Search PubMed⌕ Search

Biomedical subjects

David H Russell

Publications and source records attributed to David H Russell.

34 records · Page 2Linked to original sources

Ratiometric pulsed alkylation mass spectrometry as a probe of thiolate reactivity in different metalloderivatives of Staphylococcus aureus pI258 CadC.

The coordination structure and reactivities of metal ligands in metal-sensing metalloregulatory coordination complexes may well dictate their biological properties. Here, we use the technique of ratiometric pulsed alkylation mass spectrometry (rPA-MS) to probe the structure and reactivities of metal coordination complexes formed by different metalloderivatives of Staphylococcus aureus plasmid pI258-encoded CadC, the metal-regulated transcriptional repressor of the cad operon. The cad operon provides resistance to large thiophilic heavy metal pollutants including Cd(II), Pb(II), and Bi(III). Two cysteines, an invariant Cys7 and a conserved Cys11, separated by three amino acids near the N-terminus of each subunit within dimeric CadC, donate two of the four coordination bonds to Cd(II) and Bi(III); in contrast, Cys11, but not Cys7, is excluded from the trigonal Pb(II) complex. rPA-MS reveals that Cys7 is strongly protected from alkylation in all metal complexes, Pb(II) being most effective, reducing k(app)(C7)by approximately 1000-fold relative to apo-CadC; in contrast, the reactivity of Cys11 is indistinguishable from that of apo-CadC, consistent with an S(3) coordination complex. Only in the tetrathiolate complexes formed by Cd(II) and Bi(III) is the reactivity of Cys11 appreciably reduced, but only by >or=10-fold. These data suggest that the Cys11-S(-)-metal coordination bond or that side of the coordination chelate in the trigonal Pb(II) complex defines a "weak point" in the chelate and thus might provide an entry site for potential metal ligand exchange reactions important for metal resistance in vivo. In contrast, Cys7 forms a tight coordination bond with all inducing metals, consistent with its role as a critical allosteric ligand in the metalloregulation of the operator/promoter binding.

Alkylation↗

Peak capacity of ion mobility mass spectrometry: the utility of varying drift gas polarizability for the separation of tryptic peptides.

Ion mobility mass spectrometry (IM-MS) peptide mass mapping experiments were performed using a variety of drift gases (He, N2, Ar and CH4). The drift gases studied cover a range of polarizabilities ((0.2-2.6) x 10(-24) cm3) and the peak capacities obtained for tryptic peptides in each gas are compared. Although the different gases exhibit similar peak capacities (5430 (Ar) to 7580 (N2)) in some cases separation selectivity presumably based on peptide conformers (or conformer populations), is observed. For example the drift time profiles observed for some tryptic peptide ions from aldolase (rabbit muscle) show a dependence on drift gas. The transmission of high-mass ions (m/z > 2000) is also influenced by increased scattering cross-section of the more massive drift gases. Consequently the practical peak capacity for IM-MS separation cannot be assumed to be solely a function of resolution and the ability of a gas to distribute signals in two-dimensional space; rather, peak capacity estimates must account for the transmission losses experienced for peptide ions as the drift gas mass increases.

Animals↗

Ion mobility-mass spectrometry applied to cyclic peptide analysis: conformational preferences of gramicidin S and linear analogs in the gas phase.

In this paper, we present an investigation of the gas-phase structural differences between cyclic and linear peptide ions by matrix-assisted laser desorption ionization-ion mobility-mass spectrometry. Specifically, data is shown for gramicidin S (cyclo-VOLFPVOLFP where phenylalanines are D rather than L-type amino acids and the O designates the non-standard amino acid ornithine) and five linear gramicidin S analogues. Results are interpreted as evidence for a beta-sheet (or beta-hairpin) conformational preference in both linear-protonated and sodiated-cyclic gramicidin S gas-phase peptides, and a preference for the protonated-cyclic peptide to adopt a collapsed, random coil-type conformation. A comparison with solution-phase circular dichroism measurements is performed, and structures similar to those observed in the gas phase appear to be favored in low-dielectric solvents such as 2,2,2-triflouroethanol. The utility of ion mobility-mass spectrometry (IM-MS) as a means of rapidly distinguishing between linear and cyclic peptide forms in also discussed.

