Search PubMed⌕ Search

Biomedical subjects

David Sinton

Publications and source records attributed to David Sinton.

7 recordsLinked to original sources

Electroosmotic flow with Joule heating effects.

Electroosmotic flow with Joule heating effects was examined numerically and experimentally in this work. We used a fluorescence-based thermometry technique to measure the liquid temperature variation caused by Joule heating along a micro capillary. We used a caged-fluorescent dye-based microfluidic visualization technique to measure the electroosmotic velocity profile along the capillary. Sharp temperature drops close to the two ends and a high-temperature plateau in the middle of the capillary were observed. Correspondingly, concave-convex-concave velocity profiles were observed in the inlet-middle-outlet regions of a homogeneous capillary. These velocity perturbations were due to the induced pressure gradients resulting from axial variations of temperature. The measured liquid temperature distribution and the electroosmotic velocity profile along the capillary agree well with the predictions of a theoretical model developed in this paper.

Journal Article↗

A miniaturized high-voltage integrated power supply for portable microfluidic applications.

In this work a portable microfluidic device with a reusable integrated high voltage power supply is presented, which allows for quick exchange of inexpensive disposable poly(dimethylsiloxane)(PDMS) microfluidic chips on a carrier only slightly larger than a microscope slide. The device is powered by an onboard MN21 cell battery (5 mm radius, 30 mm long) and is demonstrated through the rapid and controlled transport of a fluorescent dye through an expansion chamber geometry. Power consumption experiments demonstrate the device's ability to complete over 40 dispense-flushing cycles on a single battery.

Dimethylpolysiloxanes↗

A dynamic loading method for controlling on-chip microfluidic sample injection.

A new technique for controlling discrete sample injection in straight-cross microfluidic chips is presented here. This technique involves a three-part process with a dynamic loading step in between the steady-state loading step and the dispensing step. During the intermediate step, sample is pumped into the intersection and into the three connecting channels. The key features of this technique are the ability to dynamically control the sample size and the ability to inject well-defined samples at the original sample concentration. Injections of these samples with lengths varying from 2 channel widths (100 microm) to 20 channel widths (millimeter-sized) are demonstrated. The sample concentration profiles obtained are compared with those of focused and less-focused pinched-valve injections. In applications such as high-speed capillary zone electrophoresis, this technique can provide an increase in signal with a small increase in sample length. This technique is especially applicable to many large-sample applications in which the offset twin-T microchip has been previously employed.

Journal Article↗

Joule heating and heat transfer in poly(dimethylsiloxane) microfluidic systems.

Joule heating is a significant problem in electrokinetically driven microfluidic chips, particularly polymeric systems where low thermal conductivities amplify the difficulty in rejecting this internally generated heat. In this work, a combined experimental (using a microscale thermometry technique) and numerical (using a 3D "whole-chip" finite element model) approach is used to examine Joule heating and heat transfer at a microchannel intersection in poly(dimethylsiloxane)(PDMS), and hybrid PDMS/Glass microfluidic systems. In general the numerical predictions and the experimental results agree quite well (typically within +/- 3 degree C), both showing dramatic temperature gradients at the intersection. At high potential field strengths a nearly five fold increase in the maximum buffer temperature was observed in the PDMS/PDMS chips over the PDMS/Glass systems. The detailed numerical analysis revealed that the vast majority of steady state heat rejection is through lower substrate of the chip, which was significantly impeded in the former case by the lower thermal conductivity PDMS substrate. The observed higher buffer temperature also lead to a number of significant secondary effects including a near doubling of the volume flow rate. Simple guidelines are proposed for improving polymeric chip design and thereby extend the capabilities of these microfluidic systems.

Computer Simulation↗

Effects of liquid conductivity differences on multi-component sample injection, pumping and stacking in microfluidic chips.

As an increasing number of processes are being integrated into Lab-on-a-chip devices, there is an increasing need for flexible and accurate sample manipulation techniques for effective transport and separation. Conductivity differences between running buffer and analyte samples can arise as a product of on-chip processing, or by design. The two situations studied here are sample pumping (where bulk transport is increased and separation of charged analytes is delayed using a relatively high conductivity sample), and sample stacking (where bulk transport is decreased and separation of charged analytes is expedited using a relatively low conductivity sample). A recently developed dynamic loading method for on-chip sample injection in a straight-cross channel configuration is applied here to both pumping and stacking cases. A key characteristic of the dynamic loading method is the ability to inject samples of high concentration density and uniformity of any length. By employing the conductivity differences alone, the effectiveness of either sample transport or sample separation are shown to improve over the uniform conductivity case. Then it is demonstrated that increasing the sample length, through dynamic loading, greatly increases the effectiveness of sample pumping, evidenced in an eight-fold increase in peak height as well as a decrease in total sample length at a downstream detector. Dynamic loading in the sample stacking case was shown to also increase peak intensity height (three-fold) in rapid separations. These results demonstrate that the dynamic loading technique, used in conjunction with strategic conductivity differences, significantly extends the capabilities of microfluidic chips.

Journal Article↗

Visualization and numerical modelling of microfluidic on-chip injection processes.

Sample injection processes accomplished using a microfluidic-cross chip are investigated experimentally and numerically. Fluorescent dye is employed to differentiate the sample solution from the pure buffer. Different sample geometries are achieved using different applied electric fields and dyes with different electrophoretic mobilities. Of particular interest here are concentration-dense samples with large axial extent (extending beyond the intersection). The ability to load and subsequently dispense these large axial extent samples is predicted numerically and verified experimentally by direct visualization. Containing more mass, larger samples exhibited lower concentration gradients, making them less sensitive to diffusion and well-suited to transport once dispensed. In the loading process, however, larger samples were found to be more sensitive to pressure effects than more focused samples. This was investigated by imaging sample geometries under various applied fields in the presence of a constant pressure gradient. Laplace pressure originating from differential meniscus curvatures in the reservoirs was found to be the most significant source of such pressure disturbances in these geometries.

Journal Article↗

Direct and indirect electroosmotic flow velocity measurements in microchannels.

As microfluidic technologies mature, increasingly complex solutions are employed, and accurate methods for the measurement of electroosmotic flow rates are becoming increasingly important. The methodologies of both a direct method and an indirect method of flow rate measurement are presented here. The direct method involves flow visualization using trace amounts of a caged fluorescent dye. The indirect method is based on the change in current that occurs when one solution in the microchannel is replaced by another. The results of concurrent and independent measurements of electroosmotic velocities of Tris-acetate with EDTA (TAE) and Tris-borate with EDTA (TBE) at 1x concentration in fused silica capillaries are presented. Although these buffers are commonly used in biological chemistry, these mobilities have not previously been reported. Strong agreement among data collected with both methods establishes confidence in the electroosmotic mobility values obtained and indicates that the current-based method, which requires less infrastructure than the direct method, can provide accurate flow rate measurements under these conditions. Constant electroosmotic mobilities of 4.90 x 10(-8) m(2) V(-1) s(-1) for TAE and 3.10 x 10(-8) m(2) V(-1) s(-1) for TBE were determined by tests in a range of electrical field strengths from 5 to 20 kV/m. A linear flow rate increase with applied field strength indicated that constant mobility and negligible Joule heating effects were present. Applicability and limitations of both the measurement methods and these buffers are discussed in the context of microfluidic applications.

Journal Article↗