Ultrasound-based guidance of intensity-modulated radiation therapy.

In ultrasound-guided intensity-modulated radiation therapy (IMRT) of prostate cancer, ultrasound imaging ascertains the anatomical position of patients during x-ray therapy delivery. The ultrasound transducers are made of piezoelectric ceramics. The same crystal is used for both ultrasound production and reception. Three-dimensional (3D) ultrasound devices capture and correlate series of 2-dimensional (2D) B-mode images. The transducers are often arranged in a convex array for focusing. Lower frequency reaches greater depth, but results in low resolution. For clear image, some gel is usually applied between the probe and the skin contact surface. For prostate positioning, axial and sagittal scans are performed, and the volume contours from computed tomography (CT) planning are superimposed on the ultrasound images obtained before radiation delivery at the linear accelerator. The planning volumes are then overlaid on the ultrasound images and adjusted until they match. The computer automatically deduces the offset necessary to move the patient so that the treatment area is in the correct location. The couch is translated as needed. The currently available commercial equipment can attain a positional accuracy of 1-2 mm. Commercial manufacturer designs differ in the detection of probe coordinates relative to the isocenter. Some use a position-sensing robotic arm, while others have infrared light-emitting diodes or pattern-recognition software with charge-couple-device cameras. Commissioning includes testing of image quality and positional accuracy. Ultrasound is mainly used in prostate positioning. Data for 7825 daily fractions of 234 prostate patients indicated average 3D inter-fractional displacement of about 7.8 mm. There was no perceivable trend of shift over time. Scatter plots showed slight prevalence toward superior-posterior directions. Uncertainties of ultrasound guidance included tissue inhomogeneities, speckle noise, probe pressure, and inter-observer variation. Some published studies detected improvement in treatment based on gastrointestinal toxicity and the reduction of prostate movement.

Humans↗

Effects of field parameters on IMRT plan quality for gynecological cancer: a case study.

Traditional external beam radiotherapy of gynecological cancer consists of a 3D, four-field-box technique. The radiation treatment area is a large region of normal tissue, with greater inhomogeneity over the treatment volume, which could benefit more with intensity-modulated radiation therapy (IMRT). This is a case report of IMRT planning for a patient with endometrial cancer. The planning target volume (PTV) spanned the intrapelvic and periaortic lymph nodes to a 33-cm length. Planning and treatment were accomplished using double isocenters. The IMRT plan was compared with a 3D plan, and the effects of field parameters were studied. Delineated anatomical contours included the intrapelvic nodes (PTV), bone marrow, small bowel, bladder, rectum, sigmoid colon, periaortic nodes (PTV), spinal cord, left kidney, right kidney, large bowel, liver, and tissue (excluding the PTVs). Comparisons were made between IMRT and 3D plans, 23-MV and 6-MV energies, zero and rotated collimator angles, different numbers of segments, and opposite gantry angle configurations. The plans were evaluated based on dosevolume histograms (DVHs). Compared with the 3D plan, the IMRT plan had superior dose conformity and spared the bladder and sigmoid colon embedded in the intrapelvic nodes. The higher energy (23 MV) reduced the dose to most critical organs and delivered less integral dose. Zero collimator angles resulted in a better plan than "optimized" collimator angles, with lower dose to most of the normal structures. The number of segments did not have much effect on isodose distribution, but a reasonable number of segments was necessary to keep treatment time from being prohibitively long. Gantry angles, when evenly spaced, had no noticeable effect on the plan. The patient tolerated the treatment well, and the initial complete blood count was favorable. Our results indicated that large-volume tumor sites may also benefit from precise conformal delivery of IMRT.

Adenocarcinoma↗

Cell-phone interference with pocket dosimeters.

Accurate reporting of personal dose is required by regulation for hospital personnel that work with radioactive material. Pocket dosimeters are commonly used for monitoring this personal dose. We show that operating a cell phone in the vicinity of a pocket dosimeter can introduce large and erroneous readings of the dosimeter. This note reports a systematic study of this electromagnetic interference. We found that simple practical measures are enough to mitigate this problem, such as increasing the distance between the cell phone and the dosimeter or shielding the dosimeter, while maintaining its sensitivity to ionizing radiation, by placing it inside a common anti-static bag.

Artifacts↗

Real-time 3D surface-image-guided beam setup in radiotherapy of breast cancer.

