Search PubMed⌕ Search

Biomedical subjects

Daniel T Chiu

Publications and source records attributed to Daniel T Chiu.

32 records · Page 2Linked to original sources

Controlled rotation of biological micro- and nano-particles in microvortices.

Micrometer-sized re-circulating flows generated in a microfluidic system are used to drive the controlled rotation of biological particles of both micro- and nano-meter scale dimensions. This technique is independent of the intrinsic nature of the particle, and possesses the potential to rotate particles at high rates. We demonstrate in such microvortices the orientation control of single DNA molecules, and the axial rotation of biological cells in which the cellular contents were visibly affected by rotation.

Animals↗

Concentrating solutes and nanoparticles within individual aqueous microdroplets.

This paper describes a method to concentrate solutes and colloidal entities, from small ions and molecules to proteins and nanoparticles, within individual aqueous microdroplets in oil. The mechanism lies in the entrapment of the solutes within an aqueous microdroplet, while the water molecules from the droplet slowly dissolve into the organic phase. Because the rate of change in concentration scales as the fifth power of the surface-area-to-volume ratio of the droplet, this phenomenon is prominent mostly in the micrometer-length scale. This paper presents measurements that quantify the degree of solute entrapment within the microdroplet and further describes the dynamics of droplet shrinkage and the factors that influence the rate of shrinkage. In addition, this paper explains why this concentration effect does not occur for certain organic microdroplets in aqueous solutions.

Journal Article↗

Parametric investigation on the effect of channel topologies on electrophoretic separations.

This paper presents a systematic study that illustrates the importance of the topologies of microchannels on electrokinetically based separation. Using theoretical and numerical analyses, we designed and showed that topologies that significantly increased the surface-to-volume ratio of the channel can provide dramatic improvement in the ability of the channel both to dissipate the heat generated by Joule heating and to reduce the axial dispersion associated with the siphoning effect. The incremental benefit and tradeoff of geometric complexity was also evaluated. The improvement offered by topographically patterned channels, such as finned structures, is especially pertinent in the development of preparative or semi-preparative scale electrokinetically driven separations, such as capillary electrophoresis and capillary electrochromatography, in which large cross sections of channels are required to achieve the needed volumetric throughput.

Electrophoresis↗

High-power blue/UV light-emitting diodes as excitation sources for sensitive detection.

With advances in III-V nitride manufacturing processes, high-power light-emitting diode (LED) chips in the blue and UV wavelengths are now commercially available at reasonable cost and can be used as excitation sources in optical sensing. We describe the use of these high-power blue and UV LEDs for sensitive fluorescence detection, including chip-based flow cytometry, capillary electrophoresis (CE), and single-molecule imaging. By using a blue LED with a focusable power of approximately 40 mW as the excitation source for fluorescent beads, we demonstrate a simple chip-based bead sorter capable of enriching the concentration of green fluorescent beads from 63% to 95%. In CE experiments, we show that a mixture of analyte solution containing 30 nM 6-carboxyrhodamine 6G and 10 nM fluorescein can be separated and detected with excellent signal-to-noise ratio (approximately 17 for 10 nM fluorescein) using the collimated emission from a blue LED; the estimated mass detection limit was approximately 200 zmol for fluorescein. We also demonstrated ultrasensitive fluorescence imaging of single rhodamine 123 molecules and individual lambda-DNA molecules. At a small fraction of the cost of an Ar+ laser, high-power blue and UV LEDs are effective alternatives for lasers and arc lamps in fluorescence applications that demand portability, low cost, and convenience.

Cells↗

A microfluidic model for single-cell capillary obstruction by Plasmodium falciparum-infected erythrocytes.

Severe malaria by Plasmodium falciparum is a potentially fatal disease, frequently unresponsive to even the most aggressive treatments. Host organ failure is associated with acquired rigidity of infected red blood cells and capillary blockage. In vitro techniques have played an important role in modeling cell deformability. Although, historically they have either been applied to bulk cell populations or to measure single physical parameters of individual cells. In this article, we demonstrate the unique abilities and benefits of elastomeric microchannels to characterize complex behaviors of single cells, under flow, in multicellular capillary blockages. Channels of 8-, 6-, 4-, and 2-microm widths were readily traversed by the 8 microm-wide, highly elastic, uninfected red blood cells, as well as by infected cells in the early ring stages. Trophozoite stages failed to freely traverse 2- to 4-microm channels; some that passed through the 4-microm channels emerged from constricted space with deformations whose shape-recovery could be observed in real time. In 2-microm channels, trophozoites mimicked "pitting," a normal process in the body where spleen beds remove parasites without destroying the red cell. Schizont forms failed to traverse even 6-microm channels and rapidly formed a capillary blockage. Interestingly, individual uninfected red blood cells readily squeezed through the blockages formed by immobile schizonts in a 6-microm capillary. The last observation can explain the high parasitemia in a growing capillary blockage and the well known benefits of early blood transfusion in severe malaria.

