Search PubMed⌕ Search

Biomedical subjects

Daniel L Marks

Publications and source records attributed to Daniel L Marks.

At least 37 records · Page 2Linked to original sources

A role for agouti-related protein in appetite regulation in a species with continuous nutrient delivery.

Knowledge of specific neurotransmitters as well as the pathways and mechanisms regulating appetite in ruminants that continually graze, such as sheep, is incomplete. Although fundamentally agouti-related protein (AGRP) has a similar function across species to increase food intake, the regulation of AGRP may vary across grazing and intermittent feeders. To investigate the role of orexigenic peptides in the regulation of feed intake, we first extracted messenger RNA from sheep that were fasted for 3 days, which was then used for PCR followed by cloning and sequencing to demonstrate the presence of hypothalamic AGRP expression. Ovine AGRP was closely related to the bovine, but contained sequence differences with human and mouse AGRP. Analysis of genomic DNA also revealed a similar gene structure to other published species. Secondly, using dual-labeled immunohistochemistry, we determined that there was both increased AGRP immunoreactivity and increased abundance of c-Fos immunoreactivity in AGRP neurons in the arcuate nucleus of fasted sheep. Because AGRP neurons are activated by fasting, we hypothesized that AGRP would stimulate feeding in this ruminant species. Sheep fed ad libitum were injected intracerebroventricularly with concentrations of AGRP at 0.2 and 2.0 nmol/kg. AGRP at 2.0 nmol/kg significantly increased food intake at 4, 6 and 12 h (p < 0.05). A 4th study was done to investigate the interactions of AGRP and neuropeptide Y (NPY) on food intake over a 24-hour period. Intracerebroventricular injections of either AGRP or NPY significantly increased cumulative food intake over saline controls. When AGRP and NPY were injected in combination, food intake was increased over saline controls; however, AGRP did not potentiate the effects of NPY. These results demonstrate that AGRP stimulates food intake in sheep and highlights the important differences between this species and rodent models.

Agouti Signaling Protein↗

Effect of Agouti-related protein in regulation of the hypothalamic-pituitary-thyroid axis in the melanocortin 4 receptor knockout mouse.

Agouti-related protein (AGRP) is thought to be one of the neuropeptides mediating the effects of leptin on appetite and satiety. The central administration of AGRP not only stimulates food intake, but also inhibits the hypothalamic-pituitary-thyroid axis (HPT) axis, closely replicating the central hypothyroid state induced by fasting. AGRP binds as an endogenous antagonist or inverse agonist of the central melanocortin receptors but has also been hypothesized to have melanocortin receptor-independent effects. Thus, we determined whether the central effects of AGRP on the HPT axis are altered in mice with selective deletion of the melanocortin 4 receptor (MC4-R). AGRP or artificial cerebrospinal fluid was administered daily into the lateral ventricle of adult, male MC4-R knockout and wild-type (WT) mice for 3 d. AGRP significantly increased the cumulative food intake and weight of white and brown adipose tissue, suppressed circulating levels of T(4) [control vs. AGRP in WT (microg/dl): 4.54 +/- 0.16 vs. 3.87 +/- 21], and inhibited proTRH mRNA content in the hypothalamic paraventricular nucleus of WT mice (control vs. AGRP in WT (density units +/- sem): 4.65 +/- 0.50 vs. 2.47 +/- 0.17). In contrast, no significant effects of AGRP were observed in any of these parameters in the MC4-R knockout mice. These data suggest that AGRP signaling to TRH hypophysiotropic neurons in the paraventricular nucleus is primarily mediated by the MC4-R and therefore, binding to the MC3-R or other putative AGRP receptors may have only a minor role.

Adipose Tissue↗

Near-infrared dyes as contrast-enhancing agents for spectroscopic optical coherence tomography.

Optical coherence tomography (OCT) images of biological tissues often have low contrast. Spectroscopic optical coherence tomography (SOCT) methods have been developed to enhance contrast but remain limited because most tissues are not spectrally active in the frequency bands of laser sources commonly used in OCT. Near-infrared (NIR) dyes with absorption spectra features within the OCT source spectrum can be used for enhancing contrast in this situation. We introduce and demonstrate the use of NIR dyes as contrast agents for SOCT. Contrast-enhanced images are compared with fluorescence microscopy, demonstrating a link between SOCT and fluorescence imaging.

