Continuous intensity map optimization (CIMO): a novel approach to leaf sequencing in step and shoot IMRT.

A new leaf-sequencing approach has been developed that is designed to reduce the number of required beam segments for step-and-shoot intensity modulated radiation therapy (IMRT). This approach to leaf sequencing is called continuous-intensity-map-optimization (CIMO). Using a simulated annealing algorithm, CIMO seeks to minimize differences between the optimized and sequenced intensity maps. Two distinguishing features of the CIMO algorithm are (1) CIMO does not require that each optimized intensity map be clustered into discrete levels and (2) CIMO is not rule-based but rather simultaneously optimizes both the aperture shapes and weights. To test the CIMO algorithm, ten IMRT patient cases were selected (four head-and-neck, two pancreas, two prostate, one brain, and one pelvis). For each case, the optimized intensity maps were extracted from the Pinnacle3 treatment planning system. The CIMO algorithm was applied, and the optimized aperture shapes and weights were loaded back into Pinnacle. A final dose calculation was performed using Pinnacle's convolution/superposition based dose calculation. On average, the CIMO algorithm provided a 54% reduction in the number of beam segments as compared with Pinnacle's leaf sequencer. The plans sequenced using the CIMO algorithm also provided improved target dose uniformity and a reduced discrepancy between the optimized and sequenced intensity maps. For ten clinical intensity maps, comparisons were performed between the CIMO algorithm and the power-of-two reduction algorithm of Xia and Verhey [Med. Phys. 25(8), 1424-1434 (1998)]. When the constraints of a Varian Millennium multileaf collimator were applied, the CIMO algorithm resulted in a 26% reduction in the number of segments. For an Elekta multileaf collimator, the CIMO algorithm resulted in a 67% reduction in the number of segments. An average leaf sequencing time of less than one minute per beam was observed.

Algorithms↗

Clinical implementation of an automated planning system for gamma knife radiosurgery.

PURPOSE: To evaluate an automated treatment planning system for gamma knife radiosurgery. This planning system was developed in our clinic and is now in routine clinical use. The system simultaneously optimizes the shot sizes, locations, and weights. It also guides the user in selecting the total number of radiation shots. METHODS AND MATERIALS: We assessed the clinical significance of the automated system by comparing an optimized plan with a manual plan for 10 consecutive patients treated at our gamma knife facility. Each treatment plan was analyzed using dose-volume histograms in conjunction with the conformity index, the minimum target dose, and the integral normal tissue dose. RESULTS: On average, the treatment plan produced by the inverse planning tool provided an improved conformity index, a higher minimum target dose, and a reduced volume of the 30% isodose line as compared to the corresponding plan developed by an experienced physician. An optimized treatment plan can typically be produced in 10 min or less. CONCLUSIONS: The automated planning system consistently provides a high-quality treatment plan while reducing the time required for gamma knife treatment planning.

Humans↗

Convolution/superposition using the Monte Carlo method.

The convolution/superposition calculations for radiotherapy dose distributions are traditionally performed by convolving polyenergetic energy deposition kernels with TERMA (total energy released per unit mass) precomputed in each voxel of the irradiated phantom. We propose an alternative method in which the TERMA calculation is replaced by random sampling of photon energy, direction and interaction point. Then, a direction is randomly sampled from the angular distribution of the monoenergetic kernel corresponding to the photon energy. The kernel ray is propagated across the phantom, and energy is deposited in each voxel traversed. An important advantage of the explicit sampling of energy is that spectral changes with depth are automatically accounted for. No spectral or kernel hardening corrections are needed. Furthermore, the continuous sampling of photon direction allows us to model sharp changes in fluence, such as those due to collimator tongue-and-groove. The use of explicit photon direction also facilitates modelling of situations where a given voxel is traversed by photons from many directions. Extra-focal radiation, for instance, can therefore be modelled accurately. Our method also allows efficient calculation of a multi-segment/multi-beam IMRT plan by sampling of beam angles and field segments according to their relative weights. For instance, an IMRT plan consisting of seven 14 x 12 cm2 beams with a total of 300 field segments can be computed in 15 min on a single CPU, with 2% statistical fluctuations at the isocentre of the patient's CT phantom divided into 4 x 4 x 4 mm3 voxels. The calculation contains all aperture-specific effects, such as tongue and groove, leaf curvature and head scatter. This contrasts with deterministic methods in which each segment is given equal importance, and the time taken scales with the number of segments. Thus, the Monte Carlo superposition provides a simple, accurate and efficient method for complex radiotherapy dose calculations.

Algorithms↗