Professor Peter Choyce: an early pioneer of intraocular lenses and corneal/refractive surgery.

Professor Peter Choyce, FRCS, DOMS, MS, was one of the pioneers of intraocular lens implant surgery. He developed an interest in artificial lens implantation following cataract surgery, a procedure that was widely criticized by the ophthalmic establishment in the UK, Europe, North America and other countries. Owing to the opposition to the intraocular lenses, Peter Choyce together with Sir Harold Ridley co-founded the International Intraocular Implant Club in 1966, which was responsible for the gradual acceptance of artificial lens implantation. Peter Choyce developed several models of intraocular lens, but did not patent the majority of them. The Choyce Mark IX, manufactured by Rayner Intraocular Lenses, became the first US Food and Drug Administration-approved intraocular lens in 1981. A review of Peter Choyce's record confirms a significant number of original innovations in the field of anterior segment surgery, including many procedures taken for granted today, but not associated with his name. These include early work on both kerato- and intraocular lens-refractive procedures, keratoprosthesis, pioneering paediatric implant procedures and others. Unfortunately his tenacious adherence to anterior chamber lens technology, while in general clinically sound, caused many to question his influence and hence he remained poorly understood even until after his death. He passed away on 8 August 2001 after a long fight with colon cancer. In this article, we provide evidence and elaborate Peter Choyce's accomplishments, which places him as one of the most innovative ophthalmologist in his surgical field in the twentieth century.

Cornea↗

Surface calcification of silicone plate intraocular lenses in patients with asteroid hyalosis.

PURPOSE: To report three cases in which a silicone-plate lens was explanted because of whitish deposits on the posterior optic surface. DESIGN: Observational case series with clinicopathological correlation. PATIENTS AND METHODS: In the three instances, the deposits were observed at least 2 years after uneventful cataract surgery. All of the patients had unilateral mild asteroid hyalosis in the concerned eye. After explantation of the lenses, gross and light microscopic analyses were performed. The posterior optic surfaces of the lenses also underwent scanning electron microscopy coupled with energy dispersive x-ray spectroscopy for analysis of the elemental composition of the deposits. RESULTS: Gross and light microscopic analyses revealed well-demarcated areas of whitish deposits on the posterior optic surface of the lenses, as well as multiple pits caused by Neodymium:yttrium aluminum garnet laser treatments. The deposits formed an amorphous layer with a "crustlike" appearance, which was confirmed by scanning electron microscopy. X-ray spectroscopy analyses demonstrated the composition of the deposits to be similar to hydroxyapatite. CONCLUSIONS: The material opacifying the lenses was probably derived from the asteroid bodies or from a similar process that results in this vitreous condition. We were unaware of this association between asteroid hyalosis and late postoperative dystrophic calcification of silicone lenses.

Aged↗

Removal times and techniques of a viscoadaptive ophthalmic viscosurgical device.

PURPOSE: To analyze removal techniques for Healon5 (sodium hyaluronate 2.3%). SETTING: Center for Research on Ocular Therapeutics and Biodevices, Charleston, South Carolina, USA, and Department of Ophthalmology, Ruprecht-Karls-University, Heidelberg, Germany. METHODS: In a standardized laboratory setup, the Miyake-Apple posterior view video technique in human autopsy eyes was used to evaluate removal of an ophthalmic viscosurgical device (OVD) from capsular bags implanted with poly(methyl methacrylate), silicone, and acrylic intraocular lenses (IOLs). Healon5 was stained with fluorescein for better visualization. Open-sky preparation and an Alcon Legacy Series 20000 phaco machine with a flow rate of 25 mL/minute and a vacuum setting of +500 mm Hg (maximum irrigation/aspiration [I/A]) were used. With Technique 1, the I/A tip was placed on the center of the IOL and maximum aspiration was applied. With Technique 2 (modified rock 'n roll technique), the I/A tip was moved in quick circular movements on top of the IOL to break the OVD chains and facilitate aspiration. RESULTS: With Technique 1, the mean removal time was 59.0 seconds +/- 23.1 (SD) and with Technique 2, 23.6 +/- 10.3 seconds (P =.004). The removal time of Healon5 correlated with the IOL material. With Technique 2, removal was fastest with silicone IOLs (13.5 +/- 2.1 seconds) followed by PMMA IOLs (17.5 +/- 2.1 seconds). With acrylic IOLs, remnants of the OVD trapped behind the IOL optic resulted in a longer removal time of 34.1 +/- 1.2 seconds. CONCLUSIONS: Healon5 was completely removed from the capsular bag with the modified rock 'n roll technique. With acrylic IOLs, remnants can be trapped behind the optic and may be overlooked with an unstained OVD. Aspiration behind the optic is recommended with this IOL type.

