Search PubMed⌕ Search

Biomedical subjects

David E Clemmer

Publications and source records attributed to David E Clemmer.

At least 37 records · Page 2Linked to original sources

Evidence for unfolding and refolding of gas-phase cytochrome C ions in a Paul trap.

The folding pathways of gas-phase cytochrome c ions produced by electrospray ionization have been studied by an ion trapping/ion mobility technique that allows conformations to be examined over extended timescales (10 ms to 10 s). The results show that the +9 charge state emerges from solution as a compact structure and then rapidly unfolds into several substantially more open structures, a transition that requires 30-60 ms; over substantially longer timescales (250 ms to 10 s) elongated states appear to refold into an array of folded structures. The new folded states are less compact than those that are apparent during the initial unfolding. Apparently, unfolding to highly open conformations is a key step that must occur before +9 ions can sample more compact states that are stable at longer times.

Cytochromes c↗

Developing liquid chromatography ion mobility mass spectometry techniques.

When a packet of ions in a buffer gas is exposed to a weak electric field, the ions will separate according to differences in their mobilities through the gas. This separation forms the basis of the analytical method known as ion mobility spectroscopy and is highly efficient, in that it can be carried out in a very short time frame (micro- to milliseconds). Recently, efforts have been made to couple the approach with liquid-phase separations and mass spectrometry in order to create a high-throughput and high-coverage approach for analyzing complex mixtures. This article reviews recent work to develop this approach for proteomics analyses. The instrumentation is described briefly. Several multidimensional data sets obtained upon analyzing complex mixtures are shown in order to illustrate the approach as well as provide a view of the limitations and required future work.

Animals↗

Spontaneous anti-resolution in heterochiral clusters of serine.

Chirality plays an important role in the formation and stability of noncovalent clusters which are made of chiral molecules. It is shown that clusters can exhibit a preference for both homochirality and heterochirality. Serine cluster formation is dominated by the formation of heterochiral aggregates, with the exception of the previously observed homochiral serine octamer. Thus, the majority of serine clusters lead to chiral anti-resolution, or the racemic mixing of enantiomers.

Journal Article↗

Chiral enrichment of serine via formation, dissociation, and soft-landing of octameric cluster ions.

Chiral enrichment of serine is achieved in experiments that involve formation of serine octamers starting from non-racemic serine solutions. Serine octamers were generated by means of electrospray and sonic spray ionization of aqueous solutions of d(3)-L-serine (108 Da) and D-serine (105 Da) having different molar ratios of enantiomers. A cyclic process involving the formation of chirally-enriched octameric cluster ions and their dissociation, viz. Ser(1) --> Ser(8) --> Ser(1), allows serine monomers to be regenerated with increased enantiomeric excess as shown in two types of experiments: (1) Chiral enrichment in serine was observed in MS/MS/MS experiments in a quadrupole ion trap in which the entire distribution of serine octamers formed from non-racemic solutions was isolated, collisionally activated, and fragmented. Monomeric serine was regenerated with increased enantiomeric excess upon dissociation of octamers when compared with the enantiomeric composition of the original solution. (2) Chiral enrichment was observed in the products of soft-landing of mass-selected protonated serine octamers. These ions were generated by means of electrospray or sonic spray ionization, mass selected, and collected on a gold surface using ion soft-landing. Chiral enrichment of the soft-landed serine was established by redissolving the recovered material and comparing the intensities of protonated molecular ions of d(3)-L-serine and D-serine after APCI-MS analysis. Both of these experiments showed comparable results, suggesting that formation of serine octamers depends only on the enantiomeric composition of the serine solution and that the magnitude of the chiral preference is intrinsic to octamers formed from solutions of given chiral composition.

Ions↗

Nanoflow LC/IMS-MS and LC/IMS-CID/MS of protein mixtures.

A simple ion trap/ion mobility/time-of-flight (TOF) mass spectrometer has been coupled with nanoflow liquid chromatography to examine the feasibility of analyzing mixtures of intact proteins. In this approach proteins are separated using reversed-phase chromatography. As components elute from the column, they are electrosprayed into the gas phase and separated again in a drift tube prior to being dispersed and analyzed in a TOF mass spectrometer. The mobilities of ions through a buffer gas depend upon their collision cross sections and charge states; separation based on these gas-phase parameters provides a new means of simplifying mass spectra and characterizing mixtures. Additionally it is possible to induce dissociation at the exit of the drift tube and examine the fragmentation patterns of specific protein ion charge states and conformations. The approach is demonstrated by examining a simple three-component mixture containing ubiquitin, cytochrome c, and myoglobin and several larger prepared protein mixtures. The potential of this approach for use in proteomic applications is considered.

