Search PubMed⌕ Search

Biomedical subjects

Daniel Irimia

Publications and source records attributed to Daniel Irimia.

9 recordsLinked to original sources

Universal microfluidic gradient generator.

The study of cellular responses to chemical gradients in vitro would greatly benefit from experimental systems that can generate precise and stable gradients comparable to chemical nonhomogeneities occurring in vivo. Recently, microfluidic devices have been demonstrated for linear gradient generation for biological applications with unmatched accuracy and stability. However, no systematic approach exists at this time for generating other gradients of target spatial configuration. Here we demonstrate experimentally and provide mathematical proof for a systematic approach to generating stable gradients of any profile by the controlled mixing of two starting solutions.

Microfluidics↗

Murine B16 melanomas expressing high levels of the chemokine stromal-derived factor-1/CXCL12 induce tumor-specific T cell chemorepulsion and escape from immune control.

The chemokine, stromal-derived factor-1/CXCL12, is expressed by normal and neoplastic tissues and is involved in tumor growth, metastasis, and modulation of tumor immunity. T cell-mediated tumor immunity depends on the migration and colocalization of CTL with tumor cells, a process regulated by chemokines and adhesion molecules. It has been demonstrated that T cells are repelled by high concentrations of the chemokine CXCL12 via a concentration-dependent and CXCR4 receptor-mediated mechanism, termed chemorepulsion or fugetaxis. We proposed that repulsion of tumor Ag-specific T cells from a tumor expressing high levels of CXCL12 allows the tumor to evade immune control. Murine B16/OVA melanoma cells (H2b) were engineered to constitutively express CXCL12. Immunization of C57BL/6 mice with B16/OVA cells lead to destruction of B16/OVA tumors expressing no or low levels of CXCL12 but not tumors expressing high levels of the chemokine. Early recruitment of adoptively transferred OVA-specific CTL into B16/OVA tumors expressing high levels of CXCL12 was significantly reduced in comparison to B16/OVA tumors, and this reduction was reversed when tumor-specific CTLs were pretreated with the specific CXCR4 antagonist, AMD3100. Memory OVA-specific CD8+ T cells demonstrated antitumor activity against B16/OVA tumors but not B16/OVA.CXCL12-high tumors. Expression of high levels of CXCL12 by B16/OVA cells significantly reduced CTL colocalization with and killing of target cells in vitro in a CXCR4-dependent manner. The repulsion of tumor Ag-specific T cells away from melanomas expressing CXCL12 confirms the chemorepellent activity of high concentrations of CXCL12 and may represent a novel mechanism by which certain tumors evade the immune system.

Animals↗

Cell handling using microstructured membranes.

Gentle and precise handling of cell suspensions is essential for scientific research and clinical diagnostic applications. Although different techniques for cell analysis at the micro-scale have been proposed, many still require that preliminary sample preparation steps be performed off the chip. Here we present a microstructured membrane as a new microfluidic design concept, enabling the implementation of common sample preparation procedures for suspensions of eukaryotic cells in lab-on-a-chip devices. We demonstrate the novel capabilities for sample preparation procedures by the implementation of metered sampling of nanoliter volumes of whole blood, concentration increase up to three orders of magnitude of sparse cell suspension, and circumferentially uniform, sequential exposure of cells to reagents. We implemented these functions by using microstructured membranes that are pneumatically actuated and allowed to reversibly decouple the flow of fluids and the displacement of eukaryotic cells in suspensions. Furthermore, by integrating multiple structures on the same membrane, complex sequential procedures are possible using a limited number of control steps.

Cell Line, Tumor↗

Microfluidic system for measuring neutrophil migratory responses to fast switches of chemical gradients.

Experimental systems that provide temporal and spatial control of chemical gradients are required for probing into the complex mechanisms of eukaryotic cell chemotaxis. However, no current technique can simultaneously generate stable chemical gradients and allow fast gradient changes. We developed a microfluidic system with microstructured membranes for exposing neutrophils to fast and precise changes between stable, linear gradients of the known chemoattractant Interleukin-8 (IL-8). We observed that rapidly lowering the average concentration of IL-8 within a gradient, while preserving the direction of the gradient, resulted in temporary neutrophil depolarization. Fast reversal of the gradient direction while increasing or decreasing the average concentration also resulted in temporary depolarization. Neutrophils adapted and maintained their directional motility, only when the average gradient concentration was increased and the direction of the gradient preserved. Based on these observations we propose a two-component temporal sensing mechanism that uses variations of chemokine concentration averaged over the entire cell surface and localized at the leading edge, respectively, and directs neutrophil responses to changes in their chemical microenvironment.

Chemotaxis↗

Blood-on-a-chip.

Accurate, fast, and affordable analysis of the cellular component of blood is of prime interest for medicine and research. Yet, most often sample preparation procedures for blood analysis involve handling steps prone to introducing artifacts, whereas analysis methods commonly require skilled technicians and well-equipped, expensive laboratories. Developing more gentle protocols and affordable instruments for specific blood analysis tasks is becoming possible through the recent progress in the area of microfluidics and lab-on-a-chip-type devices. Precise control over the cell microenvironment during separation procedures and the ability to scale down the analysis to very small volumes of blood are among the most attractive capabilities of the new approaches. Here we review some of the emerging principles for manipulating blood cells at microscale and promising high-throughput approaches to blood cell separation using microdevices. Examples of specific single-purpose devices are described together with integration strategies for blood cell separation and analysis modules.

