Potential interference by hydroxocobalamin on cooximetry hemoglobin measurements during cyanide and smoke inhalation treatments.

STUDY OBJECTIVE: Concentrated aqueous solutions of hydroxocobalamin (OHCob) are administered intravenously for cyanide poisoning victims, many of whom also have concurrent smoke inhalation. Because of its intense light absorbance in visible wavelengths (absorption peak at 532 nm), we investigate potential interference effects of OHCob on total hemoglobin concentration (tHb), carboxyhemoglobin (COHb), methemoglobin (MetHb), and oxyhemoglobin (Hb-O2) cooximetry measurement values in blood. METHODS: In vivo cooximetry measurements were conducted with 3 specific pathogen-free white New Zealand rabbits (3.80+/-0.21 kg) during the intravenous infusion of OHCob (625 mg during a 100-minute period). Resultant changes in tHb, Hb-O2, COHb, and MetHb values were measured and correlated with respect to estimated in vivo OHCob concentrations. In vitro measurements were conducted with rabbit blood to confirm in vivo measurements. RESULTS: The introduction of OHCob clearly interfered with the cooximetry measurements of each of the hemoglobin component fractions in whole blood and resulted in altered measurement values from the baseline values. The presence of OHCob in blood interferes with cooximetry measurements of COHb, MetHb, and Hb-O2. The increase in measured COHb fraction with increasing concentrations of OHCob was most notable. CONCLUSION: The presence of OHCob in blood interferes with cooximetry measurements of COHb, MetHb, and Hb-O2. These effects need to be considered during OHCob treatment of cyanide poisoning, particularly in smoke inhalation victims with potential for concurrent carbon monoxide exposure, because it may lead to potentially erroneous reported COHb levels.

Animals↗

Feasibility of three-dimensional optical coherence tomography and optical Doppler tomography of malignancy in hamster cheek pouches.

OBJECTIVE: Hamster cheek pouches (HCP) with various degrees of 9,10-dimethyl-1,2-benzanthracene (DMBA)-induced dysplasia and malignancies were imaged with OCT/ODT in vivo and in vitro to assess the potential for three-dimensional high-resolution optical localization of airway malignancy. BACKGROUND DATA: Optical coherence tomography (OCT)/optical doppler tomography (ODT) provide potential capability for real-time in vivo high-resolution (2-20 microm) cross-sectional imaging of tissues and spatially resolved blood flow in microvasculature for pathology diagnostics. METHODS: DMBA was applied to the right side of the cheek pouch (HCP), and mineral oil (control) to the left side three times weekly for 10-18 weeks in Syrian Golden Hamsters using a standard protocol for malignancy induction. HCP were imaged in vivo with OCT/ODT as well as in vitro post-excision, using a prototype 1310-nm broadband superluminescent diode-based OCT/ODT device constructed in our laboratory. Three-dimensional images were constructed, and compared to standard and three-dimensional histology hematoxylin and eosin staining. RESULTS AND CONCLUSION: OCT imaging offered exceptional resolution of the HCP to depths of 1-2 mm and confirmed ability to detect dysplasia and malignancy. Three-dimensional OCT images were readily constructed, allowing visualization of extent and localization of tumor margins. ODT demonstrated increased vascularity in the area of neoplasia. OCT/ODT is a promising new technology for oral airway diagnostics.

Animals↗

Fiber-optic-bundle-based optical coherence tomography.

A fiber-optic-bundle-based optical coherence tomography (OCT) probe method is presented. The experimental results demonstrate this multimode optical fiber-bundle-based OCT system can achieve a lateral resolution of 12 microm and an axial resolution of 10 microm with a superluminescent diode source. This novel OCT imaging approach eliminates any moving parts in the probe and has a primary advantage for use in extremely compact and safe OCT endoscopes for imaging internal organs and great potential to be combined with confocal endoscopic microscopy.

Animals↗