Acrylic Resins↗

Capsular bag opacification after experimental implantation of a new accommodating intraocular lens in rabbit eyes.

PURPOSE: To evaluate the development of capsular bag opacification in rabbit eyes after implantation of an intraocular lens (IOL) designed to minimize contact between the anterior capsule and the IOL and ensure expansion of the capsular bag. SETTING: David J. Apple, MD Laboratories for Ophthalmic Devices Research, John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA. METHODS: Ten New Zealand white rabbits had a study IOL (new accommodating silicone IOL [Synchrony, Visiogen, Inc.]) implanted in 1 eye and a control IOL (1-piece plate silicone IOL with large fixation holes) implanted in the other eye. Intraocular lens position, anterior capsule opacification (ACO), and posterior capsule opacification (PCO) were qualitatively assessed using slitlamp retroillumination photographs of the dilated eyes. Anterior capsule opacification and PCO were graded on a 0 to 4 scale after the eyes were enucleated (Miyake-Apple posterior and anterior views after excision of the cornea and iris). The eyes were also evaluated histopathologically. RESULTS: The rate of ACO and PCO was significantly higher in the control group. Fibrosis and ACO were almost absent in the study group; the control group exhibited extensive capsulorhexis contraction, including capsulorhexis occlusion. Postoperative IOL dislocation into the anterior chamber and pupillary block syndrome were observed in some eyes in the study group. CONCLUSIONS: The special design features associated with the study IOL appeared to help prevent PCO. Complications in the study group were probably caused by the increased posterior vitreous pressure in rabbit eyes compared to human eyes and the relatively large size of the study IOL relative to the anterior segment of rabbit eyes.

Animals↗

Single-piece hydrophobic acrylic intraocular lens explanted within the capsular bag: case report with clinicopathological correlation.

A 74-year-old woman had uneventful phacoemulsification with implantation of a single-piece hydrophobic acrylic intraocular lens (IOL) (SA30AL) in her left eye. Two weeks after the surgery, the patient presented for ophthalmological consultation reporting pseudophakic dysphotopsia, which she had subjectively noted since surgery. Explantation/exchange of the IOL was performed 3 months after the surgery. The IOL was strongly attached to the capsule, which was fibrotic and contracted; explantation of the capsular bag complex in toto was done. To our knowledge, this is the first case of explantation of this IOL design with clinicopathological correlation.

Aged↗

Correlation between different measurements within the eye relative to phakic intraocular lens implantation.

PURPOSE: To obtain measurements of the white-to-white distance and the anterior chamber and ciliary sulcus diameters in phakic human eyes obtained post-mortem to find a correlation between these measurements. SETTING: David J. Apple, MD Laboratories for Ophthalmic Devices Research, John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA. METHODS: Twenty-two phakic human eyes obtained from eye banks within 24 hours of death were evaluated. The following measurements were performed: white-to-white distance, anterior chamber diameter with a plastic sizer after a small limbal incision, and anterior chamber and ciliary sulcus diameters after fixation and sagittal section of the eyes. The first 10 eyes were studied at the 6 o'clock to 12 o'clock meridian and the last 12 eyes, at the 3 o'clock to 9 o'clock meridian. RESULTS: A positive correlation was found between the white-to-white measurements and the anterior chamber diameter in the 10 eyes studied at the 6 o'clock to 12 o'clock meridian but not in the 12 eyes studied at the 3 o'clock to 9 o'clock meridian. The latter is the meridian frequently used by surgeons to perform white-to-white measurements and thus choose the overall size of the phakic intraocular lens to be implanted. No correlation was found between the white-to-white measurements and the ciliary sulcus diameter in the 2 meridians. CONCLUSION: Experimental studies using cadaver eyes are helpful in evaluating sizing techniques for phakic IOL implantation as well as in better understanding the anatomical relationships between ocular structures.

