Search PubMed⌕ Search

Biomedical subjects

David S Greenfield

Publications and source records attributed to David S Greenfield.

At least 19 recordsLinked to original sources

Association Between 24-Hour Blood Pressure and Rates of Retinal Nerve Fiber Layer Progression in Glaucoma: The Vascular Imaging in Glaucoma Study.

PURPOSE: Low systemic blood pressure (BP) has been implicated as a risk factor for glaucoma progression. The purpose of this study was to investigate the association between 24-hour BP and rates of retinal nerve fiber layer (RNFL) loss in eyes with primary open-angle glaucoma. DESIGN: Prospective cohort study. PARTICIPANTS: Seventy-nine eyes from 42 subjects with glaucoma (mean age, 68.5 &#xb1; 7.6 years) enrolled in the Vascular Imaging in Glaucoma Study at the Bascom Palmer Eye Institute. METHODS: Participants underwent 24-hour ambulatory BP monitoring at baseline. Follow-up evaluations were conducted at 4-month intervals and included ophthalmic examination, BP measurement, and peripapillary RNFL thickness measurement with spectral-domain optical coherence tomography. The association between BP and RNFL loss over time was assessed using linear mixed-effects models adjusted for age, sex, race, baseline RNFL thickness, central corneal thickness, and intraocular pressure. MAIN OUTCOME MEASURES: The effect of baseline 24-hour mean arterial pressure (MAP), systolic BP (SBP), and diastolic BP (DBP) on the rate of average RNFL loss over time. RESULTS: Eyes underwent an average of 13 &#xb1; 3 optical coherence tomography exams over 43 &#xb1; 10 months of follow-up. The mean rate of RNFL loss was -0.34 &#xb1; 0.64 &#xb5;m/y (median: -0.32; interquartile range: -0.66 to -0.04 &#xb5;m/y). After adjusting for confounding factors, every 10 mm Hg lower in 24-hour minimum MAP, SBP, and DBP was associated with -0.542 &#xb5;m/y (P < .001), -0.360 &#xb5;m/y (P = .003), and -0.458 &#xb5;m/y (P = .008) faster RNFL loss, respectively. Eyes in the lowest quartile of average 24-hour MAP (81-90 mm Hg) and minimum 24-hour DBP (35-47 mm Hg) experienced significantly faster progression compared to those in the highest quartile, with differences of -0.68 &#xb5;m/y (P = .017) and -0.63 &#xb5;m/y (P = .030), respectively. CONCLUSIONS: Lower systemic BP, especially minimum MAP, SBP, and DBP measured by 24-hour ambulatory BP monitoring, is associated with faster rates of RNFL loss in primary open-angle glaucoma eyes. 24-hour BP monitoring may help predict glaucoma patients at greater risk of progression.

Humans↗

Determinants of normal retinal nerve fiber layer thickness measured by Stratus OCT.

PURPOSE: To determine the effects of age, optic disc area, ethnicity, eye, gender, and axial length on the retinal nerve fiber layer (RNFL) in the normal human eye as measured by Stratus OCT (optical coherence tomography). DESIGN: Cross-sectional observational study. PARTICIPANTS: Three hundred twenty-eight normal subjects 18 to 85 years old. METHODS: Peripapillary Fast RNFL scans performed by Stratus OCT with a nominal diameter of 3.46 mm centered on the optic disc were performed on one randomly selected eye of each subject. MAIN OUTCOME MEASURES: Linear regression analysis of the effects of age, ethnicity, gender, eye, axial length, and optic disc area on peripapillary RNFL thickness. RESULTS: The mean RNFL thickness for the entire population was 100.1 microm (standard deviation, 11.6). Thinner RNFL measurements were associated with older age (P<0.001); being Caucasian, versus being either Hispanic or Asian (P = 0.006); greater axial length (P<0.001); or smaller optic disc area (P = 0.010). For every decade of increased age, mean RNFL thickness measured thinner by approximately 2.0 microm (95% confidence interval [CI], 1.2-2.8). For every 1-mm-greater axial length, mean RNFL thickness measured thinner by approximately 2.2 microm (95% CI, 1.1-3.4). For every increase in square millimeter of optic disc area, mean RNFL thickness increased by approximately 3.3 microm (95% CI, 0.6-5.6). Comparisons between ethnic groups revealed that Caucasians had mean RNFL values (98.1+/-10.9 microm) slightly thinner than those of Hispanics (103.7+/-11.6 microm; P = 0.022) or Asians (105.8+/-9.2 microm; P = 0.043). There was no relationship between RNFL thickness and eye or gender. CONCLUSIONS: Retinal nerve fiber layer thickness, as measured by Stratus OCT, varies significantly with age, ethnicity, axial length, and optic disc area. These variables may need to be taken into account when evaluating patients for diagnosis and follow-up of glaucoma, particularly at the lower boundary of the normal range. Due to the relatively small numbers of subjects of Asian and African descent in the normative database, conclusions regarding the effect of ethnicity should be interpreted with caution.