Amino Acid Sequence↗

Resolution equations for high-field ion mobility.

An extension of current mobility resolution equations as they apply to high-field ion mobility spectrometry is presented. The new resolution expression is applied to arrival time distributions for ions having a large range of ion mobilities and mass-to-charge ratios (m/z). The results indicate that the new equation can be utilized to predict the mobility resolution over a broader range of applied electric fields than previous ion mobility resolution expressions.

Journal Article↗

A high repetition rate (1 kHz) microcrystal laser for high throughput atmospheric pressure MALDI-quadrupole-time-of-flight mass spectrometry.

Sample throughput has been increased in many areas of proteomics, but the last significant advance in lasers used for matrix-assisted laser desorption/ionization (MALDI) was the introduction of cartridge-type N2 lasers (337 nm, 4-ns pulse widths, 1-30-Hz repetition rates) more than a decade ago. This report describes the application of a 1-kHz repetition rate Nd:YAG laser (355 nm, <500-ps pulse widths) for atmospheric pressure MALDI-QqTOFMS, and data obtained are compared to a conventional nitrogen laser. For example, the signal intensity for angiotensin II using the 1-kHz laser was in some cases enhanced by a factor of 80 and high-quality data could be obtained in as little as 1 s.

Journal Article↗

Mass spectrometric analysis of putative capa-gene products in Musca domestica and Neobellieria bullata.

Neuropeptides of the capa-gene are typical of the abdominal neurosecretory system of insects. In this study, we investigated these peptides in two widely distributed and large pest flies, namely Musca domestica and Neobellieria bullata. Using a combination of MALDI-TOF and ESI-QTOF mass spectrometry, periviscerokinins and a pyrokinin were analyzed from single perisympathetic organ preparations. The species-specific peptide sequences differ remarkably between the related dipteran species. These differences could make it possible to develop peptide-analogs with group- or species-specific efficacy.

Amino Acid Sequence↗

Proteome analysis of Escherichia coli K-12 by two-dimensional native-state chromatography and MALDI-MS.

To identify proteins expressed in Escherichia coli K-12 MG1655 during exponential growth in defined medium, we separated soluble proteins of E. coli over two dimensions of native-state high-performance liquid chromatography, and examined the components of the protein mixtures in each of 380 fractions by peptide mass fingerprinting. To date, we have identified the products of 310 genes covering a wide range of cellular functions. Validation of protein assignments was made by comparing the assignments of proteins to specific first-dimension fractions to proteins visualized by two-dimensional gel electrophoresis. Co-fractionation of proteins suggests the possible identities of components of multiprotein complexes. This approach yields high-throughput gel-independent identification of proteins. It can also be used to assign identities to spots visualized by two-dimensional gels, and should be useful to evaluate differences in expressed proteome content and protein complexes among strains or between different physiological states.

Chromatography, High Pressure Liquid↗

Peak capacity of ion mobility mass spectrometry: separation of peptides in helium buffer gas.

Advances in the field of proteomics depend upon the development of high-throughput separation methods. Ion mobility-mass spectrometry is a fast separation method (separations on the millisecond time-scale), which has potential for peptide complex mixture analysis. Possible disadvantages of this technique center around the lack of orthogonality between separation based on ion mobility and separation based on mass. In order to examine the utility of ion mobility-mass spectrometry, the peak capacity (phi) of the technique was estimated by subjecting a large dataset of peptides to linear regression analysis to determine an average trend for tryptic peptides. This trend-line, along with the deviation from a linear relationship observed for this dataset, was used to define the separation space for ion mobility-mass spectrometry. Using the maximum deviation found in the dataset (+/-11%) the peak capacity of ion mobility-mass spectrometry is approximately 2600 peptides. These results are discussed in light of other factors that may increase the peak capacity of ion mobility-mass spectrometry (i.e. multiple trends in the data resulting from multiple classes of compounds present in a sample) and current liquid chromatography approaches to complex peptide mixture analysis.

