Quantification of regional left ventricular wall motion from real-time 3-dimensional echocardiography in patients with poor acoustic windows: effects of contrast enhancement tested against cardiac magnetic resonance.

OBJECTIVE: Regional left ventricular function can be assessed by real-time 3-dimensional echocardiography (RT3DE) in patients with good image quality. Our goals were to: (1) test the feasibility of RT3DE quantification of regional wall motion (RWM) in patients with poor acoustic windows who require contrast for endocardial visualization; and (2) validate these measurements against cardiac magnetic resonance (CMR) reference. METHODS: RT3DE datasets and CMR images were obtained in 24 patients. In 16 of 24 patients with suboptimal endocardial definition, RT3DE imaging was repeated with intravenous contrast and triggering at end systole and end diastole. RT3DE datasets were analyzed using custom software designed to semiautomatically detect and segment the endocardial surface and calculate RWM values. CMR images were analyzed using commercial software to obtain reference values for RWM. RESULTS: In 8 of 24 patients with good endocardial definition, RT3DE values of RWM correlated well with CMR (r = 0.73) with a small bias (-1.0 mm). In the remaining 16 patients, analysis of nonenhanced RT3DE datasets yielded lower correlation with CMR (r = 0.61) and a slightly greater bias (-1.5 mm). The agreement with CMR improved significantly (r = 0.76, bias -1.1 mm) with contrast enhancement. CONCLUSIONS: The agreement between RT3DE and CMR values of RWM is directly related to RT3DE image quality. In patients with poor acoustic windows, dual-triggered contrast enhancement improves the accuracy of RWM quantification to a level similar to that noted in patients with good images without contrast.

Computer Systems↗

PHACES association.

Explore the source record for details and available documents.

Abnormalities, Multiple↗

Automated interpretation of regional left ventricular wall motion from cardiac magnetic resonance images.

UNLABELLED: Magnetic resonance (MR) diagnosis of regional left ventricular (LV) dysfunction relies on visual interpretation of cine images that suffers from wide inter-observer variability, especially when performed by readers not specifically trained in the assessment of LV wall motion. Quantitative analysis tools, though widely available, are rarely used because they provide large amounts of detailed information, the interpretation of which requires additional time-consuming processing. We tested the feasibility of fast automated interpretation of regional LV function using computer analysis of this wall motion information. METHODS: Dynamic, ECG-gated, steady-state free precession short-axis images were obtained in 6-10 slices in 28 subjects (10 normal volunteers; 18 patients). Images were reviewed by an expert cardiologist who provided "gold standard" grades (normal, abnormal) for regional wall motion and, independently, by four radiologists. Same images were then analyzed using custom software. Regional fractional area changes computed in normal volunteers were used to obtain the optimal segment- and slice-specific threshold values for automated classification of regional wall motion for each patient. The levels of agreement with the "gold standard" grades were compared between the radiologists and the automated interpretation. RESULTS: While the visual interpretation required 2-5 minute per patient, the automated interpretation required < 1 sec, after endocardial border detection was complete. The automated interpretation resulted in higher sensitivity, specificity, and accuracy (84%, 77%, 79%, respectively) than the radiologists' grades (80%, 76%, 77%, respectively) and eliminated the high interobserver variability. CONCLUSION: Once the endocardial boundaries are defined, computer analysis of the regional wall motion information allows accurate, fully automated, immediate, objective and experience-independent interpretation of regional LV function.

Automation↗

Rapid online quantification of left ventricular volume from real-time three-dimensional echocardiographic data.