Adolescent↗

Visual field and intraocular pressure asymmetry in the low-pressure glaucoma treatment study.

OBJECTIVE: To explore the relationship between asymmetric baseline intraocular pressure (IOP) and asymmetric visual field (VF) loss in the Low-Pressure Glaucoma Treatment Study. DESIGN: Randomized, multicenter, controlled clinical trial. PARTICIPANTS: Low-pressure glaucoma (LPG) patients 30 years or older were identified. Exclusion criteria included an untreated pressure > 21 mmHg, advanced VF loss, and contraindications to study medications. INTERVENTIONS: A baseline VF was created using the average of 2 reliable Humphrey full-threshold examinations. A baseline diurnal IOP curve was performed without IOP-lowering medication. MAIN OUTCOME MEASURES: Mean diurnal, peak, trough, IOP range (peak - trough), and standard deviation (SD) of IOP measurements, and mean deviation (MD) and corrected pattern SD (CPSD) of VF examinations. RESULTS: One hundred ninety patients were enrolled (mean age, 64.9+/-10.7 years). Mean deviation and CPSD were not correlated with mean, peak, trough, or peak minus trough (P - T) IOP (Ps = 0.2-0.9). Among patients with unilateral VF loss (n = 53 [27.9%]), there were no differences (Ps = 0.3-0.9) in any IOP parameter between the normal VF eye and fellow glaucomatous eyes. Among patients with bilateral VF loss (n = 137 [72.1%]), mean, peak, trough, and P - T IOPs were similar in eyes with a better VF MD compared with eyes with a worse VF MD (Ps = 0.2-0.7). Cross-classified contingency tables demonstrated no relationship (Ps = 0.1-0.3) between IOP and VF MD or CPSD using chi-square analysis. CONCLUSIONS: Intraocular pressure asymmetry is unrelated to VF asymmetry in the Low-Pressure Glaucoma Treatment Study, suggesting an unclear pathogenic relationship between IOP and glaucomatous damage in eyes with LPG.

Adrenergic alpha-Agonists↗

Scanning laser polarimetry with variable and enhanced corneal compensation in normal and glaucomatous eyes.

PURPOSE: To investigate whether correction for atypical birefringence pattern (ABP) using scanning laser polarimetry with enhanced corneal compensation (SLP-ECC) reduces the severity of ABP compared with variable corneal compensation (SLP-VCC) and improves the correlation with visual function. DESIGN: Prospective observational study. METHODS: Normal and glaucomatous eyes enrolled from four clinical sites underwent complete examination, automated perimetry, SLP-ECC, and SLP-VCC. Eyes were characterized in three groups based upon the typical scan score (TSS): normal birefringence pattern (NBP) was defined as TSS > or = 80, mild ABP as TSS 61 to 79, and moderate-severe ABP as TSS < or = 60. For each of four SLP parameters, the area under the ROC curve (AUROC) was calculated to compare the ability of SLP-ECC and SLP-VCC to discriminate between normal and glaucomatous eyes. RESULTS: Eighty-four normal volunteers and 45 glaucoma patients were enrolled. Mean TSS was significantly (P < .001) greater using SLP-ECC (98.0 +/- 6.6) compared with SLP-VCC (83.4 +/- 22.5). The frequency of moderate-severe ABP images was significantly (P < .001, McNemar test) higher using SLP-VCC (18 of 129, 14%) compared with SLP-ECC (one of 129, 0.8%). Two SLP-ECC parameters (temporal superior nasal inferior temporal [TSNIT] average and inferior average) had significantly (P = .01, P < .001) higher correlation (r = .45, r = .50, respectively) with MD compared with SLP-VCC (r = .34, r = .37). Among eyes with moderate-severe ABP (n = 18), inferior average obtained using SLP-ECC had significantly (P = .03) greater AUROC (0.91 +/- 0.07) compared with SLP-VCC (0.78 +/- 0.11). CONCLUSIONS: SLP-ECC significantly reduces the frequency and severity of ABP compared with SLP-VCC and improves the correlation between RNFL measures and visual function.

