Mean energy, energy-range relationships and depth-scaling factors for clinical electron beams.

Using Monte Carlo simulations we have studied the electron mean energy, Eo, and the most probable energy, Eo,p, at the phantom surface and their relationships with half-value depth, R50, and the practical range, Rp, for a variety of beams from five commercial medical accelerators with an energy range of 5-50 MeV. It is difficult to obtain a relation between R50 and Eo for all electrons at the surface because the number of scattered lower-energy electrons varies with the machine design. However, using only direct electrons to calculate Eo, there is a relationship which is in close agreement with that calculated using monoenergetic beams by Rogers and Bielajew [Med. Phys. 13, 687-694 (1986)]. We show that the empirical formula Eo,p = 0.22 + 1.98Rp + 0.0025R2p describes accurately the relationship between Rp and Eo,p for clinical beams of energies from 5 to 50 MeV with an accuracy of 3%. The electron mean energy, Ed, is calculated as a function of depth in water as well as plastic phantoms and is compared both with the relation, Ed = Eo (1-d/Rp), employed in AAPM protocols and with values in the IAEA Code of Practice. The conventional relations generally overestimate Ed over the entire therapeutic depth, e.g., the AAPM and IAEA overestimate Ed at dmax by up to 20% for an 18 MeV beam from a Clinac 2100C. It is also found that at all depths mean energies are 1%-3% higher near the field edges than at the central axis. We calculated depth-scaling factors for plastic phantoms by scaling the depth in plastics to the water-equivalent depth where the mean energies are equal. The depth-scaling factor is constant with depth in a given beam but there is a small variation ( < 1.5%) depending on the incident beam energies. Depth-scaling factors as a function of R50 in plastic or water are presented for clear polystyrene, white polystyrene and PMMA phantom materials. The calculated depth-scaling factor is found to be equal to R50water/R50plastic. This is just the AAPM definition of effective density but there are up to 2% discrepancies between our calculated values and those recommended by the AAPM and the IAEA protocols. We find that the depth-scaling factors obtained by using the ratio of continuous-slowing-down ranges are inaccurate and overestimate our calculated values by 1%-2% in all cases. We also find that for accurate work, it is incorrect to use a simple 1/r2 correction to convert from parallel beam depth-dose curves to point source depth-dose curves, especially for high-energy beams.

Biophysical Phenomena↗

R50 as a beam quality specifier for selecting stopping-power ratios and reference depths for electron dosimetry.

For electron beam reference dosimetry in radiotherapy, it is shown that by choosing the reference depth as dref = 0.6R(50)-0.1 cm, where R50 is the half-value depth in centimeters, the Spencer-Attix water-to-air stopping-power ratio at dref is given by (Llp)airw = 1.2534 - 0.1487 (R50)0.2144. This is derived from data for (Llp)airw obtained from realistic Monte Carlo simulations for 24 clinical beams. The rms deviation of this expression from the Monte Carlo calculations is 0.16%, with a maximum deviation of 0.26%. This approach fully takes into account the spectral differences between real electron beams of the same R50 and allows an absorbed-dose calibration at a standards laboratory to be easily and accurately transferred to a reference clinical beam. Using a single parameter to specify (Llp)airw, rather than the two parameters (R50 and depth) needed when the reference depth is chosen as the depth of dose maximum, has the potential to greatly simplify electron beam dosimetry protocols and allows the use of a similar formalism for photon and electron beam dosimetry. For use in converting a depth-ionization curve into a depth-dose curve, a somewhat less accurate but general expression for (Llp)w(air) as a function of R50 and depth is presented.

Biophysical Phenomena↗

BEAM: a Monte Carlo code to simulate radiotherapy treatment units.

This paper describes BEAM, a general purpose Monte Carlo code to simulate the radiation beams from radiotherapy units including high-energy electron and photon beams, 60Co beams and orthovoltage units. The code handles a variety of elementary geometric entities which the user puts together as needed (jaws, applicators, stacked cones, mirrors, etc.), thus allowing simulation of a wide variety of accelerators. The code is not restricted to cylindrical symmetry. It incorporates a variety of powerful variance reduction techniques such as range rejection, bremsstrahlung splitting and forcing photon interactions. The code allows direct calculation of charge in the monitor ion chamber. It has the capability of keeping track of each particle's history and using this information to score separate dose components (e.g., to determine the dose from electrons scattering off the applicator). The paper presents a variety of calculated results to demonstrate the code's capabilities. The calculated dose distributions in a water phantom irradiated by electron beams from the NRC 35 MeV research accelerator, a Varian Clinac 2100C, a Philips SL75-20, an AECL Therac 20 and a Scanditronix MM50 are all shown to be in good agreement with measurements at the 2 to 3% level. Eighteen electron spectra from four different commercial accelerators are presented and various aspects of the electron beams from a Clinac 2100C are discussed. Timing requirements and selection of parameters for the Monte Carlo calculations are discussed.

