Multivariate analysis of factors affecting waiting time to heart transplantation.

BACKGROUND: The growing clinical success of cardiac transplantation has resulted in a dramatic increase in the number of patients referred and subsequently listed for cardiac transplantation. Paradoxically, in the presence of a limited donor organ pool, such expansion has increased both the waiting time for transplantation and the number of patients dying while on the waiting list. METHODS: We performed univariate and multivariate analyses of the waiting times of 301 patients listed for transplantation using a Cox proportional hazards model to evaluate the simultaneous effect of multiple variables on the waiting time of heart transplant candidates. Variables considered included age, sex, race, blood type, weight at listing, United Network for Organ Sharing (UNOS) status at listing, UNOS status at transplantation, and proportion of time on the waiting list as UNOS status 1. RESULTS: The mean waiting time for patients ultimately having transplantation was 170.2 +/- 206.0 days; the median waiting time was 103.5 days. Age, sex, weight, blood type, and percent of time as UNOS status 1 all had a significant impact on waiting time in the univariate analysis. By multivariate analysis, proportion of time as UNOS status 1, lower weight at listing, and blood type AB were all highly associated as predictors of a shorter waiting time. Weight at listing represented a continuous variable whose risk ratio for a shorter waiting time correlated in such a way that the risk of a longer waiting time increased 2.3 per 22.5-kg (50-pound) increase in weight. Blood types A and B, although associated with a shorter waiting time, correlated less strongly than the other three variables. CONCLUSIONS: Our findings from this multivariate analysis demonstrate that UNOS status, blood type, and weight were the variables that most strongly affected overall waiting time for transplantation. It is our hope to define more accurately a group of patients with both a high likelihood of a long waiting time and a prohibitive risk of death while on the waiting list, who therefore may benefit from surgical alternatives to transplantation.

ABO Blood-Group System↗

Low thromboembolic risk without anticoagulation using advanced-design left ventricular assist devices.

BACKGROUND: A major limitation of cardiac assist devices has been the high incidence of thromboembolic events and their requirement for systemic anticoagulation. The Thermo Cardiosystems HeartMate 1000 IP left ventricular assist device (LVAD) employs a design that may reduce thromboembolic risk and obviate the need for systemic anticoagulation. METHODS: Two hundred twenty-three patients with nonreversible heart failure were supported with the HeartMate LVAD as a bridge to heart transplantation. All patients were monitored prospectively for thromboembolic events. Anticoagulation regimens and occurrence of subclinical thromboembolic events, including those seen by transcranial Doppler examinations in selected patients, were also recorded. RESULTS: Total time of LVAD support use was 531.2 patient-months. Twenty-three patients (10%) received warfarin postoperatively for 42.4 patient-months (8.2% of total support time). Six patients (2.7%) had thromboembolic events, representing 0.011 events per patient-month of device use. CONCLUSIONS: The thromboembolic complication rate associated with this LVAD is acceptably low despite the minimal anticoagulation employed in this series, allowing consideration of long-term device use for the treatment of heart failure.

Adolescent↗

Outpatient left ventricular assist device support: a destination rather than a bridge.

BACKGROUND: To evaluate the feasibility and efficacy of outpatient left ventricular assist devices as a bridge to transplantation, we reviewed the initial clinical experience with this modality at our institution. METHODS: During January 1993 to November 1995, 12 male and 2 female patients with an average age of 47 +/- 17 years were supported for an average of 117 +/- 24 days with the Thermo Cardiosystems VE wearable left ventricular assist device. Seven patients were discharged home an average of 35 +/- 4 days after implantation. RESULTS: No device failures occurred, although 29 controller malfunctions were identified during 1,640 total support days. All patients were able to safely maintain their devices. Outflow graft bleeding and driveline infection were responsible for two readmissions. No long-term anticoagulation treatment was used; one small thromboembolic episode occurred, but without significant long-term sequelae. CONCLUSIONS: None of the 7 patients released from the hospital died, and all were able to successfully maintain their devices at home. Hospital discharge of patients supported with left ventricular assist devices has allowed long-term evaluation of this technology, and the findings should prompt study of their use as a long-term alternative treatment to medical management for congestive heart failure.

