Initial stability of cemented femoral stems as a function of surface finish, collar, and stem size.

BACKGROUND: The optimum surface roughness of cemented femoral stems used for total hip replacement is a subject of controversy. While rougher surfaces provide stronger cement adhesion, it has been hypothesized that polished, tapered, noncollared stems settle into the cement mantle, providing improved stability. However, the effects of surface finish on the stability of straight, cemented stems tapered only in the coronal plane are not known. METHODS: Using composite model femora, we assessed the initial stability of a straight, cemented femoral stem as a function of surface roughness, the presence or absence of a collar, stem size, and the resultant cement thickness under simulated walking and stair-climbing loads. Otherwise identical stems were manufactured with polished or rough surfaces, with or without a collar, in two different sizes. We isolated these three variables and compared their relative contributions to the motion at the stem-cement interface throughout cyclic loading. We defined three indicators of stability: per-cycle motion, rate of migration, and final migration. RESULTS: Surface roughness had a greater influence on per-cycle motions than did the presence or absence of a collar or cement thickness. Specifically, in the medial-lateral direction, per-cycle motion of polished stems was 43 micro m greater than that of rough stems (p < 0.01). None of the per-cycle motions decreased over the 77,000 load cycles. In contrast, with all stems, the rate of migration decreased over the course of cyclic loading, but the rate of migration of the polished stems was greater than that of the rough stems. Final migrations of the stems over the course of loading were generally distal, medial, and into retroversion. Compared with rough stems, polished stems had 8 to 18 micro m more axial migration (p < 0.001), 48 micro m more anterior-posterior migration (p < 0.001), and 0.4 degrees more rotational migration (p = 0.01). CONCLUSIONS: and CLINICAL RELEVANCE: The results indicated that, for cemented, straight femoral stems tapered only in the coronal plane, a rough surface offers the advantage of less per-cycle motion. These results may apply to widely used cemented stem designs based on the profile of the original Charnley femoral component, which has approximately parallel anterior and posterior aspects.

Arthroplasty, Replacement, Hip↗

Effects of dorsal flanges on fixation of a cemented total hip replacement femoral stem.

BACKGROUND: Although current designs of cemented femoral stems for total hip replacement include both those with and those without a flanged shape at the proximal end, the influence of anteroposterior dorsal flanges on the fixation of the stem is not completely understood. The purpose of this study was to assess the effects of flanges on femoral stem stability and load transfer to the femur with use of an in vitro model. METHODS: We measured femoral surface strains and three-dimensional micromotion in synthetic femora under cyclic loading with four types of stems: those with flanges and those without flanges in two sizes each. The four types of stems were otherwise identical; that is, all of them were straight, polished, and collarless. Stem-cement micromotion measurements and strain measurements were repeated with three stems of each type, whereas bone-cement micromotion measurements were made with one stem of each type. RESULTS: Flanges had a greater influence on femoral strains and micromotion than did the difference in the cement thickness resulting from the different stem sizes. Specifically, the flanged stems produced greater strains on the medial femoral surface but smaller strains on the anterior surface than did the non-flanged stems. Flanged stems achieved tighter mechanical interlock within the cement, but these stems increased bone-cement micromotion. Specifically, the motion per cycle of flanged stems within the cement mantle was smaller than that of non-flanged stems, whereas the motion per cycle of the cement mantle within the femoral canal was greater with the flanged stems than with the non-flanged stems. CONCLUSIONS: Flanges on a total hip femoral stem increase the interlock between the stem and the cement and decrease the proximal-medial stress-shielding. However, these advantages occur with increased bone-cement interface motion, which may be detrimental to the survival of the implant.

Adult↗

Polyethylene liner cementation into fixed acetabular shells.

A patient presenting with a secure cementless acetabular component and with femoral head penetration through the polyethylene liner is a common clinical problem. Cementing a new liner into the fixed shell is one option. We evaluated this option in a clinical series of 17 cases and with a preliminary mechanical study. In the 1 clinical failure (5.9%), the failure occurred at the cement-liner interface. The most important variable in optimizing the mechanical strength of the cemented liner construct was adequate preparation of the cement-liner interface. This approach to treating the patient with a fixed cementless shell and a worn polyethylene liner can provide a durable construct with minimal morbidity.

Aged↗