Search PubMed⌕ Search

Biomedical subjects

Daniel A Low

Publications and source records attributed to Daniel A Low.

At least 19 recordsLinked to original sources

Adaptive brachytherapy treatment planning for cervical cancer using FDG-PET.

PURPOSE: A dosimetric study was conducted to compare intracavitary brachytherapy using both a conventional and a custom loading intended to cover a positron emission tomography (PET)-defined tumor volume in patients with cervix cancer. METHODS AND MATERIALS: Eleven patients who underwent an [(18)F]-fluoro-deoxy-D-glucose (FDG)-PET in conjunction with their first, middle, or last brachytherapy treatment were included in this prospective study. A standard plan that delivers 6.5 Gy to point A under ideal conditions was compared with an optimized plan designed to conform the 6.5-Gy isodose surface to the PET defined volume. RESULTS: A total of 31 intracavitary brachytherapy treatments in conjunction with an FDG-PET were performed. The percent coverage of the target isodose surface for the first implant with and without optimization was 73% and 68% (p = 0.21). The percent coverage of the target isodose surface for the mid/final implant was 83% and 70% (p = 0.02), respectively. The dose to point A was higher with the optimized plans for both the first implant (p = 0.02) and the mid/last implants (p = 0.008). The dose to 2 cm(3) and 5 cm(3) of both the bladder and rectum were not significantly different. CONCLUSIONS: FDG-PET based treatment planning allowed for improved dose coverage of the tumor without significantly increasing the dose to the bladder and rectum.

Adult↗

Comparison of helical, maximum intensity projection (MIP), and averaged intensity (AI) 4D CT imaging for stereotactic body radiation therapy (SBRT) planning in lung cancer.

BACKGROUND AND PURPOSE: To compare helical, MIP and AI 4D CT imaging, for the purpose of determining the best CT-based volume definition method for encompassing the mobile gross tumor volume (mGTV) within the planning target volume (PTV) for stereotactic body radiation therapy (SBRT) in stage I lung cancer. MATERIALS AND METHODS: Twenty patients with medically inoperable peripheral stage I lung cancer were planned for SBRT. Free-breathing helical and 4D image datasets were obtained for each patient. Two composite images, the MIP and AI, were automatically generated from the 4D image datasets. The mGTV contours were delineated for the MIP, AI and helical image datasets for each patient. The volume for each was calculated and compared using analysis of variance and the Wilcoxon rank test. A spatial analysis for comparing center of mass (COM) (i.e. isocenter) coordinates for each imaging method was also performed using multivariate analysis of variance. RESULTS: The MIP-defined mGTVs were significantly larger than both the helical- (p=0.001) and AI-defined mGTVs (p=0.012). A comparison of COM coordinates demonstrated no significant spatial difference in the x-, y-, and z-coordinates for each tumor as determined by helical, MIP, or AI imaging methods. CONCLUSIONS: In order to incorporate the extent of tumor motion from breathing during SBRT, MIP is superior to either helical or AI images for defining the mGTV. The spatial isocenter coordinates for each tumor were not altered significantly by the imaging methods.

Humans↗

A prospective study of differences in duodenum compared to remaining small bowel motion between radiation treatments: implications for radiation dose escalation in carcinoma of the pancreas.

PURPOSE: As a foundation for a dose escalation trial, we sought to characterize duodenal and non-duodenal small bowel organ motion between fractions of pancreatic radiation therapy. PATIENTS AND METHODS: Nine patients (4 women, 5 men) undergoing radiation therapy were enrolled in this prospective study. The patients had up to four weekly CT scans performed during their course of radiation therapy. Pancreas, duodenum and non-duodenal small bowel were then contoured for each CT scan. On the initial scan, a four-field plan was generated to fully cover the pancreas. This plan was registered to each subsequent CT scan. Dose-volume histogram (DVH) analyses were performed for the duodenum, non-duodenal small bowel, large bowel, and pancreas. RESULTS: With significant individual variation, the volume of duodenum receiving at least 80% of the prescribed dose was consistently greater than the remaining small bowel. In the patient with the largest inter-fraction variation, the fractional volume of non-duodenal small bowel irradiated to at least the 80% isodose line ranged from 1% to 20%. In the patient with the largest inter-fraction variation, the fractional volume of duodenum irradiated to at least the 80% isodose line ranged from 30% to 100%. CONCLUSION: The volume of small bowel irradiated during four-field pancreatic radiation therapy changes substantially between fractions. This suggests dose escalation may be possible. However, dose limits to the duodenum should be stricter than for other segments of small bowel.

