Search PubMedSearch

Biomedical subjects

D Walb

Publications and source records attributed to D Walb.

17 recordsLinked to original sources

Low-molecular-weight protein-permeable cuprammonium rayon haemofilter.

Searching for a dialyser membrane with a cut-off similar to that of the human glomerulus, a modified cuprammonium rayon (AM-75-UP) and a polyacrylonitrile (PAN-15-DX) haemofilter were tested in vivo for the ability to eliminate substances of a molecular weight (MW) of 10-65 kilodaltons (kDa). Endogenous marker substances of a defined MW (beta-2-microglobulin 11.8 kDa; retinol binding protein 21 kDa; alpha-1-microglobulin 26.7 kDa; alpha-1-glycoprotein 41 kDa; alpha-1-antitrypsin 54 kDa; albumin 66.3 kDa) were measured by laser nephelometry or immunosorbent assay; sieving coefficients (SC) and protein elimination (PE) per 20 l haemofiltration were calculated for each low-MW protein. The PAN haemofilter shows elimination characteristics comparable to those of earlier tested haemofilters (polysulphone, AN69, cellulose triacetate) with a sharp cut-off in the MW range of 10-15 kDa. The cuprammonium rayon haemofilter is permeable for proteins with a higher MW; especially for alpha-1-microglobulin a relevant removal (SC 0.2; PE 0.56 g/20 l) was established. This membrane has a cut-off more similar to that of the human glomerulus; but far from the demanded quality with a relevant removal of substances in the MW range up to 60 kDa. Calculated albumin loss (2.4 +/- 0.2 g/20 l) seems to be tolerable for stable haemodialysis patients.

Acrylic Resins

Inappropriate secretion of antidiuretic hormone, polydipsia and hypothalamic calcifications.

We studied a 41 year old patient who had pathologic fluid intake of 10 1/day together with syndrome of inappropriate antidiuretic hormone. Imaging studies revealed a lesion of the anterior wall of the third cerebral ventricle. A review of relevant literature indicated several different disturbances by which alterations of thirst, vasopressin-secretion and abnormalities of anterior third ventricle may be associated. The present case presents an unusual and potentially dangerous combination in this spectrum of changes.

Adult

Allergy to dialysis materials.

One hundred and six unselected patients were screened for allergic symptoms, specific IgE against ethylene oxide (ETO), isocyanates (ISO), formaldehyde (FA), phthalates (PHT), total IgE and eosinophil count. Complement activation was measured during cellulosic dialysis in atopic patients and in a control group. Sixteen patients demonstrated mild allergic symptoms during dialysis treatment. Ten of them had IgE elevation and eosinophilia. Eight of these patients had positive RASTs (ETO: n = 5, ETO-ISO(?)-FA: n = 2, ISO-PHT: n = 1) against dialysis material. All eight had an eosinophilia and seven showed an IgE elevation. An amelioration of symptoms could be obtained in three patients with elevated (greater than 15%) ETO-binding values after switching to ETO-free dialysers; avoiding PHT- and ISO-containing dialysis materials allergic symptoms remained constant. Cuprammonium rayon-induced complement activation had a more rapid onset and was more pronounced in atopic patients. The study confirms the role of ETO, but not of the other dialysis materials in the allergic sensitisation of haemodialysis patients.

Complement Activation

Transmembranous transport and adsorption of beta-2-microglobulin during hemodialysis using polysulfone, polyacrylonitrile, polymethylmethacrylate and cuprammonium rayon membranes.

Beta-2-microglobulin (b2M) was identified as a causative agent of amyloidosis associated with long-term hemodialysis (HD). Therefore, we examined handling of b2M during a 4-hour hemodialysis session. We compared b2M adsoprtion and diffusive/convective elimination between high-flux membranes such as polysulfone (PS; F 60, Fresenius), polyacrylonitrile (AN 69; Filtral, Hospal) and polyacrylonitrile (PAN, PAN 12CX2, Asahi) and less permeable membranes such as cuprammonium rayon (CR; AM 160 H, Asahi) and polymethylmethacrylate (PMMA; BK-1.6 U, Toray). To calculate total elimination, arterio-venous differences of b2M were measured at 0, 5, 20, 60 and 240 minutes; dialysate concentration was analyzed to evaluate diffusive/convective transport. Differences between recovery in dialysate and total removal were regarded as amount removed by adsorption. Total elimination per 4-hour hemodialysis session and per m2 membrane surface was 154.7 +/- 12.3 mg for the PS, 137.8 +/- 28.4 mg for the AN 69, 179.8 +/- 47.5 mg for the PAN, 130.8 +/- 11.8 mg for the PMMA and 14.4 +/- 16.0 mg for the CR membrane. Diffusive/convective transport was 128.0 +/- 18.1 mg for PS, 54.7 +/- 8.1 mg for AN 69 and 106.5 +/- 20.8 mg for PAN and insignificant for PMMA and CR. Adsorption was 26.7 +/- 4.3 mg for PS, 83.1 +/- 29.0 mg for AN 69 and 59.8 +/- 17.2 mg for PAN. Besides transmembranous transport sorption is an important mode of elimination. Weekly endogenous generation rate is about twice as high as b2M elimination.

Acrylic Resins

[Proteinuria].

Explore the source record for details and available documents.

Albuminuria

Dissociation in the excretion of different aldosterone metabolites and unmetabolized ('free') aldosterone in hypertension.

1. The determination of aldosterone-18-glucuronide (pH 1-labile aldosterone) was complemented by concomitant measurements of free urinary aldosterone and tetrahydroaldosterone in 307 patients, most of whom were hypertensive. In 38 cases (12.3%) the normal, aldosterone-18-glucuronide concentration was clinically misleading, but increased free aldosterone and/or tetrahydroaldosterone values suggested the presence of hyperaldosteronism, which in many of these cases was confirmed by elevated excretion of the possible major aldosterone precursor 18-hydroxycorticosterone (18-OH-B). 2. Of 224 patients with essential hypertension and normal or low plasma renin activity 18 had an elevated free aldosterone and/or tetrahydroaldosterone excretion without increased aldosterone-18-glucuronide. These cases may represent early or pre-symptomatic forms of primary hyperaldosteronism. In other cases, particularly when tetrahydroaldosterone was increased alone, abnormalities of aldosterone metabolism were suspected. 3. In two out of 15 patients with primary hyperaldosteronism, aldosterone-18-glucuronide values were frequently found to be normal, although elevations were noted in other variables. However, no relation to the morphological abnormality (adenoma versus hyperplasia) was seen.

18-Hydroxycorticosterone

[Idiopathic edema, capillaropathy, pericardial and pleural effusions with high protein content (author's transl)].

Clinical and electron microscopic studies of two female patients are reported who, in addition to the symptoms and signs of idiopathic edema, had pericardial (and pleural) effusions. In one patient pericardiectomy had to be performed, in the other patient pharmacotherapy with spironolactone was effective. In these patients the protein-concentrations of edema fluid (25 and 12 g/l) and pericardial fluid (55-61 and 48 g/l) were relatively high; the distribution space of labelled protein was increased; blood volumes were low-normal or decreased. Electronmicroscopy of the microvasculature showed identical alterations in both cases. In the cutaneous vessels the endothelium developed numerous abnormal cytoplasmic processes and intercellular "gaps". In the capillaries of skeletal muscle our findings indicate an increase in vesicular transport. We suggest the electron microscopic alterations to be the morphologic correlate for the increased transport and extravascular accumulation of protein. Changes as they are described here in humans with idiopathic edema have been documented before in animals with experimental edema.

Adult

[Edema].

Explore the source record for details and available documents.

Edema