Electrons↗

Calculation of stopping-power ratios using realistic clinical electron beams.

The Spencer-Attix water/air restricted mass collision stopping-power ratio is calculated in realistic electron beams in the energy range from 5-50 MeV for a variety of clinical accelerators including the Varian Clinac 2100C, the Philips SL75-20, the Siemens KD2, the AECL Therac 20, and the Scanditronix Medical Microtron 50. The realistic clinical beams are obtained from full Monte Carlo simulations of the clinical linear accelerators using the code BEAM. The stopping-power ratios calculated using clinical beams are compared with those determined according to the AAPM and the IAEA protocols which were calculated by using monoenergetic parallel beams. Using the energy-range relationship of Rogers and Bielajew [Med. Phys. 13, 687-694 (1986)] leads to the most consistent picture in which the stopping-power ratios at dmax derived from mono-energetic calculations underestimate the stopping-power ratios calculated with the realistic beam by 0.3% at 5 MeV and up to 1.4% at 20 MeV. The stopping-power ratios at dmax determined according to the AAPM TG-21 protocol (1983) are shown to overestimate the realistic stopping-power ratios by up to 0.6% for a 5-MeV beam and underestimate them by up to 1.2% for a 20-MeV beam. Those determined according to the IAEA (1987) protocol overestimate the realistic stopping-power ratios by up to 0.3% for a 5-MeV beam and underestimate them by up to a 1.1% for a 20-MeV beam at reference depth. The causes of the differences in the stopping-power ratios between the realistic clinical mono-energetic beams are analyzed quantitatively. The changes in the stopping-power ratios at dmax are mainly due to the energy spread of the electron beam and the contaminant photons in the clinical beams. The effect of the angular spread of electrons is rather small except at the surface. Data are presented which give the corrected stopping-power ratios at dmax or reference depth starting from those determined according to protocols for any energy of clinical electron beams with scattering foils. For scanned clinical electron beams the correction to stopping-power ratios determined according to protocols is found to be less than 0.5% at dmax or reference depth for all beam energies studied. We quantify the differences in the stopping-power ratios determined using the depth of 50% ionization level and the depth of 50% dose level. The differences are very small except for very-high-energy beams (50 MeV) where they can be up to 0.8%.

Electrons↗

Electron mass scattering powers: Monte Carlo and analytical calculations.

Values of electron mass scattering power, T/p, for various materials have been calculated by using the EGS4 Monte Carlo system and by integration of the Molière multiple-scattering distribution. The energy range covered is 0.5-100 MeV. Monte Carlo calculations test the concept of T/p "experimentally" and assess the contribution to electron mass scattering power from effects such as Moller scatter and energy-loss straggling. The Monte Carlo results agree within 2% with the analytical results calculated from Molière multiple-scattering theory at energies less than 20 MeV for high-Z materials and for energies less than 50 MeV for low-Z materials. At higher energies the Monte Carlo calculations include the effects of bremsstrahlung production which can significantly increase values of T/p. For low-Z materials and electron energies less than 60 MeV, the Monte Carlo calculated T/p values are generally 22% higher than those given by ICRU Report 35, while those for high-Z materials and energies less than 25 MeV are found to be consistent (within 1%) with ICRU Report 35. The effects of Moller scatter, which significantly affect T/p for low-Z materials, as well as bremsstrahlung effects, are included in the present Monte Carlo calculations. If the tabulated T/p data of ICRU Report 35 are modified to include the Moller scatter effect, then for energies less than 60 MeV they are generally 6% less than the present Monte Carlo data for low-Z materials as well as for copper. It is shown that T/p is a well-defined constant over an appropriate range of slab thickness except when bremsstrahlung effects are significant. It is found that T/p is proportional to E-n, where n is in the range of 1.5-2.0 for the energies considered here. The Monte Carlo calculations are shown to agree well with various relevant experimental measurements. Accurate T/p data, which should include the effect of Moller scatter, are necessary in electron-beam treatment planning, especially for a small field size. The choice of the depth step in the implementation of pencil-beam codes should not violate the slab-thickness limits for T/p data.