Aged↗

Pathological evaluation of postmortem human eyes implanted with a new single-piece hydrophobic acrylic lens.

PURPOSE: To report the pathological findings in 14 human cadaver eyes implanted with a single-piece AcrySof(Alcon Laboratories) posterior chamber intraocular lens (IOL). SETTING: David J. Apple, MD Laboratories for Ophthalmic Devices Research, John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA. METHODS: Fourteen human autopsy eyes implanted with a single-piece AcrySof (SA30AL) IOL were evaluated. The eyes were sectioned at the equatorial plane, and the anterior segment containing the IOL in the capsular bag was evaluated from a posterior perspective (Miyake-Apple view) and from an anterior perspective (surgeon's view) after removal of cornea and iris. They were then processed through paraffin, sectioned, and stained with hematoxylin-eosin, periodic acid-Schiff, and Masson's trichrome and examined under light microscopy. RESULTS: All IOLs had symmetric in-the-bag fixation. Slight decentration was measured in 1 eye, which also had an anterior capsule tear. Grade 1 anterior capsule opacification was present in 9 eyes. No central posterior capsule opacification or posterior capsule folds were observed in any eye. Soemmering's ring formation was observed in 5 eyes. Zonular stretch caused by different degrees of capsular bag contraction was present in 4 eyes without decentration of the IOL. CONCLUSIONS: Analyses of pseudophakic cadaver eyes from the posterior (Miyake-Apple) view, complemented by microscopic analyses, proved useful in the evaluation of IOL-capsular bag interaction. These studies are more important in cases of newly introduced lens designs.

Anterior Eye Segment↗

Capsulorhexis ovaling and capsular bag stretch after rigid and foldable intraocular lens implantation: experimental study in pediatric human eyes.

PURPOSE: To compare the amount of capsulorhexis ovaling and capsular bag stretch produced by various intraocular lenses (IOLs) implanted in pediatric human eyes obtained post-mortem. SETTING: David J. Apple, MD Laboratories for Ophthalmic Devices Research, John A. Moran Eye Center, Salt Lake City, Utah, USA. METHODS: In this nonrandomized comparative study, 16 pediatric human eyes obtained postmortem were divided into 2 groups: Eight eyes were obtained from children younger than 2 years (Group A), and 8 eyes were obtained from children older than 2 years (Group B). All eyes were prepared according to the Miyake-Apple posterior video technique. Six types of rigid and foldable posterior chamber IOLs manufactured from poly(methyl methacrylate) (single-piece), silicone (plate and loop haptics), and hydrophobic acrylic (single-piece and 3-piece AcrySof, Alcon Laboratories) biomaterials were implanted. The capsulorhexis opening and capsular bag diameters were measured before IOL implantation and after in-the-bag IOL fixation with the haptics (or the main axis) at the 3 to 9 o'clock meridian. The percentage of ovaling of the capsulorhexis opening was calculated by noting the difference in the opening's horizontal diameter before and after IOL implantation. The percentage of capsular bag stretch was also calculated by noting the difference in the horizontal capsular bag diameter before and after IOL implantation. RESULTS: All IOLs produced ovaling of the capsulorhexis opening and stretching of the capsular bag parallel to the IOL haptics. There were significant differences in capsulorhexis ovaling and capsular bag stretch (P<.001, analysis of variance) between the 6 IOL types in each group of eyes. The postimplantation difference was significant only between the single-piece hydrophobic acrylic IOL (AcrySof) and the other IOLs. The single-piece hydrophobic acrylic IOL was associated with significantly less capsulorhexis ovaling and capsular bag stretch in both groups (mean 12.06% +/- 0.59% [SD] and 7.6% +/- 1.47%, respectively). CONCLUSIONS: Modern rigid and foldable IOLs designed for the adult population implanted in the capsular bag of infants and children produced variable degrees of capsulorhexis ovaling and capsular bag stretch. The Miyake-Apple posterior video technique confirmed the well-maintained configuration of the capsular bag (with minimal ovaling) after implantation of a single-piece hydrophobic acrylic IOL because of its flexible haptic design.

