Right atrial myxomas and hairy cell leukaemia: coincidence or causal relationship?
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to David R Ramsdale.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Both heavily calcified and ostial lesions are difficult to deal with by percutaneous transluminal coronary angioplasty (PTCA) alone. Acute results are often sub-optimal, complications are more frequent, and long-term results are disappointing. Optimal stent deployment may not be possible unless satisfactory lesion dilatation is achieved and the lesion made more compliant. The use of rotational atherectomy and cutting balloon angioplasty to a calcified ostial lesion in the left circumflex coronary artery prior to stent implantation is reported.
Aortic dissection is an acute medical emergency with a high mortality. Crucial to improving survival is early recognition and appropriate treatment. This review describes the presenting clinical features and imaging techniques used in the diagnosis of aortic dissection and outlines the treatment modalities.
Explore the source record for details and available documents.
BACKGROUND AND OBJECTIVE: Complex percutaneous coronary intervention (PCI) often requires introduction of numerous devices into and out of the arterial circulation and this may result in an increased risk of bacteraemia or even septicaemia. This study was undertaken to detect the frequency of bacteraemia that may be associated with such procedures. METHODS: 147 patients undergoing complex PCI had blood culture tests immediately after and 12 hours after the procedure. RESULTS: Of 147 patients, 26 (17.7%) had detectable bacteraemia immediately after PCI. Coagulase-negative staphylococcus was isolated most commonly. An additional 12% of patients yielded positive blood cultures in the next 12 hours with femoral sheaths still in-situ. There were no associated clinical sequelae. CONCLUSIONS: Uncomplicated bacteraemia is not uncommon as a result of complex PCI procedures. Although there are usually no clinical sequelae, these findings are important for those patients who are considered to be at moderate or high risk of infective endocarditis who require an invasive procedure such as PCI. This paper emphasizes the need for maximum sterility during PCI procedures if infective complications and stent infection are to be avoided.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
We present a case of a left internal mammary artery (LIMA) originating from the third part of the subclavian artery. Awareness of this possibility is particularly important when considering reintervention after coronary artery bypass surgery and the LIMA appears to be missing rather than obviously occluded.
BACKGROUND: Aim of this trial was to compare rotational atherectomy followed by balloon angioplasty (rotablation [ROTA] group) with balloon angioplasty (percutaneous transluminal coronary angioplasty [PTCA] group) alone in patients with diffuse in-stent restenosis. METHODS AND RESULTS: The ARTIST study is a multicenter, randomized, prospective European trial with 298 patients with in-stent restenosis>70% (mean lesion length, 14 +/- 8 mm) in stents, implanted in coronary arteries for >/= 3 months. In the PTCA group, angioplasty was performed at the discretion of the local investigator, and rotablation was performed by using a stepped-burr approach followed by adjunctive PTCA with low (</= 6 atm) inflation pressure. Intravascular ultrasound during the intervention and at follow-up was used in a substudy in 86 patients (45 PTCA, 41 ROTA). Angiography demonstrated no difference regarding the short-term outcome, with equivalent procedural success rates defined as remaining stenosis <30% (89% PTCA, 88% ROTA). However, the results showed that, in the long term, PTCA was a significantly better strategy than ROTA. Mean net gain in minimal lumen diameter was 0.67 mm and 0.45 mm for PTCA and ROTA, respectively (P=0.0019). Mean gain in diameter stenosis was 25% and 17% (P=0.002), resulting in restenosis (>/= 50%) rates of 51% (PTCA) and 65% (ROTA) (P=0.039). By intravascular ultrasound, the major difference was the missing stent over-expansion during PTCA after ROTA. Six-month event-free survival was significantly higher after PTCA (91.3%) compared with ROTA (79.6%, P=0.0052). CONCLUSIONS: In terms of the primary objective of the study, PTCA produced a significantly better long-term outcome than ROTA followed by adjunctive low-pressure PTCA.
Acute myocardial infarction is a well-recognized complication of the Hughes syndrome but its optimal treatment is uncertain. We report a case of a 42-year-old man with a history of previous arterial and venous thrombosis who presented with an acute myocardial infarction that was successfully treated by primary angioplasty and stenting.
A 58-year-old man re-presented with symptoms of angina 3 months after percutaneous transluminal coronary angioplasty (PTCA) and stenting to his proximal left anterior descending artery (LAD). Angiography revealed ostial in-stent restenosis of the LAD, which was treated with rotational atherectomy and a cutting balloon PTCA. Combining two useful technologies for treating in-stent restenosis may prove to yield better results than using either technique alone. Long-term benefit will need to be assessed by randomized studies.
The X-SIZER thromboatherectomy catheter system (EndiCOR Medical, Inc.) was initially developed for the treatment of thrombus in acute coronary syndromes. We present the case of a 64-year-old man with thrombotic occlusion of the left circumflex coronary artery. Antegrade flow was restored by aspiration of platelet thrombus at the point of occlusion, although the catheter was unable to cross the underlying stenosis. Its limited ability to cross severe stenoses or reduce lesion severity suggests that the X-SIZER should not be regarded as an atherectomy device. However, this case report suggests that the X-SIZER device has potential as an adjunct to PTCA and stenting in reducing the risk associated with thrombotic occlusion.
BACKGROUND: Coronary artery stenting is particularly useful during percutaneous coronary intervention for long lesions previously associated with a low procedural success rate and a high complication rate of dissection and occlusion. Current treatment options include implantation of a single long stent, multiple contiguous stents, or 'spot' stenting. However, multiple stent implantation may result in sections of overlapping stent or gaps of unstented segments and is an independent predictor of restenosis. The early and intermediate clinical outcome of single and multiple long stent (>/= 30 mm) implantation is not established. METHODS AND RESULTS: The authors retrospectively identified 123 consecutive patients who had undergone stenting using one or more long coronary stents. Baseline clinical data, procedural outcomes and completed clinical follow-up to 52 weeks were obtained by case-note review. The majority (69%) required intervention for stable coronary disease. Seventy-seven per cent of lesions were either type B2 or C and only 2% were in saphenous vein grafts. The procedural success rate was 94%. A total of 15 major events occurred in 13 patients (11%). Ten acute events occurred and five events were during the follow-up period from 30 days to 52 weeks. Two patients died, one from uncontrolled bleeding secondary to the use of antithrombotic agents and one at four weeks due to sudden death. One patient had a postprocedural infarct. Two patients required in-hospital repeat revascularization for acute vessel closure and eight required revascularization during follow-up (three cases of occlusion/thrombosis and five cases of restenosis). CONCLUSIONS: The use of long coronary stents (>/= 30 mm) for the treatment of long diffuse native vessel disease, saphenous vein graft disease and long coronary dissections is associated with a reasonable procedural success rate and acceptable early and intermediate-term clinical outcomes.