David A Jaffray

Publications and source records attributed to David A Jaffray.

24 records · Page 2Linked to original sources

On-line aSi portal imaging of implanted fiducial markers for the reduction of interfraction error during conformal radiotherapy of prostate carcinoma.

PURPOSE: An on-line system to ensure accuracy of daily setup and therapy of the prostate has been implemented with no equipment modification required. We report results and accuracy of patient setup using this system. METHODS AND MATERIALS: Radiopaque fiducial markers were implanted into the prostate before radiation therapy. Lateral digitally reconstructed radiographs (DRRs) were obtained from planning CT data. Before each treatment fraction, a lateral amorphous silicon (aSi) portal image was acquired and the position of the fiducial markers was compared to the DRRs using chamfer matching. Couch translation only was used to account for marker position displacements, followed by a second lateral portal image to verify isocenter position. Residual displacement data for the aSi and previous portal film systems were compared. RESULTS: This analysis includes a total of 239 portal images during treatment in 17 patients. Initial prostate center of mass (COM) displacements in the superior, inferior, anterior, and posterior directions were a maximum of 7 mm, 9 mm, 10 mm and 11 mm respectively. After identification and correction, prostate COM displacements were <3 mm in all directions. The therapists found it simple to match markers 88% of the time using this system. Treatment delivery times were in the order of 9 min for patients requiring isocenter adjustment and 6 min for those who did not. CONCLUSIONS: This system is technically possible to implement and use as part of an on-line correction protocol and does not require a longer than standard daily appointment time at our center with the current action limit of 3 mm. The system is commercially available and is more efficient and user-friendly than portal film analysis. It provides the opportunity to identify and accommodate interfraction organ motion and may also permit the use of smaller margins during conformal prostate radiotherapy. Further integration of the system such as remote table control would improve efficiency.

Humans↗

Online ultrasound image guidance for radiotherapy of prostate cancer: impact of image acquisition on prostate displacement.

AIM: Numerous studies reported the use of ultrasound image-guidance system to assess and correct patient setup during radiotherapy for prostate cancer. We conducted a study to demonstrate and quantify prostate displacement resulting from pressure of the probe on the abdomen during transabdominal ultrasound image acquisition for prostate localization. MATERIAL AND METHODS: Ten healthy volunteers were asked to undergo one imaging procedure. The procedure was performed in a condition that simulates the localization of prostate during online ultrasound guidance. A 3D ultrasound machine was used. The procedure started with the placement of the probe on the abdomen above the pubis symphysis. The probe was tilted in a caudal and posterior direction until the prostate and seminal vesicle were visualized. The probe was then fixed with a rigid arm, which maintained the probe in a static position during image acquisition. The probe was then moved, in a short time, stepwise toward the prostate, acquiring images at each step. The prostate and seminal vesicles were identified and selected in all planes. The first 3D volume was used as reference 1, to which all other scans were matched using a gray value matching algorithm. RESULTS: Prostate motion was quantified as a 3D translation relative to the patient coordinate system. The resulting translations represented the amount of prostate movement as a function of probe displacement. Between 7 and 11 images were obtained per volunteer, with a maximal probe displacement ranging between 3 and 6 cm. Prostate displacement was measured in all volunteers for all the probe steps and in all directions. The largest displacements occurred in the posterior direction in all volunteers. The absolute prostate motion was less than 5 mm in 100% of the volunteers after 1 cm of probe displacement, in 80% after 1.5 cm, in 40% after 2 cm, in 10% after 2.5 cm, and 0% after 3 cm. To achieved a good-quality ultrasound images, the probe requires an average displacement of 1.2 cm, and this results in an average prostate displacement of 3.1 mm. No correlations were observed between prostate motion and prostate-probe distance or bladder size. CONCLUSION: Probe pressure during ultrasound image acquisition causes prostate displacement, which is correlated to the amount of probe displacement from initial contact. The induced uncertainty associated with this process needs to be carefully evaluated to determine a safe margin to be employed during online ultrasound image-guided radiotherapy of the prostate.

