Search PubMed⌕ Search

Biomedical subjects

Dino Di Carlo

Publications and source records attributed to Dino Di Carlo.

6 recordsLinked to original sources

Dynamic single cell culture array.

It is important to quantify the distribution of behavior amongst a population of individual cells to reach a more complete quantitative understanding of cellular processes. Improved high-throughput analysis of single cell behavior requires uniform conditions for individual cells with controllable cell-cell interactions, including diffusible and contact elements. Uniform cell arrays for static culture of adherent cells have previously been constructed using protein micropatterning techniques but lack the ability to control diffusible secretions. Here we present a microfluidic-based dynamic single cell culture array that allows both arrayed culture of individual adherent cells and dynamic control of fluid perfusion with uniform environments for individual cells. In our device no surface modification is required and cell loading is done in less than 30 seconds. The device consists of arrays of physical U-shaped hydrodynamic trapping structures with geometries that are biased to trap only single cells. HeLa cells were shown to adhere at a similar rate in the trapping array as on a control glass substrate. Additionally, rates of cell death and division were comparable to the control experiment. Approximately 100 individual isolated cells were observed growing and adhering in a field of view spanning approximately 1 mm(2) with greater than 85% of cells maintained within the primary trapping site after 24 hours. Also, greater than 90% of cells were adherent and only 5% had undergone apoptosis after 24 hours of perfusion culture within the trapping array. We anticipate uses in single cell analysis of drug toxicity with physiologically relevant perfused dosages as well as investigation of cell signaling pathways and systems biology.

Cell Adhesion↗

Single-cell enzyme concentrations, kinetics, and inhibition analysis using high-density hydrodynamic cell isolation arrays.

High-quality single-cell data are required for a quantitative systems biology description of cellular function. However, data of this type are difficult and time-consuming to collect using traditional techniques. We present a robust and simple microfluidic method for trapping single cells in large arrays to address this problem. Ordered single-cell isolation arrays allow for high-density microscopic analysis with simplified image processing. Moreover, for fluorescent assays, on-chip sample preparation (e.g., fluorescent labeling, washing) can be performed, as opposed to manual intensive operations of incubation, centrifugation, and resuspension in previous techniques-saving time and reagents. This technology was applied to determine novel single-cell enzyme kinetics for three different cell types (HeLa, 293T, Jurkat). A kinetic model of this process predicted this varied response was due to variation in the concentration of carboxylesterase between cell types. Nordihydroguaiaretic acid (NDGA) was also characterized as an inhibitor of carboxylesterases. For HeLa cells, 20 nM of the 50 nM total carboxylesterases was unaffected by NDGA. This type of analysis could be directly applied to quantify a variety of intracellular enzymes with available fluorogenic substrates.

Carboxylesterase↗

Alkaline hemolysis fragility is dependent on cell shape: results from a morphology tracker.

BACKGROUND: The morphometric analysis of red blood cells (RBCs) is an important area of study and has been performed previously for fixed samples. We present a novel method for the analysis of morphologic changes of live erythrocytes as a function of time. We use this method to extract information on alkaline hemolysis fragility. Many other toxins lyse cells by membrane poration, which has been studied by averaging over cell populations. However, no quantitative data are available for changes in the morphology of individual cells during membrane poration-driven hemolysis or for the relation between cell shape and fragility. METHODS: Hydroxide, a porating agent, was generated in a microfluidic enclosure containing RBCs in suspension. Automatic cell recognition, tracking, and morphometric measurements were done by using a custom image analysis program. Cell area and circular shape factor (CSF) were measured over time for individual cells. Implementations were developed in MATLAB and on Kestrel, a parallel computer that affords higher speed that approaches real-time processing. RESULTS: The average CSF went through a first period of fast increase, corresponding to the conversion of discocytes to spherocytes under internal osmotic pressure, followed by another period of slow increase until the fast lysis event. For individual cells, the initial CSF was shown to be inversely correlated to cell lifetime (linear regression factor R=0.44), with discocytes surviving longer than spherocytes. The inflated cell surface area to volume ratio was also inversely correlated to lifetime (R=0.43) but not correlated to the CSF. Lifetime correlated best to the ratio of cell inflation volume (Vfinal-Vinitial) to surface area (R=0.65). CONCLUSIONS: RBCs inflate at a rate proportional to their surface area, in agreement with a constant flux model, and lyse after attaining a spherical morphology. Spherical RBCs display increased alkaline hemolysis fragility (shorter lifetimes), providing an explanation for the increased osmotic fragility of RBCs from patients who have spherocytosis.

Cell Shape↗

On-chip cell lysis by local hydroxide generation.

We present a novel method for on-chip cell lysis based on local hydroxide electro-generation. Hydroxide ions porate the cell membrane, leading to cell lysis. After lysis occurs, hydrogen ions, also generated on chip, react with excess hydroxide, creating a neutral pH lysate and eliminating the need for a wash step. Three different cell types are shown to be effectively lysed by this method: red blood cells, HeLa (human tumor line) and Chinese Hamster Ovary (CHO) cell lines. The release of cytoplasmic molecules from HeLa and CHO cells is demonstrated by monitoring the escape of a membrane impermeant dye from the cytoplasm. In the vicinity of the cathode, the hydroxide concentration is predicted by finite element simulations and shown to fit the lysis rates at different distances from the generating cathode. For flow-through experiments, a second device integrating a mechanical filter with hydroxide generation is fabricated and tested. The purpose of the filter is to trap whole cells and only allow lysate to pass through. The flow rate dependence of hydroxide concentration at the lysis filter is modeled and lysis efficiency is experimentally determined to be proportional to the hydroxide concentration for flow rates from 15 to 30 microl min(-1).

Animals↗

Reagentless mechanical cell lysis by nanoscale barbs in microchannels for sample preparation.

A highly effective, reagentless, mechanical cell lysis device integrated in microfluidic channels is reported. Sample preparation, specifically cell lysis, is a critical element in 'lab-on-chip' applications. However, traditional methods of cell lysis require purification steps or complicated fabrication steps that a simple mechanical method of lysis may avoid. A simple and effective mechanical cell lysis system is designed, microfabricated, and characterized to quantify the efficiency of cell lysis and biomolecule accessibility. The device functionality is based on a microfluidic filter region with nanostructured barbs created using a modified deep reactive ion etching process. Mechanical lysis is characterized by using a membrane impermeable dye. Three main mechanisms of micro-mechanical lysis are described. Quantitative measurements of accessible protein as compared to a chemically lysed sample are acquired with optical absorption measurements at 280 and 414 nm. At a flow rate of 300 microL min(-1) within the filter region total protein and hemoglobin accessibilities of 4.8% and 7.5% are observed respectively as compared to 1.9% and 3.2% for a filter without nanostructured barbs.

Animals↗