Animals↗

Microfluidic systems: high radial acceleration in microvortices.

Microfluidic systems can conveniently be used for rapid analysis of biological samples. Here we describe a single re-circulating flow, or microvortex, that can generate a maximum fluid rotational velocity of up to 12 m s(-1) and a corresponding radial acceleration in excess of 10(6)g. Such microvortices may be exploited in centrifugal microdevices to investigate the effects of high radial acceleration on biological and chemical processes.

Journal Article↗

Fabrication of thermoset polyester microfluidic devices and embossing masters using rapid prototyped polydimethylsiloxane molds.

Plastics are increasingly being used for the fabrication of Lab-on-a-Chip devices due to the variety of beneficial material properties, affordable cost, and straightforward fabrication methods available from a range of different types of plastics. Rapid prototyping of polydimethylsiloxane (PDMS) devices has become a well-known process for the quick and easy fabrication of microfluidic devices in the research laboratory; however, PDMS is not always an appropriate material for every application. This paper describes the fabrication of thermoset polyester microfluidic devices and masters for hot embossing using replica molding techniques. Rapid prototyped PDMS molds are convienently used for the production of non-PDMS polymeric devices. The recessed features in the cast polyester can be bonded to a second polyester piece to form an enclosed microchannel. Thermoset polyester can withstand moderate amounts of pressure and elevated temperature; therefore, the cast polyester piece also can be used as a master for embossing polymethylmethacrylate (PMMA) microfluidic systems. Examples of enclosed polyester and PMMA microchannels are presented, and we discuss the electroosmotic properties of both types of channels, which are important for analytical applications such as capillary electrophoresis.

Chemical Phenomena↗

Spatially and temporally resolved delivery of stimuli to single cells.

This Communication describes the photolysis of individual optically trapped vesicles for delivering spatially and temporally resolved stimuli to single cells. A submicrometer-sized vesicle, which encapsulates the stimuli of interest, is precisely positioned with respect to a select cell by optical trapping. Application of a single focused UV laser pulse photolyzes the trapped vesicle and releases the stimuli onto a localized region of the cell. The spatial resolution of this technique is on the order of several hundreds of nanometers, while the temporal resolution lies in the sub-microsecond range.

Animals↗

Selective electroless and electrolytic deposition of metal for applications in microfluidics: fabrication of a microthermocouple.

This paper describes a general strategy for the fabrication of a microthermocouple based on the spatially defined electroless deposition of metal, followed by annealing and electroplating. We present scanning electron microscopy and atomic force microscopy characterizations of the deposition and annealing process, as well as the performance of the microfabricated Ni-Ag thermocouple. The temperature-voltage curve for this Ni-Ag microthermocouple is linear over the range 0-50 degrees C with a slope of 61.9 degrees C mV(-1). The sensitivity of our temperature measurement, which is limited by the uncertainty of our calibration curve, is approximately 1 degrees C. The optimum figure of merit (Z(opt)) is 1.0 x 10(-5) for this type of Ag-Ni thermocouple. We have fabricated microthermocouples ranging in size from 50 to 300 microm. The microthermocouple was integrated into microchannels and used to measure the in-channel temperature rise caused by the following: (1) a simple acid-base reaction, HCl + NaOH --> H2O + NaCl, and (2) an enzyme-catalyzed biochemical reaction, H2O2 + catalase --> H2O + 1/2 O2. We have also profiled the temperature increase in the presence of electroosmotic flow for a 100-, 200-, and 300-microm channel.

Journal Article↗

Mapping fast flows over micrometer-length scales using flow-tagging velocimetry and single-molecule detection.

This paper describes a technique of characterizing microfluidic flow profiles from slow laminar flow to fast near-turbulent flow. Using a photo-activated fluorophore, nanosecond-duration photolysis pulses from a Nitrogen laser, and high-sensitivity single-molecule detection with Ar+ laser excitation, we report the measurement of flow speeds up to 47 m/s in a 33-microm-wide straight channel and the mapping of flow profiles in a 55-microm-wide microchamber. Sensitive single-molecule detection is necessary both because of the short time delay (submicrosecond) between laser photolysis and fluorescence detection and the fast transit times (as low as 10 ns) of the fluorescent molecules across the diffraction-limited beam waist of the Ar+ laser focus. This technique permits the high-resolution three-dimensional mapping and analysis of a wide range of velocity profiles in confined spaces that measure a few micrometers in dimension.