Adult↗

Assessment of retinal nerve fiber layer using optical coherence tomography and scanning laser polarimetry in progressive glaucomatous optic neuropathy.

PURPOSE: To describe a case of progressive glaucomatous optic neuropathy using scanning laser polarimetry with fixed (SLP-FCC) and variable corneal compensation (SLP-VCC) and optical coherence tomography (OCT). DESIGN: Observational case report. METHODS: A 21-year-old male with juvenile primary open-angle glaucoma developed progression because of noncompliance with therapy. The patient underwent dilated stereoscopic examination and photography of the optic disk, standard automated perimetry (SAP), OCT, and SLP imaging with FCC and VCC at the baseline examination and after four years of follow-up. RESULTS: Optic disk, retinal nerve fiber layer (RNFL) atrophy, and SAP progression was observed. Reduction in mean RNFL thickness (average, superior, inferior) was 18, 18, and 27 microns (OCT); 22, 40, and 17 microns (SLP-FCC); and 6, 12, and 12 microns (SLP-VCC), respectively. CONCLUSIONS: This case demonstrates that digital imaging of the peripapillary RNFL is capable of documentation and measurement of progressive glaucomatous RNFL atrophy.

Adult↗

Detection of psychophysical and structural injury in eyes with glaucomatous optic neuropathy and normal standard automated perimetry.

OBJECTIVE: To compare the prevalence of structural and psychophysical abnormalities in normal eyes and eyes with glaucomatous optic neuropathy (GON) and normal standard automated perimetry (SAP). METHODS: Complete examination, SAP, short-wavelength automated perimetry (SWAP), frequency doubling technology (FDT), scanning laser polarimetry (GDx-VCC), and optical coherence tomography (OCT) of the peripapillary retinal nerve fiber layer (RNFL), optic disc, and macula were performed. Glaucomatous optic neuropathy was defined as cup-disc asymmetry between fellow eyes of greater than 0.2, rim thinning, notching, excavation, or RNFL defect. All eyes had normal SAP. Abnormal measurements on OCT, GDx-VCC, SWAP, and FDT were defined as those outside 95% normal limits. Eyes were stratified into 3 groups based on the OCT-generated vertical cup-disc ratio: mild, moderate, and advanced cupping (cup-disc ratio of <0.4, 0.4-0.7, and >0.7, respectively). Receiver operating characteristic curves were developed to assess sensitivity and specificity of structural and functional assessments. RESULTS: Forty-seven eyes of 47 patients (25 with GON and 22 normal) were enrolled (mean +/- SD age, 58 +/- 16 years; range, 25-83 years). Compared with normal eyes, eyes with GON had significantly worse mean deviation and pattern standard deviation by means of SWAP and FDT (P = .02-.05); OCT-derived mean and superior and inferior RNFL thickness (P = .008, <.001, and .05, respectively); mean macular thickness (P = .01), rim volume, rim area, cup-disc ratio, and cup area (all P<.001); and GDx-VCC nerve fiber indicator and inferior average (P = .03). There was a significantly (P = .008, .002, .003, and .01, respectively) greater prevalence of abnormalities identified by SWAP, FDT, OCT and GDx-VCC in eyes with advanced cupping (43%, 43%, 57%, and 57%, respectively) compared with mild cupping (0%) and moderate cupping (9%, 5%, 19%, and 33%, respectively). CONCLUSIONS: Eyes with GON and normal results of SAP have significantly greater structural and psychophysical abnormalities than do normal eyes evaluated by means of OCT, GDx-VCC, SWAP, and FDT. Eyes with increased vertical cup-disc ratio are more likely to manifest such abnormalities on advanced diagnostic testing.