Apium↗

Structural and functional imaging of 3D microfluidic mixers using optical coherence tomography.

To achieve high mixing efficiency in microfluidic devices, complex designs are often required. Microfluidic devices have been evaluated with light and confocal microscopy, but fluid-flow characteristics at different depths are difficult to separate from the en face images produced. By using optical coherence tomography (OCT), an imaging modality capable of imaging 3D microstructures at micrometer-scale resolutions over millimeter-size scales, we obtained 3D dynamic functional and structural data for three representative microfluidic mixers: a Y channel mixer, a 3D serpentine mixer, and a vortex mixer. In the serpentine mixer, OCT image analysis revealed that the mixing efficiency was linearly dependent on the Reynolds number, whereas it appeared to have exponential dependence when imaged with light microscopy. The visual overlap of fluid flows in light-microscopy images leads to an overestimation of the mixing efficiency, an effect that was eliminated with OCT imaging. Doppler OCT measurements determined velocity profiles at various points in the serpentine mixer. Mixing patterns in the vortex mixer were compared with light-microscopy and OCT image analysis. These results demonstrate that OCT can significantly improve the characterization of 3D microfluidic device structure and function.

Microfluidics↗

Ala67Thr polymorphism in the Agouti-related peptide gene is associated with inherited leanness in humans.

A role for melanocortin signaling in the regulation of body weight in humans has been clearly established. Haploinsufficiency of the type 4 melanocortin receptor is associated with early-onset obesity, implying that this receptor provides an important tonic inhibition of weight gain. Agouti-related peptide (AGRP) is an endogenous antagonist of melanocortin signaling. Therefore, loss of AGRP function could lead to the expression of a lean phenotype. We investigated the potential role of AGRP in human weight regulation by examining the association between the Ala67Thr AGRP polymorphism and indices of body composition. Significant associations were found between homozygosity for this mutation (n = 8) and body composition phenotype in 874 subjects of the Quebec family study (QFS). By PCR-RFLP analysis, we have identified eight individuals who are homozygous for the 67Thr variant allele within the QFS population, where none were observed in SAFHS. The eight QFS homozygote individuals have lower weight (-16%; P = 0.02), body mass index (-17%; P = 0.01), fat free mass (-9%; P = 0.002), fat mass (FM) (-20%; P = 0.04), and leptin (-20%; P = 0.02) when compared to those carrying at least one 67Ala allele. Individuals homozygous for the 67Thr allele had a BMI that was either at or slightly below an ideal range for their age. Thus, the Ala67Thr AGRP polymorphism is associated with lower body weight in humans, with the largest effect being observed on body FM. We did not observe any difference in the stability or cellular distribution of the mutant protein in a heterologous expression system, thus the mechanism of this effect requires further investigation.

Adult↗

Nonlinear interferometric vibrational imaging.

Coherent anti-Stokes Raman scattering (CARS) processes are "coherent," but the phase of the anti-Stokes radiation is lost by most incoherent spectroscopic CARS measurements. We propose a Raman microscopy imaging method called nonlinear interferometric vibrational imaging, which measures Raman spectra by obtaining the temporal anti-Stokes signal through nonlinear interferometry. With a more complete knowledge of the anti-Stokes signal, we show through simulations that a high-resolution Raman spectrum can be obtained of a molecule in a single pulse using broad band radiation. This could be useful for identifying the three-dimensional spatial distribution of molecular species in tissue.

DNA↗

Optical coherence tomography: feasibility for basic research and image-guided surgery of breast cancer.

Diagnostic trends in medicine are being directed toward cellular and molecular processes, where treatment regimens are more amenable for cure. Optical imaging is capable of performing cellular and molecular imaging using the short wavelengths and spectroscopic properties of light. Diffuse optical tomography is an optical imaging technique that has been pursued as an alternative to X-ray mammography. While this technique permits non-invasive optical imaging of the whole breast, to date it is incapable of resolving features at the cellular level. Optical coherence tomography (OCT) is an emerging high-resolution biomedical imaging technology that for larger and undifferentiated cells can perform cellular-level imaging at the expense of imaging depth. OCT performs optical ranging in tissue and is analogous to ultrasound except reflections of near-infrared light are detected rather than sound. In this paper, an overview of the OCT technology is provided, followed by images demonstrating the feasibility of using OCT to image cellular features indicative of breast cancer. OCT images of a well-established carcinogen-induced rat mammary tumor model were acquired. Images from this common experimental model show strong correlation with corresponding histopathology. These results illustrate the potential of OCT for a wide range of basic research studies and for intra-operative image-guidance to identify foci of tumor cells within surgical margins during the surgical treatment of breast cancer.