Dose-Response Relationship, Radiation↗

A comparison between amplitude sorting and phase-angle sorting using external respiratory measurement for 4D CT.

Respiratory motion can cause significant dose delivery errors in conformal radiation therapy for thoracic and upper abdominal tumors. Four-dimensional computed tomography (4D CT) has been proposed to provide the image data necessary to model tumor motion and consequently reduce these errors. The purpose of this work was to compare 4D CT reconstruction methods using amplitude sorting and phase angle sorting. A 16-slice CT scanner was operated in ciné mode to acquire 25 scans consecutively at each couch position through the thorax. The patient underwent synchronized external respiratory measurements. The scans were sorted into 12 phases based, respectively, on the amplitude and direction (inhalation or exhalation) or on the phase angle (0-360 degrees) of the external respiratory signal. With the assumption that lung motion is largely proportional to the measured respiratory amplitude, the variation in amplitude corresponds to the variation in motion for each phase. A smaller variation in amplitude would associate with an improved reconstructed image. Air content, defined as the amount of air within the lungs, bronchi, and trachea in a 16-slice CT segment and used by our group as a surrogate for internal motion, was correlated to the respiratory amplitude and phase angle throughout the lungs. For the 35 patients who underwent quiet breathing, images (similar to those used for treatment planning) and animations (used to display respiratory motion) generated using amplitude sorting displayed fewer reconstruction artifacts than those generated using phase angle sorting. The variations in respiratory amplitude were significantly smaller (P < 0.001) with amplitude sorting than those with phase angle sorting. The subdivision of the breathing cycle into more (finer) phases improved the consistency in respiratory amplitude for amplitude sorting, but not for phase angle sorting. For 33 of the 35 patients, the air content showed significantly improved (P < 0.001) correlation with the respiratory amplitude than with the phase angle, suggesting a stronger relationship between internal motion and amplitude. Overall, amplitude sorting performed better than phase angle sorting for 33 of the 35 patients and equally well for two patients who were immobilized with a stereotactic body frame and an abdominal compression plate.

Algorithms↗

Deblurring of breathing motion artifacts in thoracic PET images by deconvolution methods.

In FDG-PET imaging of thoracic tumors, blurring due to breathing motion often significantly degrades the quality of the observed image, which then obscures the tumor boundary. We demonstrate a deblurring technique that combines patient-specific motion estimates of tissue trajectories with image deconvolution techniques, thereby partially eliminating breathing-motion induced artifacts. Two data sets were used to evaluate the methodology including mobile phantoms and clinical images. The clinical images consist of PET/CT co-registered images of patients diagnosed with lung cancer. A breathing motion model was used to locally estimate the location-dependent tissue location probability function (TLP) due to breathing. The deconvolution process is carried by an expectation-maximization (EM) iterative algorithm using the motion-based TLP. Several methods were used to improve the robustness of the deblurring process by mitigating noise amplification and compensating for motion estimate uncertainties. The mobile phantom study with controlled settings demonstrated significant reduction in underestimation error of concentration in high activity case without significant superiority between the different applied methods. In case of medium activity concentration (moderate noise levels), less improvement was reported (10%-15% reduction in underestimation error relative to 15%-20% reduction in high concentration). Residual denoising using wavelets offered the best performance for this case. In the clinical data case, the image spatial resolution was significantly improved, especially in the direction of greatest motion (cranio-caudal). The EM algorithm converged within 15 and 5 iterations in the large and small tumor cases, respectively. A compromise between a figure-of-merit and entropy minimization was suggested as a stopping criterion. Regularization techniques such as wavelets and Bayesian methods provided further refinement by suppressing noise amplification. Our initial results show that the proposed method provides a feasible framework for improving PET thoracic images, without the need for gated/4-D PET imaging, when 4-D CT is available to estimate tumor motion.

Algorithms↗

A semi-automatic method for peak and valley detection in free-breathing respiratory waveforms.