We describe an approach for external beam radiotherapy of breast cancer that utilizes the three-dimensional (3D) surface information of the breast. The surface data of the breast are obtained from a 3D optical camera that is rigidly mounted on the ceiling of the treatment vault. This 3D camera utilizes light in the visible range therefore it introduces no ionization radiation to the patient. In addition to the surface topographical information of the treated area, the camera also captures gray-scale information that is overlaid on the 3D surface image. This allows us to visualize the skin markers and automatically determine the isocenter position and the beam angles in the breast tangential fields. The field sizes and shapes of the tangential, supraclavicular, and internal mammary gland fields can all be determined according to the 3D surface image of the target. A least-squares method is first introduced for the tangential-field setup that is useful for compensation of the target shape changes. The entire process of capturing the 3D surface data and subsequent calculation of beam parameters typically requires less than 1 min. Our tests on phantom experiments and patient images have achieved the accuracy of 1 mm in shift and 0.5 degrees in rotation. Importantly, the target shape and position changes in each treatment session can both be corrected through this real-time image-guided system.

Algorithms↗

Dose sculpting with generalized equivalent uniform dose.

With intensity-modulated radiotherapy (IMRT), a variety of user-defined dose distribution can be produced using inverse planning. The generalized equivalent uniform dose (gEUD) has been used in IMRT optimization as an alternative objective function to the conventional dose-volume-based criteria. The purpose of this study was to investigate the effectiveness of gEUD optimization to fine tune the dose distributions of IMRT plans. We analyzed the effect of gEUD-based optimization parameters on plan quality. The objective was to determine whether dose distribution to selected structures could be improved using gEUD optimization without adversely altering the doses delivered to other structures, as in sculpting. We hypothesized that by carefully defining gEUD parameters (EUD0 and n) based on the current dose distributions, the optimization system could be instructed to search for alternative solutions in the neighborhood, and we could maintain the dose distributions for structures already satisfactory and improve dose for structures that need enhancement. We started with an already acceptable IMRT plan optimized with any objective function. The dose distribution was analyzed first. For structures that dose should not be changed, a higher value of n was used and EUD0 was set slightly higher/lower than the EUD value at the current dose distribution for critical structures/targets. For structures that needed improvement in dose, a higher to medium value of n was used, and EUD0 was set to the EUD value or slightly lower/higher for the critical structure/target at the current dose distribution. We evaluated this method in one clinical case each of head and neck, lung and prostate cancer. Dose volume histograms, isodose distributions, and relevant tolerance doses for critical structures were used for the assessment. We found that by adjusting gEUD optimization parameters, the dose distribution could be improved with only a few iterations. A larger value of n could lead to faster convergence and a medium value of n could result in a search in a broader area. Such improvement could also be achieved by optimization based on other criteria, but the gEUD-based method has the advantage of efficiency and flexibility. Therefore, gEUD-based optimization can be used as a tool to improve IMRT plans by adjusting the planning parameters, thereby making dose sculpting feasible.

Algorithms↗

A new approach in dose measurement and error analysis for narrow photon beams (beamlets) shaped by different multileaf collimators using a small detector.

Dose measurement for narrow stereotactic beams and intensity modulation radiotherapy beamlets is difficult and error-prone due to the lack of lateral electron equilibrium. A small detector position error and finite sensitive volume as well as the nonfocus collimation could result in considerable (> 10%) measurement errors. A new method is introduced here to measure the dose and error components so that the accuracy and precision of the dose measurement can be improved. Based on superposition principle, we can create exactly the small field of interest by subtraction of a reference open field (O-field) and two strip fields (S-fields) from the sum of four quadrant fields (Q-fields). The position effect on the dose measurement is determined by the standard deviation of the four Q-field readings. The collimator leaf-edge effect (LEE) is quantified by the difference between the readings of the two S-fields using a detector that has very small sensitive volume. The detector-volume effect can be analytically estimated from the integrals of the dose distributions of the two S-fields over the detector volume. Using a pinpoint ion chamber (PTW N31006) and a stereotactic silicon diode detector (Scanditronix, DEB050), we have measured scatter factors (SF) and tissue-maximum ratios for 6-MV x-ray fields with sizes of 3 x 3 and 6 x 6 mm2 shaped by a BrainLAB micromultileaf collimator (microMLC) (M3), 4.4 x 4.4 and 8.8 x 8.8 mm2 shaped by a 3DLine double-focus MLC, and 5 x 5 and 10 x 10 mm2 by a Varian Millennium MLC. Our experimental results demonstrate that the large errors are often caused by a small setup error or measuring point displacement from the central ray of the beam. The LEE is almost independent of the depth but closely related to the field size and the type of MLC. The volume effect becomes significant when the detector diameter is comparable to the half size of the small fields. Application of the new method using different detectors had achieved less than 8.3% total experiment error for all of the small fields of interest except for the SF of the 3 x 3 mm2 field from the pinpoint ion chamber that has 15% volume effect. Importantly, the new method using a solid water phantom is clinically convenient and highly reproducible.

