Search PubMed⌕ Search

Biomedical subjects

Daisuke Takenaka

Publications and source records attributed to Daisuke Takenaka.

At least 19 recordsLinked to original sources

Assessment of bolus injection protocol with appropriate concentration for quantitative assessment of pulmonary perfusion by dynamic contrast-enhanced MR imaging.

PURPOSE: To determine the appropriate concentration for quantitative assessment of dynamic contrast-enhanced pulmonary MR imaging. MATERIALS AND METHODS: A total of 40 consecutive patients with small bronchioalveolar carcinoma underwent perfusion single-photon emission tomography (SPECT) and three-dimensional (3D) dynamic MR imaging with a 3D radiofrequency spoiled gradient-echo sequence. In each patient, 5 mL of contrast media with 0.1, 0.3, and 0.5 mmol/mL were administered at a rate of 5 mL/second. All patients were divided into two groups (<70 kg and > or =70 kg) for assessment of appropriate concentration to quantitatively assess regional perfusion parameter in routine clinical practice. Pulmonary blood flow (PBF) in each protocol was calculated from a signal intensity (SI)-time course curve. Differences and limits of agreement of PBF between dynamic MR imaging (PBF(MR)) using three different concentrations and perfusion SPECT (PBF(SPECT)) were statistically compared in both patient groups. RESULTS: PBF(MR) using 0.3 mmol/mL in the <70-kg group and 0.5 mmol/mL in the > or =70-kg group showed no significant difference compared with PBF(SPECT) (P > 0.05). Limits of agreements in 0.3 mmol/mL in the <70-kg group and 0.5 mmol/mL in the > or =70-kg group were smaller than those of the other concentrations and small enough for clinical purposes. CONCLUSION: Appropriate concentrations provide accurate and reproducible assessments of regional pulmonary perfusion parameters on 3D dynamic MR perfusion imaging. We suggest using 5 mL of contrast media with 0.3 mmol/mL for patients weighing less than 70 kg and 0.5 mmol/mL for patients weighing 70 kg or more.

Aged↗

Anticoagulant-induced pseudothrombocytopenia occurring after transcatheter arterial embolization for hepatocellular carcinoma.

Pseudothrombocytopenia (PTCP) is the in vitro phenomenon of anticoagulant-activated platelet agglutination that results in spuriously low platelet counts. We report the case of a 65-year-old man with EDTA- and sodium citrate-dependent PTCP occurring after transcatheter arterial embolization (TAE) for hepatocellular carcinoma (HCC) due to hepatitis C cirrhosis. Invasion of the portal and hepatic veins by HCC formed severe trans-tumoral arterio-venous shunts that were effectively treated by TAE. Two days after the therapy, PTCP was seen on blood count and continued for 4 months. The patient received unnecessary treatment for disseminated intravascular coagulation (DIC) until the diagnosis of PTCP was established. PTCP is a rare complication but should be considered after TAE for HCC; lack of recognition may lead the physician to misdiagnosis and patient mismanagement.

Aged↗

Oxygen-enhanced MR imaging: correlation with postsurgical lung function in patients with lung cancer.

PURPOSE: To prospectively determine if lung function as assessed with oxygen-enhanced magnetic resonance (MR) imaging correlates with postsurgical lung function in patients with lung cancer, as compared with quantitative and qualitative findings of computed tomography (CT) and scintigraphy. MATERIALS AND METHODS: Study received institutional review board approval, and informed patient consent was obtained. Thirty consecutive patients (16 men and 14 women, aged 44-81 years; mean age, 65 years) considered candidates for lung resection underwent oxygen-enhanced MR imaging, CT, perfusion scintigraphy, and measurement of forced expiratory volume in 1 second (FEV1). A respiratory-synchronized inversion-recovery half-Fourier single-shot turbo spin-echo MR sequence was used for data acquisition. Correlation of postsurgical lung function (postsurgical FEV1) as determined with oxygen-enhanced MR imaging (FEV1MR), quantitative assessment with CT (FEV1Quant), qualitative assessment with CT (FEV1Qual), and perfusion scintigraphy (FEV1PS) was conducted with actual postsurgical FEV1, and the limits of agreement of each were determined with Bland-Altman analysis. RESULTS: Correlation between postsurgical FEV1MR and actual postsurgical FEV1 values was excellent (r2= 0.81, P < .001); it was better than that of FEV1Qual (r2= 0.76) and FEV1PS (r2= 0.77) and similar to that of FEV1Quant (r2= 0.81) values. The limits of agreement of FEV1MR were between -9.9% and 10.9%. CONCLUSION: Oxygen-enhanced MR imaging can be used to predict posturgical lung function in patients with lung cancer, similar to quantitative CT.