Electrons↗

Measurements of the electron dose distribution near inhomogeneities using a plastic scintillation detector.

PURPOSE: Accurate measurement of the electron dose distribution near an inhomogeneity is difficult with traditional dosimeters which themselves perturb the electron field. We tested the performance of a new high resolution, water-equivalent plastic scintillation detector which has ideal properties for this application. METHODS AND MATERIALS: A plastic scintillation detector with a 1 mm diameter, 3 mm long cylindrical sensitive volume was used to measure the dose distributions behind standard benchmark inhomogeneities in water phantoms. The plastic scintillator material is more water equivalent than polystyrene in terms of its mass collision stopping power and mass scattering power. Measurements were performed for beams of electrons having initial energies of 6 and 18 MeV at depths from 0.2-4.2 cm behind the inhomogeneities. RESULTS: The detector reveals hot and cold spots behind heterogeneities at resolutions equivalent to typical film digitizer spot sizes. Plots of the dose distributions behind air, aluminum, lead, and formulations for cortical and inner bone-equivalent materials are presented. CONCLUSION: The plastic scintillation detector is suited for measuring the electron dose distribution near an inhomogeneity.

Electrodes↗

The calibration and use of plane-parallel ionization chambers for dosimetry of electron beams: an extension of the 1983 AAPM protocol report of AAPM Radiation Therapy Committee Task Group No. 39.

This report is an extension of the 1983 AAPM protocol, popularly known as the TG-21 Protocol. It deals with the calibration of plane-parallel ionization chambers and their use in calibrating therapy electron beams. A hierarchy of methods is presented. The first is to calibrate the plane-parallel chamber in a high energy electron beam against a cylindrical chamber which has an Ncylgas value that has been obtained from a NIST traceable 60Co beam calibration. The second method, which is recommended for implementation by the ADCLs is an in-air calibration against a NIST-traceable calibrated cylindrical chamber in a Cobalt-60 beam to obtain a plane-parallel-chamber calibration factor in terms of exposure or air kerma. The third method places the two chambers in a phantom in a Cobalt-60 beam, and leads to an Nppgas value for the plane-parallel chamber. This report also gives Nppgas/NxAion)pp and Nppgas/(NkAion)pp values for five commonly used commercially available plane-parallel chambers: the Capintec PS-033, the Exradin P-11, the Holt, the NACP and the PTW-Markus. The calculation of these Ngas ratios introduces a Kcomp factor which is also calculated for the five parallel plate chambers. The use of the plane-parallel chambers follows the 1983 AAPM protocol for absorbed dose calibrations of electrons, except that new energy-dependent Prepl values are given for the Capintec PS-033 and PTW-Markus chambers consistent with the consensus of reports in the literature. For all the chambers, however, Prepl is unity for 20 MeV electrons. This report does not address the issue of the use of plane-parallel chambers in calibrating photon beams.

Cobalt Radioisotopes↗

Reducing electron contamination for photon beam-quality specification.

The percentage depth dose at 10 cm in a 10 x 10-cm2 photon beam at an SSD of 100 cm, %dd(10), is a better beam-quality specifier for radiotherapy beams than the commonly used values of TPR10(20) or nominal accelerating potential. The presence of electron contamination affects the measurement of %dd(10) but can be removed by the use of a 0.1-cm lead filter, which reduces surface dose from contaminant electrons from the accelerator by more than 95% for radiotherapy beams with energies from 60Co to 50 MV. The filter performs best when it is placed immediately below the head. An electron-contamination correction factor is introduced to correct for electron contamination from the filter and air. It converts the %dd(10) which includes the electron contamination with the filter in place [hereafter %dd(10)m], into %dd(10) for just the photons in the filtered beam. The correction factor is a linear function of %dd(10)m for all filtered beams with %dd(10)m > 70%. A small correction for the photon filtering effect converts the pure photon %dd(10) for the filtered beam into that for the unfiltered beam, which can be used to determine stopping-power ratio. Calculations show that the values of water-to-air stopping power ratio in the unfiltered beam are related to the values of %dd(10)m in the filtered beam by a cubic function. The uncertainty of stopping-power ratios in unfiltered beams for the same value of the %dd(10)m is within 0.2% for all beams.

Cobalt Radioisotopes↗

The application of correlated sampling to the computation of electron beam dose distributions in heterogeneous phantoms using the Monte Carlo method.