Animals↗

Real-time digital signal processing-based optical coherence tomography and Doppler optical coherence tomography.

We present the development and use of a real-time digital signal processing (DSP)-based optical coherence tomography (OCT) and Doppler OCT system. Images of microstructure and transient fluid-flow profiles are acquired using the DSP architecture for real-time processing of computationally intensive calculations. This acquisition system is readily configurable for a wide range of real-time signal processing and image processing applications in OCT.

Algorithms↗

Engineered microsphere contrast agents for optical coherence tomography.

Contrast agents are utilized in virtually every imaging modality to enhance diagnostic capabilities. We introduce a novel class of optical contrast agent, namely, encapsulating microspheres, that are based not on fluorescence but on scattering nanoparticles within the shell or core. The agents are suitable for reflection- or scattering-based techniques such as optical coherence tomography, light microscopy, and reflectance confocal microscopy. We characterize the optical properties of gold-, melanin-, and carbon-shelled contrast agents and demonstrate enhancement of optical coherence tomography imaging after intravenous injection of such an agent into a mouse.

Animals↗

Fast-Fourier-domain delay line for in vivo optical coherence tomography with a polygonal scanner.

We demonstrate in vivo optical coherence tomography using a Fourier-domain optical delay line constructed with a commercially available polygonal scanner. The 20-faceted polygonal mirror array, capable of scanning at rates up to 15 kHz, is implemented at 4 kHz to acquire 500 x 500 pixel images at 8 frames/s with a signal-to-noise ratio of 80 dB. Features of this delay line include scalability to high repetition rates, 98.6% linearity in group delay over 2 mm, and bandwidth support exceeding 150 nm. Images are obtained in an animal model (Xenopus laevis), and limitations due to phase-delay nonlinearity and polygon asymmetry are discussed.

Animals↗

Functional optical coherence tomography for detecting neural activity through scattering changes.

We have demonstrated functional optical coherence tomography (fOCT) for neural imaging by detecting scattering changes during the propagation of action potentials through neural tissue. OCT images of nerve fibers from the abdominal ganglion of the sea slug Aplysia californica were taken before, during, and after electrical stimulation. Images acquired during stimulation showed localized reversible increases in scattering compared with those acquired before stimulation. Motion-mode OCT images of nerve fibers showed transient scattering changes from spontaneous action potentials. These results demonstrate that OCT is sensitive to the optical changes in electrically active nerve fibers.

Abdomen↗

Autofocus algorithm for dispersion correction in optical coherence tomography.

Practical clinical optical coherence tomography (OCT) systems require automatic tools for identifying and correcting flaws in OCT images. One type of flaw is the loss of image detail owing to the dispersion of the medium, which in most cases is unknown. We present an autofocus algorithm for estimating the delay line and material dispersion from OCT reflectance data, integrating a previously presented dispersion compensation algorithm to correct the data. The algorithm is based on minimizing the Renyi entropy of the corrected axial-scan image, which is a contrast-enhancement criterion. This autofocus algorithm can be used in conjunction with a high-speed, digital-signal-processor-based OCT acquisition system for rapid image correction.

Algorithms↗

Projected index computed tomography.

Projected index computed tomography (PICT) is a new imaging technique that provides a computed reconstruction of the index of refraction of a sample. PICT makes use of data from standard optical coherence tomography images taken from several view angles to determine a mapping of the refractive indices of the sample. A rectilinear propagation model is assumed, so the data are understood to be related to the line integral of the refractive index in the beam paths. These data thus provide a set of angular projections of the sample. The spatial distribution of the index of the object may then be reconstructed by use of standard filtered backprojection techniques. The resultant PICT images are free of the spatial distortion that is inherent in standard optical cross-sectional images and correspond well to the manufactured dimensions of specific samples.