Adult↗

Quantitative assessment of atypical birefringence images using scanning laser polarimetry with variable corneal compensation.

PURPOSE: To define the clinical characteristics of atypical birefringence images and to describe a quantitative method for their identification. DESIGN: Prospective, comparative, clinical observational study. METHODS: Normal and glaucomatous eyes underwent complete examination, standard automated perimetry, scanning laser polarimetry with variable corneal compensation (GDx-VCC), and optical coherence tomography (OCT) of the macula, peripapillary retinal nerve fiber layer (RNFL), and optic disk. Eyes were classified into two groups: normal birefringence pattern (NBP) and atypical birefringence pattern (ABP). Clinical, functional, and structural characteristics were assessed separately. A multiple logistic regression model was used to predict eyes with ABP on the basis of a quantitative scan score generated by a support vector machine (SVM) with GDx-VCC. RESULTS: Sixty-five eyes of 65 patients were enrolled. ABP images were observed in 5 of 20 (25%) normal eyes and 23 of 45 (51%) glaucomatous eyes. Compared with eyes with NBP, glaucomatous eyes with ABP demonstrated significantly lower SVM scores (P < .0001, < 0.0001, 0.008, 0.03, and 0.03, respectively) and greater temporal, mean, inferior, and nasal RNFL thickness using GDx-VCC; and a weaker correlation with OCT generated RNFL thickness (R(2) = .75 vs .27). ABP images were significantly correlated with older age (R(2) = .16, P = .001). The SVM score was the only significant (P < .0001) predictor of ABP images and provided high discriminating power between eyes with NBP and ABP (area under the receiver operator characteristic curve = 0.98). CONCLUSIONS: ABP images exist in a subset of normal and glaucomatous eyes, are associated with older patient age, and produce an artifactual increase in RNFL thickness using GDx-VCC. The SVM score is highly predictive of ABP images.

Adult↗

The Low-pressure Glaucoma Treatment Study (LoGTS) study design and baseline characteristics of enrolled patients.

OBJECTIVE: The Low-Pressure Glaucoma Treatment Study (LoGTS) seeks to evaluate visual field stability in low-pressure glaucoma patients randomized to intraocular pressure reduction in both eyes with topical twice daily brimonidine tartrate 0.2% versus twice daily timolol maleate 0.5%. This article describes the LoGTS design and presents baseline characteristics of the subjects. DESIGN: Randomized, multicenter, double-masked clinical trial. PARTICIPANTS: Low-pressure glaucoma patients 30 years of age or older were identified. Exclusion criteria included an untreated pressure of more than 21 mmHg, advanced visual field loss, and contraindications to study medications. INTERVENTIONS: Randomization of both eyes to double-masked monotherapy with brimonidine or timolol. Follow-up visits included Humphrey 24-2 full-threshold perimetry, tonometry every 4 months, and annual optic disc photography. MAIN OUTCOME MEASURE: Progression of visual field loss. RESULTS: One hundred ninety patients were randomized between 1998 and 2000. Mean age (+/-standard deviation) was 64.9+/-10.7 years. Women comprised 59.5% of the patients. Fifty-three patients (27.9%) had unilateral field loss. The 137 patients with bilateral field loss were older than those with unilateral field loss: 65.7 versus 62.3 years of age (P<0.05). Mean untreated diurnal intraocular pressures were similar between the eyes of the bilateral patients (mean, 15.5 mmHg in both eyes) and unilateral patients (mean, 16.0 mmHg in field loss vs. 15.6 mmHg in fellow eyes). Visual field mean deviation for all eyes was -5.4+/-4.7 decibels. Central corneal thickness in 168 phakic patients was 543 +/- 35 microm (range, 435-655 microm); thickness was less than 500 microm in 15 eyes and was more than 600 microm in 11 eyes. Mean vertical cup-to-disc ratio for all eyes was 0.67+/-0.15. Unilateral field loss patients had a larger cup-to-disc ratio in the field loss eye (0.75+/-0.12) than the fellow eye with a normal field (0.60+/-0.17, P<0.0001). Disc hemorrhage was present at baseline in 29 patients (32 eyes). CONCLUSIONS: The LoGTS was successfully able to recruit and enroll patients with open-angle glaucoma and statistically normal intraocular pressure into a longitudinal, prospective clinical trial comparing 2 different glaucoma medications. Baseline characteristics of note were a preponderance of females, unilateral field loss in 27.9% of participants, and frequent optic disc hemorrhage. Central corneal thickness had a normal distribution and did not account for false low-pressure measurements in LoGTS patients.