The existing commercial software often inadequately determines respiratory peaks for patients in respiration correlated computed tomography. A semi-automatic method was developed for peak and valley detection in free-breathing respiratory waveforms. First the waveform is separated into breath cycles by identifying intercepts of a moving average curve with the inspiration and expiration branches of the waveform. Peaks and valleys were then defined, respectively, as the maximum and minimum between pairs of alternating inspiration and expiration intercepts. Finally, automatic corrections and manual user interventions were employed. On average for each of the 20 patients, 99% of 307 peaks and valleys were automatically detected in 2.8 s. This method was robust for bellows waveforms with large variations.

Algorithms↗

Progress toward a microradiation therapy small animal conformal irradiator.

Microradiation therapy (microRT) systems are being designed to provide conformal radiation therapy to small animals enabling quantitative radiation response evaluation. We used a Monte Carlo approach to estimate the radiation dose distributions from proposed blueprints and developed a beam model to aid in the microRT system design process. This process was applied to a prototype irradiator that uses a small (3 mm long and 3 mm in diameter), cylindrical, high-activity 192Ir source delivering the radiation beam using custom-fabricated tungsten collimators. The BEAMnrc Monte Carlo code was used to simulate dose distributions from these prototype collimators. Simulations were performed at three source-to-surface distances (50, 60, and 70 mm), and with five circular field sizes (5, 7.5, 10, 12.5, and 15 mm). A dose to a 50 X 50 X 50 mm3 water phantom with 1 X 1 X 1 mm3 voxel spacing was computed. A multiparameter dose calculation algorithm was developed to efficiently and accurately calculate doses for treatment planning exercises. The parametrization was selected so that the parameters varied smoothly as a function of depth, source-to-surface distance, and field size, allowing interpolation for geometries that were not simulated using the Monte Carlo simulation. Direct comparison of the model with the Monte Carlo simulations showed that the variations were within 5% error for field sizes larger than 10 mm, and up to 10% for smaller field sizes.

Animals↗

The management of respiratory motion in radiation oncology report of AAPM Task Group 76.

This document is the report of a task group of the AAPM and has been prepared primarily to advise medical physicists involved in the external-beam radiation therapy of patients with thoracic, abdominal, and pelvic tumors affected by respiratory motion. This report describes the magnitude of respiratory motion, discusses radiotherapy specific problems caused by respiratory motion, explains techniques that explicitly manage respiratory motion during radiotherapy and gives recommendations in the application of these techniques for patient care, including quality assurance (QA) guidelines for these devices and their use with conformal and intensity modulated radiotherapy. The technologies covered by this report are motion-encompassing methods, respiratory gated techniques, breath-hold techniques, forced shallow-breathing methods, and respiration-synchronized techniques. The main outcome of this report is a clinical process guide for managing respiratory motion. Included in this guide is the recommendation that tumor motion should be measured (when possible) for each patient for whom respiratory motion is a concern. If target motion is greater than 5 mm, a method of respiratory motion management is available, and if the patient can tolerate the procedure, respiratory motion management technology is appropriate. Respiratory motion management is also appropriate when the procedure will increase normal tissue sparing. Respiratory motion management involves further resources, education and the development of and adherence to QA procedures.

Guidelines as Topic↗

Novel breathing motion model for radiotherapy.