Adult↗

Prognostic value of dynamic MR imaging for non-small-cell lung cancer patients after chemoradiotherapy.

PURPOSE: To determine the prognostic value of dynamic MRI for non-small-cell lung cancer (NSCLC) patients after chemoradiotherapy. MATERIALS AND METHODS: A total of 114 consecutive patients with NSCLC underwent dynamic MRI after chemoradiotherapy. The patients were divided into two groups (local control (n=22) and local failure (n=92)) according to the presence of local recurrence. From the signal intensity-time course curve in each subject, the maximum relative enhancement ratio and slope of enhancement were calculated, and compared between two groups by Student's t-test. To determine the feasible threshold values of both MR indexes for group differentiation, ROC-based positive tests were performed. Finally, the Kaplan-Meier survival curves of each group divided by the adapted threshold value were compared by log-rank test. RESULTS: The maximum relative enhancement ratio and the slope of enhancement in the local control group were significantly lower than those in the local failure group (P<0.05). Using 0.08/sec as the threshold value of the slope of enhancement, the sensitivity and specificity for differentiation between the two groups were 90.9% and 91.3%, respectively. When the slope of enhancement was adopted for estimation of prognosis after therapy, the mean survival period of the slope of enhancement 0.08/sec (P<0.0001). CONCLUSION: Dynamic MRI has potential prognostic value for NSCLC patients after chemoradiotherapy.

Adult↗

Thin-section multiplanar reformats from multidetector-row CT data: utility for assessment of regional tumor extent in non-small cell lung cancer.

PURPOSE: To determine the clinical utility of thin-section multiplanar reformats (MPRs) from multidetector-row CT (MDCT) data sets for assessing the extent of regional tumors in non-small cell lung cancer (NSCLC) patients. MATERIALS AND METHODS: Sixty consecutive NSCLC patients, who were considered candidates for surgical treatment, underwent contrast-enhanced MDCT examinations, surgical resection and pathological examinations. All MDCT examinations were performed with a 4-detector row computed tomography (CT). From each raw CT data set, 5mm section thickness CT images (routine CT), 1.25 mm section thickness CT images (thin-section CT) and 1.25 mm section thickness sagittal (thin-section sagittal MPR) and coronal images (thin-section coronal MPR) were reconstructed. A 4-point visual score was used to assess mediastinal, interlobar and chest wall invasions on each image set. For assessment of utility in routine clinical practice, mean reading times for each image set were compared by means of Fisher's protected least significant difference (PLSD) test. A receiver operator characteristic (ROC) analysis was performed to determine the diagnostic capability of each of the image data sets. Finally, sensitivity, specificity and accuracy of the reconstructed images were compared by McNemar test. RESULTS: Mean reading times for thin-section sagittal and coronal MPRs were significantly shorter than those for routine CT and thin-section CT (p<0.05). Areas under the curve (Azs) showing interlobar invasion on thin-section sagittal and coronal MPRs were significantly larger than that on routine CT (p=0.03), and the Az on thin-section sagittal MPR was also significantly larger than that on routine CT (p=0.02). Accuracy of chest wall invasion by thin-section sagittal MPR was significantly higher than that by routine CT (p=0.04). CONCLUSION: Thin-section multiplanar reformats from multidetector-row CT data sets are useful for assessing the extent of regional tumors in non-small cell lung cancer patients.

Adult↗

Quantitative assessment of regional pulmonary perfusion in the entire lung using three-dimensional ultrafast dynamic contrast-enhanced magnetic resonance imaging: Preliminary experience in 40 subjects.

