Search PubMed⌕ Search

Biomedical subjects

David M Haaland

Publications and source records attributed to David M Haaland.

7 recordsLinked to original sources

Hyperspectral confocal microscope.

We have developed a new, high performance, hyperspectral microscope for biological and other applications. For each voxel within a three-dimensional specimen, the microscope simultaneously records the emission spectrum from 500 nm to 800 nm, with better than 3 nm spectral resolution. The microscope features a fully confocal design to ensure high spatial resolution and high quality optical sectioning. Optical throughput and detection efficiency are maximized through the use of a custom prism spectrometer and a backside thinned electron multiplying charge coupled device (EMCCD) array. A custom readout mode and synchronization scheme enable 512-point spectra to be recorded at a rate of 8300 spectra per second. In addition, the EMCCD readout mode eliminates curvature and keystone artifacts that often plague spectral imaging systems. The architecture of the new microscope is described in detail, and hyperspectral images from several specimens are presented.

Equipment Design↗

Hyperspectral microarray scanning: impact on the accuracy and reliability of gene expression data.

BACKGROUND: Commercial microarray scanners and software cannot distinguish between spectrally overlapping emission sources, and hence cannot accurately identify or correct for emissions not originating from the labeled cDNA. We employed our hyperspectral microarray scanner coupled with multivariate data analysis algorithms that independently identify and quantitate emissions from all sources to investigate three artifacts that reduce the accuracy and reliability of microarray data: skew toward the green channel, dye separation, and variable background emissions. RESULTS: Here we demonstrate that several common microarray artifacts resulted from the presence of emission sources other than the labeled cDNA that can dramatically alter the accuracy and reliability of the array data. The microarrays utilized in this study were representative of a wide cross-section of the microarrays currently employed in genomic research. These findings reinforce the need for careful attention to detail to recognize and subsequently eliminate or quantify the presence of extraneous emissions in microarray images. CONCLUSION: Hyperspectral scanning together with multivariate analysis offers a unique and detailed understanding of the sources of microarray emissions after hybridization. This opportunity to simultaneously identify and quantitate contaminant and background emissions in microarrays markedly improves the reliability and accuracy of the data and permits a level of quality control of microarray emissions previously unachievable. Using these tools, we can not only quantify the extent and contribution of extraneous emission sources to the signal, but also determine the consequences of failing to account for them and gain the insight necessary to adjust preparation protocols to prevent such problems from occurring.

Algorithms↗

Multivariate analysis of infrared spectra for monitoring and understanding the kinetics and mechanisms of adsorption processes.

Water adsorption onto thin zeolite 3A wafers has been investigated as a function of time, water vapor concentration, and zeolite sample mass using mid-infrared spectroscopy coupled with multivariate data analysis. Principal component analysis (PCA) of the spectral region of the water combination band was used for quantitative characterization of water adsorption onto the zeolite. The kinetics of the adsorption of water are found to be very reproducible and nearly linear with time. The kinetics of water adsorption based on data from different masses of zeolite are consistent with a diffusion/immobilization model for which the interparticle diffusion rate is comparable to the rate of adsorption. The infrared zeolite bands (1340-1550 cm(-1)) change during the adsorption process and yield more detail about the adsorption sites of the material. PCA applied to the zeolite bands was not directly interpretable. However, multivariate curve resolution applied to the spectral region containing the zeolite bands readily demonstrates that zeolite 3A has three water adsorption sites or environments that are sequentially occupied. Potential explanations for the observations of the multivariate curve resolution (MCR) analysis of these infrared (IR) kinetic adsorption experiments are presented. The explanation most consistent with our data suggests that water adsorbs sequentially on the zeolite to form single, double, and triple water adsorption on single zeolite adsorption sites. The combination of infrared spectroscopy and multivariate analysis is therefore demonstrated to be a powerful method to study detailed adsorption kinetics and mechanisms of the adsorption of molecules onto surfaces.

Adsorption↗

Design, construction, characterization, and application of a hyperspectral microarray scanner.

We describe the design, construction, and operation of a hyperspectral microarray scanner for functional genomic research. The hyperspectral instrument operates with spatial resolutions ranging from 3 to 30 microm and records the emission spectrum between 490 and 900 nm with a spectral resolution of 3 nm for each pixel of the microarray. This spectral information, when coupled with multivariate data analysis techniques, allows for identification and elimination of unwanted artifacts and greatly improves the accuracy of microarray experiments. Microarray results presented in this study clearly demonstrate the separation of fluorescent label emission from the spectrally overlapping emission due to the underlying glass substrate. We also demonstrate separation of the emission due to green fluorescent protein expressed by yeast cells from the spectrally overlapping autofluorescence of the yeast cells and the growth media.

Equipment Design↗

Effects of nonlinearities and uncorrelated or correlated errors in realistic simulated data on the prediction abilities of augmented classical least squares and partial least squares.