Adolescent↗

Extended indications for lung volume reduction surgery in advanced emphysema.

BACKGROUND: Lung volume reduction surgery has shown early promise as a palliative therapy in severe emphysema. Selection of potential candidates has been based on certain functional and anatomic criteria, and a variety of operative contraindications have been proposed. METHODS: Over 15 months, we performed lung volume reduction surgery in 85 patients selected on the basis of severe hyperinflation with air trapping, diaphragmatic dysfunction, and disease heterogeneity. Patients were not excluded on the basis of severe hypercapnia, steroid dependence, profound pulmonary dysfunction, or inability to complete preoperative rehabilitation. RESULTS: We observed significant improvements in pulmonary function, exercise capacity, and dyspnea, with an acceptable 30-day perioperative mortality of 7% and actuarial survival of 90% and 83% at 6 and 12 months, respectively. In each "high-risk" group, perioperative mortality, actuarial survival to 1 year, and functional results were equivalent, and in some cases superior, to those in the corresponding "low-risk" patients. CONCLUSIONS: Severe hypercapnia, steroid dependence, profound pulmonary dysfunction, and inability to complete preoperative rehabilitation do not preclude successful lung volume reduction surgery and should not be regarded as absolute exclusionary criteria.

Aged↗

The influence of concordant xenografts on the humoral and cell-mediated immune responses to subsequent allografts in primates.

The humoral and cell-mediated immune responses to subsequent allografts were determined in primate recipients after concordant xenotransplantation as a bridge to allotransplantation. Heterotopic heart transplants (n = 4) were performed from cynomolgus monkeys into ABH type-matched olive baboons followed 2 weeks later by allotransplantation from ABH type-matched baboon donors. Allografts were explanted at 8 weeks. All recipients underwent splenectomy at the time of xenotransplantation and received immunosuppression with cyclosporine, azathioprine, and methylprednisolone. Concordant xenotransplantation in these primates did not induce humoral or cell-mediated immune responses that jeopardized subsequent allografts. The degree of xenospecific immune reactivity, as determined by specific cytotoxicity of recipient T-cell lines derived from the xenograft and extent of histologic xenograft rejection, did not predict the severity of subsequent allograft rejection. In two of the four recipients, xenotransplantation induced an alloreactive humoral response against antigens expressed by the B cells of more than 50% of members from a panel of 12 unrelated baboons. In all recipients, priming with xenogeneic splenocytes in vitro induced an accelerated proliferative T-cell response to allogeneic lymphocytes from 16% of this panel. This study affirms the role of concordant xenografts as appropriate biologic bridges to human allotransplantation. However, our results suggest that xenoreactive baboon memory CD4 T cells may recognize major histocompatibility complex class II--like structures shared between the xenogeneic and allogeneic targets. The potential allorecognition induced by a xenograft may affect the process of subsequent allograft donor selection.

Animals↗

Miniature axial flow pump for ventricular assistance in children and small adults.

We investigated the efficacy of the Jarvik 2000 intraventricular assist device (Jarvik Research, Inc., New York, N.Y.) in an ovine model. The device is an axial flow pump measuring 1.8 cm in diameter by 5 cm long, has a displacement volume of 12 ml, and can deliver flow from 2 to 7 L/min. Seven devices were implanted through a left thoracotomy into the left ventricle with an outflow graft to the descending aorta. Animals were treated with warfarin sodium and aspirin to maintain prothrombin times approximately 1.5 times control. Animals were followed up for 3 to 123 days. Two animals died of operative complications at days 3 and 5. One device failed at 58 days because of thrombus formation at the inflow side of the impeller. The remaining four animals were killed at days 19, 42, 42, and 123, respectively, because of broken electric power cables. Hematocrit values rose significantly higher than preoperative levels (22.8% +/- 3.8% to 30.5% +/- 3.4%); premortem elevations of values higher than baseline values of plasma free hemoglobin (10.4 +/- 7.8 mg/dl to 17.1 +/- 7.4 mg/dl) and lactate dehydrogenase (391.5 +/- 113.7 units/L to 771.2 +/- 370.8 units/L) were statistically insignificant. Serum creatinine and bilirubin levels were normal. No end-organ dysfunction arising from long-term support was evident clinically or at postmortem examination, nor was there any evidence of embolism or damage to intracardiac structures. We found the Jarvik 2000 intraventricular assist device to be easily implantable, safe, nonhemolytic, and able to provide physiologic flow with power requirements under 10 watts.