Animals↗

Single-cell chemical lysis in picoliter-scale closed volumes using a microfabricated device.

Investigating the intracellular contents of single cells is essential for understanding physiologic and pathologic processes at the cellular level. While existing protocols for cell lysis and sample preparation work well for larger samples, scaling to a single-cell level is challenging because of unavoidable analyte dilution and losses. Thus, we are proposing a microfabricated device for the controlled handling and mixing of picoliter cell suspension and lysis solution volumes. Cells and fluids are independently isolated in two microchambers of 25-pL volumes using the geometry of the microchannels and the coordinated action of four on-chip thermopneumatic actuators. Virtual walls formed by liquid-air interfaces in the hydrophobic capillary separate the two volumes, which are subsequently allowed to mix after drawing the air out of the capillary connecting the two microchambers. Following cell lysis, a limited and stable dilution of intracellular components is achieved, simplifying the requirements for subsequent analysis. Two assays at single-cell level, one for direct estimation of the intracellular concentration of a soluble dye and the other for indirect evaluation of intracellular quantities of insoluble actin, demonstrate the use of the microfabricated device for single-cell assays.

Calibration↗

Kinetics of intracellular ice formation in one-dimensional arrays of interacting biological cells.

Although cell-cell interactions are known to significantly affect the kinetics of intracellular ice formation (IIF) during tissue freezing, this effect is not well understood. Progress in elucidating the mechanism and role of intercellular ice propagation in tissue freezing has been hampered in part by limitations in experimental design and data analysis. Thus, using rapid-cooling cryomicroscopy, IIF was measured in adherent cells cultured in micropatterned linear constructs (to control cell-cell interactions and minimize confounding factors). By fitting a Markov chain model to IIF data from micropatterned HepG2 cell pairs, the nondimensional rate of intercellular ice propagation was found to be alpha = 10.4 +/- 0.1. Using this measurement, a new generator matrix was derived to predict the kinetics of IIF in linear four-cell constructs; cryomicroscopic measurements of IIF state probabilities in micropatterned four-cell arrays conformed with theoretical predictions (p < 0.05), validating the modeling assumptions. Thus, the theoretical model was extended to allow prediction of IIF in larger tissues, using Monte Carlo techniques. Simulations were performed to investigate the effects of tissue size and ice propagation rate, for one-dimensional tissue constructs containing up to 100 cells and nondimensional propagation rates in the range 0.1 < or = alpha < or = 1000.

Calibration↗

Parametric analysis of intercellular ice propagation during cryosurgery, simulated using monte carlo techniques.

A microscale theoretical model of intracellular ice formation (IIF) in a heterogeneous tissue volume comprising a tumor mass and surrounding normal tissue is presented. Intracellular ice was assumed to form either by intercellular ice propagation or by processes that are not affected by the presence of ice in neighboring cells (e.g., nucleation or mechanical rupture). The effects of cryosurgery on a 2D tissue consisting of 10(4) cells were simulated using a lattice Monte Carlo technique. A parametric analysis was performed to assess the specificity of IIF-related cell damage and to identify criteria for minimization of collateral damage to the healthy tissue peripheral to the tumor. Among the parameters investigated were the rates of interaction-independent IIF and intercellular ice propagation in the tumor and in the normal tissue, as well as the characteristic length scale of thermal gradients in the vicinity of the cryosurgical probe. Model predictions suggest gap junctional intercellular communication as a potential new target for adjuvant therapies complementing the cryosurgical procedure.

Cell Line, Tumor↗

Kinetics and mechanism of intercellular ice propagation in a micropatterned tissue construct.

Understanding the effects of cell-cell interaction on intracellular ice formation (IIF) is required to design optimized protocols for cryopreservation of tissue. To determine the effects of cell-cell interactions during tissue freezing, without confounding effects from uncontrolled factors (such as time in culture, cell geometry, and cell-substrate interactions), HepG2 cells were cultured in pairs on glass coverslips micropatterned with polyethylene glycol disilane, such that each cell interacted with exactly one adjacent cell. Assuming the cell pair to be a finite state system, being either in an unfrozen state (no ice in either cell), a singlet state (IIF in one cell only), or a doublet state (IIF in both cells), the kinetics of state transitions were theoretically modeled and cryomicroscopically measured. The rate of intercellular ice propagation, estimated from the measured singlet state probability, increased in the first 24 h of culture and remained steady thereafter. In cell pairs cultured for 24 h and treated with the gap junction blocker 18beta-glycyrrhetinic acid before freezing, the intercellular ice propagation rate was lower than in untreated controls (p < 0.001), but significantly greater than zero (p < 0.0001). These results suggest that gap junctions mediate some, but not all, mechanisms of ice propagation in tissue.

Biophysical Phenomena↗