Adult↗

Predicting subsequent visual field loss in glaucomatous subjects with disc hemorrhage using retinal nerve fiber layer polarimetry.

PURPOSE: To predict progression of visual field loss after an episode of disc hemorrhage in glaucoma patients on the basis of retinal nerve fiber layer (RNFL) GDx polarimetry measurements analyzed by wavelet-Fourier analysis (WFA). METHODS: Retrospective GDx data from 16 subjects (10 progressors and 6 non-progressors based on visual fields) obtained near the time of disc hemorrhage were analyzed to predict which patients would have visual field progression. Polarimetry scans throughout a follow-up period (31 months average) were also analyzed to compare field progression to RNFL thickness change after the hemorrhage. Mean RNFL thickness inferred from the polarimetry data at sixteen 22.5 degrees sectors at distances of 1.6, 1.7, and 1.8 disc diameters were used. Data were analyzed by applying to appropriate regions of disc hemorrhage patients a structural analysis (WFA) we had developed previously. A linear discriminant function (Fischer) was produced and a leave-one-out method using separate training and test data was used to assure validity of the results. RESULTS: Patients who subsequently progressed were successfully predicted with moderate success (sensitivity / specificity was 0.77 / 0.88 with ROC area = 0.858). A separate analysis comparing pre- and post-hemorrhage RNFL sector thickness revealed clear evidence of RNFL thinning at the inferior and superior sectors before progression of visual field. The thinning of RNFL thickness was not restricted to regions corresponding to the location of the hemorrhage. CONCLUSION: Wavelet-Fourier analysis can differentiate progressors from non-progressors with moderate accuracy. Comparison to a prior study of this same cohort emphasizes that relatively small regions must be considered (as opposed to larger quadrants) to see these significant changes in RNFL.

Aged↗

Macular symmetry testing for glaucoma detection.

PURPOSE: To evaluate structural asymmetry in the macula using optical coherence tomography (OCT) in glaucomatous eyes with visual field defects localized to one hemifield. METHODS: Complete examination, standard automated perimetry (SAP), and OCT imaging (512 A-scans) of the peripapillary retina and macula were performed. Exclusion criteria were visual acuity <20/40, diseases other than glaucoma, and SAP defects localized to both hemifields. Macular OCT images were obtained using four 5-mm radial scans centered on the foveola and passing obliquely through the macula (15 degrees superotemporally and inferotemporally). Macular measurements temporal to the fovea (T) were sub-divided into nasal (T1) and temporal (T2) segments. Macular symmetry testing (MST) was performed in T, T1, and T2 segments by comparing the mean macular thickness of the perimetrically abnormal and perimetrically normal hemi-zones (macular thickness in perimetrically normal hemi-zone/macular thickness in perimetrically abnormal hemi-zone x 100), and superior and inferior hemi-zones in normal subjects (macular thickness in superior hemi-zone/macular thickness in inferior hemi-zone x 100). MST measurements were considered to be abnormal if they exceeded the 95% limits of normal variability. RESULTS: Forty eyes of 40 patients (20 normal, 20 glaucoma) were enrolled (mean age 60 +/- 19 years, range 21-89). All eyes with glaucoma had associated hemifield defect (average MD = -7.23 +/- 4.8 dB, range -0.9 to -15.4). In glaucomatous eyes, mean retinal thickness in T, T1, and T2 within the perimetrically abnormal hemi-zone (222 +/- 14 microm, 224+/- 17 microm, 221 +/-13 microm, respectively) was significantly less (P = 0.002, 0.008, 0.001, respectively) than the corresponding segments in the perimetrically normal hemi-zone (235 +/- 17 microm, 237 +/- 18 microm, 233 +/- 17 microm, respectively). Normal eyes showed no difference (P = 0.17, 0.20, 0.35) in T, T1, and T2 measurements within the superior hemi-zone (254 +/- 11, 249 +/- 14, 258 +/- 14) and inferior hemi-zone (252 +/- 11, 250 +/- 13, 255 +/- 13), respectively. MST values in glaucomatous eyes were outside 95% limits of normal variability in 17/20 (85%) T segments, 16 /20 (80%) T1 segments, and 16/20 (80%) T2 segments. CONCLUSION: Localized macular thickness changes exist in glaucomatous eyes with regional visual field loss. The MST may represent a novel strategy for glaucoma diagnosis.