PURPOSE: An accurate model of breathing motion under quiet respiration is desirable to obtain the most accurate and conformal dose distributions for mobile lung cancer lesions. On the basis of recent lung motion measurements and the physiologic functioning of the lungs, we have determined that the motion of lung and lung tumor tissues can be modeled as a function of five degrees of freedom, the position of the tissues at a user-specified reference breathing phase, tidal volume and its temporal derivative airflow (tidal volume phase space). Time is an implicit variable in this model. METHODS AND MATERIALS: To test this hypothesis, a mathematical model of motion was developed that described the motion of objects p in the lungs as linear functions of tidal volume and airflow. The position of an object was described relative to its position -->P0 at the reference tidal volume and zero airflow, and the motion of the object was referenced to this position. Hysteresis behavior was hypothesized to be caused by pressure imbalances in the lung during breathing and was, in this model, a function of airflow. The motion was modeled as independent tidal volume and airflow displacement vectors, with the position of the object at time t equal to the vector sum -->rP(t) = -->rv(t) + -->rf(t) where -->rv(t) and -->rf(t) were displacement vectors with magnitudes approximated by linear functions of the tidal volume and airflow. To test this model, we analyzed five-dimensional CT scans (CT scans acquired with simultaneous real-time monitoring of the tidal volume) of 4 patients. The scans were acquired throughout the lungs, but the trajectories were analyzed in the couch positions near the diaphragm. A template-matching algorithm was implemented to identify the positions of the points throughout the 15 scans. In total, 76 points throughout the 4 patients were tracked. The lateral motion of these points was minimal; thus, the model was described in two spatial dimensions, with a total of six parameters necessary to describe the 30 degrees of freedom inherent in the 15 positions. RESULTS: For the 76 evaluated points, the average discrepancy (the distance between the measured and prediction positions) of the 15 locations for each tracked point was 0.75 +/- 0.25 mm, with an average maximal discrepancy of 1.55 +/- 0.54 mm. The average discrepancy was also tabulated as a fraction of the breathing motion. Discrepancies of <10% and 15% of the overall motion occurred in 73% and 95% of the tracked points, respectively. CONCLUSION: The motion tracking algorithms are being improved and automated to provide more motion data to test the models. This may allow a measurement of the motion-fitting parameters throughout the lungs. If the parameters vary smoothly, interpolation may be possible, yielding a continuous mathematical model of the breathing motion throughout the lungs. The utility of the model will depend on its stability as a function of time. If the model is only robust during the measurement session, it may be useful for determining lung function. If it is robust for weeks, it may be useful for treatment planning and gating of lung treatments. The use of tidal volume phase space for characterizing breathing motion appears to have provided, for the first time, the potential for a patient-specific mathematical model of breathing motion.

Humans↗

Sequential FDG-PET brachytherapy treatment planning in carcinoma of the cervix.

PURPOSE: To evaluate the utility of sequential (18)F-fluorodeoxyglucose positron emission tomography (FDG-PET) imaging for brachytherapy treatment planning in patients with carcinoma of the cervix. METHODS AND MATERIALS: Twenty-four patients with carcinoma of the cervix were included in this prospective study. The clinical stage of their disease was Ib (7), IIa (1), IIb (7), and IIIb (9). Patients were treated with irradiation and brachytherapy, with the majority receiving concurrent weekly cisplatin chemotherapy. Patients underwent diagnostic FDG-PET imaging before treatment, sequential FDG-PET brachytherapy imaging during treatment, and diagnostic FDG-PET 3 months after treatment completion. Delineation of the gross tumor volume, bladder, and rectum was performed for all scans using a commercially available treatment-planning system. Actual treatment delivery was based on two-dimensional orthogonal planning. RESULTS: The mean gross tumor volume and percent coverage by the target isodose surface for the initial, mid, and last implant were 37 cm3, 17 cm3, and 10 cm3 and 68%, 76%, and 79%, respectively. Nine of 11 patients were found to have continued decrease in tumor volume as measured by FDG-PET, with 3 patients having complete regression of their tumor before treatment was completed. The maximal bladder and rectal doses obtained from three-dimensional dose-volume histograms were significantly higher than the International Commission on Radiation Units and Measurements Report 38 bladder and rectal points obtained by two-dimensional treatment-planning. CONCLUSIONS: Sequential FDG-PET brachytherapy imaging identifies the tumor response in individual patients, potentially making patient-specific brachytherapy treatment planning possible.

Adult↗

A fourier analysis of the dose grid resolution required for accurate IMRT fluence map optimization.

We present a theoretical and empirical analysis of the errors associated with the spatial discretization of the dose grid employed in optimized intensity modulated radiation therapy (IMRT) treatment plans. An information theory based Fourier analysis of the accuracy of discrete representations of three-dimensional dose distributions is presented. When applied to beamlet-based IMRT dose distributions, the theory produces analytic integrals that can bound worst case aliasing errors that can occur regardless of the location and orientation of the dose grid. The predictions of this theory are compared to empirical results obtained by solving a linear-programming based fluence-map optimization model to global optimality. A reasonable agreement between worst case estimates and the empirical results is attributed to the fact that the optimization takes advantage of aliasing to produce an optimal plan. We predicted and empirically demonstrated that an isotropic dose grid with <2.5 mm spacing is sufficient to prevent dose errors larger than a percent. However, we noted that in practice this resolution is mostly needed in high-dose target regions. Finally, a multiresolution 2-4-6 mm spacing model was developed and empirically tested where these spacings were applied to targets, structures, and tissue, respectively.

