Microelectrode array for chronic deep-brain microstimulation and recording.

We have developed an array of microelectrodes that is suitable for long-term implantation into the subthalamic nucleus (STN) or the globus pallidus and is able to record from single neurons, as well as deliver localized microstimulation. This device can be used to investigate the mechanisms by which deep brain stimulation can ameliorate the symptoms of Parkinson's disease and other movement disorders, and also may be the basis for a new clinical tool for the treatment of Parkinson's disease, by capitalizing on the high spatial specificity of intranuclear microstimulation. The array includes 16 activated iridium microelectrodes, 5-6 mm in length, within a cluster approximately 1.8 mm in diameter. We have fabricated the array using materials carrying the USP Category VI classification, and we have developed an apparatus and a procedure for implanting the microelectrode arrays into the deep brain. Ten arrays have been implanted into the STN of domestic cats, and one into the internal segment of the globus pallidus, for 140-415 days. During that time, we were able to record action potentials from individual neurons, on 4 to 8 of the 16 channels. The microelectrode' active surface areas ranged from 500 to 2000 microm2. Controlled-current pulses, 26.5 microA in amplitude and 150 micros/phase in duration (4 nC/phase) were used to excite neurons in the cat's STN. In addition to direct activation, the stimulus modulated the neuronal activity over a distance of at least 1.2 mm from the site of stimulation. These parameters did not induce histologically detectable changes around the tip sites after 35 hours of stimulation at 100 Hz (7 hours of stimulation per day, on 5 successive days), if the electrode' active surface area was 1000 microm2 or greater.

Action Potentials↗

Arrays for chronic functional microstimulation of the lumbosacral spinal cord.

Our objective is to develop neural prostheses based on an array of microelectrodes implanted into the sacral spinal cord, that will allow persons with spinal cord injuries to regain control of their bladder and bowels. For our chronic cat model, we have developed two microelectrode arrays, one type containing nine discrete activated iridium microelectrodes and the second utilizing silicon substrate probes with multiple electrode sites on each probe. Both types can elicit an increase in the pressure within the urinary bladder of more than 40-mm Hg and/or relaxation of the urethral sphincter. A stimulus of 100 microA and 400 micros/ph at 20 Hz (charge-balanced pulses) was required to induce a large increase in bladder pressure or relaxation of the urethral sphincter. We found that 24 h of continuous stimulation with these parameters induced tissue injury (disrupted neuropil, infiltration of inflammatory cells, and loss of neurons close to the tip sites). However, a neural prosthesis that is intended to restore bladder control after spinal cord injury would not operate continuously. Thus, when this stimulus was applied for 24 h, at a 10% duty cycle (1 min of stimulation, then 9 min without stimulation) only minimal histologic changes were observed.

Animals↗

A model for intracortical visual prosthesis research.

In the field of visual prosthesis research, it has generally been held that animal models are limited to testing the safety of implantable hardware due to the inability of the animal to provide a linguistic report of perceptions. In contrast, vision scientists make extensive use of trained animal models to investigate the links between visual stimuli, neural activities, and perception. We describe an animal model for cortical visual prosthesis research in which novel animal psychophysical testing has been employed to compensate for the lack of a linguistic report. One hundred and fifty-two intracortical microelectrodes were chronically implanted in area V1 of a male macaque. Receptive field mapping was combined with eye-tracking to develop a reward-based training procedure. The animal was trained to use electrically induced point-flash percepts, called phosphenes, in performing a memory saccade task. It is our long-term goal to use this animal model to investigate stimulation strategies in developing a multichannel sensory cortical interface.

Animals↗