Search PubMed⌕ Search

Biomedical subjects

Daniel M Spielman

Publications and source records attributed to Daniel M Spielman.

4 recordsLinked to original sources

Simple analytic variable density spiral design.

Variable density spirals have been proposed in a variety of applications, including MR fluoroscopy, cardiac imaging, and MR spectroscopic imaging. In this work, a simple analytic solution for designing a flexible set of variable density spiral trajectory waveforms is presented. The method enables real-time waveform prescription on scanners with limited computational power. Both slew rate-limited and amplitude-limited regimes are incorporated in the design process.

Algorithms↗

Low N-acetyl-aspartate and high choline in the anterior cingulum of recently abstinent methamphetamine-dependent subjects: a preliminary proton MRS study. Magnetic resonance spectroscopy.

Studies based on animal models report that methamphetamine (MA) abuse diminishes dopamine (DA) and serotonin innervation in frontal brain regions. In this in vivo human study, we used proton magnetic resonance spectroscopy (MRS), which yields measures of N-acetyl-aspartate (NAA), a marker of living neurons, to examine frontal brain regions possibly affected by methamphetamine dependence (MD). We tested the hypothesis that MD subjects would exhibit abnormally low levels of NAA, referenced to creatine (Cr), in anterior cingulate gray matter. We further hypothesized that the primary visual cortex, which receives relatively less DA innervation than the frontal brain regions, would show normal NAA/Cr ratios in MD subjects. Subjects included nine MD men (mean+/-standard deviation (S.D.)=32.5+/-6.4 years) and nine age-matched control men (mean+/-S.D.=32.7+/-6.8 years). The MD subjects were MA-free for 4-13 weeks. Proton MRS metabolites were expressed as ratios of creatine; the absolute values of which did not distinguish controls and MD subjects. With regard to metabolite ratios, the MD men had significantly lower NAA/Cr in the cingulum (mean+/-standard error (S.E.): control=1.46+/-0.03; MD=1.30+/-0.03; Mann-Whitney P=0.01) but not in the visual cortex (mean+/-S.E.: control=1.64+/-0.06; MD=1.69+/-11; Mann-Whitney P=0.52) relative to controls. These results provide evidence for NAA/Cr deficit that is selective to the anterior cingulum, at least with respect to visual cortex, in MD subjects. The neuronal compromise that these changes reflect may contribute to the attentional deficits and dampened reward system in MD.

Adult↗

Regularized higher-order in vivo shimming.

A regularized algorithm is presented for localized in vivo shimming. The technique uses first- (X,Y,Z), second- (Z(2), ZX, ZY, X(2)-Y(2), XY), and third-order (Z(3)) shim coils, and is robust when applied to arbitrarily-shaped, as well as off-center, regions of interest (ROIs). A single-shot spiral pulse sequence is used for rapid field map acquisition, and a least-squares calculation of the shim currents is performed to minimize the root-mean-square (RMS) value of the B(0) inhomogeneity over a user-selected ROI. The use of a singular value decomposition (SVD) in combination with a regularization algorithm significantly improves the numerical stability of the least-squares fitting procedure. The fully automated shimming package is implemented on a 3 T GE Signa system and its robust performance is demonstrated in phantom and in vivo studies.

Algorithms↗

Noninvasive measurement of extraction fraction and single-kidney glomerular filtration rate with MR imaging in swine with surgically created renal arterial stenoses.

PURPOSE: To test whether magnetic resonance (MR) imaging enables accurate measurement of extraction fraction (EF) in swine with unilateral renal ischemia and to evaluate effects of renal arterial stenosis on EF and single-kidney glomerular filtration rate. MATERIALS AND METHODS: High-grade unilateral renal arterial stenoses were surgically created in eight pigs. Direct measurements of renal venous and arterial inulin concentration provided reference standard estimates of single-kidney EF. Pigs were imaged with a 1.5-T imager to estimate EF, renal blood flow, and glomerular filtration rate. A breath-hold inversion-recovery spiral sequence was used to measure T1 of blood in the infrarenal inferior vena cava and renal veins after intravenous administration of gadopentetate dimeglumine, and these data were used to calculate EF. Cine-phase contrast material-enhanced imaging of the renal arteries provided quantitative renal blood flow measurements. Bilateral single-kidney glomerular filtration rate was then determined: glomerular filtration rate = renal blood flow x (1 - hematocrit level) x EF. RESULTS: A statistically significant linear correlation was found between EF, as determined with MR imaging, and inulin (r = 0.77). As compared with kidneys without renal arterial stenosis, kidneys with renal arterial stenosis showed 50% (0.14/0.28) EF reduction (P <.01) and 59% glomerular filtration rate reduction (P <.01). CONCLUSION: MR imaging shows promise for in vivo measurement of EF and glomerular filtration rate, which may be useful in assessing the clinical importance of renal arterial stenosis.

Animals↗