Search PubMed⌕ Search

Biomedical subjects

David A Boas

Publications and source records attributed to David A Boas.

47 records · Page 3Linked to original sources

Frontal lobe activation during object permanence: data from near-infrared spectroscopy.

The ability to create and hold a mental schema of an object is one of the milestones in cognitive development. Developmental scientists have named the behavioral manifestation of this competence object permanence. Convergent evidence indicates that frontal lobe maturation plays a critical role in the display of object permanence, but methodological and ethical constrains have made it difficult to collect neurophysiological evidence from awake, behaving infants. Near-infrared spectroscopy provides a noninvasive assessment of changes in oxy- and deoxyhemoglobin and total hemoglobin concentration within a prescribed region. The evidence described in this report reveals that the emergence of object permanence is related to an increase in hemoglobin concentration in frontal cortex.

Female↗

Intrinsic brain activity triggers trigeminal meningeal afferents in a migraine model.

Although the trigeminal nerve innervates the meninges and participates in the genesis of migraine headaches, triggering mechanisms remain controversial and poorly understood. Here we establish a link between migraine aura and headache by demonstrating that cortical spreading depression, implicated in migraine visual aura, activates trigeminovascular afferents and evokes a series of cortical meningeal and brainstem events consistent with the development of headache. Cortical spreading depression caused long-lasting blood-flow enhancement selectively within the middle meningeal artery dependent upon trigeminal and parasympathetic activation, and plasma protein leakage within the dura mater in part by a neurokinin-1-receptor mechanism. Our findings provide a neural mechanism by which extracerebral cephalic blood flow couples to brain events; this mechanism explains vasodilation during headache and links intense neurometabolic brain activity with the transmission of headache pain by the trigeminal nerve.

Brain↗

Near-infrared spiroximetry: noninvasive measurements of venous saturation in piglets and human subjects.

We present a noninvasive method to measure the venous oxygen saturation (Sv(O(2))) in tissues using near-infrared spectroscopy (NIRS). This method is based on the respiration-induced oscillations of the near-infrared absorption in tissues, and we call it spiroximetry (the prefix spiro means respiration). We have tested this method in three piglets (hind leg) and in eight human subjects (vastus medialis and vastus lateralis muscles). In the piglet study, we compared our NIRS measurements of the Sv(O(2)) (Sv(O(2))-NIRS(resp)) with the Sv(O(2)) of blood samples. Sv(O(2))-NIRS(resp) and Sv(O(2)) of blood samples agreed well over the whole range of Sv(O(2)) considered (20-95%). The two measurements showed an average difference of 1.0% and a standard deviation of the difference of 5.8%. In the human study, we found a good agreement between Sv(O(2))-NIRS(resp) and the Sv(O(2)) values measured with the NIRS venous occlusion method. Finally, in a preliminary test involving muscle exercise, Sv(O(2))-NIRS(resp) showed an expected postexercise decrease from the initial baseline value and a subsequent recovery to baseline.

Adult↗

A quantitative comparison of simultaneous BOLD fMRI and NIRS recordings during functional brain activation.

Near-infrared spectroscopy (NIRS) has been used to noninvasively monitor adult human brain function in a wide variety of tasks. While rough spatial correspondences with maps generated from functional magnetic resonance imaging (fMRI) have been found in such experiments, the amplitude correspondences between the two recording modalities have not been fully characterized. To do so, we simultaneously acquired NIRS and blood-oxygenation level-dependent (BOLD) fMRI data and compared Delta(1/BOLD) (approximately R(2)(*)) to changes in oxyhemoglobin, deoxyhemoglobin, and total hemoglobin concentrations derived from the NIRS data from subjects performing a simple motor task. We expected the correlation with deoxyhemoglobin to be strongest, due to the causal relation between changes in deoxyhemoglobin concentrations and BOLD signal. Instead we found highly variable correlations, suggesting the need to account for individual subject differences in our NIRS calculations. We argue that the variability resulted from systematic errors associated with each of the signals, including: (1) partial volume errors due to focal concentration changes, (2) wavelength dependence of this partial volume effect, (3) tissue model errors, and (4) possible spatial incongruence between oxy- and deoxyhemoglobin concentration changes. After such effects were accounted for, strong correlations were found between fMRI changes and all optical measures, with oxyhemoglobin providing the strongest correlation. Importantly, this finding held even when including scalp, skull, and inactive brain tissue in the average BOLD signal. This may reflect, at least in part, the superior contrast-to-noise ratio for oxyhemoglobin relative to deoxyhemoglobin (from optical measurements), rather than physiology related to BOLD signal interpretation.

