Search PubMed⌕ Search

Biomedical subjects

David J Vining

Publications and source records attributed to David J Vining.

6 recordsLinked to original sources

Challenges and opportunities associated with the MD Anderson IMPACT2 randomized study in precision oncology.

We investigated the challenges of conducting IMPACT2, an ongoing randomized study that evaluates molecular testing and targeted therapy (ClinicalTrials.gov: NCT02152254). Patients with metastatic cancer underwent tumor profiling and were randomized between the two arms when eligibility criteria were met (Part A). In Part B, patients who declined randomization could choose the study arm. In Part A, 69 (21.8%) of 317 patients were randomized; 78.2% were not randomized because of non-targetable alterations (39.8%), unavailability of clinical trial (21.8%), other reasons (12.6%), or availability of US Food and Drug Administration (FDA)-approved drugs for the indication (4.1%). In Part B, 32 (20.4%) of 157 patients were offered randomization; 16 accepted and 16 selected their treatment arm; 79.0% were not randomized (patient's/physician's choice, 29.3%; treatment selection prior to genomic reports, 16.6%; worsening performance status/death, 12.7%; unavailability of clinical trials, 6.4%; other, 6.4%; non-targetable alterations, 5.7%; or availability of FDA-approved drugs for the indication, 1.9%). In conclusion, although randomized controlled trials have been considered the gold standard for drug development, the execution of randomized trials in precision oncology in the advanced metastatic setting is complicated. We encountered various challenges conducting the IMPACT2 study, a large precision oncology trial in patients with diverse solid tumor types. The adaptive design of IMPACT2 enables patient randomization despite the continual FDA approval of targeted therapies, the evolving tumor biomarker landscape, and the plethora of investigational drugs. Outcomes for randomized patients are awaited.

Journal Article↗

Segmentation in virtual colonoscopy using a geometric deformable model.

The Geometric Deformable Model is developed for accurate colon lumen segmentation as part of an automatic Virtual Colonoscopy system. The deformable model refines the lumen surface found by an automatic seed location and thresholding procedure. The challenges to applying the deformable model are described, showing the definition of the stopping function as the key to accurate segmentation. The limitations of current stopping criteria are examined and a new definition, tailored to the task of colon segmentation, is given. First, a multiscale edge operator is used to locate high confidence boundaries. These boundaries are then integrated into the stopping function using a distance transform. The hypothesis is that the new stopping function results in a more accurate representation of the lumen surface compared to previous monotonic functions of the gradient magnitude. This hypothesis is tested using observer ratings of colon surface fidelity at 100,000 randomly selected locations in each of four datasets. The results show that the surfaces determined by the modified deformable model better represent the lumen surface overall.

Algorithms↗

Computed tomographic colonography (virtual colonoscopy): a multicenter comparison with standard colonoscopy for detection of colorectal neoplasia.

CONTEXT: Conventional colonoscopy is the best available method for detection of colorectal cancer; however, it is invasive and not without risk. Computed tomographic colonography (CTC), also known as virtual colonoscopy, has been reported to be reasonably accurate in the diagnosis of colorectal neoplasia in studies performed at expert centers. OBJECTIVE: To assess the accuracy of CTC in a large number of participants across multiple centers. DESIGN, SETTING, AND PARTICIPANTS: A nonrandomized, evaluator-blinded, noninferiority study design of 615 participants aged 50 years or older who were referred for routine, clinically indicated colonoscopy in 9 major hospital centers between April 17, 2000, and October 3, 2001. The CTC was performed by using multislice scanners immediately before standard colonoscopy; findings at colonoscopy were reported before and after segmental unblinding to the CTC results. MAIN OUTCOME MEASURES: The sensitivity and specificity of CTC and conventional colonoscopy in detecting participants with lesions sized at least 6 mm. Secondary outcomes included detection of all lesions, detection of advanced lesions, possible technical confounders, participant preferences, and evidence for increasing accuracy with experience. RESULTS: A total of 827 lesions were detected in 308 of 600 participants who underwent both procedures; 104 participants had lesions sized at least 6 mm. The sensitivity of CTC for detecting participants with 1 or more lesions sized at least 6 mm was 39.0% (95% confidence interval [CI], 29.6%-48.4%) and for lesions sized at least 10 mm, it was 55.0% (95% CI, 39.9%-70.0%). These results were significantly lower than those for conventional colonoscopy, with sensitivities of 99.0% (95% CI, 97.1%->99.9%) and 100%, respectively. A total of 496 participants were without any lesion sized at least 6 mm. The specificity of CTC and conventional colonoscopy for detecting participants without any lesion sized at least 6 mm was 90.5% (95% CI, 87.9%-93.1%) and 100%, respectively, and without lesions sized at least 10 mm, 96.0% (95% CI, 94.3%-97.6%) and 100%, respectively. Computed tomographic colonography missed 2 of 8 cancers. The accuracy of CTC varied considerably between centers and did not improve as the study progressed. Participants expressed no clear preference for either technique. CONCLUSIONS: Computed tomographic colonography by these methods is not yet ready for widespread clinical application. Techniques and training need to be improved.

Colonography, Computed Tomographic↗

Virtual colonoscopy using oral contrast compared with colonoscopy for the detection of patients with colorectal polyps.

BACKGROUND & AIMS: Virtual colonoscopy using abdominal spiral computed tomography scanning allows total colonic evaluation with minimal invasiveness. Two-dimensional images and selective 3-dimensional images of the colon are used to detect colorectal lesions. This trial used conventional colonoscopy with segmental unblinding to determine the ability of virtual colonoscopy to identify patients with colorectal lesions who need conventional colonoscopy. METHODS: We studied 205 patients with virtual colonoscopy using oral iodinated contrast preceding conventional colonoscopy. Colonic lavage was achieved with an oral sodium phosphosoda preparation and colonic distention with a carbon dioxide electronic insufflator. RESULTS: The overall sensitivity and specificity of virtual colonoscopy in identifying patients with colorectal lesions was 61.8% and 70.7%, respectively. Virtual colonoscopy was more accurate in identifying patients with lesions >/=6 mm (sensitivity 84.4% and specificity 83.1%) and those with lesions >/=10 mm (sensitivity 90% and specificity 94.6%). The negative predictive value of virtual colonoscopy was 95% for a 6-mm cutoff size and 98.9% for a 10-mm cutoff. Using a 10-mm cutoff, virtual colonoscopy precludes the need for conventional colonoscopy in 86% of patients with a 1% false-negative rate (68% with a 3.4% false-negative rate when using a 6-mm cutoff). CONCLUSIONS: Virtual colonoscopy has a high sensitivity and specificity for detecting patients with significant colorectal lesions. Its high negative predictive value may help reduce the number of negative screening colonoscopies. Further studies are needed to determine what lesion cutoff size is clinically acceptable and the appropriate interval time for repeat virtual colonoscopy when it detects lesions below this cutoff size.

Administration, Oral↗

The virtual colonoscopy study: a large multicenter clinical trial designed to compare two diagnostic screening procedures.

This paper reviews the design of a large multicenter clinical trial currently being conducted to test the equivalence of two screening procedures for colorectal polyps. The primary outcome is the sensitivity and specificity of the new and standard procedures for detecting subjects with and without polyps of a size > or =6 mm, respectively. An important secondary outcome is the accuracy of these procedures in detecting individual polyps. A total of 619 participants underwent virtual colonoscopy, the new procedure, followed by conventional colonoscopy, the standard procedure. Strategies for the design and implementation of the study are shared as well as the challenges encountered.

Bias↗