Cardiovascular changes during deep breath-hold dives in a pressure chamber.

Electrocardiogram, cardiac output, and blood lactate accumulation were recorded in three elite breath-hold divers diving to 40-55 m in a pressure chamber in thermoneutral (35 degrees C) or cool (25 degrees C) water. In two of the divers, invasive recordings of arterial blood pressure were also obtained during dives to 50 m in cool water. Bradycardia during the dives was more pronounced and developed more rapidly in the cool water, with heart rates dropping to 20-30 beats/min. Arrhythmias occurred, particularly during the dives in cool water, when they were often more frequent than sinus beats. Because of bradycardia, cardiac output decreased during the dives, especially in cool water (to <3 l/min in 2 of the divers). Arterial blood pressure increased dramatically, reaching values as high as 280/200 and 290/150 mmHg in the two divers, respectively. This hypertension was secondary to peripheral vasoconstriction, which also led to anaerobic metabolism, reflected in increased blood lactate concentration. The diving response of these divers resembles the one described for diving animals, although the presence of arrhythmias and large increases in blood pressure indicate a less perfect adaptation in humans.

Adult↗

Cerebral blood flow velocity and cranial fluid volume decrease during +Gz acceleration.

Cerebral blood flow (CBF) velocity and cranial fluid volume, which is defined as the total volume of intra- and extracranial fluid, were measured using transcranial Doppler ultrasonography and rheoencephalography, respectively, in humans during graded increase of +Gz acceleration (onset rate: 0.1 G/s) without straining maneuvers. Gz acceleration was terminated when subjects' vision decreased to an angle of less than or equal to 60 degrees, which was defined as the physiological end point. In five subjects, mean CBF velocity decreased 48% from a baseline value of 59.4 +/- 11.2 cm/s to 31.0 +/- 5.6 cm/s (p<0.01) with initial loss of peripheral vision at 5.7 +/- 0.9 Gz. On the other hand, systolic CBF velocity did not change significantly during increasing +Gz acceleration. Cranial impedance, which is proportional to loss of cranial fluid volume, increased by 2.0 +/- 0.8% above the baseline value at the physiological end point (p<0.05). Both the decrease of CBF velocity and the increase of cranial impedance correlated significantly with Gz. These results suggest that +Gz acceleration without straining maneuvers decreases CBF velocity to half normal and probably causes a caudal fluid shift from both intra- and extracranial tissues.

Acceleration↗