Animals↗

Development of high throughput dispersive LC-ion mobility-TOFMS techniques for analysing the human plasma proteome.

A technique that combines ion mobility spectrometry (IMS) with reversed-phase liquid chromatography (LC), collision-induced dissociation (CID) and mass spectrometry (MS) has been developed. The approach is described as a high throughput means of analysing complex mixtures of peptides that arise from enzymatic digestion of protein mixtures. In this approach, peptides are separated by LC and, as they elute from the column, they are introduced into the gas phase and ionised by electrospray ionisation. The beam of ions is accumulated in an ion trap and then the concentrated ion packet is injected into a drift tube where the ions are separated again in the gas phase by IMS, a technique that differentiates ions based on their mobilities through a buffer gas. As ions exit the drift tube, they can be subjected to collisional activation to produce fragments prior to being introduced into a mass spectrometer for detection. The IMS separation can be carried out in only a few milliseconds and offers a number of advantages compared with LC-MS alone. An example of a single 21-minute LC-IMS-(CID)-MS analysis of the human plasma proteome reveals approximately 20,000 parent ions and approximately 600,000 fragment ions and evidence for 227 unique protein assignments.

Chromatography, Liquid↗

A split-field drift tube for separation and efficient fragmentation of biomolecular ions.

A new ion mobility instrument that incorporates a low-field region for ion separation and a high-field region for collisional activation is described. In this approach, mixtures of ions are separated based on differences in their mobilities in a approximately 20-cm-long low-field ( approximately 5 V cm(-)(1)) region of a drift tube. As the ions approach the drift tube exit, they are exposed to a large focusing potential drop; at high fields, ions are efficiently collisionally activated and dissociate as they exit the drift tube. We have demonstrated this approach by examining the fragmentation pattern for electrosprayed bradykinin ions. These studies show that the activation process is highly tunable; it is possible to modulate the field such that precursor ion mass spectra as well as several high-field collision-induced fragmentation patterns can be obtained. The approach also appears to be a simple means of activating protein ions, as demonstrated by examining electrosprayed myoglobin ions.

Bradykinin↗

Development of high-sensitivity ion trap ion mobility spectrometry time-of-flight techniques: a high-throughput nano-LC-IMS-TOF separation of peptides arising from a Drosophila protein extract.

A linear octopole trap interface for an ion mobility time-of-flight mass spectrometer has been developed for focusing and accumulating continuous beams of ions produced by electrospray ionization. The interface improves experimental efficiencies by factors of approximately 50-200 compared with an analogous configuration that utilizes a three-dimensional Paul geometry trap (Hoaglund-Hyzer, C. S.; Lee, Y. J.; Counterman, A. E.; Clemmer, D. E. Anal. Chem. 2002, 74, 992-1006). With these improvements, it is possible to record nested drift (flight) time distributions for complex mixtures in fractions of a second. We demonstrate the approach for several well-defined peptide mixtures and an assessment of the detection limits is given. Additionally, we demonstrate the utility of the approach in the field of proteomics by an on-line, three-dimensional nano-LC-ion mobility-TOF separation of tryptic peptides from the Drosophila proteome.

Animals↗

Coupling capillary electrochromatography with electrospray Fourier transform mass spectrometry for characterizing complex oligosaccharide pools.

To deal with the complexity of the glycan mixtures released from glycoproteins, an efficient form of micro-column separations, capillary electrochromatography, has been combined with high-performance mass spectrometry (Fourier transform ion cyclotron resonance). Contour plots have been generated from the mixtures of O-linked oligosaccharides originated from bovine mucin and bile salt-stimulated lipase, a large glycoprotein enzyme.

Animals↗

Development of LC-IMS-CID-TOFMS techniques: analysis of a 256 component tetrapeptide combinatorial library.