Capsulorhexis↗

Posterior capsule opacification in rabbit eyes implanted with hydrophilic acrylic intraocular lenses with enhanced square edge.

PURPOSE: To evaluate the development of posterior capsule opacification (PCO) after implantation of single-piece hydrophilic acrylic intraocular lenses (IOLs) with an enhanced square edge. SETTING: John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA. METHODS: The standard 570H Centerflex (Rayner Ltd.) design was compared to 2 new designs with enhanced square edges: the 570E and the 570C. Ten IOLs of each type were implanted in a randomized manner by the same surgeon in 15 pigmented rabbits. After a follow-up of 3 weeks, the rabbits were killed and the eyes were analyzed from the posterior view. The intensity of central PCO, peripheral PCO, and Soemmering's ring formation was graded from 0 to 4. The area of Soemmering's ring was graded from 0 to 4 based on the number of quadrants involved. Other parameters analyzed were capsulorhexis coverage of the IOL edge and IOL centration and fixation. Results from the posterior view were complemented by histopathological evaluation. RESULTS: Posterior capsule opacification was lowest in the 570C group, highest in the 570H group, and intermediate in the 570E group. There was a statistically significant difference between the 3 groups in peripheral PCO (P = .039). No significant difference was found between the groups in the other parameters analyzed. When cell ingrowth occurred with the 570H, it started at the optic-haptic junctions, as observed during the clinical follow-up and confirmed by gross and histopathological analyses. CONCLUSIONS: The square optic edge is the most important IOL design feature for PCO prevention. However, it should be present for 360 degrees around the IOL optic to provide an effective barrier effect.

Acrylic Resins↗

Removal times for a dispersive and a cohesive ophthalmic viscosurgical device correlated with intraocular lens material.

PURPOSE: To investigate the removal times of ophthalmic viscosurgical devices (OVDs) with different intraocular lens (IOL) designs and materials. SETTING: Center for Research on Ocular Therapeutics and Biodevices, Department of Ophthalmology, Storm Eye Institute, Medical University of South Carolina, Charleston, South Carolina, USA, and Heidelberg IOL & Refractive Surgery Research Group, Department of Ophthalmology, Ruprecht-Karls-University of Heidelberg, Heidelberg, Germany. METHODS: In a standardized laboratory setup, the Miyake-Apple posterior view video technique was used to evaluate OVD removal from capsular bags in human autopsy eyes implanted with poly(methyl methacrylate) (PMMA), silicone, and acrylic IOLs. The cohesive OVD ProVisc (sodium hyaluronate 1.0%) and the dispersive OVD Viscoat (sodium hyaluronate 3.0% and chondroitin sulfate 4.0%) were stained with fluorescein for better visualization. The open-sky preparation and an Alcon Series 20000 Legacy phaco machine with a flow rate of 25 mL/min and a vacuum setting of +500 mm Hg (maximum irrigation/aspiration) were used. The time needed for complete removal of the cohesive and dispersive OVDs with each IOL type was measured and analyzed statistically. RESULTS: The mean removal times for both OVDs were as follows: Alcon MZ60BD PMMA IOL-25.0 seconds +/- 3.7 (SD) (Viscoat), 15.9 +/- 6.9 seconds (ProVisc); Alcon AcrySof MA60BM IOL-35.5 +/- 10.0 seconds (Viscoat), 25.6 +/- 4.7 seconds (ProVisc); Chiron/Bausch & Lomb C1043 silicone IOL-46.5 +/- 10.5 seconds (Viscoat), 17.3 +/- 2.1 seconds (ProVisc); AMO SI-30 silicone IOL-33.5 +/- 3.1 seconds (Viscoat), 15.3 +/- 6.3 seconds (ProVisc); and Pharmacia 912 silicone IOL-18.3 +/- 5.8 seconds (Viscoat), 19.8 +/- 4.3 seconds (ProVisc). CONCLUSIONS: Differences in OVD removal times were detected. The removal time for the cohesive OVD correlated with the IOL material. Overall, the time needed for complete removal was significantly longer for the dispersive OVD than for the cohesive OVD.