Image Processing, Computer-Assisted↗

Digital algorithm for dispersion correction in optical coherence tomography for homogeneous and stratified media.

The resolution of optical coherence tomography (OCT) often suffers from blurring caused by material dispersion. We present a numerical algorithm for computationally correcting the effect of material dispersion on OCT reflectance data for homogeneous and stratified media. This is experimentally demonstrated by correcting the image of a polydimethyl siloxane microfludic structure and of glass slides. The algorithm can be implemented using the fast Fourier transform. With broad spectral bandwidths and highly dispersive media or thick objects, dispersion correction becomes increasingly important.

Journal Article↗

The role of the melanocortin-3 receptor in cachexia.

Cachexia refers to a synergistic combination of a dramatic decrease in appetite and an increase in metabolism of fat and lean body mass. This combination is found in a number of chronic diseases and is an important determinant of mortality. In this paper, we provide evidence that in both acute and chronic disease models, blockade of the MC4-R results in a dramatic attenuation of cachexia. We have also demonstrated that blockade of the melanocortin-3 receptor (MC3-R) leads to enhanced disease-associated cachexia. Ultimately, this work may lead to investigation of drug therapy for this widespread medical problem.

Adipose Tissue↗

Differential role of melanocortin receptor subtypes in cachexia.

Animals and humans respond to starvation with a complex neuroendocrine response that ultimately leads to an increase in appetite, a sparing of lean body mass (LBM) and burning of fat, and an overall decrease in basal metabolic rate. In contrast, cachexia is a pathological state of malnutrition associated with many infections and chronic diseases, wherein appetite is diminished concomitant with an increase in metabolic rate, and a relative wasting of LBM. In previous studies, we demonstrated that anorexia and weight loss in mouse cachexia models induced by lipopolysaccharide (LPS) administration and by tumor growth are ameliorated by central melanocortin-4 (MC4) receptor (MC4-R) blockade. In contrast to the results seen with MC4 blockade, melanocortin-3 (MC3) receptor knockout (MC3-RKO) mice show illness-induced anorexia and weight loss with LPS administration and with cytokine administration, and they have similar decreases in mobility. Both MC3-RKOs and MC4-RKOs have an intact corticosterone response and fever with LPS injection. In tumor models, we show that MC4-RKO mice resist the loss of LBM brought about by tumor growth, whereas MC3-RKO animals show enhanced tissue wasting. These data underscore the importance of central melanocortin signaling in weight homeostasis and demonstrate differential effects of MC3-R and MC4-R blockade on the development of cachexia.

Animals↗

Digital refraction distortion correction with an astigmatic coherence sensor.

We demonstrate the sensing and correction of an isoplanatic refractive distortion (not lens aberrations), using the complete measurement of the partially coherent field in an aperture that the previously described astigmatic coherence sensor provides. Isoplanatic distortions, and in general distortions that do not cause energy loss, maintain the orthogonality of the coherent modes. We use the fact that a common distortion will occur to all coherent modes to separate the distortion from the source behind it, rather than requiring a reference source at a different wavelength. Digital deconvolution was performed on the full four-dimensional partially coherent field for simultaneously computing the distortion and the source intensity distribution.

Journal Article↗

Optical probes and techniques for molecular contrast enhancement in coherence imaging.

Optics has played a key role in the rapidly developing field of molecular imaging. The spectroscopic nature and high-resolution imaging capabilities of light provide a means for probing biological morphology and function at the cellular and molecular levels. While the use of bioluminescent and fluorescent probes has become a mainstay in optical molecular imaging, a large number of other optical imaging modalities exist that can be included in this emerging field. In vivo imaging technologies such as optical coherence tomography and reflectance confocal microscopy have had limited use of molecular probes. In the last few years, novel nonfluorescent and nonbioluminescent molecular imaging probes have been developed that will initiate new directions in coherent optical molecular imaging. Classes of probes reviewed in this work include those that alter the local optical scattering or absorption properties of the tissue, those that modulate these local optical properties in a predictable manner, and those that are detected utilizing spectroscopic optical coherence tomography (OCT) principles. In addition to spectroscopic OCT, novel nonlinear interferometric imaging techniques have recently been developed to detect endogenous molecules. Probes and techniques designed for coherent molecular imaging are likely to improve the detection and diagnostic capabilities of OCT.

Animals↗