Adult↗

Quantitative assessment of structural damage in eyes with localized visual field abnormalities.

PURPOSE: To evaluate the pattern of structural damage in the macula and peripapillary retinal nerve fiber layer (RNFL) using optical coherence tomography (OCT) and scanning laser polarimetry (SLP-VCC) in glaucomatous eyes with localized visual field defects. DESIGN: Prospective, cross-sectional analysis. METHODS: Complete examination, automated achromatic perimetry (AAP), Stratus OCT imaging (512 A-scans) of the peripapillary retina and macula, and SLP-VCC imaging of the peripapillary RNFL were performed. Thickness values in the retinal segments associated with the visual field defect (glaucomatous segments) were compared with corresponding segments across the horizontal raphe (nonglaucomatous segments) and age-matched normal controls. RESULTS: Forty eyes of 40 patients (20 normal, 20 glaucomatous) were enrolled (mean age, 71 +/- 10 years; range, 50 to 89). Mean RNFL thickness using SLP-VCC and OCT in the nonglaucomatous segments of glaucomatous eyes (54.0 +/- 9.7 microm, 64.7 +/- 19.0 microm) were significantly (P =.009, <0.0001) reduced compared with the thickness measurements in the corresponding segments of age-matched normal subjects (62.5 +/- 9.2 microm, 105.6 +/- 19.0 microm) respectively. No significant (P =.4) differences in the macular thickness measurements were observed between nonglaucomatous (239.0 +/- 19.4 microm) and normal segments (243.5 +/- 15.0 microm). Compared with age-matched controls, RNFL thickness in the nonglaucomatous segment was abnormal in 15 of 20 patients (75%) with SLP-VCC and in 18 of 20 patients (90%) with OCT. Macular thickness in the nonglaucomatous segment was abnormal in 11 of 20 patients (55%). CONCLUSIONS: Diffuse RNFL and retinal ganglion cell loss is present in eyes with localized visual field abnormalities. Detection of localized changes in macular thickness is limited by measurement overlap among normal and glaucomatous eyes.

Aged↗

Variable corneal compensation improves discrimination between normal and glaucomatous eyes with the scanning laser polarimeter.