Acrylic Resins↗

Analysis of the capsule edge after Fugo plasma blade capsulotomy, continuous curvilinear capsulorhexis, and can-opener capsulotomy.

PURPOSE: To compare the quality of the edges of anterior capsulotomies performed in porcine eyes using 3 different techniques. SETTING: David J. Apple, MD Laboratories for Ophthalmic Devices Research, John A. Moran Eye Center, Department of Ophthalmology and Visual Sciences, University of Utah, Salt Lake City, Utah, USA. METHODS: Four porcine eyes were submitted to the center in 10% neutral buffered formalin. The cornea of the eyes had been removed, and a continuous capsulotomy had been performed in each eye using the Fugo plasma blade. To provide morphologic correlation, 4 additional porcine eyes were used in the study. In 2, a manual continuous curvilinear capsulorhexis (CCC) was performed after the cornea or cornea/iris was removed and in the other 2, a can-opener capsulotomy (COC) was performed. The eyes were then placed in 10% neutral buffered formalin. Gross (macroscopic) and microscopic analysis of each eye was performed, and photographs were taken. One eye in each group was also prepared and analyzed under scanning electron microscopy (SEM). RESULTS: The capsulotomy margin in the Fugo blade group presented some regularly spaced tags directed centrally with smooth edges at the base. Such a configuration would not interfere with the dynamics of the capsulorhexis sphincter and would generally not lead to radial tears. The smooth and regular nature of the capsulotomy margin in the CCC group was confirmed by gross and microscopic examinations of the eyes. The capsulotomy margin in the COC group presented some sharp notches directed outward, irregularly spaced, and irregular in shape. These are known to have a tendency to extend and form radial tears. CONCLUSION: Although performance of an anterior capsulotomy with the Fugo blade was associated with some margin irregularities, the geometry of the centrally directed tags prevented them from becoming the site of radial tear formation. The base of the capsulotomy performed with the Fugo blade appeared to be almost as smooth and regular as in the CCC under SEM evaluation.

Animals↗

Late postoperative opacification of a hydrophilic acrylic (hydrogel) intraocular lens: a clinicopathological analysis of 106 explants.

PURPOSE: To report clinical, pathologic, histochemical, ultrastructural, and spectroscopic analyses of MemoryLens intraocular lenses (IOLs) explanted from patients who had visual disturbances caused by postoperative opacification of the lens optic. DESIGN: Noncomparative, large case series with clinicopathologic correlation. PARTICIPANTS: A total of 106 hydrophilic acrylic IOLs of the same design explanted from 106 different patients. All patients had decreased visual acuity at presentation approximately 2 years after cataract surgery, associated with a whitish fine granularity on the optical surfaces of the IOLs. METHODS: The explanted IOLs were submitted to the John A. Moran Eye Center and were examined under light microscopy, histochemically, and with scanning electron microscopy (SEM) equipped with an energy dispersive x-ray spectroscopy detector with light element capabilities (EDS). MAIN OUTCOME MEASURES: The IOLs were examined for distribution, structure, and composition of the deposits causing opacification of their optic components. RESULTS: The average interval between lens implantation and opacification was 25.8+/-11.9 months. The most frequently associated medical and ophthalmic conditions were diabetes and glaucoma. However, some patients did not have any preexisting medical or ophthalmic conditions. Most of the IOLs had been implanted in 1999 and 2000. Microscopic analyses revealed the presence of multiple fine, granular deposits of variable sizes on the anterior and posterior optic surfaces, especially on the anterior surface. The deposits stained positive for calcium. The EDS confirmed the presence of calcium and phosphate within the deposits. CONCLUSIONS: The results obtained suggest the surface deposits to be composed, at least in part, by calcium and phosphate. A special polishing technique used in the manufacture of most of these IOLs may have caused changes in the lens surface leading to deposit formation. Further studies should be undertaken to confirm this hypothesis.