PURPOSE: To assess regional differences in quantitative pulmonary perfusion parameters, i.e., pulmonary blood flow (PBF), mean transit time (MTT), and pulmonary blood volume (PBV) in the entire lung on a pixel-by-pixel basis in normal volunteers and pulmonary hypertension patients. MATERIALS AND METHODS: Three-dimensional ultrafast dynamic contrast-enhanced MR imaging was performed in 15 normal volunteers and 25 patients with pulmonary hypertension. From the signal intensity-time course curves, PBF, MTT and PBV maps were generated using deconvolution analysis, indicator dilution theories, and the central volume principle, on a pixel-by-pixel basis. From pulmonary perfusion parameter maps of normal volunteers and pulmonary hypertension patients, regional PBF, MTT, and PBV were statistically evaluated. RESULTS: Regional PBF, MTT, and PBV showed significant differences in the gravitational and isogravitational directions (P < 0.05). The quantitative pulmonary perfusion parameter maps demonstrated significant differences between normal volunteers and pulmonary hypertension patients (P < 0.05). CONCLUSION: Three-dimensional ultrafast dynamic contrast-enhanced MR imaging is feasible for the assessment of regional quantitative pulmonary perfusion parameters in the entire lung on a pixel-by-pixel basis in normal volunteers and pulmonary hypertension patients.

Adult↗

Dynamic MR imaging: value of differentiating subtypes of peripheral small adenocarcinoma of the lung.

PURPOSE: To determine the utility of dynamic magnetic resonance imaging (MRI) in the differential subtyping of small adenocarcinomas of the lung. MATERIALS AND METHODS: Twenty-nine pathologically diagnosed peripheral adenocarcinomas (less than 20 mm in diameter) underwent dynamic contrast-enhanced MRI. Maximum relative enhancement ratio, slope of enhancement, and corrected start time of enhancement were calculated from signal intensity-time curve of pulmonary lesion for each subject, and were statistically compared among bronchioloalveolar carcinoma (BAC) group (7 cases), mixed BAC group (10 cases), and adenocarcinoma group (12 cases). RESULTS: Maximum relative enhancement ratio (P<0.001) and slope of enhancement (P<0.001) of BAC group were significantly higher than those of mixed BAC and adenocarcinoma groups. Start times of BAC group were significantly earlier than those of mixed BAC (P=0.0001) and adenocarcinoma groups (P<0.0001). Adapting the thresholds values of MR indexes from the positive tests, sensitivity, specificity, positive predictive value, negative predictive value and accuracy for differentiating BAC from other subtypes were 85.7, 100.0, 100.0, 95.7, and 96.6%, respectively. CONCLUSIONS: Dynamic MRI is useful for differentiating subtypes of small peripheral adenocarcinoma.

Adenocarcinoma↗

Centrically reordered inversion recovery half-Fourier single-shot turbo spin-echo sequence: improvement of the image quality of oxygen-enhanced MRI.

PURPOSE: The purpose of the study presented here was to determine the improvement in image quality of oxygen-enhanced magnetic resonance (MR) subtraction imaging obtained with a centrically reordered inversion recovery half-Fourier single-shot turbo spin-echo (c-IR-HASTE) sequence compared with that obtained with a conventional sequentially reordered inversion recovery single-shot HASTE (s-IR-HASTE) sequence for pulmonary imaging. MATERIALS AND METHODS: Oxygen-enhanced MR imaging using a 1.5 T whole body scanner was performed on 12 healthy, non-smoking volunteers. Oxygen-enhanced MR images were obtained with the coronal two-dimensional (2D) c-IR-HASTE sequence and 2D s-IR-HASTE sequence combined with respiratory triggering. For a 256x256 matrix, 132 phase-encoding steps were acquired including four steps for phase correction. Inter-echo spacing for each sequence was 4.0 ms. The effective echo time (TE) for c-IR-HASTE was 4.0 ms, and 16 ms for s-IR-HASTE. The inversion time (TI) was 900 ms. To determine the improvement in oxygen-enhanced MR subtraction imaging by c-IR-HASTE, CNRs of subtraction image, overall image quality, and image degradation of the c-IR-HASTE and s-IR-HASTE techniques were statistically compared. RESULTS: CNR, overall image quality, and image degradation of c-IR-HASTE images showed significant improvement compared to those s-IR-HASTE images (P<0.05). CONCLUSION: Centrically reordered inversion recovery half-Fourier single-shot turbo spin-echo (c-IR-HASTE) sequence enhanced the signal from the lung and improved the image quality of oxygen-enhanced MR subtraction imaging.