Helium↗

Membrane charge and curvature determine interaction with acyl-CoA binding protein (ACBP) and fatty acyl-CoA targeting.

Although acyl-CoA binding protein (ACBP) stimulates utilization of long-chain fatty acyl-CoA by a variety of membrane-bound enzymes, it is not known whether ACBP directly interacts with membranes. To test this hypothesis, mouse recombinant (mr) ACBP was engineered to contain the native mouse ACBP amino acid sequence expressed as a fusion protein at high levels (>150 mg/L) in Escherichia coli. Purification and cleavage of the fusion tag resulted in mrACBP identical to native ACBP as shown by mass (10000.5 Da) and amino acid sequence (peptide mapping after proteolysis) determined by matrix-assisted laser desorption time of flight (MALDI-TOF) mass spectroscopy. The mrACBP was functionally active as shown by binding of cis-parinaroyl-CoA with high affinity, K(d) = 12 +/- 2 nM, at a single binding site, stimulating oleoyl-CoA utilization by microsomal glycerol-3-phosphate acyltransferase 3.2-fold and protecting oleoyl-CoA from microsomal acyl-CoA hydrolase. Direct interaction of mrACBP with membranes was demonstrated by two independent methods: (i) Circular dichroism showed an 8% increase in alpha-helix content of mrACBP in the presence of anionic phospholipid-rich, but not neutral, small unilamellar vesicles (SUV). (ii) Membrane filtration confirmed that mrACBP bound to anionic phospholipid-rich SUV but only weakly interacted with neutral SUV or large unilamellar vesicles (LUV), regardless of charge. (iii) The mrACBP-oleoyl-CoA complex transferred 2-3-fold more oleoyl-CoA to anionic phospholipid-rich SUV than to anionic phospholipid-rich LUV and neutral SUV or LUV. Conversely, mrACBP extracted less oleoyl-CoA from anionic phospholipid-rich SUV. Taken together, these data indicated for the first time that mrACBP interacted preferentially with anionic phospholipid-rich, highly curved membranes to facilitate transfer of ACBP-bound ligands.

Acyl Coenzyme A↗

Oligonucleotide analysis with MALDI-ion-mobility-TOFMS.

Matrix-assisted laser-desorption ionization followed by ion-mobility separation and time-of-flight mass analysis (MALDI-IM-TOFMS) has been used to characterize native and chemically modified DNA oligonucleotides up to eight bases in length. Mobility resolution between 20 and 30 can be used to separate oligonucleotides of different length, but not to differentiate between isomers or even different compositions of the same length. MALDI-IM-TOFMS does, however, have additional utility in the analysis of mixtures of DNA oligonucleotides and peptides, because these classes of molecules can be distinguished on the basis of differences in their mobility. Oligonucleotide sequencing is also possible by MALDI-IM-TOFMS. Ion signals corresponding to nucleobase losses, w-type, and y-type fragments were identified by use of differences in ion mobility. MALDI-IM-TOFMS was also used to resolve DNA-platinum adducts from the corresponding unmodified oligonucleotides.

Ions↗

Studies on the biosynthesis of phomoidride B (CP-263,114): evidence for a decarboxylative homodimerization pathway.

[reaction: see text]. Feeding experiments using a deuterium labeled C16 maleic anhydride and whole cell culture of ATCC 74256 led to the isolation of phomoidride B with deuterium incorporation at C(7) and C(19) as determined by 2H NMR and electrospray mass spectrometry. This result is in accord with a decarboxylative homodimerization of the C16 maleic anhydride as a key biosynthetic step leading to phomoidride B.

Decarboxylation↗

Observation of conserved solution-phase secondary structure in gas-phase tryptic peptides.

Results from ion mobility studies of tryptic peptides suggest that, in some cases, the gas-phase structures can be related to the solution-phase structure of the parent protein. The interpretation of ion mobility measurements is supported by results from molecular modeling and H/D exchange experiments on the same peptides. This study clearly illustrates the utility of IM-MS for screening complex mixtures for peptides having intrinsically stable secondary/tertiary structures, and/or posttranslational modification.