Acrylic Resins↗

Evaluation of preoperative and postoperative prophylactic regimens for prevention and treatment of diffuse lamellar keratitis.

PURPOSE: To investigate preoperative and postoperative prophylactic treatment with different pharmacological agents before flap cutting and exposure to a diffuse lamellar keratitis (DLK) causative agent. SETTING: Magill Research Center for Vision Correction, Storm Eye Institute, Medical University of South Carolina, Charleston, South Carolina, USA. METHODS: The study comprised 48 eyes of 24 Dutch-belted rabbits. Three days before a corneal flap was cut and the corneal interface was exposed to Pseudomonas aeruginosa lipopolysaccharide endotoxin, a DLK causative agent, the eyes were randomly assigned to treatment with a mast-cell stabilizer, a nonsteroidal antiinflammatory drug (NSAID), or a corticosteroid or left without treatment as controls. The treatment was maintained throughout the 1-week follow-up. Slitlamp examinations and photographs were performed at 1, 3, 5, and 7 days; DLK was graded by a masked observer from 0 (no DLK) to IV. Corneal interface scrapings were performed in selected eyes on day 7. RESULTS: At the end of the follow-up, 36 eyes were available for evaluation. At 1 week, 100% of the control eyes and the eyes treated with the mast-cell stabilizer developed DLK; in the NSAID-treated and corticosteroid-treated eyes, the DLK rate was 86% and 70%, respectively. At 1 day, the severity of DLK was significantly lower in eyes treated with the mast-cell stabilizer (0.44) and at 7 days, it was significantly lower in corticosteroid-treated eyes (0.3) than in the control group (1.5 and 1.4, respectively) (P<.05, Wilcoxon test). Corneal interface scraping from an eye with grade III DLK showed numerous inflammatory cells. CONCLUSIONS: Preoperative and postoperative treatment with corticosteroids significantly reduced the severity of DLK compared to the untreated control eyes in this animal model. Treatment with a mast-cell stabilizer and an NSAID had less effect on the postoperative course of DLK.

Animals↗

Endothelial cell integrity after phacoemulsification with 2 different handpieces.

PURPOSE: To investigate corneal endothelial cell loss in fresh phakic human autopsy cadaver eyes after phacoemulsification (PE) with a conventional handpiece or a new oscillatory handpiece. SETTING: Department of Ophthalmology, Storm Eye Institute, Medical University of South Carolina, Charleston, South Carolina, USA. METHODS: Twenty fresh phakic human autopsy globes were randomized to PE with a conventional handpiece (n = 10) or an oscillatory handpiece (n = 10). The main parameters evaluated were age, nucleus density, amount of ophthalmic viscosurgical device (OVD) used, and mean PE time and ultrasound (US) power. After surgery, the corneas were excised and the endothelia were vitally stained with trypan blue and alizarin red. Light microscopy was used to assess the endothelial cell loss. RESULTS: The mean age, density of the nucleus, OVD used, and US power were similar between the groups. The mean PE time was less with the NeoSoniX handpiece (0.71 minutes +/- 0.39 [SD]) than with the conventional handpiece (1.05 +/- 0.53 minutes). The mean number of dead endothelial cells was significantly lower in the oscillatory handpiece group (31.3 +/- 24.2 cells/mm(2)) than in the conventional handpiece group (60.4 +/- 46.8 cells/mm(2)) (P<.001, Mann-Whitney rank sum test). CONCLUSIONS: Less corneal endothelial cell loss occurred after PE with an oscillatory handpiece than with a conventional handpiece. Further randomized clinical trials are recommended to validate this study.

Adult↗

Deposits in artificial corneas: risk factors and prevention.