AIMS: Determination of left ventricular (LV) volumes and ejection fraction (EF) from two-dimensional echocardiographic (2DE) images is subjective, time-consuming, and relatively inaccurate because of foreshortened views and the use of geometric assumptions. Our aims were (1) to validate a new method for rapid, online measurement of LV volumes from real-time three-dimensional echocardiographic (RT3DE) data using cardiac magnetic resonance (CMR) as the reference and (2) to compare its accuracy and reproducibility with standard 2DE measurements. METHODS AND RESULTS: CMR, 2DE, and RT3DE datasets were obtained in 50 patients. End-systolic and end-diastolic volumes (ESV and EDV) were calculated from the 2DE images using biplane method of disks. ES and ED RT3DE datasets were analysed using prototype software designed to automatically detect the endocardial surface using a deformable shell model and calculate ESV and EDV from voxel counts. 2DE and RT3DE-derived volumes were compared with CMR (linear regression, Bland-Altman analysis). In most patients, analysis of RT3DE data required <2 min per patient. RT3DE measurements correlated highly with CMR (r: 0.96, 0.97, and 0.93 for EDV, ESV, and EF, respectively) with small biases (-14 mL, -6.5 mL, -1%) and narrow limits of agreement (SD: 17 mL, 16 mL, 6.4%). 2DE measurements correlated less well with CMR (r: 0.89, 0.92, 0.86) with greater biases (-23 mL, -15 mL, 1%) and wider limits of agreement (SD: 29 mL, 24 mL, 9.5%). RT3DE resulted in lower intra-observer (EDV: 7.9 vs. 23%; ESV: 7.6 vs. 26%) and inter-observer variability (EDV: 11 vs. 26%; ESV: 13 vs. 31%). CONCLUSION: Semi-automated detection of the LV endocardial surface from RT3DE data is suitable for clinical use because it allows rapid, accurate, and reproducible measurements of LV volumes, superior to conventional 2DE methods.

Echocardiography, Three-Dimensional↗

Dual triggering improves the accuracy of left ventricular volume measurements by contrast-enhanced real-time 3-dimensional echocardiography.

Real-time 3-dimensional echocardiographic continuous imaging (CIM) with contrast underestimates left ventricular (LV) volumes. We studied the effects of dual-triggered (DT) acquisition on the accuracy of LV volume measurements for patients with poor acoustic windows. Real-time 3-dimensional echocardiographic imaging was performed in 20 patients during LV opacification (Definity) on the same day as cardiac magnetic resonance imaging. Both CIM and DT data were analyzed using custom software to calculate end-systolic volume (ESV) and end-diastolic volume (EDV), which were compared with the cardiac magnetic resonance reference. CIM correlated well with the cardiac magnetic resonance reference (EDV: r = 0.89; ESV: r = 0.93), but underestimated EDV and ESV by 17% and 19%, respectively. In contrast, DT resulted in higher correlation (EDV: r = 0.95; ESV: r = 0.96) and smaller biases (9% and 6%, respectively). In conclusion, because the accuracy of LV volume measurements depends on the acquisition strategy of contrast-enhanced real-time 3-dimensional echocardiographic images, the use of DT instead of the conventional CIM acquisition is recommended.

Computer Systems↗

Improved quantification of left ventricular volumes and mass based on endocardial and epicardial surface detection from cardiac MR images using level set models.

PURPOSE: The reproducibility of left ventricular (LV) volume and mass measurements based on subjective slice-by-slice tracing of LV borders is affected by image quality, and volume estimates are biased by geometric modeling. The authors developed a technique for volumetric surface detection (VoSD) and quantification of LV volumes and mass without tracing and geometric approximations. The authors hypothesized that this technique is accurate and more reproducible than the conventional methodology. METHODS: Images were obtained in 24 patients in 6 to 10 slices from LV base to apex (GE 1.5 T, FIESTA). Volumetric data were reconstructed, and endocardial and epicardial surfaces were detected using the level set approach. LV volumes were obtained from voxel counts and used to compute ejection fraction (EF) and mass. Conventional measurements (MASS Analysis) were used as a reference to test the accuracy of VoSD technique (linear regression, Bland-Altman). For both techniques, measurements were repeated to compute inter- and intra-observer variability. RESULTS: VoSD values resulted in high correlation with the reference values (EDV: r = 0.98; ESV: r = 0.99; EF: r = 0.91; mass: r = 0.98), with no significant biases (8 ml, 5 ml, 0.2% and -9 g) and narrow limits of agreement (SD: 13 ml, 10 ml, 6% and 9 g). Inter-observer variability of the VoSD technique was lower (range 3 to 5%) than that of the reference technique (5 to 11%; p < 0.05). Intra-observer variability was also lower (1 to 3% vs. 7 to 10%; p < 0.05). CONCLUSION: VoSD technique allows accurate measurements of LV volumes, EF, and mass, which are more reproducible than the conventional methodology.

Cardiac Volume↗