Mass spectral determination of skeletal/cardiac actin isoform ratios in cardiac muscle.

Skeletal and cardiac muscle contains actin isoforms that vary by two juxtaposed amino acids and two amino acid substitutions (Met299Leu and Ser358Thr). This close sequence homology does not allow cardiac and skeletal actin isoforms to be resolved in traditional SDS-PAGE analysis as the molecular weights (Deltamass = 32 Da) are not significantly different and the pIs are identical (5.2). Although cardiac actin is the predominant form in cardiac muscle, there appears to be a specific skeletal/cardiac actin ratio in a normal heart that may vary in a compromised or diseased heart. In an effort to ascertain the validity of this hypothesis we developed a mass spectrometric technique to measure the ratio of skeletal to cardiac actin. The technique involves purification of muscle actin and subsequent liquid chromatography coupled with electrospray ionization Fourier transform ion cylcotron resonance (LC/FTICR-MS) mass spectrometry. A 7 Tesla FTICR mass spectrometer was utilized to compare skeletal/cardiac actin isoform ratios. Additionally, a new dual electrospray ionization source was employed to determine accurate masses of the alpha-skeletal and alpha-cardiac actins.

Actins↗

Determination of a correction to improve mass measurement accuracy of isotopically unresolved polymerase chain reaction amplicons by electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry.

The experimental determination of average mass by mass spectrometry is limited for large molecules due to the negative bias introduced by the natural distribution of isotopic abundances. This results in the measurement of the top-of-centroid (ToC) as opposed to the true centroid. We have developed a practical correction factor that is applied to the ToC measurement to largely remove the systematic bias introduced by nature. The correction factor is calculated easily using the average molecular mass (<100 kDa) of the analyte molecule and the full-width half maximum resolving power (<3,500) of the measurement. In addition, an approach to calculating resolving power is described that accurately predicts resolving power achievable for Fourier transform ion cyclotron resonance (FT-ICR) mass analysis of large molecules. A combination of internal calibration with a dual-electrospray source and application of the correction factor to average mass measurements improved the mass error from 192.5 to -35.0 ppm for a 44 kDa PCR amplicon.

Humans↗

Enzymatic strategies for the characterization of nucleic acids by electrospray ionization mass spectrometry.

Electrospray ionization mass spectrometry (ESI-MS) is a powerful technique used for the identification and characterization of DNA polymorphisms. Continual improvement in instrument design assures high mass measurement accuracy, sensitivity, and resolving power. This work describes an eclectic array of enzymatic strategies we have invoked in order to detect single-nucleotide polymorphisms by ESI-MS, although other applications may be envisioned. One strategy combines the use of two enzymes, exonuclease III and lambda exonuclease, to provide a ladder of single-stranded DNA fragments for straightforward sequence identification by mass spectrometry. A second strategy combines restriction enzymes to screen for polymorphisms present within specific amplicons. Finally, we describe the use of stable-isotope-labeled nucleotides for the determination of length and base composition of a PCR product.

Exodeoxyribonucleases↗

Advantages of Thermococcus kodakaraenis (KOD) DNA Polymerase for PCR-mass spectrometry based analyses.

The advantages of the thermostable DNA polymerase from Thermococcus kodakaraensis (KOD) are demonstrated for PCR amplification with subsequent detection by mass spectrometry. Commonly used DNA polymerases for PCR amplification include those from Thermus aquaticus (Taq) and Pyrococcus furiosus (Pfu). A 116 base-pair PCR product derived from a vWA locus was amplified by Taq, Pfu, or KOD DNA polymerase and compared by agarose gel electrophoresis and electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry (ESI-FTICR-MS). KOD DNA polymerase demonstrated a 2- to 3-fold increase in PCR product formation compared to Pfu or Taq, respectively, and generated blunt-ended PCR product which allows facile interpretation of the mass spectrum. Additionally, we demonstrate the advantage of using high magnetic fields to obtain unit resolution of the same 116 base pair (approximately 72 kDa) PCR product at high m/z.

DNA-Directed DNA Polymerase↗

Dual-micro-ESI source for precise mass determination on a quadrupole time-of-flight mass spectrometer for genomic and proteomic applications.