PURPOSE: The presently available scanning laser polarimeter (SLP) has a fixed corneal compensator (FCC) that neutralizes corneal birefringence only in eyes with birefringence that matches the population mode. A prototype variable corneal compensator (VCC) provides neutralization of individual corneal birefringence based on individual macular retardation patterns. The aim of this study was to evaluate the relative ability of the SLP with the FCC and with the VCC to discriminate between normal and glaucomatous eyes. DESIGN: Prospective, nonrandomized, comparative case series. PARTICIPANTS: Algorithm-generating set consisting of 56 normal eyes and 55 glaucomatous eyes and an independent data set consisting of 83 normal eyes and 56 glaucomatous eyes. TESTING: Sixteen retardation measurements were obtained with the SLP with the FCC and the VCC from all subjects. MAIN OUTCOME MEASURES: Dependency of parameters on age, gender, ethnic origin, and eye side was sought. Logistic regression was used to evaluate how well the various parameters could detect glaucoma. Discriminant functions were generated, and the area under the receiver operating characteristic (ROC) curve was determined. RESULTS: Discrimination between normal and glaucomatous eyes on the basis of single parameters was significantly better with the VCC than with the FCC for 6 retardation parameters: nasal average (P = 0.0003), superior maximum (P = 0.0003), ellipse average (P = 0.002), average thickness (P = 0.003), superior average (P = 0.010), and inferior average (P = 0.010). Discriminant analysis identified the optimal combination of parameters for the FCC and for the VCC. When the discriminant functions were applied to the independent data set, areas under the ROC curve were 0.84 for the FCC and 0.90 for the VCC (P<0.021). When the discriminant functions were applied to a subset of patients with early visual field loss, areas under the ROC curve were 0.82 for the FCC and 0.90 for the VCC (P<0.016). CONCLUSION: Individual correction for corneal birefringence with the VCC significantly improved the ability of the SLP to distinguish between normal and glaucomatous eyes and enabled detection of patients with early glaucoma.

Adult↗

Relationship between visual field sensitivity and retinal nerve fiber layer thickness as measured by scanning laser polarimetry.

PURPOSE: To evaluate the strength and pattern of the relationship between visual field (VF) sensitivity and retinal nerve fiber layer (RNFL) thickness measurements by scanning laser polarimetry (SLP). METHODS: Fifty-four eyes of 54 normal subjects (age, 42 +/- 15 years; VF mean deviation [MD], -0.69 +/- 1.01 dB) and 51 eyes of 51 glaucoma patients (age, 66 +/- 14 years; VF MD, -6.92 +/- 5.43 dB) were imaged with an SLP using fixed corneal compensation (FCC) and variable corneal compensation (VCC). VF sensitivity was recorded in the dB and the 1/L scales. Linear and logarithmic relationships were sought globally and in six VF sectors. Relationships of VF and RNFL thickness with age were sought in normal subjects. RESULTS: Both VF sensitivity and RNFL thickness declined with age (as determined by the regression slope): -0.13% (P = 0.0005) and -0.64% (P = 0.0001) per year for dB and 1/L VF sensitivity, respectively, and -0.25% (P = 0.003) per year for VCC RNFL thickness. FCC RNFL thickness was not statistically significantly related to age. The relationship of VF sensitivity to VCC global (R(2) = 0.49) and sectoral (R(2) = 0.00-0.47) RNFL thickness was greater than for FCC global (R(2) = 0.12) and sectoral (R(2) = 0.00-0.21) RNFL thickness. Relationships were curvilinear with the dB scale, with logarithmic regression of dB VF sensitivity against RNFL thickness being significantly better than linear regression. Logarithmic regression of 1/L VF sensitivity against RNFL thickness was no better than linear regression for all sectors. There was no relationship between VF sensitivity and RNFL thickness in the temporal peripapillary RNFL sector. CONCLUSIONS: The strength of the structure/function relationships compare well with previous reports in the literature. The relationships were curvilinear with the dB scale and linear with the 1/L scale, and were much stronger with VCC than with FCC RNFL thickness measurements.

Adult↗

Variation of peripapillary retinal nerve fiber layer birefringence in normal human subjects.

PURPOSE: The retinal nerve fiber layer (RNFL) exhibits linear birefringence due to the oriented cylindrical structure of ganglion cell axons. The birefringence (Deltan) depends on the density and composition of axonal organelles. The purpose of this study was to evaluate the distribution of birefringence around the optic nerve head (ONH) in normal subjects. METHODS: Birefringence was calculated along circular scan paths around the ONH as Deltan = R/T, where R is RNFL retardance measured by scanning laser polarimetry (SLP) and T is RNFL thickness measured by optical coherence tomography (OCT). OCT scans on a 3.4 mm diameter circle were obtained from 26 normal subjects aged 18 to 53 years. Scans on circles with various diameters were obtained from 17 of these subjects. RESULTS: The average reproducibility of Deltan measured on three separate days in four subjects was +/- 0.05 nm/microm. In most subjects Deltan varied significantly along a circular path around the ONH, with maxima in superior and inferior bundles, minima temporally and nasally, and a mean of 0.32 +/- 0.03 nm/microm. Deltan profiles on circles of different diameter were similar, suggesting that Deltan did not vary along nerve fiber bundles. CONCLUSIONS: RNFL birefringence varies with position around the ONH. This variation may result from known structural differences among nerve fiber bundles that serve different retinal regions. Constant Deltan along bundles is consistent with this hypothesis. Measurements of RNFL birefringence may provide a means to detect early subcellular changes in glaucoma.