Adult↗

Characteristics and performance of a micro-MOSFET: an "imageable" dosimeter for image-guided radiotherapy.

The performance and characteristics of a miniature metal oxide semiconductor field effect transistor (micro-MOSFET) detector was investigated for its potential application to integral system tests for image-guided radiotherapy. In particular, the position of peak response to a slit of radiation was determined for the three principal axes to define the co-ordinates for the center of the active volume of the detector. This was compared to the radiographically determined center of the micro-MOSFET visible using cone-beam CT. Additionally, the angular sensitivity of the micro-MOSFET was measured. The micro-MOSFETs are clearly visible on the cone-beam CT images, and produce no artifacts. The center of the active volume of the micro-MOSFET aligned with the center of the visible micro-MOSFET on the cone-beam CT images for the x and y axes to within 0.20 mm and 0.15 mm, respectively. In z, the long axis of the detector, the peak response was found to be 0.79 mm from the tip of the visible micro-MOSFET. Repeat experiments verified that the position of the peak response of the micro-MOSFET was reproducible. The micro-MOSFET response for 360 degrees of rotation in the axial plane to the micro-MOSFET was +/-2%, consistent with values quoted by the manufacturer. The location of the active volume of the micro-MOSFETs under investigation can be determined from the centroid of the visible micro-MOSFET on cone-beam CT images. The CT centroid position corresponds closely to the center of the detector response to radiation. The ability to use the cone-beam CT to locate the active volume to within 0.20 mm allows their use in an integral system test for the imaging of and dose delivery to a phantom containing an array of micro-MOSFETs. The small angular sensitivity allows the investigation of noncoplanar beams.

Calibration↗

Development of an integral system test for image-guided radiotherapy.

An integral system test was developed to determine the precision and accuracy of an image-guided radiotherapy system involving an x-ray volumetric imaging device mounted onto the gantry of a medical linear accelerator. The test was designed to interrogate the system components as a whole without deconstructing the individual sources of error. The integral system test was based on the imaging of an unambiguous stationary object in the treatment position and so took no account of patient related errors. An array of micromosfets interspersed within slices of a tissue equivalent phantom was developed as an imaging test object. It has previously been demonstrated that micromosfets have a very small active volume, are clearly visible on CT images, and produce no significant artifacts. In addition, the active volume of the micromosfets can be accurately inferred radiographically via the use of x-ray volumetric imaging. X-ray volumetric imaging was performed with the object in the treatment position, then reconstructed and transferred to a treatment planning system. With the phantom remaining undisturbed in the treatment position a series of treatment fields were designed to produce a series of fields with the leaf edge sweeping across active volume of the micromosfets. The fields were delivered with a micro-MLC to dosimetrically verify the position of the mosfets and compare with dose values produced by the treatment planning system. It was demonstrated that the systematic gantry flex could be accounted for by the imaging and delivery systems. For the delivery system small changes in leaf positions of the micro-MLC were required to account for gantry flex. The position of the micromosfets determined by the 50% dose position was on average (0.15+/-0.13) mm away from the position determined radiographically for the x and y axes, and (1.0+/-0.14) mm for the z axis. This implies that a margin of approximately 0.2 mm in the axial plane and 1.0 mm in the superior-inferior plane would be required at the delineation stage to ensure coverage of a tumor volume to account purely for imprecision in the image-guided radiotherapy system. The integral system test demonstrated that the image-guided radiotherapy system is capable, in the absence of patient motion, of imaging an object in the treatment position and delivering dose to that object with submillimeter accuracy.

Equipment Design↗

Optical-CT gel-dosimetry I: basic investigations.