Adult↗

Using near-infrared spectroscopy to assess neural activation during object processing in infants.

The capacity to represent the world in terms of numerically distinct objects (i.e., object individuation) is a milestone in early cognitive development and forms the foundation for more complex thought and behavior. Over the past 10 to 15 yr, infant researchers have expended a great deal of effort to identify the origins and development of this capacity. In contrast, relatively little is known about the neural mechanisms that underlie the ability to individuate objects, in large part because there are a limited number of noninvasive techniques available to measure brain functioning in human infants. Recent research suggests that near-IR spectroscopy (NIRS), an optical imaging technique that uses relative changes in total hemoglobin concentration and oxygenation as an indicator of neural activation, may be a viable procedure for assessing the relation between object processing and brain function in human infants. We examine the extent to which increased neural activation, as measured by NIRS, could be observed in two neural areas known to be involved in object processing, the primary visual cortex and the inferior temporal cortex, during an object processing task. Infants aged 6.5 months are presented with a visual event in which two featurally distinct objects emerge successively to opposite sides of an occluder and neuroimaging data are collected. As predicted, increased neural activation is observed in both the primary visual and inferior cortex during the visual event, suggesting that these neural areas support object processing in the young infant. The outcome has important implications for research in cognitive development, developmental neuroscience, and optical imaging.

Cerebrovascular Circulation↗

Eigenvector-based spatial filtering for reduction of physiological interference in diffuse optical imaging.

Diffuse optical imaging is an effective technique for noninvasive functional brain imaging. However, the measurements respond to systemic hemodynamic fluctuations caused by the cardiac cycle, respiration, and blood pressure, which may obscure or overwhelm the desired stimulus-evoked response. Previous work on this problem employed temporal filtering, estimation of systemic effects from background pixels, or modeling of interference signals with predefined basis functions, with some success. However, weak signals are still lost in the interference, and other complementary methods are desirable. We use the spatial behavior of measured baseline signals to identify the interference subspaces. We then project signals components in this subspace out of the stimulation data. In doing so, we assume that systemic interference components will be more global spatially, with higher energy, than the stimulus-evoked signals of interest. Thus, the eigenvectors corresponding to the largest eigenvalues of an appropriate correlation matrix form the basis for an interference subspace. By projecting the data onto the orthogonal nullspace of these eigenvectors, we can obtain more localized response, as reflected in improved contrast-to-noise ratio and correlation coefficient maps.

Artifacts↗

Improved sensitivity to cerebral hemodynamics during brain activation with a time-gated optical system: analytical model and experimental validation.

Time domain (TD) diffuse optical measurement systems are being applied to neuroimaging, where they can detect hemodynamics changes associated with cerebral activity. We show that TD systems can provide better depth sensitivity than the more traditional continuous wave (CW) systems by gating late photons, which carry information about deep layers of the brain, and rejecting early light, which is sensitive to the superficial physiological signal clutter. We use an analytical model to estimate the contrast due to an activated region of the brain, the instrumental noise of the systems, and the background signal resulting from superficial physiological signal clutter. We study the contrast-to-noise ratio and the contrast-to-background ratio as a function of the activation depth and of the source-detector separation. We then present experimental results obtained with a time-gated instrument on the motor cortex during finger-tapping exercises. Both the model and the experimental results show a similar contrast-to-noise ratio for CW and TD, but that estimation of the contrast is experimentally limited by background fluctuations and that a better contrast-to-background ratio is obtained in the TD case. Finally, we use the time-gated measurements to resolve in depth the brain activation during the motor stimulus.

Artifacts↗

Coregistered tomographic x-ray and optical breast imaging: initial results.