Adult↗

Macular thickness changes in glaucomatous optic neuropathy detected using optical coherence tomography.

OBJECTIVE: To correlate macular thickness and retinal nerve fiber layer (RNFL) thickness in normal and glaucomatous eyes using optical coherence tomography. METHODS: Complete examination, automated achromatic perimetry, and optical coherence tomography of the peripapillary RNFL and macula were performed. Exclusion criteria were visual acuity of less than 20/40, diseases other than glaucoma, and unreliable automated achromatic perimetry. Macular thickness measurements were generated using 6 radial optical coherence tomographic scans (5.9 mm) centered on the fovea, and mean and quadrantic macular thickness values were calculated. RESULTS: Fifty-nine eyes of 59 patients (29 normal and 30 glaucomatous) were enrolled (mean +/- SD age, 56.7 +/- 20.3 years; range, 20-91 years). All eyes with glaucoma had associated visual field loss (mean +/- SD mean defect, -8.4 +/- 5.8 dB). Mean macular thickness was significantly associated with visual field mean defect (R2 = 0.47; P<.001), pattern standard deviation (R2 = 0.32; P<.001), and mean RNFL thickness (R2 = 0.38; P<.001). In glaucomatous eyes with visual field loss localized to 1 hemifield (n = 11), mean +/- SD macular thickness in the quadrant associated with the field defect (277 +/- 28 micro m) was significantly less (P =.005) than in the unaffected quadrant (286 +/- 27 micro m). Mean RNFL thickness in the affected quadrant (89 +/- 53 micro m) was significantly thinner (P =.009) than in the unaffected quadrant (121 +/- 39 micro m). MAIN OUTCOME MEASURES: Mean total and quadrantic macular and RNFL thickness measurements. CONCLUSIONS: Macular thickness changes are well correlated with changes in visual function and RNFL structure in glaucoma and may be a surrogate indicator of retinal ganglion cell loss.

Adult↗

Scanning laser polarimetry and detection of progression after optic disc hemorrhage in patients with glaucoma.

OBJECTIVE: To examine retinal nerve fiber layer changes with scanning laser polarimetry (SLP) in the eyes of patients with glaucoma and optic disc hemorrhage. METHODS: Automated perimetry and SLP were performed in 17 eyes of 17 patients identified prospectively with optic disc hemorrhage. Criteria for visual field progression were based on decreased sensitivity seen at 3 adjacent points on the total deviation plot. Progression on SLP images was defined as a 15% or more decrease in the average thickness of the affected quadrant (superior or inferior), a 25% or more reduction in the affected quadrant ratio, an increase in the nerve fiber analyzer number of 10 or more (GDx Nerve Fiber Analyzer; Laser Diagnostic Technologies), or any change on Serial Analysis of the SLP images. MAIN OUTCOME MEASURES: Visual field progression and SLP image progression. RESULTS: The mean follow-up was 31 months (minimum, 12 months). Of the 17 eyes, 10 (59%) had visual field progression. No significant change was seen on SLP images for either the total group or the group with visual field progression. Five eyes (29%) showed progression on SLP images, 3 of which also showed visual field progression. Ten eyes showed progression on SLP images that was not confirmed on subsequent imaging. CONCLUSIONS: In eyes with visual field progression after optic disc hemorrhage, a significant change in the SLP image was not seen. Fluctuation of SLP results in patients with glaucoma necessitates confirmation of progression seen on SLP images.

Aged↗