A universal dual-electrospray (ESI) source is demonstrated on a quadrupole orthogonal-accelerated time-of-flight mass spectrometer (Q-ToF-MS) for both genomic and proteomic applications. This facile source modification enables internal calibration for consistent mass measurements by a mainstream MS platform and requires no mixing of analyte and calibrant prior to ion formation. In this report, the dual-sprayer is demonstrated in the negative-ion mode for internal calibration of polymerase chain reaction (PCR) amplicons generated from synthetic and genomic templates as well as a proteolytic digest of a naturally phosphorylated protein. For all PCR amplicons, experimentally determined average mass measurements are well within the instrument specifications of better than 0.01%. For the proteolytic fragments of the phosphoprotein, average mass errors of the isotopically resolved peptides are better than 10 ppm.

Amino Acid Sequence↗

Gas-phase ion unimolecular dissociation for rapid phosphopeptide mapping by IRMPD in a Penning ion trap: an energetically favored process.

This communication discusses the efficient detection of the most important and common protein modification, phosphorylation, using ESI-FTICR-MS and IRMPD. Preliminary studies have demonstrated that within a complex protein digest, all phosphopeptides can be identified by a single IR laser irradiation event due to preferential dissociation of the modified peptides. This research demonstrates that the energy of activation for dissociation of the phosphopeptides is lower than that of the unmodified analogues providing the basis for the success of this technique. However, the P-O stretch (9.6-11 mum or 1042-909 cm-1) of this posttranslational modification is in direct resonance with the CO2 IR laser (10.6 mum or 943 cm-1) used for IRMPD. Therefore, the vibrational frequency of the phosphate moiety may be an additional factor in the rapid first-order decay of phosphopeptides. Based upon the energetics of dissociation discussed in this manuscript, IRMPD of ions in a Penning ion trap is an ideal platform for rapid phosphopeptide mapping.

Amino Acid Sequence↗

Solution composition and thermal denaturation for the production of single-stranded PCR amplicons: piperidine-induced destabilization of the DNA duplex?

Strategies to produce single-stranded PCR amplicons for detection by electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry (ESI-FTICR-MS) were investigated using modified electrospray solutions and by thermally denaturing the duplex structures with a resistively heated electrospray ionization source. A synthetic 20-mer oligonucleotide annealed to its complementary strand was used as a model system for initial experiments. Electrospray solutions were altered by varying the relative proportion of aqueous phase in efforts to induce destabilization of the double helix. When the electrospray solution contains a 25% aqueous content, the 20-mer oligonucleotide is detected in its double-stranded form. Increasing the proportion of aqueous phase in the electrospray solution to 60% destabilized the double helix, resulting in the detection of only single-stranded species. This strategy was extended to an 82-bp polymerase chain reaction (PCR) product derived from the human tyrosine hydroxylase gene (HUMTH01). In efforts to destabilize the 82-bp PCR product, electrospray solutions reaching 70% aqueous content were necessary to promote the detection of only single-stranded amplicons. Implementation of the resistively heated transfer line and an electrospray solution in which the oligonucleotide is on the threshold of duplex stability allowed for double-stranded and single-stranded species to be generated from the same ESI solutions at both ambient and elevated transfer line temperatures, respectively, without disruption of the electrospray process. The volatile base piperidine, present at 20 mM concentrations in the electrospray solution, was found to play a critical role in the formation of single-stranded species at the higher aqueous percentages and a duplex destabilization mechanism has been proposed.

Cyclotrons↗

Evaluation of sample preparation techniques for mass measurements of PCR products using ESI-FT-ICR mass spectrometry.

Elimination of PCR buffer components and alkali metal cations (i.e., Na+, K+) is of critical importance to allow for accurate mass measurements of PCR products for genotyping and sequencing applications. Ethanol precipitation followed by microdialysis has been repeatedly shown to efficiently desalt PCR products for analysis by mass spectrometry and is considered the gold standard. Alternative cleanup techniques that are compatible with automation are explored here with the intent of expanding the bottleneck that exists between the production of PCR products and analysis by electrospray ionization mass spectrometry (ESI-MS). Numerous combinations of approaches were evaluated that included PCR purification kits and alcohol precipitations. The data shown here support alternative approaches to an ethanol precipitation followed by microdialysis that have comparable desalting efficiency and can be utilized for cleanup of PCR products generated from single reactions.

