Search PubMed⌕ Search

Biomedical subjects

David D Sampson

Publications and source records attributed to David D Sampson.

9 recordsLinked to original sources

Synthetic aperture fourier holographic optical microscopy.

We report a new synthetic aperture optical microscopy in which high-resolution, wide-field amplitude and phase images are synthesized from a set of Fourier holograms. Each hologram records a region of the complex two-dimensional spatial frequency spectrum of an object, determined by the illumination field's spatial and spectral properties and the collection angle and solid angle. We demonstrate synthetic microscopic imaging in which spatial frequencies that are well outside the modulation transfer function of the collection optical system are recorded while maintaining the long working distance and wide field of view.

Fourier Analysis↗

Correlation of static speckle with sample properties in optical coherence tomography.

We present theoretical calculations, based on a random phasor sum model, which show that the optical coherence tomography speckle contrast ratio is dependent on the local density of scattering particles in a sample, provided that the effective number of scatterers in the probed volume is less than about five. We confirm these theoretical predictions experimentally, using suspensions of microspheres in water. The observed contrast ratios vary in value from the Rayleigh limit of 0.52 to in excess of 2, suggesting that the contrast ratio could be useful in optical coherence tomography, particularly when imaging in ultrahigh-resolution regimes.

Algorithms↗

Spatially resolved Fourier holographic light scattering angular spectroscopy.

We show for what is the first time to our knowledge that digital Fourier holography can be used to record spatially resolved angular light scattering spectra from microscopically structured samples. This is achieved in one or a few digital image captures over large millimeter-scale fields of view. Such spectra are a sensitive measure of microscopic morphology, with wide applications in biological and medical imaging. We demonstrate good agreement between results of experiment and Mie theory for the angular scattering spectra of microspheres in water extracted from local regions within reconstructed 2 x 1 millimeter image sets.

Equipment Design↗

Quantitative upper airway imaging with anatomic optical coherence tomography.

BACKGROUND: Measurements of upper airway size and shape are important in investigating the pathophysiology of obstructive sleep apnea (OSA) and in devising, applying, and determining the effectiveness of treatment modalities. We describe an endoscopic optical technique (anatomic optical coherence tomography, aOCT) that provides quantitative real-time imaging of the internal anatomy of the human upper airway. METHODS: Validation studies were performed by comparing aOCT- and computed tomography (CT)-derived measurements of cross-sectional area (CSA) in (1) conduits in a wax phantom and (2) the velo-, oro-, and hypopharynx during wakefulness in five volunteers. aOCT scanning was performed during sleep in one subject with OSA. RESULTS: aOCT generated images of pharyngeal shape and measurements of CSA and internal dimensions that were comparable to radiographic CT images. The mean difference between aOCT- and CT-derived measurements of CSA in (1) the wax phantom was 2.1 mm(2) with limits of agreement (2 SD) from -13.2 to 17.4 mm(2) and intraclass correlation coefficient of 0.99 (p < 0.001) and (2) the pharyngeal airway was 14.1 mm(2) with limits of agreement from -43.7 to 57.8 mm(2) and intraclass correlation coefficient of 0.89 (p < 0.001). aOCT generated quantitative images of changes in upper airway size and shape before, during, and after an apneic event in an individual with OSA. CONCLUSIONS: aOCT generates quantitative, real-time measurements of upper airway size and shape with minimal invasiveness, allowing study over lengthy periods during both sleep and wakefulness. These features should make it useful for study of upper airway behavior to investigate OSA pathophysiology and aid clinical management.

Adult↗

Bifocal optical coherenc refractometry of turbid media.

We propose and demonstrate a novel technique, which we term bifocal optical coherence refractometry, for the rapid determination of the refractive index of a turbid medium. The technique is based on the simultaneous creation of two closely spaced confocal gates in a sample. The optical path-length difference between the gates is measured by means of low-coherence interferometry and used to determine the refractive index. We present experimental results for the refractive indices of milk solutions and of human skin in vivo. As the axial scan rate determines the acquisition time, which is potentially of the order of tens of milliseconds, the technique has potential for in vivo refractive-index measurements of turbid biological media under dynamic conditions.

Animals↗

Delay and dispersion characteristics of a frequency-domain optical delay line for scanning interferometry.

The reflective frequency-domain optical delay line employing a diffraction grating, a lens, and a tiltable mirror has emerged as a device particularly suitable for interferometry and optical coherence tomography. The device is comprehensively described, both theoretically and experimentally, in the context of interferometry. The variations of phase and group delay produced by the device as well as its dispersive properties are described and demonstrated experimentally.

Interferometry↗

High-speed, high-sensitivity, gated surface profiling with closed-loop optical coherence topography.

We describe and experimentally demonstrate a novel (to our knowledge) surface profiling technique, for which we propose the term closed-loop optical coherence topography. This technique is a scanning beam, servo-locked variation of low-coherence interferometry. It allows for the sub-wavelength-resolution tracking of a weakly scattering macroscopic-scale surface, with the surface profile being directly output by the controlling electronics. The absence of significant real-time computational overhead makes the technique well suited to high-speed tracking. The use of a micrometer-scale coherence gate efficiently suppresses signals arising from structures not associated with the surface. These features make the technique particularly well suited to real-time surface profiling of in vivo, macroscopic biological surfaces.

Animals↗

High-speed gated surface profiling with closed-loop optical coherence topography.

The here presented work describes a surface profiling technique, for which the term closed-loop optical coherence topography (CLOCT) was proposed [1]. This technique is a scanning beam, servo-locked variation of low-coherence interferometry. It allows for the sub-wavelength-resolution tracking of a weakly scattering macroscopic-scale surface with the absence of significant real-time computational overhead and is thus particularly well suited to real-time surface profiling of in vivo, macroscopic biological surfaces.

Corneal Topography↗

Toward the discrimination of early melanoma from common and dysplastic nevus using fiber optic diffuse reflectance spectroscopy.

We describe a study of the discrimination of early melanoma from common and dysplastic nevus using fiber optic diffuse reflectance spectroscopy. Diffuse reflectance spectra in the wavelength range 550 to 1000 nm are obtained using 400-microm core multimode fibers arranged in a six-illumination-around-one-collection geometry with a single fiber-fiber spacing of 470 microm. Spectra are collected at specific locations on 120 pigmented lesions selected by clinicians as possible melanoma, including 64 histopathologically diagnosed as melanoma. These locations are carried through to the histopathological diagnosis, permitting a spatially localized comparison with the corresponding spectrum. The variations in spectra between groups of lesions with different diagnoses are examined and reduced to features suitable for discriminant analysis. A classifier distinguishing between benign and malignant lesions performs with sensitivity/specificity of between 6469% and 7278%. Classifiers between pairs of the group common nevus, dysplastic nevus, in situ melanoma, and invasive melanoma show better or similar performance than the benign/malignant classifier, and analysis provides evidence that different spectral features are needed for each pair of groups. This indicates that multiple discriminant systems are likely to be required to distinguish between melanoma and similar lesions.

Algorithms↗