Algorithms↗

Quantitation of the reconstruction quality of a four-dimensional computed tomography process for lung cancer patients.

We have developed a four-dimensional computed tomography (4D CT) technique for mapping breathing motion in radiotherapy treatment planning. A multislice CT scanner (1.5 mm slices) operated in ciné mode was used to acquire 12 contiguous slices in each couch position for 15 consecutive scans (0.5 s rotation, 0.25 s between scans) while the patient underwent simultaneous quantitative spirometry measurements to provide a sorting metric. The spirometry-sorted scans were used to reconstruct a 4D data set. A critical factor for 4D CT is quantifying the reconstructed data set quality which we measure by correlating the metric used relative to internal-object motion. For this study, the internal air content within the lung was used as a surrogate for internal motion measurements. Thresholding and image morphological operations were applied to delineate the air-containing tissues (lungs, trachea) from each CT slice. The Hounsfield values were converted to the internal air content (V). The relationship between the air content and spirometer-measured tidal volume (v) was found to be quite linear throughout the lungs and was used to estimate the overall accuracy and precision of tidal volume-sorted 4D CT. Inspection of the CT-scan air content as a function of tidal volume showed excellent correlations (typically r>0.99) throughout the lung volume. Because of the discovered linear relationship, the ratio of internal air content to tidal volume was indicative of the fraction of air change in each couch position. Theoretically, due to air density differences within the lung and in room, the sum of these ratios would equal 1.11. For 12 patients, the mean value was 1.08 +/- 0.06, indicating the high quality of spirometry-based image sorting. The residual of a first-order fit between v and V was used to estimate the process precision. For all patients, the precision was better than 8%, with a mean value of 5.1% +/- 1.9%. This quantitative analysis highlights the value of using spirometry as the metric in sorting CT scans. The 4D reconstruction provides the CT data required to measure the three-dimensional trajectory of tumor and lung tissue during free breathing.

Air↗

Comparison of spirometry and abdominal height as four-dimensional computed tomography metrics in lung.

An important consideration in four-dimensional CT scanning is the selection of a breathing metric for sorting the CT data and modeling internal motion. This study compared two noninvasive breathing metrics, spirometry and abdominal height, against internal air content, used as a surrogate for internal motion. Both metrics were shown to be accurate, but the spirometry showed a stronger and more reproducible relationship than the abdominal height in the lung. The abdominal height was known to be affected by sensor placement and patient positioning while the spirometer exhibited signal drift. By combining these two, a normalization of the drift-free metric to tidal volume may be generated and the overall metric precision may be improved.

Abdomen↗

Reduction of motion blurring artifacts using respiratory gated CT in sinogram space: a quantitative evaluation.

Techniques have been developed for reducing motion blurring artifacts by using respiratory gated computed tomography (CT) in sinogram space and quantitatively evaluating the artifact reduction. A synthetic sinogram was built from multiple scans intercepting a respiratory gating window. A gated CT image was then reconstructed using the filtered back-projection algorithm. Wedge phantoms, developed for quantifying the motion artifact reduction, were scanned while being moved using a computer-controlled linear stage. The resulting artifacts appeared between the high and low density regions as an apparent feature with a Hounsfield value that was the average of the two regions. A CT profile through these regions was fit using two error functions, each modeling the partial-volume averaging characteristics for the unmoving phantom. The motion artifact was quantified by determining the apparent distance between the two functions. The blurring artifact had a linear relationship with both the speed and the tangent of the wedge angles. When gating was employed, the blurring artifact was reduced systematically at the air-phantom interface. The gated image of phantoms moving at 20 mm/s showed similar blurring artifacts as the nongated image of phantoms moving at 10 mm/s. Nine patients were also scanned using the synchronized respiratory motion technique. Image artifacts were evaluated in the diaphragm, where high contrast interfaces intercepted the imaging plane. For patients, this respiratory gating technique reduced the blurring artifacts by 9%-41% at the lung-diaphragm interface.

