Search PubMed⌕ Search

Biomedical subjects

David S Margolis

Publications and source records attributed to David S Margolis.

4 recordsLinked to original sources

Functionally improved bone in calbindin-D28k knockout mice.

In vitro studies indicate that Calbindin-D28k, a calcium binding protein, is important in regulating the life span of osteoblasts as well as the mineralization of bone extracellular matrix. The recent creation of a Calbindin-D28k knockout mouse has provided the opportunity to study the physiological effects of the Calbindin-D28k protein on bone remodeling in vivo. In this experiment, histomorphometry, microCT, and bend testing were used to characterize bones in Calbindin-D28k KO (knockout) mice. The femora of Calbindin-D28k KO mice had significantly increased cortical bone volume (60.4% +/- 3.1) compared to wild-type (WT) mice (45.4% +/- 4.6). The increased bone volume was due to a decrease in marrow cavity area, and significantly decreased endosteal perimeters (3.397 mm +/- 0.278 in Calbindin-D28k KO mice, and 4.046 mm +/- 0.450 in WT mice). Similar changes were noted in the analysis of the tibias in both mice. The bone formation rates were similar in the femoral and tibial cortical bones of both mice. microCT analysis of the trabecular bone in the tibial plateau indicated that Calbindin-D28k KO mice had an increased bone volume (35.2% +/- 3.1) compared to WT mice (24.7% +/- 4.9) which was primarily due to increased trabecular number (8.99 mm(-1) +/- 0.94 in Calbindin-D28k KO mice compared to 6.75 mm(-1) +/- 0.85 in WT mice). Bone mineral content analysis of the tibias indicated that there is no difference in the calcium or phosphorus content between the Calbindin-D28k KO and WT mice. Cantilever bend testing of the femora demonstrated significantly lower strains in the bones of Calbindin-D28k KO mice (4135 micro strain/kg +/- 1266) compared to WT mice (6973 micro strain/kg +/- 998) indicating that the KO mice had stiffer bones. Three-point bending demonstrated increased failure loads in bones of Calbindin-D28k KO mice (31.6 N +/- 2.1) compared to WT mice (15.0 N +/- 1.7). In conclusion, Calbindin-D28k KO mice had increased bone volume and stiffness indicating that Calbindin-D28k plays an important role in bone remodeling.

Animals↗

In vivo strain measurements from hardware and lamina during spine fusion.

Currently, spine fusion is determined using radiography and clinical evaluation. There are discrepancies between radiographic evidence and direct measurements of fusion, such as operative exploration and biomechanical or histological measurements. In order to facilitate the rapid return of patients to normal activities, a monitoring technique to accurately detect fusion in vivo and to prevent overload during the postoperative period would be useful. The objectives of this study were to develop an implantable monitoring system consisting of CPC-coated strain gauges and a radio transmitter to detect the onset of fusion and measure strain during postsurgical activities. A patient underwent anterior release and fusion, followed by posterior instrumentation and fusion with segmental spinal instrumentation. Four strain gauges were placed during surgery. One was attached to the left-side rod and one to each of the lamina at T9, T10, and T11. An externally powered implanted radio transmitter attached to the gauges was placed in a subcutaneous pouch. Strains were monitored weekly and tabulated during various activities for 7 months. Peak strains during twisting and bending were tabulated to detect the onset of fusion. Strains were also recorded during activities such as climbing off an examination table, rising from a chair, and climbing stairs. Strains collected from the left rod indicated that, immediately postoperatively, it was loaded at acceptable levels. The largest and most consistent strain changes measured from the lamina were recorded during twisting.

Adolescent↗

Bilateral symmetry of biomechanical properties in mouse femora.

Bone healing and remodeling are commonly examined in animal models by comparing one femur (experimental) to the contralateral femur (control) with the assumption that they are identical with respect to their biomechanical properties. While past studies have characterized the symmetry in geometrical properties in many types of animal bones, few studies have compared the symmetry in the biomechanical properties. The purpose of this study was to determine whether there is symmetry in the mechanical properties of mouse femora. Strain gauges were attached to the posterior surface of the femora of C57BL/6 mice, parallel to the long axis of the bone. The femora were mechanically tested in cantilever bending while strain values were recorded. Moments of inertia, cortical areas, and moduli of elasticity were determined from strains and cross-sectional properties. Mouse femora demonstrated an average strain difference of 0.4% in tension and 1.4% in compression. Elastic moduli differed by 6.6% and 0.9% in tension and compression, respectively, and failure strength differed by an average of 2.0%. Statistical analysis showed there were no significant differences in strain, modulus, or failure load values for the mice, indicating mechanical and geometrical symmetry of mouse femora in cantilever bending.

Anatomy, Cross-Sectional↗

Evaluation of a new CPC-to-gauge bonding technique with the use of in vitro fluid flow.

Strain gauging enables the measurement of bone deformation during physical activity, leading to a better understanding of the physiological effects of loading on bone growth and remodeling. Development of a technology that will withstand long-term in vivo exposure and bond securely to bone is imperative for accurate, consistent measurement collection. Polysulfone is currently used to attach calcium-phosphate ceramic (CPC) particles, which promote bone-to-gauge bonding, to polyimide-backed strain gauges. This study evaluated the use of an implant-grade epoxy as an alternative CPC-polyimide adhesive. Polyimide-epoxy-CPC interfaces were loaded to failure and shear strengths calculated. In vitro studies providing a constant flow of medium over test specimens were designed, and long-term in vitro fluid exposure studies of the epoxy's shear strength were conducted. Average shear strength of polysulfone-polyimide interfaces were reported to be 7 MPa. The average shear strength of the epoxy-polyimide interface before long-term in vitro exposure was 17 MPa, which is stronger than the shear strength of the bone-CPC interface. The strength of the epoxy-polyimide interface decreased to 6.8 MPa after 24 weeks in vitro and 3 MPa after 24 weeks in vivo.

Animals↗