Search PubMed⌕ Search

Biomedical subjects

Daniel Gagnon

Publications and source records attributed to Daniel Gagnon.

5 recordsLinked to original sources

CdZnTe strip detector SPECT imaging with a slit collimator.

In this paper, we propose a CdZnTe rotating and spinning gamma camera attached with a slit collimator. This imaging system acquires convergent planar integrals of a radioactive distribution. Two analytical image reconstruction algorithms are proposed. Preliminary phantom studies show that our small CdZnTe camera with a slit collimator outperforms a larger NaI(Tl) camera with a pinhole collimator in terms of spatial resolution in the reconstructed images. The main application of this system is small animal SPECT imaging.

Algorithms↗

3D RBI-EM reconstruction with spherically-symmetric basis function for SPECT rotating slat collimator.

A single photon emission computed tomography (SPECT) rotating slat collimator with strip detector acquires distance-weighted plane integral data, along with the attenuation factor and distance-dependent detector response. In order to image a 3D object, the slat collimator device has first to spin around its axis and then rotate around the object to produce 3D projection measurements. Compared to the slice-by-slice 2D reconstruction for the parallel-hole collimator and line integral data, a more complex 3D reconstruction is needed for the slat collimator and plane integral data. In this paper, we propose a 3D RBI-EM reconstruction algorithm with spherically-symmetric basis function, also called 'blobs', for the slat collimator. It has a closed and spherically symmetric analytical expression for the 3D Radon transform, which makes it easier to compute the plane integral than the voxel. It is completely localized in the spatial domain and nearly band-limited in the frequency domain. Its size and shape can be controlled by several parameters to have desired reconstructed image quality. A mathematical lesion phantom study has demonstrated that the blob reconstruction can achieve better contrast-noise trade-offs than the voxel reconstruction without greatly degrading the image resolution. A real lesion phantom study further confirmed this and showed that a slat collimator with CZT detector has better image quality than the conventional parallel-hole collimator with NaI detector. The improvement might be due to both the slat collimation and the better energy resolution of the CZT detector.

Algorithms↗

Image reconstruction algorithm for a spinning strip CZT SPECT camera with a parallel slat collimator and small pixels.

This paper discusses the use of small pixels in a spinning CdZnTe single photon emission computed tomography (SPECT) camera that is mounted with a parallel slat collimator. In a conventional slat collimation configuration, there is a detector pixel between two adjacent collimator slats. In our design, the pixel size is halved. That is, there are two smaller pixels to replace a regular pixel between two adjacent slats while the collimator remains unchanged. It has an advantage over our older design that uses tilted slats. In order to acquire a complete data set the tilted-slat collimator must spin 360 degrees at each SPECT view while the proposed design requires only 180 degrees at each SPECT view. Computer simulations and phantom experiments have been carried out to investigate the performance of the small-pixel configuration. It is observed that this design has the potential to increase the spatial resolution of the detector while keeping photon counts the same.

Algorithms↗

Phytochemistry of wild populations of Panax quinquefolius L. (North American ginseng).

A survey of the phytochemistry of Panax quinquefolius L. (North American ginseng) collected from wild populations in Ontario, Quebec, Maine, Vermont, and Wisconsin was undertaken. Reverse-phase HPLC was used to determine the natural variation of levels of ginsenosides Rg1, Re, Rf, Rb1, Rc, Rb2, and Rd and their total in leaf, stem, and root of authentic wild-grown material. The totals in roots varied from 1 to 16%, with the greatest number of individual samples having 4-5% total ginsenosides. The lack of ginsenoside Rf in roots of authentic wild populations confirmed its status as a phytochemical marker differentiating American and Asian ginseng. Ten geographically isolated wild populations were collected, and several showed significant variation in the levels of major ginsenosides. There was no statistical difference in mean ginsenoside content between wild and cultivated P. quinquefolius roots at 4 years of age, suggesting there is no phytochemical justification for wild crafting. Baseline data on total ginsenoside levels for authentic wild P. quinquefolius reported here provide reference levels for quality assurance programs.

Canada↗

Image reconstruction algorithm for a rotating slat collimator.

A slat collimator in single photon emission computed tomography consists of a set of parallel slats. As the collimator spins, the detector measures a one-dimensional projection data set. A complete data set can be obtained by rotating the detector/collimator assembly around the object (patient) while the collimator spins continuously. The measured projection data are assumed to be weighted planar integrals of the object. This paper describes the development of an approximate three-dimensional image reconstruction algorithm for a rotating/spinning slat collimator. This algorithm is in filtered backprojection form. Computer simulations were performed to verify the effectiveness of the algorithm.

Algorithms↗