Adult↗

Transthoracic CT-guided biopsy with multiplanar reconstruction image improves diagnostic accuracy of solitary pulmonary nodules.

OBJECTIVE: To evaluate the utility of multiplanar reconstruction (MPR) image for CT-guided biopsy and determine factors of influencing diagnostic accuracy and the pneumothorax rate. MATERIALS AND METHODS: 390 patients with 396 pulmonary nodules underwent transthoracic CT-guided aspiration biopsy (TNAB) and transthoracic CT-guided cutting needle core biopsy (TCNB) as follows: 250 solitary pulmonary nodules (SPNs) underwent conventional CT-guided biopsy (conventional method), 81 underwent CT-fluoroscopic biopsy (CT-fluoroscopic method) and 65 underwent conventional CT-guided biopsy in combination with MPR image (MPR method). Success rate, overall diagnostic accuracy, pneumothorax rate and total procedure time were compared in each method. Factors affecting diagnostic accuracy and pneumothorax rate of CT-guided biopsy were statistically evaluated. RESULTS: Success rates (TNAB: 100.0%, TCNB: 100.0%) and overall diagnostic accuracies (TNAB: 96.9%, TCNB: 97.0%) of MPR were significantly higher than those using the conventional method (TNAB: 87.6 and 82.4%, TCNB: 86.3 and 81.3%) (P < 0.05). Diagnostic accuracy were influenced by biopsy method, lesion size, and needle path length (P < 0.05). Pneumothorax rate was influenced by pathological diagnostic method, lesion size, number of punctures and FEV1.0% (P < 0.05). CONCLUSION: The use of MPR for CT-guided lung biopsy is useful for improving diagnostic accuracy with no significant increase in pneumothorax rate or total procedure time.

Adolescent↗

Metastases in mediastinal and hilar lymph nodes in patients with non-small cell lung cancer: quantitative and qualitative assessment with STIR turbo spin-echo MR imaging.

PURPOSE: To evaluate short inversion time inversion-recovery (STIR) turbo spin-echo (TSE) magnetic resonance (MR) imaging for detection of metastases in lymph nodes by using quantitative and qualitative analyses. MATERIALS AND METHODS: One hundred ten patients (68 men and 42 women) with non-small cell lung cancer who ranged in age from 36 to 82 years (mean age, 64 years) were examined with respiratory-triggered STIR TSE MR imaging. Ratios of signal intensity in a lymph node to that in a 0.9% saline phantom (lymph node-saline ratios [LSRs]) for all lymph nodes were classified into three groups according to nodal short-axis diameter. LSRs of each group were compared by using pathologic diagnosis as the standard of reference. For quantitative analysis, the LSR threshold value for a positive test was determined on a per-node basis and tested for ability to enable a correct diagnosis on a per-patient basis. For qualitative analysis, signal intensities of lymph nodes were assessed by using a five-point visual scoring system. Results of quantitative and qualitative analyses were compared on a per-patient basis with McNemar testing. RESULTS: In 110 patients, 92 of 802 lymph nodes were pathologically diagnosed as containing metastases, while 710 lymph nodes did not contain metastases. Mean LSR in the lymph node group with metastasis was higher than that in the group without metastasis (P <.05). When an LSR of 0.6 was used as the positive-test threshold at quantitative analysis, sensitivity was 93% (37 of 40 patients) and specificity was 87% (61 of 70 patients) on a per-patient basis. With a score of 4 as the positive-test threshold at qualitative analysis, sensitivity was 88% (35 of 40 patients) and specificity was 86% (60 of 70 patients) on a per-patient basis. There was no significant difference (P >.05) between results of quantitative and those of qualitative analysis. CONCLUSION: Quantitative and qualitative analyses of STIR TSE MR images enable differentiation of lymph nodes with metastasis from those without. Qualitative analysis can substitute for quantitative analysis of STIR TSE MR imaging data.

Adult↗

Dynamic perfusion MRI versus perfusion scintigraphy: prediction of postoperative lung function in patients with lung cancer.