Fluorescein↗

Fabrication of complex three-dimensional microchannel systems in PDMS.

This paper describes a method for fabricating three-dimensional (3D) microfluidic channel systems in poly(dimethylsiloxane) (PDMS) with complex topologies and geometries that include a knot, a spiral channel, a "basketweave" of channels, a chaotic advective mixer, a system with "braided" channels, and a 3D grid of channels. Pseudo-3D channels, which are topologically equivalent to planar channels, are generated by bending corresponding planar channels in PDMS out of the plane into 3D shapes. True 3D channel systems are formed on the basis of the strategy of decomposing these complex networks into substructures that are planar or pseudo-3D. A methodology is developed that connects these planar and/or pseudo-3D structures to generate PDMS channel systems with the original 3D geometry. This technique of joining separate channel structures can also be used to create channel systems in PDMS over large areas by connecting features on different substrates. The channels can be used as templates to form 3D structures in other materials.

Dimethylpolysiloxanes↗

Electrophoretic separation and confocal laser-induced fluorescence detection at ultralow concentrations in constricted fused-silica capillaries.

Laser-induced fluorescence detection of labeled amino acids in a flowing stream at femtomolar (10(-15)M) concentrations was achieved by using a fused-silica capillary flow-cell comprising a constricted thin-walled detection region with inner diameters (IDs) ranging from 2 to 8 microm. The diameter of the constricted region was made to match a diffraction-limited focus of a uniphase transverse electromagnetic mode (TEM(00)) laser beam. Optimization of capillary dimensions and geometries (i.e., curvature, wall thickness, and outer-inner diameter ratio were performed in order to minimize cylindrical lensing of the focused laser beam. The fluorescence was collected in a confocal optical setup using a 1.3 numerical aperture (NA), 100x oil-immersion objective and a single-photon-counting avalanche diode (SPAD). Under conditions of fluid flow, the constriction in the capillary forces all analytes to traverse across the laser probe volume, resulting in a high sampling efficiency. Fluorescein isothiocyanate-labeled glutamate (FITC-Glu) was electrophoretically separated and detected in capillaries having an ID of 2 microm at the constricted region with detection limits of 250 fM (signal-to-noise ratio (S/N) = 3) in the injected solution.

Amino Acids↗

A cell-based bar code reader for high-throughput screening of ion channel-ligand interactions.

This paper presents a microfluidics-patch clamp platform for performing high-throughput screening and rapid characterization of weak-affinity ion channel-ligand interactions. This platform integrates a microfluidic chip consisting of multiple channels entering an open volume with standard patch clamp equipment. The microfluidic chip is placed on a motorized scanning stage and the method relies on the ability to scan rapidly, on the order of milliseconds, a patch-clamped cell across discrete zones of different solutions created in the open volume. Under ideal conditions, this method has the capacity to obtain kinetically resolved patch clamp measurements and dose-response curves of up to 10(3) ligand solutions in a single day.

Animals↗

Monitoring cell survival after extraction of a single subcellular organelle using optical trapping and pulsed-nitrogen laser ablation.

This paper characterizes cell viability in three different cell lines--Chinese hamster ovary cells (CHO), neuroblastoma cells fused with glialoma cells (NG108-15) and murine embryonic stem cells (ES-D3)--after N2 laser disruption of the cell membrane and removal, via optical trapping, of a single subcellular organelle. Morphological changes and viability (as determined by live/dead fluorescent stains) of the cell were monitored every half hour over a 4-h period postsurgery. The ability of the cell to survive organelle extraction was found to depend both on the conditions under which surgery was performed and on the cell type. The average viability after surgery for CHO cells was approximately 80%, for NG 108 cells it was approximately 30% and for ES-D3 cells postsurgery viability was approximately 10%. From over 600 surgeries we found the survival of the cell is determined almost exclusively within the first hour postsurgery regardless of cell line. The optimal pulse energy for N2 laser ablation was approximately 0.7 microJ. The N2 pulse produced an approximately 1-3 microm hole in the cell membrane and proved to be the primary source of cell death in those cells that did not survive the procedure.

Animals↗