2-Propanol↗

Evaluation of a cleavable stable isotope labeled synthetic peptide for absolute protein quantification using LC-MS/MS.

Protein cleavage coupled with isotope dilution mass spectrometry (PC-IDMS) has the potential to provide the absolute concentration of a specific protein, or multiple proteins, in complex mixtures. However, PC-IDMS differs from standard IDMS since the internal standard is a different molecule than the analyte at the start of the experiment, more specifically, the internal standard is a peptide and the analyte is a protein prior to cleavage. It is not until after the cleavage process that the stable isotope labeled synthetic peptide has the same physicochemical behavior as the peptide cleaved from the protein. The work presented here evaluates the use of tryptic cleavage sites incorporated into the internal standard synthetic peptide in an attempt to create an internal standard that has cleavage characteristics more similar to the protein being quantified. Results presented here suggest that an internal standard synthetic peptide incorporating internal cleavage sites does not improve the accuracy and precision of the values obtained when performing PC-IDMS.

Chromatography, Liquid↗

Evaluation of protein depletion methods for the analysis of total-, phospho- and glycoproteins in lumbar cerebrospinal fluid.

A proper sample preparation, in particular, abundant protein removal is crucial in the characterization of low-abundance proteins including those harboring post-translational modifications. In human cerebrospinal fluid (CSF), approximately 80% of proteins originate from serum, and removal of major proteins is necessary to study brain-derived proteins that are present at low concentrations for successful biomarker and therapeutic target discoveries for neurological disorders. In this study, phospho- and glycoprotein specific fluorescent stains and mass spectrometry were used to map proteins from CSF on two-dimensional gel electropherograms after immunoaffinity based protein removal. Two protein removal methods were evaluated: batch mode with avian IgY antibody microbeads using spin filters and HPLC multiple affinity removal column. Six abundant proteins were removed from CSF: human serum albumin (HSA), transferrin, IgG, IgA, IgM, and fibrinogen with batch mode, and HSA, transferrin, IgG, IgA, antitrypsin, and haptoglobin with column chromatography. 2D gels were compared after staining for phospho-, glyco- and total proteins. The column format removed the major proteins more effectively and approximately 50% more spots were visualized when compared to the 2D gel of CSF without protein depletion. After protein depletion, selected phospho- and glycoprotein spots were identified using mass spectrometry in addition to some of the spots that were not visualized previously in nondepleted CSF. Fifty proteins were identified from 66 spots, and among them, 12 proteins (24%) have not been annotated in previously published 2D gels.

Adult↗

Mapping sites of protein phosphorylation by mass spectrometry utilizing a chemical-enzymatic approach: characterization of products from alpha-S1 casein phosphopeptides.

A novel chemical-enzymatic approach was developed to facilitate identification of phosphorylation sites in isolated phosphoproteins. ESI-TOF mass spectrometry was used to characterize products from the chemical-enzymatic cleavage of specific phosphorylation sites in bovine alpha-S1 casein and synthetic phosphopeptides containing substitutions at a single phosphorylation site. Further refinements to this approach for identification of protein phosphorylation sites and its utility for the quantification of phosphopeptides by isotope-dilution mass spectrometry are presented.

Amino Acid Sequence↗

Absolute quantification of the model biomarker prostate-specific antigen in serum by LC-Ms/MS using protein cleavage and isotope dilution mass spectrometry.