OBJECTIVE: The purpose of this study was to determine the capability of dynamic perfusion MRI as an alternative to pulmonary perfusion scintigraphy for prediction of postoperative lung function in patients with lung cancer. SUBJECTS AND METHODS. Sixty patients with lung cancer (35 men, 25 women) underwent dynamic perfusion MRI, perfusion scintigraphy, and preoperative and postoperative pulmonary function tests (forced expiratory volume in 1 sec [FEV(1)]). Perfusion MRIs were obtained with a 3D turbo field-echo sequence (TR/TE, 2.7/0.6; flip angle, 40 degrees; matrix, 128 x 96) using a 1.5-T scanner. Regional blood flow was calculated from the signal intensity-time curves after bolus injection of contrast medium on MRI (Q(MRI)) and uptake ratios of radioisotope on perfusion scintigraphy (Q(PS)). Postoperative lung functions predicted by MRI (FEV(1,MRI)) and perfusion scintigraphy (FEV(1,PS)) were calculated from preoperative FEV(1) and regional Qs. To determine the capability of MRI as an alternative to scintigraphy, we evaluated correlations and the limits of agreement between predicted FEV(1,MRI) and postoperative FEV(1) and between predicted FEV(1,PS) and postoperative FEV(1). RESULTS: The correlation coefficient of postoperative FEV(1) with FEV(1,MRI) (r = 0.93, p < 0.0001) was better than that with FEV(1,PS) (r = 0.89, p < 0.0001). The limits of agreement between postoperative FEV(1) and predicted FEV(1,MRI) (0.9% +/- 10.4%) were smaller than those between postoperative FEV(1) and predicted FEV(1,PS) (2.1% +/- 13.2%). CONCLUSION: Dynamic perfusion MRI is a feasible alternative to pulmonary perfusion scintigraphy for predicting postoperative lung function in patients with lung cancer.

Adult↗

MR angiography with sensitivity encoding (SENSE) for suspected pulmonary embolism: comparison with MDCT and ventilation-perfusion scintigraphy.

OBJECTIVE: The aim of our study was to determine the utility of time-resolved contrast-enhanced MR angiography combined with sensitivity encoding (SENSE) for patients with pulmonary embolism. SUBJECTS AND METHODS. Forty-eight consecutive patients (26 men and 22 women; age range, 27-73 years; mean age, 55 years) with suspected pulmonary embolism underwent chest radiography, contrast-enhanced MDCT, MR angiography with SENSE, ventilation-perfusion scintigraphy, and pulmonary angiography. MR angiography with SENSE was performed using IV administration of gadolinium contrast medium with a 3D turbo field-echo pulse sequence (TR/TE, 4.0/1.2; flip angle, 30 degrees ) on a 1.5-T scanner. Capabilities of diagnosing pulmonary embolism using MR angiography (data set A), contrast-enhanced MDCT (data set B), contrast-enhanced MDCT with MR angiography (data set C), ventilation-perfusion scintigraphy (data set D), and contrast-enhanced MDCT with ventilation-perfusion scintigraphy (data set E) were determined by receiver operating characteristic analysis, using the results of pulmonary angiography as the reference standard. The diagnostic capability of each data set was analyzed on a per-vascular zone and a per-patient basis with the McNemar test. RESULTS: Sensitivity and specificity of data set A were 83% and 97%, respectively, on a per-vascular zone basis and 92% and 94%, respectively, on a per-patient basis. Specificity and accuracy of data set A were significantly higher than those of data set D on a per-patient basis (p < 0.05). CONCLUSION: Time-resolved MR angiography with SENSE is effective for the diagnosis of pulmonary embolism.

Contrast Media↗

Three-dimensional treatment planning using electrocardiographically gated multi-detector row CT.

PURPOSE: Information concerning the amount and nature of target motion is essential for the determination of internal margin size. However, there are few published reports outlining the motion with heart and aortic pulsation. We introduce a method for three-dimensional radiation treatment planning (3D-RTP) by using electrocardiographically (ECG) gated spiral scanning with a four-section CT system. We describe a new approach to visualize internal organ motion resulting from cardiac motion with ECG gated multidetector row CT. MATERIALS AND METHODS: Five patients with lung or liver tumors were studied with a multidetector row CT system under shallow inspiration breath-holding. With retrospective ECG gating, only data acquired within a predefined interval of the cardiac cycle are used for image reconstruction. All reconstructed image data at diastolic and systolic phases of the cardiac cycle were transferred to the 3D-RTP system. The shift of the internal organs between the cardiac cycles was evaluated. RESULTS: Cardiac contraction influences anterior thorax, pulmonary peripheral vessels, and liver position, in addition to locations near the heart. Apparent movements more than 5 mm between diastolic and systolic phases were observed in the left ventricle, right atrium, and superior vena cava. Two-phase imaging was useful for showing the movement of internal organs during cardiac contraction under breath-holding. CONCLUSIONS: Spatial information using ECG-gated CT has the potential to determine the planning target volume of moving lung and liver tumors more precisely than conventional CT planning.

