Search PubMed⌕ Search

Biomedical subjects

Dan Stoianovici

Publications and source records attributed to Dan Stoianovici.

21 records · Page 2Linked to original sources

Technology improvements for image-guided and minimally invasive spine procedures.

This paper reports on technology developments aimed at improving the state of the art for image-guided minimally invasive spine procedures. Back pain is a major health problem with serious economic consequences. Minimally invasive procedures to treat back pain are rapidly growing in popularity due to improvements in technique and the substantially reduced trauma to the patient versus open spinal surgery. Image guidance is an enabling technology for minimally invasive procedures, but technical problems remain that may limit the wider applicability of these techniques. The paper begins with a discussion of low back pain and the potential shortcomings of open back surgery. The advantages of minimally invasive procedures are enumerated, followed by a list of technical problems that must be overcome to enable the more widespread dissemination of these techniques. The technical problems include improved intraoperative imaging, fusion of images from multiple modalities, the visualization of oblique paths, percutaneous spine tracking, mechanical instrument guidance, and software architectures for technology integration. Technical developments to address some of these problems are discussed next. The discussion includes intraoperative computerized tomography (CT) imaging, magnetic resonance imaging (MRI)/CT image registration, three-dimensional (3-D) visualization, optical localization, and robotics for percutaneous instrument placement. Finally, the paper concludes by presenting several representative clinical applications: biopsy, vertebroplasty, nerve and facet blocks, and shunt placement. The program presented here is a first step to developing the physician-assist systems of the future, which will incorporate visualization, tracking, and robotics to enable the precision placement and manipulation of instruments with minimal trauma to the patient.

Back Pain↗

Robotically driven interventions: a method of using CT fluoroscopy without radiation exposure to the physician.

Radiation exposure to physicians' hands during interventional procedures with computed tomography (CT) fluoroscopic guidance may be high. A robot was developed that could hold, orient, and advance a needle, with CT fluoroscopic guidance. This robot could be either computer or joystick controlled. Twenty-three robotically guided percutaneous interventions were performed without complication. Physician radiation exposure was negligible during the CT fluoroscopy-guided procedures.

Aged↗

Robotically assisted prostate brachytherapy with transrectal ultrasound guidance--Phantom experiments.

PURPOSE: To report the preliminary experimental results obtained with a robot-assisted transrectal ultrasound (TRUS)-guided prostate brachytherapy system. METHODS AND MATERIALS: The system consists of a TRUS unit, a spatially coregistered needle insertion robot, and an FDA-approved treatment planning and image-registered implant system. The robot receives each entry/target coordinate pair of the implant plan, inserts a preloaded needle, and then the seeds are deposited. The needles/sources are tracked in TRUS, thus allowing the plan to be updated as the procedure progresses. RESULTS: The first insertion attempt was recorded for each needle, without adjustment. All clinically relevant locations were reached in a prostate phantom. Nonparallel and parallel needle trajectories were demonstrated. Based on TRUS, the average transverse placement error was 2 mm (worst case 2.5 mm, 80% less than 2 mm), and the average sagittal error was 2.5 mm (worst case 5.0 mm, 70% less than 2.5 mm). CONCLUSIONS: The concept and technical viability of robot-assisted brachytherapy were demonstrated in phantoms. The kinematically decoupled robotic assistant device is inherently safe. Overall performance was promising, but further optimization is necessary to prove the possibility of improved dosimetry.

Brachytherapy↗