Search PubMed⌕ Search

Biomedical subjects

David J Sahn

Publications and source records attributed to David J Sahn.

44 records · Page 3Linked to original sources

Direct quantification of transmitral flow volume with dynamic 3-dimensional digital color Doppler: a validation study in an animal model.

Accurately quantifying transmitral flow volume is clinically important not only as a measure of cardiac output, but also as a value from which to subtract aortic flow, for determining the severity of mitral regurgitation. However, controversy exists over the accuracy of pulsed Doppler for mitral flow quantification because of the complexity of mitral flow geometry and dynamic changes in flow profile and flow area. To explore the feasibility of directly quantifying transmitral flow volume with a newly developed dynamic 3-dimensional digital color Doppler technique, this in vivo experimental study was conducted to validate the method. Eight open chest sheep were imaged with a multiplane transesophageal (TEE) probe placed on the heart for digital 3-dimensional gated acquisition of mitral inflow over a 180-degree acquisition. The digital velocity data were contour detected for flow area after computing the velocity vectors and flow profile perpendicular to a spherical 3-dimensional surface across the mitral annulus. Flow areas and actual velocities were then integrated in time and space and the resulting flow volumes were compared with those obtained by a reference electromagnetic flowmeter on the aorta for 26 steady hemodynamic states. The flow volumes correlated closely to the electromagnetic references (y = 0.87x + 2.49, r = 0.92, SEE = 1.9 Ml per beat). Our study shows that transmitral flow volume can be accurately determined in vivo by this dynamic 3-dimensional digital color Doppler flow quantification method.

Animals↗

A validation study of aortic stroke volume using dynamic 4-dimensional color Doppler: an in vivo study.

OBJECTIVE: To explore the feasibility of directly quantifying transaortic stroke volume with a newly developed dynamic 3-dimensional (3D) color Doppler flow measurement technique, an in vivo experimental study was performed. BACKGROUND: Traditional methods for flow quantification require geometric assumptions about flow area and flow profiles. Accurate quantification of flow across the aortic valve is clinically important as a means of estimating cardiac output. METHODS: Eight open-chest sheep were scanned with apical epicardial placement of a 7 to 4 MHz multiplane transesophageal probe scanning parallel to aortic flow and running on an ATL HDI 5000 system. An electromagnetic flow meter implanted on the ascending aorta was used as reference. Thirty different hemodynamic conditions were studied after steady states were obtained in the animals by administration of blood, angiotensin, and sodium nitroprusside. Electrocardiogram-gated digital color 3D velocity data were acquired for each of the 30 steady states. The aortic stroke volumes were computed by temporal and spatial integration of flow areas and actual velocities across a projected surface perpendicular to the direction of flow, at a level just below the aortic valve. RESULTS: There was close correlation between the 3D color Doppler calculated aortic stroke volumes and the electromagnetic data (r = 0.91, y = 0.96x + 1.01, standard error of the estimate = 2.6 mL/beat). CONCLUSION: Our results showed that dynamic 3D color Doppler measurements obtained in an open-chest animals provide the basis for accurate, geometry-independent quantitative evaluation of the aortic flow. Therefore, 3D digital color Doppler flow computation could potentially represent an important method for noninvasively determining cardiac output in patients.

Animals↗

Quantification of instantaneous flow rate and dynamically changing effective orifice area using a geometry independent three-dimensional digital color Doppler method: An in vitro study mimicking mitral regurgitation.

OBJECTIVE: Our study was intended to test the accuracy of a 3-dimensional (3D) digital color Doppler flow convergence (FC) method for assessing the effective orifice area (EOA) in a new dynamic orifice model mimicking a variety of mitral regurgitation. BACKGROUND: FC surface area methods for detecting EOA have been reported to be useful for quantifying the severity of valvular regurgitation. With our new 3D digital direct FC method, all raw velocity data are available and variable Nyquist limits can be selected for computation of direct FC surface area for computing instantaneous flow rate and temporal change of EOA. METHODS: A 7.0-MHz multiplane transesophageal probe from an ultrasound system (ATL HDI 5000) was linked and controlled by a computer workstation to provide 3D images. Three differently shaped latex orifices (zigzag, arc, and straight slit, each with cutting-edge length of 1 cm) were used to mimic the dynamic orifice of mitral regurgitation. 3D FC surface computation was performed on parallel slices through the 3D data set at aliasing velocities (14-48 cm/s) selected to maximize the regularity and minimize lateral dropout of the visualized 3D FC at 5 points per cardiac cycle. Using continuous wave velocity for each, 3D-calculated EOA was compared with EOA determined by using continuous wave Doppler and the flow rate from a reference ultrasonic flow meter. Simultaneous digital video images were also recorded to define the actual orifice size for 9 stroke volumes (15-55 mL/beat with maximum flow rates 45-182 mL/s). RESULTS: Over the 9 pulsatile flow states and 3 orifices, 3D FC EOAs (0.05-0.63 cm(2)) from different phases of the cardiac cycle in each pump setting correlated well with reference EOA (r = 0.89-0.92, SEE = 0.027-0.055cm(2)) and they also correlated well with digital video images of the actual orifice peak (r = 0.97-0.98, SEE = 0.016-0.019 cm(2)), although they were consistently smaller, as expected by the contraction coefficient. CONCLUSION: The digital 3D FC method can accurately predict flow rate, and, thus, EOA (in conjunction with continuous wave Doppler), because it allows direct FC surface measurement despite temporal variability of FC shape.