Recent improvements in ion mobility/time-of-flight mass spectrometry techniques have made it possible to incorporate nano-flow liquid chromatography and collision induced dissociation techniques. This combination of approaches provides a new strategy for detailed characterization of complex systems--such as, combinatorial libraries. Our work uses this technology to provide a detailed analysis of a tetrapeptide library having the general form Xxx1-Xxx2-Xxx3-Xxx4 where Xxx1 = Glu, Phe, Val, Asn; Xxx2 = Glu, Phe, Val, Tyr; Xxx3 = Glu, Phe, Val, Thr; and Xxx4 = Glu, Phe, Val, Leu--a system that is expected to contain 256 different peptide sequences. The results corroborate the presence of many expected peptide sequences and indicate that some synthetic steps appear to have failed. Particularly interesting is the observation of a t-butyl protecting group on the tyrosine (Tyr) residue. It appears that most Tyr containing peptides that have this t-butyl group attached favor formation of [2M + 2H]2+ dimers, which can be readily distinguished from [M + H]+ monomers based on differences in their gas-phase mobilities. In this case, we demonstrate the use of the mobility differences between [2M + 2H]2+ and [M + H]+ ions as a signature for a failure of a synthetic step.

Amino Acid Sequence↗

Development of high-throughput liquid chromatography injected ion mobility quadrupole time-of-flight techniques for analysis of complex peptide mixtures.

The development of a multidimensional approach involving high-performance liquid chromatography (LC), ion mobility spectrometry (IMS) and tandem mass spectrometry is described for the analysis of complex peptide mixtures. In this approach, peptides are separated based on differences in their LC retention times and mobilities (as ions drift through He) prior to being introduced into a quadrupole/octopole/time-of-flight mass spectrometer. The initial LC separation and IMS dispersion of ions is used to label ions for subsequent fragmentation studies that are carried out for mixtures of ions. The approach is demonstrated by examining a mixture of peptides generated from tryptic digestion of 18 commercially available proteins. Current limitations of this initial study and potential advantages of the experimental approach are discussed.

Amino Acid Sequence↗

Gas-phase separations of protein and peptide ion fragments generated by collision-induced dissociation in an ion trap.

Ion mobility/time-of-flight mass spectrometry techniques have been used to examine distributions of fragment ions generated by collision-induced dissociation (CID) in a quadrupole ion trap. The mobility-based separation step prior to mass-to-charge (m/z) analysis reduces spectral congestion and provides information that complements m/z-based assignments of peaks. The approach is demonstrated by examining fragmentation patterns of insulin chain B (a 30-residue peptide), and ubiquitin (a protein containing 76 amino acids). Some fragments of ubiquitin show evidence for multiple stable conformations.

Gas Chromatography-Mass Spectrometry↗

Cis-trans signatures of proline-containing tryptic peptides in the gas phase.

High-resolution ion mobility/time-of-flight techniques were used to measure collision cross sections for 968 tryptic digest peptide ions obtained from digestion of common proteins. Here, we report a mobility signature that aids in identifying proline-containing peptides containing 4-10 residues. Of 129 peptides (< or = 10 residues in length) in the database that contain proline residues, 57% show multiple resolved features in the ion mobility distribution for at least one of the [M + H]+ or [M + 2H]2+ ions. These multiple features are attributed to different conformations that arise from populations of cis and trans forms of proline. The number of resolved peaks in the ion mobility distribution appears to be correlated with the peptide ion charge state and the number of proline residues in the peptide.

Animals↗

Prediction of peptide ion collision cross sections from topological molecular structure and amino acid parameters.

Quantitative structure-property relationships (QSPRs) have been developed to predict the ion mobility spectrometry (IMS) collision cross sections of singly protonated lysine-terminated peptides using information derived from topological molecular structure and various amino acid parameters. The primary amino acid sequence alone is sufficient to accurately predict the collision cross section. The models were built using multiple linear regression (MLR) and computational neural networks (CNNs). The best MLR model found contains six descriptors and predicts 94 of 113 peptides (83%) to within 2% of their experimentally determined values. The best CNN model using the same six descriptors predicts 105 of the 113 peptides (93%) to within 2% of their experimentally determined values. The best overall CNN model, using a different set of six descriptors, predicts 109 of the 113 peptides (96%) to within 2% of their experimentally determined values. In addition, this model can discriminate among peptides having identical amino acid composition, but differing in primary amino acid sequence. This represents a capability not found in previously described models. The descriptors used in the models presented may provide some insight into the nature of peptide ion folding in the gas phase.