Amino Acid Sequence↗

Accurate mass measurement of DNA oligonucleotide ions using high-resolution time-of-flight mass spectrometry.

Matrix-assisted laser desorption/ionization (MALDI) and electrospray ionization (ESI) time-of-flight mass spectrometry (TOFMS) play an essential role in the analysis of biological molecules, not only peptides and proteins, but also DNA and RNA. Tandem mass spectrometry used for sequence analysis has been a major focus of technological developments in mass spectrometry, but accurate mass measurements by high-resolution TOFMS are equally important. This paper describes the role that high mass measurement accuracy can play in DNA composition assignment and discusses the influence of several parameters on mass measurement accuracy in both MALDI and ESI mass spectra. Five oligonucleotides (5-13mers) were used to test the resolving power and mass measurement accuracy obtained with MALDI and ESI instruments with reflectron TOF mass analyzers. The results from the experimental studies and additional theoretical calculations provide a basis to predict the practical utility of high-resolution TOFMS for the analysis of larger oligonucleotides.

DNA↗

Occurrence of insect kinins in the flesh fly, stable fly and horn fly-mass spectrometric identification from single nerves and diuretic activity.

MALDI-TOF mass spectrometric analysis of single lateral abdominal nerves (LANs) demonstrate the presence of the insect kinin Musdo-K in the housefly Musca domestica, and identify heretofore unknown insect kinins in two other Dipteran species as Musdo-K in the stable fly Stomoxys calcitrans and horn fly Haematobia irritans. The insect kinin native to the flesh fly Neobellieria bullata is identified as Drome-K. Musdo-K and Drome-K are identical save for the conservative substitution of Ser for Thr in position 2. The sequences of the insect kinins are, therefore, remarkably conserved throughout Dipterans. The in vitro Malpighian tubule fluid secretion activity of Musdo-K in the stable fly is similar to that in the housefly, whereas that of Drome-K is 30-fold more potent in the flesh fly than in the fruit fly. Given the structural identities of the kinins and CRF-like diuretic hormones of these Dipteran species, the housefly can serve as a model insect for the study of diuretic peptides and their functions in the stable fly and horn fly, both livestock pests.

Amino Acid Sequence↗

Distinguishing between phosphorylated and nonphosphorylated peptides with ion mobility-mass spectrometry.

Mass spectrometry has become an indispensable tool in identifying post-translationally modified proteins, but multiple peptide mass-mapping/peptide-sequencing experiments are required to answer questions involving the site and type of modification present. Here, we apply ion mobility-mass spectrometry (IM-MS), a high-throughput analysis method having high selectivity and sensitivity, to the challenge of identifying phosphorylated peptides. Ion mobility separation is based on the collision cross-section of the ion. Phosphorylation can result in a conformational change in gas-phase peptide ions, which can be detected by IM. To demonstrate this point, a peptide mixture containing a variety of peptide sequences is examined with IM-MS and molecular dynamics calculations. During the course of these studies, two classes of phosphopeptide were identified: (i) phosphorylated peptide ions that have conformers that differ from the nonphosphorylated ion and (ii) phosphorylated peptide ions that have conformations that are very similar to the nonphosphorylated peptide. The utility of IM-MS peptide mass mapping for identifying both types of phosphorylated peptides is discussed.

Amino Acid Sequence↗

Sub-femtomole peptide detection in ion mobility-time-of-flight mass spectrometry measurements.

Sensitivity and detection limit enhancements are obtained for peptides by performing high repetition rate (150 Hz) matrix-assisted laser desorption/ionization (MALDI) coupled with ion mobility-time-of-flight mass spectrometry. Absolute limits of detection (3sigma) for model peptides are on the order of 0.1 fmol of peptide deposited and represent a factor of 40-60 improvement over data obtained using typical low repetition (20 Hz) MALDI. This increase in sensitivity is demonstrated for two-dimensional MALDI-IM-TOFMS peptide mass mapping of bovine hemoglobin.

Angiotensin I↗