Blood Flow Velocity↗

MRI of congenital heart disease: a paradigm of collaboration. new suggestions for a team approach from Madigan Army Medical Center.

Over the past decade, there has been increasing use of cardiac MRI in the evaluation of children with congenital heart disease. There has also been an increased number of radiologists and pediatric cardiologists desiring to perform cardiac MRI in the evaluation of these patients. At the present time, the number of pediatric cardiologists and radiologists fully trained in the use of MRI studies for CHD is inadequate to provide this modality at all institutions with MRI capabilities. This article describes the collaborative approach between pediatric cardiology and radiology at Madigan Army Medical Center and its implications for patient care and credentialing.

Cooperative Behavior↗

Report from the First International Conjoint Conference on Cardiovascular Magnetic Resonance and Echocardiography.

The opinions formulated in this conference represent expressions of promise and enthusiasm about charting the course for the future of cardiovascular imaging and the role that might be played by CMR and echocardiography. All attendees agreed that this conference provided a novel venue for friendly debate and discussion in an open forum that could facilitate research and clinical service planning, and that other similar conferences should be held to focus on additional methodologies and topics. Indeed, planning is already underway for a Second Conference with comparative CMR and nuclear imaging as a focus.

Cardiovascular Diseases↗

Accuracy of real-time three-dimensional echocardiography for quantifying right ventricular volume: static and pulsatile flow studies in an anatomic in vitro model.

OBJECTIVE: The complex structural geometry of the right ventricle hinders accurate assessment of right ventricular volume and function on conventional two-dimensional echocardiography. We sought to evaluate the accuracy of real-time three-dimensional echocardiography for quantifying the volume of the right ventricle in an in vitro experimental study. METHODS: We developed 39 anatomically accurate latex phantoms of human and porcine right ventricles (range, 24-108 mL) for 39 static and 10 pulsatile models. Real-time three-dimensional scanning was performed with the models placed in a water bath and with a 3.5-MHz probe. In the dynamic models a pulsatile flow pump generated 2 different stroke volumes (29 and 64 mL/beat). Static chamber volumes and stroke volumes were verified by water displacement, which served as a reference standard. Three-dimensional echo right ventricle volumes were determined by tracing derived B- and C-scans, using the Simpson rule. RESULTS: Multiple regression analyses showed an excellent correlation between real-time three-dimensional echocardiographic determinations and the static volumes (B-scan, r = 0.99; C-scan, r = 0.98; P < .001), as well as stroke volumes in the dynamic model (B-scan, r = 0.90; C-scan, r = 0.86; P < .001). However, the C-scans tended to underestimate cavity and stroke volumes more than the B-scans (mean difference for static volume: B-scan, 1.4% +/- 9.8%; C-scan, -7.4% +/- 8.0%; P < .001; mean difference for stroke volumes: B-scan, 3.0% +/- 19.1%; C-scan, -2.5% +/- 20.9%; P < .001). CONCLUSIONS: Real-time three-dimensional echocardiography can accurately quantify right ventricle cavity volumes and stroke volumes without geometric assumptions.

Animals↗

Assessment of pulmonary artery stenosis using freehand "flock of birds" digital color three-dimensional echocardiographic reconstruction.

Pulmonary artery (PA) trunk or branch PA stenosis is commonly found in patients with congenital heart disease. The aim of the present study was to evaluate the freehand "Flock of Birds" color Doppler three-dimensional (3D) reconstruction on a modeled-segment imitating PA stenosis. First, a PA model was created from latex tubes to simulate the main PA and its main branches with baseline cross-sectional areas (CSA) of 0.7 cm2. A series of narrowed segments in the right and left PA were created. The cross-sections of the smallest area ranged from 0.13 to 0.59 cm2 and stenotic segmental length ranged from 0.17 to 1.80 cm. The dimensions of these elements mounted on to the model were verified by intravascular ultrasound (IVUS) imaging. Next, pulsatile flows at 60 beats/ min were generated through the system. A GE/VingMed System FiVe with magnetic locator system (Flock of Birds) on a 3.5 MHz transducer was used to acquire a freehand sweep for ECG gated 3D data acquisition of color Doppler flows through the model. The images were reconstructed by EchoPac 3D software and the morphology of the stenotic elements were determined. The results revealed that the narrowest CSA determined by the 3D color flow cast of the pulmonary artery were in excellent agreement with IVUS CSA (r = 0.98, p < 0.001, SEE = 0.04 cm2). The stenotic length estimated from 3D was also in good agreement with the IVUS (r = 0.98, p < 0.001, SEE = 0.03 cm). In addition, complex morphology of the stenosis was well visualized by this technique. As a result, the noninvasive free-hand digital color 3D echocardiography can be adopted for the accurate assessment of the severity and morphology of PA stenosis in patients with congenital heart diseases.

Echocardiography, Doppler, Color↗