We describe what is, to the best of our knowledge, the first pilot study of coregistered tomographic x-ray and optical breast imaging. The purpose of this pilot study is to develop both hardware and data processing algorithms for a multimodality imaging method that provides information that neither x-ray nor diffuse optical tomography (DOT) can provide alone. We present in detail the instrumentation and algorithms developed for this multimodality imaging. We also present results from our initial pilot clinical tests. These results demonstrate that strictly coregistered x-ray and optical images enable a detailed comparison of the two images. This comparison will ultimately lead to a better understanding of the relationship between the functional contrast afforded by optical imaging and the structural contrast provided by x-ray imaging.

Aged↗

Time-gated optical system for depth-resolved functional brain imaging.

We present a time-domain optical system for functional imaging of the adult head. We first describe the instrument, which is based on a Ti:Sapphire pulsed laser (wavelength 750-850 nm) and an intensified CCD camera enabling parallel detection of multiple fibers. We characterize the system in terms of sensitivity and signal-to-noise ratio, instrument response function, cross-talk, stability, and reproducibility. We then describe two applications of the instrument: the characterization of baseline optical properties of homogeneous scattering media, and functional brain imaging. For the second application, we developed a two-part probe consisting in two squares of 4 x 4 sources and 3 x 3 detectors. The laser source is time-multiplexed to define 4 states of 8 sources that can be turned on during the same camera frame while minimizing cross-talk. On the detection side, we use for each detector 7 fibers of different lengths creating an optical delay, and enabling simultaneous detection in 7 windows (by steps of 500 ps) for each detector. This multiple window detection allows depth sensitivity. The imaging probe was tested on dynamic phantoms and a preliminary result on an adult performing a motor task shows discrimination between superficial and cortical responses to the stimulus on both hemispheres.

Adult↗

Diffuse optical imaging of the whole head.

Near-Infrared Spectroscopy (NIRS) and diffuse optical imaging (DOI) are increasingly used to detect hemodynamic changes in the cerebral cortex induced by brain activity. Until recently, the small number of optodes in NIRS instruments has hampered measurement of optical signals from diverse brain regions. Our new DOI system has 32 detectors and 32 sources; by arranging them in a specific pattern, we can cover most of the adult head. With the increased number of optodes, we can collect optical data from prefrontal, sensorimotor, and visual cortices in both hemispheres simultaneously. We describe the system and report system characterization measurements on phantoms as well as on human subjects at rest and during visual, motor, and cognitive stimulation. Taking advantage of the system's larger number of sources and detectors, we explored the spatiotemporal patterns of physiological signals during rest. These physiological signals, arising from cardiac, respiratory, and blood-pressure modulations, interfere with measurement of the hemodynamic response to brain stimulation. Whole-head optical measurements, in addition to providing maps of multiple brain regions' responses to brain activation, will enable better understandings of the physiological signals, ultimately leading to better signal processing algorithms to distinguish physiological signal clutter from brain activation signals.

Adult↗

Quantitative spatial comparison of diffuse optical imaging with blood oxygen level-dependent and arterial spin labeling-based functional magnetic resonance imaging.

Akin to functional magnetic resonance imaging (fMRI), diffuse optical imaging (DOI) is a noninvasive method for measuring localized changes in hemoglobin levels within the brain. When combined with fMRI methods, multimodality approaches could offer an integrated perspective on the biophysics, anatomy, and physiology underlying each of the imaging modalities. Vital to the correct interpretation of such studies, control experiments to test the consistency of both modalities must be performed. Here, we compare DOI with blood oxygen level-dependent (BOLD) and arterial spin labeling fMRI-based methods in order to explore the spatial agreement of the response amplitudes recorded by these two methods. Rather than creating optical images by regularized, tomographic reconstructions, we project the fMRI image into optical measurement space using the optical forward problem. We report statistically better spatial correlation between the fMRI-BOLD response and the optically measured deoxyhemoglobin (R=0.71, p=1x10(-7)) than between the BOLD and oxyhemoglobin or total hemoglobin measures (R=0.38, p=0.04|0.37, p=0.05, respectively). Similarly, we find that the correlation between the ASL measured blood flow and optically measured total and oxyhemoglobin is stronger (R=0.73, p=5x10(-6) and R=0.71, p=9x10(-6), respectively) than the flow to deoxyhemoglobin spatial correlation (R=0.26, p=0.10).

Adult↗