve stable phase profiles in the presence of up to 20% variation in the radiofrequency field. A gridding algorithm was used to resample the data onto a rectilinear grid before fast Fourier transforms. This method was demonstrated by in vivo imaging of brain metabolites at 1.5 T with 10 slices of 18 x 18 pixels each. Nominal voxel size was 1.1 cc, spectral bandwidth was 400 Hz, scan time was 18 min for the metabolite scan and 3 min for the reference scan.

Aspartic Acid↗

Quantitative assessment of improved homogeneity using higher-order shims for spectroscopic imaging of the brain.

Magnetic field homogeneity is of major concern for in vivo spectroscopy, and with the increased use of volumetric chemical shift imaging (CSI) techniques, the ability to shim over a large volume of tissue is now one of the primary limiting constraints in performing these studies. In vivo shimming is routinely performed using linear shim correction terms, and although many scanners are also equipped with additional resistive shim supplies that can provide second and third-order shim fields, they are often not used due to the additional effort and scan time required. The question as to how much improvement can be achieved using additional higher-order shims compared with the linear shims alone was quantitatively addressed. Performance measures for both intervoxel B0 uniformity and intravoxel T2* line broadening were evaluated for 15 normal volunteers. The analysis tools developed in this study, along with the summarized data, can be useful in deciding if a given application warrants the additional time, effort, and expense (if additional hardware needs to be purchased) of implementing higher-order shimming routines. For CSI studies of the brain, the use of the higher-order shims, compared with linear terms alone, yielded approximately 30% greater volume of brain tissue that could be shimmed within typical constraints for intervoxel B0 shifts and intravoxel T2* linebroadening. In addition, a regional analysis shows significant improvement in the homogeneity within specific areas of the brain, particularly those near the skull.

Adult↗

In vivo lactate editing with simultaneous detection of choline, creatine, NAA, and lipid singlets at 1.5 T using PRESS excitation with applications to the study of brain and head and neck tumors.

Two T2-independent J-difference lactate editing schemes for the PRESS magnetic resonance spectroscopy localization sequence are introduced. The techniques, which allow for simultaneous acquisition of the lactate doublet (1.3 ppm) and edited singlets upfield of and including choline (3.2 ppm), exploit the dependence of the in-phase intensity of the methyl doublet upon the time interval separating two inversion (BASING) pulses applied to its coupling partner after initial excitation. Editing method 1, which allows for echo times TE = n/J (n = 1, 2, 3, . . . . ), alters the BASING carrier frequency for each of two cycles so that, for one cycle, the quartet is inverted, whereas, for the other cycle, the quartet is unaffected. Method 2, which also provides water suppression, allows for editing for TE > 1/J by alternating, between cycles, the time interval separating the inversion pulses. Experimental results were obtained at 1.5 T using a Shinnar Le-Roux-designed maximum phase inversion pulse with a filter transition bandwidth of 55 Hz. Spectra were acquired from phantoms and in vivo from the human brain and neck. In a neck muscle study, the lipid suppression factor, achieved partly through the use of a novel phase regularization algorithm, was measured to be over 10(3). Spectra acquired from a primary brain and a metastatic neck tumor demonstrated the presence of lactate and choline signals consistent with abnormal spectral patterns. The advantages and limitations of the methods are analyzed theoretically and experimentally, and significance of the results is discussed.

Aspartic Acid↗

MELAS: Clinical and pathologic correlations with MRI, xenon/CT, and MR spectroscopy.

We describe the clinical, imaging, and pathologic findings in a patient with mitochondrial myopathy, encephalopathy, lactic acidosis, and stroke-like episodes (MELAS). The patient experienced her first stroke-like episode at age forty-four. Brain MRI, obtained at symptom onset, at 3 weeks, and at 1 year, revealed migrating T2-weighted hyperintensities in the temporal/parietal and occipital cortices and later revealed atrophy. Abnormal cerebrovascular reserve was evident on xenon/CT four days after the first MRI. MR spectroscopy at 1 year revealed increased lactate in both the occipital and temporal lobes. Histologic sections demonstrated spongy degeneration of the cortex that was most prominent at the crests of the gyri. Electron microscopy of the blood vessels showed increased numbers of abnormal mitochondria within the vascular smooth muscle and in endothelial cells. We hypothesize that the stroke-like episodes in MELAS may be due to impaired autoregulation secondary to the impaired metabolic activity of mitochondria in the endothelial and smooth muscle cells of blood vessels.

Adult↗

Three-dimensional spectroscopic imaging with time-varying gradients.

A spectroscopic imaging sequence with a time-varying readout gradient in the slice selection direction is used to image multiple contiguous slices. For a given voxel size, the imaging time and signal-to-noise ratio of the three-dimensional spectroscopic sequence are the same as for a single slice acquisition without the oscillating readout gradient. The data reconstruction employs a gridding algorithm in two dimensions to interpolate the nonuniformly sampled data onto a Cartesian grid, and a fast Fourier transform in four dimensions: three spatial dimensions and the spectral dimension. The method is demonstrated by in vivo imaging of NAA in human brain at 1.5 T with 10 slices of 16 x 16 pixels spectroscopic images acquired in a total scan time of 17 min.

Algorithms↗

Incorporating lactate/lipid discrimination into a spectroscopic imaging sequence.

A spectroscopic imaging sequence incorporating a two-shot lactate editing method was used in two human brain studies to image lactate and NAA. The subtractive editing method allows separate images of lactate, NAA, and lipids to be collected during a single study with no SNR penalty. The sequence uses a spectral-spatial excitation for slice selection and water suppression, and employs inversion recovery and an echo time of 136 ms for additional lipid suppression.

Aspartic Acid↗