Computer Systems↗

Time-resolved contrast-enhanced pulmonary MR angiography using sensitivity encoding (SENSE).

PURPOSE: To evaluate the relationship between gadolinium concentration and signal-to-noise ratio (SNR) on sensitivity encoding (SENSE) images, and determine the appropriate bolus injection protocol for visualizing pulmonary circulation. MATERIALS AND METHODS: Eighteen different gadolinium concentration phantoms (0, 0.01, 0.05, 0.1, 0.2, 0.4, 0.6, 0.8, 1.0, 1.2, 1.5, 2.0, 5.0, 10.0, 20.0, 30.0, 50.0, and 100.0 mmol/L) were analyzed to determine the relationship between gadolinium concentration and SNR on SENSE images in a phantom study. In an in vivo study, 3 mL (protocol A) or 6 mL (protocol B) of Gd-DTPA BMA at 3 mL/second, and 5 mL of Gd-DTPA BMA at 5 mL/second (protocol C) were administered to eight normal volunteers for contrast-enhanced (CE) pulmonary MR angiography (MRA) with SENSE. The peak SNRs of pulmonary parenchyma and the difference in SNR between pulmonary artery (PA) and pulmonary vein (PV) at peak SNR in the PA were statistically evaluated. RESULTS: For each flip angle at each gadolinium concentration, the SNRs and contrast-to-noise ratios (CNRs) of the SENSE images were significantly lower than those acquired with a nonparallel imaging technique (P < 0.05). The peak SNR of the pulmonary parenchyma, and differences in SNR between the PA and PV at the peak SNR of the PA obtained with a 5-mL/second bolus injection protocol were found to be significantly higher than those obtained with other protocols (P < 0.05). CONCLUSION: 3D-CE-MRA using SENSE demonstrated linearity between gadolinium concentration and SNR, and resulted in MRA with high spatial and temporal resolution with the aid of a sharp bolus injection protocol.

Adult↗

CT-guided transthoracic needle aspiration biopsy of small (< or = 20 mm) solitary pulmonary nodules.

OBJECTIVE: The purpose of our study was to determine the diagnostic accuracy and to analyze the factors influencing the diagnostic accuracy and incidences of pneumothorax and chest tube insertion rates for percutaneous CT-guided needle biopsy of small (< or = 20 mm) solitary pulmonary nodules. SUBJECTS AND METHODS: One hundred sixty-two patients with 162 small solitary pulmonary nodules underwent CT-guided transthoracic needle aspiration biopsy. The overall diagnostic accuracy, pneumothorax rate, and chest tube insertion rate were calculated. Factors influencing the diagnostic accuracy and pneumothorax rate were statistically evaluated. Influencing factors, diagnostic accuracies, pneumothorax rates, and chest tube insertion rates were statistically compared. RESULTS: Overall diagnostic accuracy, pneumothorax rate, and chest tube insertion rate were 77.2%, 28.4%, and 2.5%, respectively. Diagnostic accuracy was significantly affected by length of needle path and lesion size (p < 0.05). The pneumothorax rate was significantly affected by the percentage of predicted forced expiratory volume in 1 sec, the number of punctures, and the needle path length (p < 0.05). The chest tube insertion rate was significantly affected by the number of punctures (p < 0.05). For diagnostic accuracy, needle path lengths of 40 mm or less and lesion sizes greater than 10 mm were significantly more accurate than other factors (p < 0.05). For pneumothorax rates, a percentage of predicted forced expiratory volume in 1 sec of greater than 70%, a single puncture, and a needle path length of 40 mm or less were significantly lower than other factors (p < 0.05). CONCLUSION: CT-guided transthoracic needle aspiration biopsy is a useful diagnostic tool for small solitary pulmonary nodules smaller than 20 mm in diameter. The diagnostic accuracy is significantly improved for large (> 10 mm) lesion size and short (< or = 40 mm) needle path length.