Protein cleavage-isotope dilution mass spectrometry (PC-IDMS) can be used to quantify proteins, with an isotope-labeled analogue of the peptide fragment used as an internal standard. Here, we investigate use of a standard LC-MS/MS platform for quantifying a model biomarker directly from serum by this technique. We synthesized a peptide (IVGGWECEK) identical to the N-terminal tryptic fragment of PSA but with each glycine containing two 13C atoms and one 15N atom. PSA-free human serum was denatured with urea followed by the introduction of PSA standard and the stable isotope labeled internal standard peptide. The sample was then proteolyzed with trypsin and subjected to quantification using LC-MS/ MS on a triple quadrupole mass spectrometer. A linear least squares calibration curve made from five different concentrations of PSA added to serum and digested (each made in triplicate and randomly injected three times) had a mean slope of 0.973 (SE = 0.023), intercept of -0.003 (SE = 0.022), and R2 of 0.971. Recovery of calibrators ranged from 70 to 85% with a mean run-to-run CV of 13% and a mean within-run CV of 5.7%. PC-IDMS is a promising technique for quantifying proteins covering a broad range of applications from standardizing immunoassays to monitoring post-translational modifications to quantifying newly discovered biomarkers prior to the development and implementation of an immunoassay, just to name a few. Issues surrounding the application of PC-IDMS for the absolute quantification of proteins include selection of a proteolytic fragment for quantification that can be cleaved and isolated reproducibly over a broad dynamic range, stable isotope labeled synthetic peptide standards that give consistent results, and LC-MS/MS methods that provide adequate sensitivity and reproducibility without creating impractical analysis times. The results presented here show that absolute quantification can be performed on the model biomarker PSA introduced into denatured serum when analyzed by LC-MS/MS. However, concerns still exist regarding sensitivity compared to existing immunoassays as well as the reproducibility of PC-IDMS performed in different matrixes.

Humans↗

Quantitative protein expression analysis of CLL B cells from mutated and unmutated IgV(H) subgroups using acid-cleavable isotope-coded affinity tag reagents.

Relative protein expression levels were compared in leukemic B cells from two patients with chronic lymphocytic leukemia (CLL) having either mutated (M-CLL) or unmutated (UM-CLL) immunoglobulin variable heavy chain genes (IgV(H)). Cells were separated into cytosol and membrane protein fractions then labeled with acid-cleavable ICAT reagents (cICAT). Labeled proteins were digested with trypsin then subjected to SCX and affinity chromatography followed by LC-ESI-MS/MS analysis on a linear ion trap mass spectrometer. A total of 9 proteins from the cytosol fraction and 4 from the membrane fraction showed a 3-fold or greater difference between M-CLL and UM-CLL and a subset of these were examined by Western blot where results concurred with cICAT abundance ratios. The abundance of one of the proteins in particular, the mitochondrial membrane protein cytochrome c oxidase subunit COX G was examined in 6 M-CLL and 6 UM-CLL patients using western blot and results showed significantly greater levels (P < 0.001) in M-CLL patients vs UM-CLL patients. These results demonstrate that stable isotope labeling and mass spectrometry can complement 2D gel electrophoresis and gene microarray technologies for identifying putative and perhaps unique prognostic markers in CLL.

B-Lymphocytes↗

Identification of class II HLA-DRB1*03-bound measles virus peptides by 2D-liquid chromatography tandem mass spectrometry.

Two-dimensional liquid chromatography (2D-LC), combined with gas phase fractionation tandem mass spectrometry, was used to identify 13 naturally processed peptides originating from measles virus that were presented by HLA-DRB1*03 class II molecules. The peptides are from three of the six measles structural proteins: phosphoprotein, nucleocapsid, and hemagglutinin. These peptides provide an important first step toward understanding the mechanism of immune response to measles virus and development of a new generation of peptide-based vaccines.

Amino Acid Sequence↗

Discovery of ovarian cancer biomarkers in serum using NanoLC electrospray ionization TOF and FT-ICR mass spectrometry.

Treatment of cancer patients is greatly facilitated by detection of the cancer prior to metastasis. One of the obstacles to early cancer detection is the lack of availability of biomarkers with sufficient specificity. With modem differential proteomic techniques, the potential exists to identify high specificity cancer biomarkers. We have delineated a set of protocols for the isolation and identification of serum biomarkers for ovarian cancer that exist in the low molecular weight serum fraction. After isolation of the low molecular weight fraction by ultrafiltration, the potential biomarkers are separated by reversed phase nano liquid chromatography. Detection via TOF or FT-ICR yields a data set for each sample. We compared stage III/IV ovarian cancer serum with postmenopausal age-matched controls. Using bioinformatics tools developed at Mayo, we normalized each sample for intensity and chromatographic alignment. Normalized data sets are subsequently compared and potential biomarkers identified. Several candidate biomarkers were found. One of these contains the sequence of fibrinopeptide-A known to be elevated in many types of cancer including ovarian cancer. The protocols utilized will be examined and would be applicable to a wide variety of cancers or disease states.

Amino Acid Sequence↗