Search PubMed⌕ Search

Biomedical subjects

David C Cullen

Publications and source records attributed to David C Cullen.

5 recordsLinked to original sources

Preliminary investigation of proton and helium ion radiation effects on fluorescent dyes for use in astrobiology applications.

The Specific Molecular Identification of Life Experiment (SMILE) instrument (Sims et al. Planet. Space Science 2005, 53, 781-791) proposes to use specific molecular receptors for the detection of organic biomarkers on future astrobiology missions (e.g., to Mars). Such receptors will be used in assays with fluorescently labeled assay reagents. A key uncertainty of this approach is whether the fluorescent labels used in the system will survive exposure to levels of solar and galactic particle radiation encountered during a flight to Mars. Therefore, two fluorescent dyes (fluorescein and Alexa Fluor 633) have been exposed to low-energy proton and alpha radiation with total fluences comparable or exceeding that expected during an unshielded cruise to Mars. The results of these initial experiments are presented, which show that both dyes retain their fluorescent properties after irradiation. No significant alteration in the absorption and emission wavelengths or the quantum yields of the dyes with either radiation exposure was found. These results suggest other structurally similar fluorophores will likely retain their fluorescent properties after exposure to similar levels of proton and alpha radiation. However, more extensive radiation fluorophore testing is needed before their suitability for astrobiology missions to Mars can be fully confirmed.

Absorption↗

Optical interrogation of molecularly imprinted polymers and development of MIP sensors: a review.

This article reviews the progress and developments achieved in the past five years (2000-2005) in the application of optical analytical techniques to the evaluation of molecularly imprinted polymer (MIP) characteristics. The MIP binding efficiency, recognition processes and selectivity have been intensively studied by optical means due to the general high sensitivity and simplicity of the utilisation of optical techniques. In addition, recent progress in the covalent linkage of MIPs to optical transducers has allowed for the realisation of highly efficient and robust optical MIP-based molecular recognition sensors. The review provides insight into the various approaches to the optical interrogation of MIPs, and is organised according to the type of optical technique employed (fluorescence, UV/Vis and infrared spectroscopy, surface plasmon resonance, chemiluminescence, refractive interference spectroscopy and Raman scattering) and the detailed strategies applied. The review also covers the recent progress achieved in the area of optical sensors based on MIPs.

Biosensing Techniques↗

A cell array biosensor for environmental toxicity analysis.

In this study, a cell-based array technology that uses recombinant bioluminescent bacteria to detect and classify environmental toxicity has been implemented to develop two biosensor arrays, i.e., a chip and a plate array. Twenty recombinant bioluminescent bacteria, having different promoters fused with the bacterial lux genes, were immobilized within LB-agar. About 2 microl of the cell-agar mixture was deposited into the wells of either a cell chip or a 384-well plate. The bioluminescence (BL) from the cell arrays was measured with the use of highly sensitive cooled CCD camera that measured the bioluminescent signal from the immobilized cells and then quantified the pixel density using image analysis software. The responses from the cell arrays were characterized using three chemicals that cause either superoxide damage (paraquat), DNA damage (mitomycin C) or protein/membrane damage (salicylic acid). The responses were found to be dependent upon the promoter fused upstream of the lux operon within each strain. Therefore, a sample's toxicity can be analyzed and classified through the changes in the BL expression from each well. Moreover, a time of only 2 h was needed for analysis, making either of these arrays a fast, portable and economical high-throughput biosensor system for detecting environmental toxicities.

Arabidopsis Proteins↗

Development of a common biosensor format for an enzyme based biosensor array to monitor fruit quality.

Individual enzyme-based biosensors involving three-electrode systems were developed for the detection of analytes comprising markers of the stage of maturity and quality in selected fruits of economic importance to tropical countries. Importantly, a common fabrication format has been developed to simplify manufacture and allow future integration of the individual sensors into a single multi-sensor array. Specifically, sensors for beta-D-glucose, total D-glucose, sucrose and ascorbic acid have been developed. Pectin, a natural polysaccharide present in plant cells, was used as a novel matrix to enhance enzyme entrapment and stabilisation in the sensors. Except for ascorbic acid, all the sensors function via the detection of enzymatically generated H2O2 at rhodinised carbon electrodes. Since ascorbic acid is electrochemically active at the working potential chosen (+350 mV vs. Ag/AgCl), it was measured directly. Enzyme sensors demonstrated expected response with respect to their substrates, typically 0-0.8 microA/20 mm2 electrode area response over analyte ranges of 0-7 mM. Interferences related to electrochemically active compounds present in fruits under study were significantly reduced by inclusion of a suitable cellulose acetate (CA) membrane or by enzymatic inactivation with ascorbate oxidase. Initial development was carried out into production of biosensor arrays. CA membranes were used to improve the linear range of the sensors, producing up to a fivefold improvement in the detection range compared to sensors without an additional diffusion barrier.

Ascorbic Acid↗

Monitoring and classification of PAH toxicity using an immobilized bioluminescent bacteria.

An immobilized recombinant bioluminescent Escherichia coli strain, harboring a lac::luxCDABE fused plasmid, which shows lower bioluminescence levels when cellular metabolism is inhibited, was used to monitor the cellular toxicity of polycyclic aromatic hydrocarbons (PAHs). PAHs, classified as pericondensed (PCPAHs) or catacondensed (CCPAHs) according to their molecular structures, were differentiable according to the response of this biosensor. Only CCPAHs were found to cause cellular toxicity, resulting in a dose-dependent decrease in the bioluminescent output. The induction of cellular toxicity by CCPAHs and PCPAHs was compared with acute toxicity predictions obtained using the quantitative structure-activity relationship (QSAR) model. A good relationship was obtained between the toxicities determined with the bioluminescent response of the immobilized bacterium GC2 and the QSAR model. It was also found that the present study offers a new method of predicting the cellular toxicities of CCPAHs or PCPAHs using this biosensor.

Biosensing Techniques↗