Algorithms↗

Algorithm and performance of a clinical IMRT beam-angle optimization system.

This paper describes the algorithm and examines the performance of an intensity-modulated radiation therapy (IMRT) beam-angle optimization (BAO) system. In this algorithm successive sets of beam angles are selected from a set of predefined directions using a fast simulated annealing (FSA) algorithm. An IMRT beam-profile optimization is performed on each generated set of beams. The IMRT optimization is accelerated by using a fast dose calculation method that utilizes a precomputed dose kernel. A compact kernel is constructed for each of the predefined beams prior to starting the FSA algorithm. The IMRT optimizations during the BAO are then performed using these kernels in a fast dose calculation engine. This technique allows the IMRT optimization to be performed more than two orders of magnitude faster than a similar optimization that uses a convolution dose calculation engine. Any type of optimization criterion present in the IMRT system can be used in this BAO system. An objective function based on clinically-relevant dose-volume (DV) criteria is used in this study. This facilitates the comparison between a BAO plan and the corresponding plan produced by a planner since the latter is usually optimized using a DV-based objective function. A simple prostate case and a complex head-and-neck (HN) case were used to evaluate the usefulness and performance of this BAO method. For the prostate case we compared the BAO results for three, five and seven coplanar beams with those of the same number of equispaced coplanar beams. For the HN case we compare the BAO results for seven and nine non-coplanar beams with that for nine equispaced coplanar beams. In each case the BAO algorithm was allowed to search up to 1000 different sets of beams. The BAO for the prostate cases were finished in about 1-2 h on a moderate 400 MHz workstation while that for the head-and-neck cases were completed in 13-17 h on a 750 MHz machine. No a priori beam-selection criteria have been used in achieving this performance. In both the prostate and the head-and-neck cases, BAO is shown to provide improvements in plan quality over that of the equispaced beams. The use of DV-based objective function also allows us to study the dependence of the improvement of plan quality offered by BAO on the DV criteria used in the optimization. We found that BAO is especially useful for cases that require strong DV criteria. The main advantages of this BAO system are its speed and its direct link to a clinical IMRT system.

Algorithms↗

A fast dose calculation method based on table lookup for IMRT optimization.

This note describes a fast dose calculation method that can be used to speed up the optimization process in intensity-modulated radiotherapy (IMRT). Most iterative optimization algorithms in IMRT require a large number of dose calculations to achieve convergence and therefore the total amount of time needed for the IMRT planning can be substantially reduced by using a faster dose calculation method. The method that is described in this note relies on an accurate dose calculation engine that is used to calculate an approximate dose kernel for each beam used in the treatment plan. Once the kernel is computed and saved, subsequent dose calculations can be done rapidly by looking up this kernel. Inaccuracies due to the approximate nature of the kernel in this method can be reduced by performing scheduled kernel updates. This fast dose calculation method can be performed more than two orders of magnitude faster than the typical superposition/convolution methods and therefore is suitable for applications in which speed is critical, e.g., in an IMRT optimization that requires a simulated annealing optimization algorithm or in a practical IMRT beam-angle optimization system.

Algorithms↗

Intensity-modulated radiotherapy optimization with gEUD-guided dose-volume objectives.

Currently, most intensity-modulated radiation therapy systems use dose-volume (DV)-based objectives. Although acceptable plans can be generated using these objectives, much trial and error is necessary to plan complex cases with many structures because numerous parameters need to be adjusted. An objective function that makes use of a generalized equivalent uniform dose (gEUD) was developed recently that has the advantage of involving simple formulae and fewer parameters. In addition, not only does the gEUD-based optimization provide the same coverage of the target, it provides significantly better protection of critical structures. However, gEUD-based optimization may not be superior once dose distributions and dose-volume histograms (DVHs) are used to evaluate the plan. Moreover, it is difficult to fine-tune the DVH with gEUD-based optimization. In this paper, we propose a method for combining the gEUD-based and DV-based optimization approaches to overcome these limitations. In this method, the gEUD optimization is performed initially to search for a solution that meets or exceeds most of the treatment objectives. Depending on the requirements, DV-based optimization with a gradient technique is then used to fine-tune the DVHs. The DV constraints are specified according to the gEUD plan, and the initial intensities are obtained from the gEUD plan as well. We demonstrated this technique in two clinical cases: aprostate cancer and ahead and neck cancer case. Compared with the DV-optimized plan, the gEUD plan provided better protection of critical structures and the target coverage was similar. However, homogeneities were slightly poorer. The gEUD plan was then fine-tuned with DV constraints, and the resulting plan was superior to the other plans in terms of the dose distributions. The planning time was significantly reduced as well. This technique is an effective means of optimizing individualized treatment plans.

Adenocarcinoma↗