Adult↗

Jugular venous bulb oxyhemoglobin saturation during cardiac surgery: accuracy and reliability using a continuous monitor.

Previous studies have demonstrated the feasibility of continuously monitoring jugular venous oxygen saturation (SjO2) with a fiberoptic catheter during hypothermic cardiopulmonary bypass (CPB). In the present study, with patients maintained at either moderate (28 degrees C) or mild (32-34 degrees C) hypothermia during CPB, SjO2 values obtained from a fiberoptic catheter were compared to intermittent samples analyzed by a co-oximeter. Twenty patients scheduled for elective coronary artery or valvular surgery had a 5.5 Fr Opticath catheter inserted into the left internal jugular bulb after induction of general anesthesia. The catheter was calibrated in vitro and in vivo according to the manufacturer's specifications. Catheter and co-oximetry SjO2 values obtained at four time points--1) pre-CPB, 2) target CPB temperature, 3) mid-rewarming, and 4) post-CPB--were compared using linear regression, Bland-Altman analysis, and Shrout-Fleiss interclass correlation coefficient analysis. These statistical methods revealed poor correlation between the catheter and co-oximetry SjO2 values: r = 0.44 by linear regression and 0.32 by interclass correlation coefficient analysis, and was unacceptably discrepant by Bland-Altman analysis. Oxyhemoglobin saturation values obtained continuously from a jugular venous bulb fiberoptic catheter during CPB may not accurately reflect true oxyhemoglobin saturation, and caution is warranted when interpreting SjO2 values obtained from a fiberoptic catheter during CPB.

Aged↗

Duration of left ventricular assist device support affects transplant survival.

BACKGROUND: Left ventricular assist devices have become an important tool in the successful treatment of heart failure as bridges to transplantation. The optimal duration of device support before heart transplantation is debated. We report the effect of left ventricular device support duration on survival after heart transplantation. METHODS: All patients bridged to heart transplantation with the ThermoCardiosystems Heartmate 1,000 IP left ventricular assist device between January 1, 1986, and October 15, 1994, were included in our study. Parameters studied included duration of support, measures of end-organ function, and complications while supported with the device. Patients supported < 30 days were compared with patients supported > 30 days before undergoing transplantation. RESULTS: Patients supported for < 30 days had a threefold increased perioperative mortality compared with patients supported > 30 days (p = 0.031). Laboratory values of end-organ function were similar before left ventricular device insertion in both groups, although at the time of transplantation patients supported < 30 days had a significantly elevated bilirubin level compared with patients supported > 30 days (p < 0.001). Patients supported > 30 days had significantly more infections than the < 30 days group (p = 0.0345). CONCLUSIONS: Patients supported for > 30 days with left ventricular assist devices have improved post-transplant perioperative survival because of normalization of end-organ function and improved physiologic status secondary to aggressive physical rehabilitation. Patients should be supported for > 30 days in combination with physical rehabilitation, to improve early survival after heart transplantation.

Adult↗

Immunologic assessment of patients treated with bovine fibrin as a hemostatic agent.

Twenty-one cardiothoracic surgical patients have been treated with fibrin as a topical hemostatic/sealing agent, prepared from bovine fibrinogen clotted with bovine thrombin. Serum samples have been collected before treatment with fibrin and postoperatively between 1 and 9 days, 3 and 12 weeks, and 6 and 8 months. The titers of anti-bovine fibrinogen antibodies, measured by ELISA specific for immunoglobulins IgG or IgM, increased to maximal values after about 8 or 6 weeks, respectively. After 8 months, IgG titers were on average 20-fold lower than the mean maximal value, while IgM titers returned to the normal range. IgG was the predominant anti-bovine fibrinogen immunoglobulin as documented by ELISA, affinity chromatography and electrophoresis. Anti-bovine fibrinogen antibodies present in patients reacted readily with bovine fibrinogen, but did not cross-react with human fibrinogen as measured by ELISA or by immunoelectrophoresis. A significant amount of antibodies against bovine thrombin and factor V has been found, many cross-reacting with the human counterparts. No hemorrhagic or thrombotic complications, or clinically significant allergic reactions, occurred in any patient, in spite of antibody presence against some bovine and human coagulation factors. The treatment of patients with bovine fibrin, without induction of immunologic response against human fibrinogen, appeared to be an effective topical hemostatic/sealing measure.