Adult↗

Dynamic oxygen-enhanced MRI reflects diffusing capacity of the lung.

The purpose of this study was to demonstrate the feasibility of dynamic oxygen-enhanced MRI in a clinical setting. We hypothesized that dynamic oxygen enhancement can reflect the regional diffusing capacity of the lung. Ten patients with pulmonary emphysema and seven healthy volunteers were examined with a respiratory-synchronized inversion recovery single-shot turbo spin-echo sequence (TR = 3200-5000 ms, TE = 16 ms, TI = 720 ms, ETS = 4 ms) following 100% oxygen inhalation, using a 1.5 T whole-body scanner. Maximum mean relative enhancement ratios calculated by averaging six defined regions of interest (ROIs) in both lungs were statistically compared between healthy volunteers and patients, and were correlated with diffusing lung capacity (%DL(CO)). In patients with pulmonary emphysema, maximum mean relative enhancement ratios were significantly decreased compared to those in healthy volunteers (P = 0.0008). Maximum mean relative enhancement ratio had excellent correlation with % DL(C0) (r(2) = 0.83). Dynamic oxygen-enhanced MRI may reflect the diffusing capacity of the lung; therefore, imaging of oxygen enhancement with MRI may provide maps of the diffusing capacity.

Adult↗

Contrast-enhanced MR perfusion imaging and MR angiography: utility for management of pulmonary arteriovenous malformations for embolotherapy.

OBJECTIVE: The purpose of this study was to assess the capability of MR perfusion imaging and angiography (MRA) for management of pulmonary arteriovenous malformation (PAVM). METHODS AND PATIENTS: Eight patients, having 15 PAVMs underwent pulmonary angiography (PAG), CT, MR perfusion imaging and MRA. For the pretherapeutic management, MRA was compared with PAG and CT regarding detectability and diameter of vasculature. For post-therapeutic management, the change in size of aneurysmal sac, any residual contrast-enhancement and the blood supply within the sac were evaluated. RESULTS: All PAVMs with aneurysmal sac, feeding artery and draining vein diameters of equal to or more than 3 mm, were identified and measured with similar results by all modalities. On follow-up studies, 7 (58.4%) out of 12 treated PAVMs showed a decrease in size and residual contrast-enhancement. The residual contrast-enhancement was considered as bronchial artery-to-pulmonary artery collateral flow by MR perfusion imaging. CONCLUSION: MR perfusion imaging and MRangiography are useful for management of PAVMs over 3 mm in diameter.

Adolescent↗

Differentiation of metastatic versus non-metastatic mediastinal lymph nodes in patients with non-small cell lung cancer using respiratory-triggered short inversion time inversion recovery (STIR) turbo spin-echo MR imaging.

OBJECTIVES: To differentiate between metastatic and non-metastatic lymph nodes in patients with non-small cell lung cancer using respiratory-triggered short inversion time inversion recovery (STIR) turbo spin-echo (SE) MR imaging. METHODS AND PATIENTS: One hundred and forty mediastinal lymph nodes were detected in 25 patients with non-small cell lung cancer who underwent respiratory-triggered STIR turbo SE imaging. Ratios of signal intensity of lymph nodes to 0.9% saline phantoms (lymph node-saline ratio) were compared by Student's t-test using the pathological diagnosis as the gold standard. The threshold value of the lymph node-saline ratio was determined for a positive test, and tested for its capability to provide a differential diagnosis. RESULTS: One hundred and forty lymph nodes were diagnosed and classified into two groups: metastatic lymph node (n=21) and non-metastatic lymph node (n=119). The mean lymph node-saline ratio in the non-metastatic lymph node group (0.42+/-0.01; mean+/-standard error) was significantly lower than that of the metastatic lymph node group (0.77+/-0.02, P<0.0001). When 0.6 was adapted as the threshold for a positive test, sensitivity, specificity, and accuracy for differentiating metastatic lymph node from non-metastatic lymph node per lymph nodes were 100, 96, and 96%, and sensitivity, specificity, and accuracy for differentiating metastatic lymph node from non-metastatic lymph node per patients were 100, 75, and 88%, respectively. CONCLUSIONS: Both metastatic and non-metastatic lymph nodes in patients with non-small cell lung cancer were well differentiated using respiratory-triggered STIR turbo SE imaging.

Adult↗