Air↗

Computed tomography studies of lung mechanics.

The study of lung mechanics has progressed from global descriptions of lung pressure and volume relationships to the high-resolution, three-dimensional, quantitative measurement of dynamic regional mechanical properties and displacements. X-ray computed tomography (CT) imaging is ideally suited to the study of regional lung mechanics in intact subjects because of its high spatial and temporal resolution, correlation of functional data with anatomic detail, increasing volumetric data acquisition, and the unique relationship between CT density and lung air content. This review presents an overview of CT measurement principles and limitations for the study of regional mechanics, reviews some of the early work that set the stage for modern imaging approaches and impacted the understanding and management of patients with acute lung injury, and presents evolving novel approaches for the analysis and application of dynamic volumetric lung image data.

Humans↗

Treatment planning guidelines regarding the use of CT/PET-guided IMRT for cervical carcinoma with positive paraaortic lymph nodes.

PURPOSE: Computed tomography (CT)/positron emission tomography (PET)-guided intensity-modulated radiotherapy of the paraaortic lymph nodes (PALNs) has been proposed for patients with cervical carcinoma and paraaortic metastasis. This investigation attempted to determine the guidelines regarding the selection of appropriate treatment parameters (e.g., number of beams, beam geometry) and organ-specific parameters (e.g., importance weighting and tolerance dose) for intensity-modulated radiotherapy planning for the PALNs. METHODS AND MATERIALS: Patients underwent imaging using CT and PET. The images were registered, and the structures were contoured. A goal dose of 50.4 Gy and 59.4 Gy was assigned to the clinical target volume (lymph node bed) and gross tumor volume (PET-delineated PALNs), respectively. For each patient, multiple treatment plans using various beam geometries and planning parameters were executed and evaluated in terms of the dose-volume histograms of the target and critical structures. RESULTS: Acceptable sparing of the stomach, liver, and colon was achieved, regardless of the number of beams used. Sparing of the spinal cord was strongly dependent on the number and arrangement of the beams. Varying the number and arrangement of the beams affected small intestine sparing, but the amount of sparing was limited because the small intestine overlapped the target volumes, and, therefore, received the prescription dose. Adjusting the number of beams, beam angles, and prescription parameters provided minimal improvement in kidney sparing. CONCLUSION: We successfully developed treatment plans that deliver 59.4 Gy to the positive PALNs and 50.4 Gy to the paraaortic region using CT/PET-guided intensity-modulated radiotherapy.

Female↗

A treatment planning study comparing HDR and AGIMRT for cervical cancer.

The customization of brachytherapy dose distributions for gynecologic malignancies is limited by the spatial positioning of the applicators. We tested the hypothesis that applicator-guided intensity modulated radiation therapy (AGIMRT) has the potential to deliver highly conformal dose distributions to cervical tumors, representing improvement over distributions obtained with intracavitary brachytherapy. A commercial three-dimensional (3-D) treatment planning system was used to create plans for ten cervical cancer patients treated at our institution. Dose distributions of conventionally designed high dose rate (HDR) plans were compared against those of AGIMRT. Tumor delineation was based on a previously published binary threshold technique, using image intensity on positron emission tomography (PET) scans. AGIMRT treatment schedules were designed using two fraction sizes: 6.5 Gy, to directly reproduce the HDR fractionation, and 1.8 Gy, to simulate traditional external beam fractionation. The average minimum tumor dose was significantly greater for the AGIMRT dose distributions than for the HDR distributions (64.2 Gy vs 33.6 Gy; p = 0.005). The mean percent tumor volume at the prescription dose was higher for the AGIMRT plans (90.0% vs 58.2%; p = 0.005). Using AGIMRT, the mean percent volume at the tolerance limit was decreased for the bladder (6.1% vs 16.6%; p = 0.047) but increased for the rectum (4.1% vs 2.2%; p = 0.646). Our study suggests that there may be conceptual and dosimetric advantages to replacing HDR with AGIMRT for patients with large-volume cervical tumors. This investigation is being expanded using sequential PET images to model tumor regression and compare brachytherapy and AGIMRT throughout the course of therapy.

Body Burden↗