Dana C Peters

Publications and source records attributed to Dana C Peters.

5 recordsLinked to original sources

Undersampled projection reconstruction for active catheter imaging with adaptable temporal resolution and catheter-only views.

In this study undersampled projection reconstruction (PR) was used for rapid catheter imaging in the heart, employing steady-state free precession (SSFP) contrast. Active catheters and phased-array coils were used for combined imaging of anatomy and catheter position in swine. Real-time imaging of catheter position was performed with relatively high spatial and temporal resolution, providing 2 x 2 x 8 mm spatial resolution and four to eight frames per second. Two interactive features were introduced. The number of projections (Np) was adjusted interactively to trade off imaging speed and artifact reduction, allowing acquisition of high-quality or high-frame-rate images. Thin-slice imaging was performed, with interactive requests for thick-slab projection images of the signal received solely from the active catheter. Briefly toggling on catheter-only projection images was valuable for verifying that the catheter tip was contained within the selected slice, or for locating the catheter when part of it was outside the selected slice.

Animals↗

Centering the projection reconstruction trajectory: reducing gradient delay errors.

The projection reconstruction (PR) trajectory was investigated for the effect of gradient timing delays between the actual and requested start time of each physical gradient. Radial trajectories constructed with delayed gradients miss the center of k-space in an angularly dependent manner, causing effective echo times to vary with projection angle. The gradient timing delays were measured in phantoms, revealing delays on the x, y, and z gradients which differed by as much as 5 micro sec. Using this one-time calibration measurement, the trajectories were corrected for gradient delays by addition of compensatory gradient areas to the prephasers of the logical x and y readout gradients. Effective projection-to-projection echo time variability was reduced to less than 1 micro sec for all imaging orientations. Using corrected trajectories, artifacts were reduced in phantom images and in volunteer studies. This correction should potentiate greater clinical use of the PR trajectory.

Algorithms↗

Catheter-based endomyocardial injection with real-time magnetic resonance imaging.

BACKGROUND: We tested the feasibility of targeted left ventricular (LV) mural injection using real-time MRI (rtMRI). METHODS AND RESULTS: A 1.5T MRI scanner was customized with a fast reconstruction engine, transfemoral guiding catheter-receiver coil (GCC), MRI-compatible needle, and tableside consoles. Commercial real-time imaging software was customized to facilitate catheter navigation and visualization of injections at 4 completely refreshed frames per second. The aorta was traversed and the left ventricular cavity was entered under direct rtMRI guidance. Pigs underwent multiple injections with dilute gadolinium-DTPA. All myocardial segments were readily accessed. The active GCC and the passive Stiletto needle injector were readily visualized. More than 50 endomyocardial injections were performed with the aid of rtMRI; 81% were successful with this first-generation prototype. CONCLUSION: Percutaneous endomyocardial drug delivery is feasible with the aid of rtMRI, which permits precise 3-dimensional localization of injection within the LV wall.

Animals↗

Multislice first-pass cardiac perfusion MRI: validation in a model of myocardial infarction.

The purpose of this study was to validate a first-pass MRI method for imaging myocardial perfusion with multislice coverage and relatively small analyzable regions of interest (ROIs). A fast gradient-echo (FGRE) sequence with an echo-train (ET) readout was used to achieve multislice coverage, and a high dose of a contrast agent (CA) was used to achieve a high signal-to-noise ratio (SNR). Dogs (N = 6) were studied 1 day after reperfused myocardial infarction, and fluorescent microspheres were used as a standard for perfusion. First-pass MRI correlated well vs. microsphere flow, achieving mean R values of 0.87 (range = 0.82-0.93), 0.71 (range = 0.46-0.85), and 0.72 (range = 0.49-0.95) for subendocardial ROIs, transmural ROIs, and the endocardial-epicardial ratio, respectively. Additionally, analysis of myocardial time-intensity curves (TICs) indicated that 15.8 +/- 6 sectors, corresponding to 260 microl of endocardium, can be analyzed (R(2) > 0.95).

Animals↗

High-resolution MRI of cardiac function with projection reconstruction and steady-state free precession.

The purpose of this study was to investigate the trabecular structure of the endocardial wall of the living human heart, and the effect of that structure on the measurement of myocardial function using MRI. High-resolution MR images (0.8 x 0.8 x 8 mm voxels) of cardiac function were obtained in five volunteers using a combination of undersampled projection reconstruction (PR) and steady-state free precession (SSFP) contrast in ECG-gated breath-held scans. These images provide movies of cardiac function with new levels of endocardial detail. The trabecular-papillary muscle complex, consisting of a mixture of blood and endocardial structures, is measured to constitute as much as 50% of the myocardial wall in some sectors. Myocardial wall strain measurements derived from tagged MR images show correlation between regions of trabeculae and papillary muscles and regions of high strain, leading to an overestimation of function in the lateral wall.

Electrocardiography↗