Comprehensive verification of the intricate dose distributions associated with advanced radiation treatments is now an immediate and substantial problem. The task is challenging using traditional dosimeters because of restrictions to point measurements (ion chambers, diodes, TLD, etc.) or planar measurements (film). In essence, rapid advances in the technology to deliver radiation treatments have not been paralleled by corresponding advances in the ability to verify these treatments. A potential solution has emerged in the form of water equivalent three dimensional (3D) gel-dosimetry. In this paper we present basic characterization and performance studies of a prototype optical-CT scanning system developed in our laboratory. An analysis of the potential role or scope of gel dosimetry, in relation to other dosimeters, and to verification across the spectrum of therapeutic techniques is also given. The characterization studies enabled the determination of nominal operating conditions for optical-CT scanning. "Finger" phantoms are introduced as a powerful and flexible tool for the investigation of optical-CT performance. The modulation-transfer function (MTF) of the system is determined to be better than 10% out to 1 mm(-1), confirming sub-mm imaging ability. System performance is demonstrated by the acquisition of a 1 x 1 x 1 mm3 dataset through the dose distribution delivered by an x-ray lens that focuses x rays in the energy range 40-80 KeV. This 3D measurement would be extremely difficult to achieve with other dosimetry techniques and highlights some of the strengths of gel dosimetry. Finally, an optical Monte Carlo model is introduced and shown to have potential to model light transport through gel-dosimetry systems, and to provide a tool for the study and optimization of optical-CT gel dosimetry. The model utilizes Mie scattering theory and requires knowledge of the variation of the particle size distribution with dose. The latter was determined here using the technique of dynamic-light-scattering.

Algorithms↗

Flat-panel cone-beam computed tomography for image-guided radiation therapy.

PURPOSE: Geometric uncertainties in the process of radiation planning and delivery constrain dose escalation and induce normal tissue complications. An imaging system has been developed to generate high-resolution, soft-tissue images of the patient at the time of treatment for the purpose of guiding therapy and reducing such uncertainties. The performance of the imaging system is evaluated and the application to image-guided radiation therapy is discussed. METHODS AND MATERIALS: A kilovoltage imaging system capable of radiography, fluoroscopy, and cone-beam computed tomography (CT) has been integrated with a medical linear accelerator. Kilovoltage X-rays are generated by a conventional X-ray tube mounted on a retractable arm at 90 degrees to the treatment source. A 41 x 41 cm(2) flat-panel X-ray detector is mounted opposite the kV tube. The entire imaging system operates under computer control, with a single application providing calibration, image acquisition, processing, and cone-beam CT reconstruction. Cone-beam CT imaging involves acquiring multiple kV radiographs as the gantry rotates through 360 degrees of rotation. A filtered back-projection algorithm is employed to reconstruct the volumetric images. Geometric nonidealities in the rotation of the gantry system are measured and corrected during reconstruction. Qualitative evaluation of imaging performance is performed using an anthropomorphic head phantom and a coronal contrast phantom. The influence of geometric nonidealities is examined. RESULTS: Images of the head phantom were acquired and illustrate the submillimeter spatial resolution that is achieved with the cone-beam approach. High-resolution sagittal and coronal views demonstrate nearly isotropic spatial resolution. Flex corrections on the order of 0.2 cm were required to compensate gravity-induced flex in the support arms of the source and detector, as well as slight axial movements of the entire gantry structure. Images reconstructed without flex correction suffered from loss of detail, misregistration, and streak artifacts. Reconstructions of the contrast phantom demonstrate the soft-tissue imaging capability of the system. A contrast of 47 Hounsfield units was easily detected in a 0.1-cm-thick reconstruction for an imaging exposure of 1.2 R (in-air, in absence of phantom). The comparison with a conventional CT scan of the phantom further demonstrates the spatial resolution advantages of the cone-beam CT approach. CONCLUSIONS: A kV cone-beam CT imaging system based on a large-area, flat-panel detector has been successfully adapted to a medical linear accelerator. The system is capable of producing images of soft tissue with excellent spatial resolution at acceptable imaging doses. Integration of this technology with the medical accelerator will result in an ideal platform for high-precision, image-guided radiation therapy.

Algorithms↗