PURPOSE: To identify risk factors for calcium deposition and pigmented staining within AlphaCor artificial corneas. METHODS: Retrospective analysis of data from 72 AlphaCor implantations was conducted. Histological analysis of explants was performed. RESULTS: Eight cases of either intraoptic calcium or pigment deposition occurred in AlphaCor patients between 2.5 and 21 months after implantation. Four cases had diffuse white deposits, confirmed to be calcium and associated with prior coadministration of topical steroids and beta-blockers. The other four cases had brown deposits, associated with cigarette smoking and topical levobunolol. CONCLUSION: These findings led to changes in patient management protocols, surgeon training and patient information so as to minimize the risk of further occurrences. No further cases of white deposition have occurred after warning surgeons of the risk associated with certain topical therapy combinations. The risk of brown staining may be difficult to remove completely as it appears that environmental exposure to chemicals may cause deposition in addition to personal smoking habits and topical medications.

Adrenergic beta-Antagonists↗

Posterior capsule opacification: a review of the aetiopathogenesis, experimental and clinical studies and factors for prevention.

Posterior capsule opacification (PCO, secondary cataract, after cataract) is a nagging postsurgical complication following extracapsular cataract surgery (ECCE) and intraocular lens (IOL) implantation. PCO should be eliminated since it has deleterious sequelae and Neodynium: Yttrium Aluminium Garnet (Nd: YAG) laser treatment often is an unnecessary financial burden on the health care system. PCO following cataract surgery could be a major problem, since patient follow-up is difficult and the Nd:YAG laser is not always available. Advances in surgical techniques, IOL designs/biomaterials have been instrumental in bringing about a gradual and unnoticed decrease in the incidence of PCO. We strongly believe that the overall incidence of PCO and hence the incidence of Nd:YAG laser posterior capsulotomy is now rapidly decreasing - from 50% in the 1980s and early 1990s to less than 10% currently. Superior tools, surgical procedures, skills and appropriate IOL designs have all helped to significantly reduce this complication. In this article, we review the aetio pathogenesis, experimental and clinical studies and propose surgical and implant-related factors for PCO prevention. Careful application and utilisation of these factors by surgeons could lead to a significant reduction is secondary cataract, the second most common cause of visual loss worldwide.

Animals↗

Randomized, clinical trial of multiquadrant hydrodissection in pediatric cataract surgery.

PURPOSE: Evaluate efficacy of multiquadrant cortical-cleaving hydrodissection in pediatric cataract surgery. DESIGN: Randomized multicenter clinical trial. METHODS: Surgery performed at Iladevi Cataract & IOL Research Center (57 eyes, 42 patients) and Postgraduate Institute of Medical Education and Research (23 eyes, 17 patients). Study population comprised 59 consecutive patients (80 eyes) 12 years old and younger undergoing cataract aspiration. The intervention procedure involving envelope randomization was used to assign patients to multiquadrant cortical-cleaving hydrodissection (HY) (40 eyes), or no hydrodissection (HN) (40 eyes). The main outcome measures were as follows: (1) lens-substance removal time and volume of fluid used and (2) ease of lens substance removal. Presence or absence of residual fibers on the posterior capsule was recorded. RESULTS: The mean +/- standard deviation lens substance removal time was significantly less in the HY group (156.1 +/- 86.8 seconds) than in HN group (210.7 +/- 73.8 seconds; P =.003). Fluid used for lens substance removal was significantly less in the HY (91.0 +/- 47.5 ml) than in the HN group (156.9 +/- 87.2 ml; P <.001). In the HY group, lens substance removal was ranked as easy in 36 eyes (90.0%), average in 2 eyes (5.0%), and difficult in 2 eyes (5.0%). In the HN group, removal was easy in 19 eyes (47.5%), average in 12 eyes (30.0%), difficult in 5 eyes (12.5%), and very difficult in 4 (10.0%) eyes (P =.0005). Residual cortical fibers on the posterior capsule were noted in 12.5% of the HY group and 22.5% of HN group, but the difference was not statistically significant (P =.2). CONCLUSIONS: Multiquadrant cortical-cleaving hydrodissection decreases lens substance removal time, lessens fluid volume used for lens substance removal, and facilitates lens substance removal in pediatric cataract surgery.

Cataract↗