Animals↗

Transient normalization of systolic and diastolic function after support with a left ventricular assist device in a patient with dilated cardiomyopathy.

A 19-year-old man who had fulminant heart failure caused by an idiopathic dilated cardiomyopathy was supported with a left ventricular assist device for 183 days as a bridge to heart transplantation. At the time of intended transplantation it was noted that the patient's heart had returned to normal size, had a normal ejection fraction, and was able to maintain normal pressures and flows. In view of the apparent recovery of cardiac properties, the left ventricular assist device was explanted and the transplantation was not performed. However, the heart dilated, ejection fraction worsened, and the patient died of heart failure exacerbated acutely by a systemic viral illness. Although such recovery of systolic function is uncommon, as use of the left ventricular assist devices becomes more widespread other physicians might encounter similar findings and, in this regard, they might find our experience useful as they contemplate their treatment options.

Adult↗

Two decades of cardiac transplantation at the Columbia-Presbyterian Medical Center: 1977-1997.

Since its inception in 1977, the Cardiac Transplantation Service at Columbia-Presbyterian Medical Center has performed more than 900 heart transplant procedures, with a one-year survival rate of approximately 80%, and a 5-year survival rate of approximately 60%. Throughout our 20-year experience, the criteria for eligibility both donors and recipients has widened to include older and "reanimated" donors for selected recipients, as well as an extensive experience with recipients bridged to transplantation with mechanical assist devices. Of particular interest in recent years has been the need for additional therapy for the highly sensitized transplant candidate and ultimate transplant recipient, whose immunosuppressive regimen must be continuously monitored and modified to ensure graft survival. In light of the persistent donor organ crisis, continued efforts are being developed to more accurately characterize the transplant candidate waiting list in order to identify those patients who may be better served by either medical management or an alternative surgical procedure to transplantation, including high-risk coronary revascularization and mechanical or biological assistance. Current research interests at CPMC include left ventricular assist devices, xenotransplantation, and management of both transplant coronary artery disease and immunologic sensitization. Ongoing investigations in these and other areas of transplantation have been established to encourage continued growth both within the field and at CPMC through the 21st century.

Adult↗

Screening scale predicts patients successfully receiving long-term implantable left ventricular assist devices.

BACKGROUND: Although use of long-term implantable left ventricular assist devices (LVAD) is becoming more popular, further reduction of the mortality rate accompanying device insertion through improved patient selection would make this alternative even more appealing. We sought to develop a scoring system that was based on criteria obtainable at the time of evaluation and predictive of successful early outcome and simple to apply. METHODS AND RESULTS: Patients (n = 56) undergoing LVAD insertion between 1990 and 1994 were screened for easily obtainable preoperative risk factors. To test the association between survival and each risk factor, a chi 2 analysis was performed, and relative risks were estimated. Oliguria, ventilator dependence, elevated central venous pressure, elevated prothrombin time, and reoperation stats had low probability values and high estimated relative risks. On the basis of these relations, a risk factor-selection scale (RFSS) (range, 0 to 10) was developed by computing appropriate weights for each risk factor. The distribution of patients for each scale score reveal that with RFSS > or = 5, most device recipients will die (P < .001). The average RFSS (+/- SD) of survivors (n = 42) was 2.45 +/- 1.73 compared with 5.43 +/- 2.85 in nonsurvivors (n = 14) (P < .0001). Univariate logistical regression was also significant (score statistic, 16.2; df = 1; P = .001). CONCLUSIONS: The RFSS is simple, easy to apply, and statistically valid. Physicians could use the scale as a starting point in discussing the suitability for LVAD implantation in a specific patient and as a basis for comparing patient outcomes.

Adolescent↗