Search PubMed⌕ Search

Biomedical subjects

David Hattery

Publications and source records attributed to David Hattery.

2 recordsLinked to original sources

Tissue characterization by quantitative optical imaging methods.

Optical methods have a long history in the field of medical diagnosis. The biomolecular specificity possible with optical methods has been particularly valuable in microscopy and histopathology while in vivo imaging of deep structures has traditionally been the domain of X-ray and MRI. The use of optical methods in deep tissue has been limited by multiple-scattering which blurs or distorts the optical signal. New stochastic methods which account for multiple scattering have been developed that are extending the usefulness of optical methods deep into tissue. In optical mammography, photons may travel through 10 cm of tissue before arriving at the detector. We have developed a method for quantifying parameters of anomalous sites in breast tissue that may be used for functional characterization of tumors. In other work presented here, we are developing fluorescence based methods to detect and monitor tumor status. The immune response to a tumor is a target for fluorescently labeled specific antibodies. We have developed a method to localize the tumor site using CW fluorescence. Additionally, we have developed a method which uses time-resolved data and capitalizes on probe lifetime sensitivity to metabolic parameters such as pH and temperature to obtain functional information from the tumor site.

Algorithms↗

Differential oblique angle spectroscopy of the oral epithelium.

Increasing evidence suggests that inflammation may contribute to the process of carcinogenesis. This is the basis of several clinical trials evaluating potential chemopreventive drugs. These trials require quantitative assessments of inflammation, which, for the oral epithelium, are traditionally provided by histopathological evaluation. To reduce patient discomfort and morbidity of tissue biopsy procedures, we develop a noninvasive alternative using diffuse reflectance spectroscopy to measure epithelial thickness as an index of tissue inflammation. Although any optical system has the potential for probing near-surface structures, traditional methods of accounting for scattering of photons are generally invalid for typical epithelial thicknesses. We develop a single-scattering theory that is valid for typical epithelial thicknesses. The theory accurately predicts a distinctive feature that can be used to quantify epithelial thickness given intensity measurements with sources at two different angles relative to the tissue surface. This differential measure approach has acute sensitivity to small, layer-related changes in scattering coefficients. To assess the capability of our method to quantify epithelial thickness, detailed Monte Carlo simulations and measurements on phantom models of a two-layered structure are performed. The results show that the intensity ratio maximum feature can be used to quantify epithelial thickness with an error less than 30% despite fourfold changes in scattering coefficients and 10-fold changes in absorption coefficients. An initial study using a simple two-source, four-detector probe on patients shows that the technique has promise. We believe that this new method will perform well on patients with diverse tissue optical characteristics and therefore be of practical clinical value for quantifying epithelial thickness in vivo.

Algorithms↗