Comparisons of prediction models from the new augmented classical least squares (ACLS) and partial least squares (PLS) multivariate spectral analysis methods were conducted using simulated data containing deviations from the idealized model. The simulated data were based on pure spectral components derived from real near-infrared spectra of multicomponent dilute aqueous solutions. Simulated uncorrelated concentration errors, uncorrelated and correlated spectral noise, and nonlinear spectral responses were included to evaluate the methods on situations representative of experimental data. The statistical significance of differences in prediction ability was evaluated using the Wilcoxon signed rank test. The prediction differences were found to be dependent on the type of noise added, the numbers of calibration samples, and the component being predicted. For analyses applied to simulated spectra with noise-free nonlinear response, PLS was shown to be statistically superior to ACLS for most of the cases. With added uncorrelated spectral noise, both methods performed comparably. Using 50 calibration samples with simulated correlated spectral noise, PLS showed an advantage in 3 out of 9 cases, but the advantage dropped to 1 out of 9 cases with 25 calibration samples. For cases with different noise distributions between calibration and validation, ACLS predictions were statistically better than PLS for two of the four components. Also, when experimentally derived correlated spectral error was added, ACLS gave better predictions that were statistically significant in 15 out of 24 cases simulated. On data sets with nonuniform noise, neither method was statistically better, although ACLS usually had smaller standard errors of prediction (SEPs). The varying results emphasize the need to use realistic simulations when making comparisons between various multivariate calibration methods. Even when the differences between the standard error of predictions were statistically significant, in most cases the differences in SEP were small. This study demonstrated that unlike CLS, ACLS is competitive with PLS in modeling nonlinearities in spectra without knowledge of all the component concentrations. This competitiveness is important when maintaining and transferring models for system drift, spectrometer differences, and unmodeled components, since ACLS models can be rapidly updated during prediction when used in conjunction with the prediction augmented classical least squares (PACLS) method, while PLS requires full recalibration.

Algorithms↗

Identification and removal of contaminating fluorescence from commercial and in-house printed DNA microarrays.

Microarray analysis is a critically important technology for genome-enabled biology, therefore it is essential that the data obtained be reliable. Current software and normalization techniques for microarray analysis rely on the assumption that fluorescent background within spots is essentially the same throughout the glass slide and can be measured by fluorescence surrounding the spots. This assumption is not valid if background fluorescence is spot-localized. Inaccurate estimates of background fluorescence under the spot create a source of error, especially for low expressed genes. We have identified spot-localized, contaminating fluorescence in the Cy3 channel on several commercial and in-house printed microarray slides. We determined through mock hybridizations (without labeled target) that pre-hybridization scans could not be used to predict the contribution of this contaminating fluorescence after hybridization because the change in spot-to-spot fluorescence after hybridization was too variable. Two solutions to this problem were identified. First, allowing 4 h of exposure to air prior to printing on to Corning UltraGAPS slides significantly reduced contaminating fluorescence intensities to approximately the value of the surrounding glass. Alternatively, application of a novel, hyperspectral imaging scanner and multivariate curve resolution algorithms, allowed the spectral contributions of Cy3 signal, glass, and contaminating fluorescence to be distinguished and quantified after hybridization.

Artifacts↗

Carbon sequestration in Synechococcus Sp.: from molecular machines to hierarchical modeling.

The U.S. Department of Energy recently announced the first five grants for the Genomes to Life (GTL) Program. The goal of this program is to "achieve the most far-reaching of all biological goals: a fundamental, comprehensive, and systematic understanding of life." While more information about the program can be found at the GTL website (www.doegenomestolife.org), this paper provides an overview of one of the five GTL projects funded, "Carbon Sequestration in Synechococcus Sp.: From Molecular Machines to Hierarchical Modeling." This project is a combined experimental and computational effort emphasizing developing, prototyping, and applying new computational tools and methods to elucidate the biochemical mechanisms of the carbon sequestration of Synechococcus Sp., an abundant marine cyanobacteria known to play an important role in the global carbon cycle. Understanding, predicting, and perhaps manipulating carbon fixation in the oceans has long been a major focus of biological oceanography and has more recently been of interest to a broader audience of scientists and policy makers. It is clear that the oceanic sinks and sources of CO(2) are important terms in the global environmental response to anthropogenic atmospheric inputs of CO(2) and that oceanic microorganisms play a key role in this response. However, the relationship between this global phenomenon and the biochemical mechanisms of carbon fixation in these microorganisms is poorly understood. The project includes five subprojects: an experimental investigation, three computational biology efforts, and a fifth which deals with addressing computational infrastructure challenges of relevance to this project and the Genomes to Life program as a whole. Our experimental effort is designed to provide biology and data to drive the computational efforts and includes significant investment in developing new experimental methods for uncovering protein partners, characterizing protein complexes, identifying new binding domains. We will also develop and apply new data measurement and statistical methods for analyzing microarray experiments. Our computational efforts include coupling molecular simulation methods with knowledge discovery from diverse biological data sets for high-throughput discovery and characterization of protein-protein complexes and developing a set of novel capabilities for inference of regulatory pathways in microbial genomes across multiple sources of information through the integration of computational and experimental technologies. These capabilities will be applied to Synechococcus regulatory pathways to characterize their interaction map and identify component proteins in these pathways. We will also investigate methods for combining experimental and computational results with visualization and natural language tools to accelerate discovery of regulatory pathways. Furthermore, given that the ultimate goal of this effort is to develop a systems-level of understanding of how the Synechococcus genome affects carbon fixation at the global scale, we will develop and apply a set of tools for capturing the carbon fixation behavior of complex of Synechococcus at different levels of resolution. Finally, because the explosion of data being produced by high-throughput experiments requires data analysis and models which are more computationally complex, more heterogeneous, and require coupling to ever increasing amounts of experimentally obtained data in varying formats, we have also established a companion computational infrastructure to support this effort as well as the Genomes to Life program as a whole.

Algorithms↗