Amino Acid Sequence↗

Quantifying peptides in isotopically labeled protease digests by ion mobility/time-of-flight mass spectrometry.

Ion mobility/time-of-flight techniques have been used to analyze mixtures of isotopically labeled peptides. The isotopic labels were generated by treatment of peptides with N-acetoxysuccinimide (or the deuterated analogue), which results in acetylation (or deuterioacetylation) of the primary amines (i.e., the N-terminus and lysine residues). The relative concentrations of a peptide in each sample are determined by comparing the peak intensities for isotopic pairs. An important consideration is that as mixtures become increasingly complex, isotopic pairs of peaks may overlap with other peaks in the mass spectrum. The influence of the acetyl and deuterioacetyl groups on the mobilities of peptides is considered. The coincidence in mobilities of isotopic pairs provides a means of distinguishing isotopic pairs from other isobaric interferences.

Acetylation↗

Coupling ion mobility separations, collisional activation techniques, and multiple stages of MS for analysis of complex peptide mixtures.

An ion trap/ion mobility/quadrupole/collision cell/time-of-flight mass spectrometer that incorporates a differentially pumped orifice-skimmer cone region at the back of the drift tube has been developed for the analysis of peptide mixtures. The combined approach allows a variety of strategies to be employed for collisionally activating ions, and fragments can be monitored by subsequent stages of mass spectrometry in a parallel fashion, as described previously (Anal. Chem. 2000, 72, 2737). Here, we describe the overall experimental approach in detail. Applications involving different aspects of the initial mobility separation and various collisional activation and parallel sequencing strategies are illustrated by examining several simple peptide mixtures and a mixture of tryptic peptides from beta-casein. Detection limits associated with various experimental configurations and the utility for analysis of complex systems are discussed.

Algorithms↗

Resolving isomeric peptide mixtures: a combined HPLC/ion mobility-TOFMS analysis of a 4000-component combinatorial library.

A reversed-phase high-performance liquid chromatography (HPLC) separation approach has been combined with ion mobility/time-of-flight (TOF) mass spectrometry in order to characterize a combinatorial peptide library designed to contain 4000 peptides of the general form NH2-Xxx-Xxx-XXX-CO2H, NH2-Ala-Xxx-Xxx-Xxx-CO2H, NH2-Ser-Ala-Xxx-Xxx-Xxx-CO2H and NH2-Leu-Ser-Ala-Xxx-Xxx-Xxx-CO2H (where Xxx represents a randomization over 10 different amino acids: Ala, Arg, Asp, Glu, Gly, Leu, Lys, Phe, Ser, and Val). Addition of the gas-phase mobility separation between the HPLC separation and TOF measurement dimensions makes it possible to resolve many peptide isomers that have identical retention times (and masses).

Chromatography, High Pressure Liquid↗

Conformational studies of Zn-ligand-hexose diastereomers using ion mobility measurements and density functional theory calculations.

Ion mobility studies and density functional theory calculations were used to study the structures of [Zn/diethylenetriamine/Hexose/Cl]+ complexes in an effort to probe differences in the three-dimensional conformations. This information allows us to gain insight into the structure of these complexes before collisional activation, which is the first step in understanding the stereoselective dissociations observed under collisionally activated conditions. The collision cross sections obtained from the ion mobility measurements showed that the mannose structure is more compact than the galactose and glucose complexes, respectively. Using density functional theory, candidate structures for each of the experimentally observed complexes were generated. Two criteria were used to determine the most likely structures of these complexes before activation: (1) The allowed relative energies of the molecules (between 0-90 kJ/mol) and (2) collision cross section agreement (within 2%) between the theoretically determined structures and the experimentally determined cross section. It was found that the identity of the monosaccharide made a difference in the overall conformation of the metal-ligand-monosaccharide complex. For glucose and galactose, metal coordination to O(6) was found to be favorable, with the monosaccharide occupying the 4C1 chair conformation, while for mannose, O(2) metal coordination was found with the monosaccharide in a B3,0 conformation. Coordination numbers varied between four and six for the Zn(II) metal centers. Given these results, it appears that the stereochemistry of the monosaccharide influences the conformation and metal coordination sites of the Zn(II)/monosaccharide/dien complex. These differences may influence the dissociation products observed under collisionally activated conditions.

Algorithms↗