Although the Monte Carlo method is capable of computing the dose distribution in heterogeneous phantoms directly, there are some advantages to computing a heterogeneity correction factor. If this approach is adopted there are savings in time using correlated sampling. This technique forces histories to have the same energy, position, direction and random number seed as incident on both the heterogeneous and homogeneous water phantom. This ensures that a history that has, by chance, travelled through only water in the heterogeneous phantom will have the same path as it would have through the homogeneous phantom, resulting in a reduced variance when a ratio of heterogeneous dose to homogeneous dose is formed. Metrics to describe the distributions of uncertainty, efficiency, and degree of correlation are defined. EGS4 Monte Carlo calculation of the dose distribution from a 20 MeV electron beam on water phantoms containing aluminum or air slab heterogeneities illustrate that this technique is the most efficient when the heterogeneity is deep within the phantom, but that improved efficiency can be realized even when the heterogeneity is at or near the surface. This is because some correlation between the two histories is retained despite passage through the heterogeneity.

Electrons↗

Augmentation of the systemic host anti-tumor response through laser excision.

This study examines whether primary laser excision results in augmentation of the systemic host anti-tumor response to tumor rechallenge. Single R3230AC mammary tumor implants, (0.5 x 0.5 x 1.0 mm), were grown in 112 female Fisher 344 rats. The animals were randomized. Group S tumors were excised by scalpel. Group E was excised with a Surgistat electrocautery (Valley Labs, Boulder, CO). Group CS was excised with a Sharplan 1100 CO2 laser (Sharplan, Allendale, NJ) at 25 watts (W) continuous wave (CW) (0.2 mm spot size) and the wound was "sterilized" with a 5-mm spot size by gently heating the tissue without blanching. Group K was excised with a KTP/532 laser (Laserscope, San Jose, CA) at 17 W CW using a 400 microns fiber. Group Y was excised with a Sharplan 2100 Nd:YAG laser set at 15W CW using a 0.2 mm clear sapphire tip. A second tumor implant, (0.5 x 0.5 x 1.0 mm), was placed at a remote site 14 days postoperatively. An unoperated control group was implanted. Secondary tumor volumes were measured for 36 days and the mean tumor volumes (MTV) were statistically compared. The MTV in groups CS, K, Y, and E was less than control (P less than 0.01). The MTV in groups CS, K, Y, and E was less than group S, although this was not statistically different. Lasers and cautery appear to increase the host response against subsequent tumor challenge. This study corroborates earlier studies of other modalities. Further studies to determine whether this host sensitization is an immune response and to elucidate the mechanisms of this effect are warranted.

Animals↗

Hepatitis C virus does not cause nonalcoholic steatohepatitis.

The pathogenesis of nonalcoholic steatohepatitis (NASH) remains poorly understood. Since inflammation and fatty changes are associated with hepatitis C (HCV) infection, we have tested the role of HCV in the genesis of NASH. Five consecutive cases of classic NASH were tested by Abbott anti-c100-3 EIA and polymerase chain reaction (PCR) to detect HCV-RNA. All serum specimens were negative for anti-c100-3 (or anti-HCV EIA) and HCV PCR. Based on this study, we conclude that HCV does not play a causative or contributing role in the pathogenesis of NASH.

Adult↗

Ergonomics of medical lasers: operator's viewpoint.

Lasers are instruments that may enhance the surgeon's ability to perform surgery. Many medical lasers sit unused. Lack of use is associated with "user unfriendliness." Nurses and surgeons often cite factors such as complexity, location, and types of controls, and content of displays. Other factors such as culture-ethnology and its relationship to command words and symbols, affect understandability of controls, displays, and user friendliness. Laser designers and engineers must analyze the interaction between laser users and products. Laser design and operation must coincide with specific needs and expectations of the nurses and physicians. Poor design and engineering compromises result in nonuse of expensive instrumentation, products which are ineffective for clinical use, and could potentially increase the risk of possible injury to patients and staff. This discussion of the design and operation of medical laser systems, presents the advantages and disadvantages of several laser systems. User interfaces for controls: color, function, touch activation, labels and size, sound cues, laser activation, type and amount of feedback information during operation; design of storage for accessories, and need for features such as pulsing, and milliwatts will be discussed. We will present what we consider to be an ideal laser system.

Equipment Design↗

The effect of Nd:YAG laser-induced hyperthermia on local tumor recurrence in experimental rat mammary tumors.

The influence of Nd:YAG laser hyperthermia (45 degrees C for 20 min) on local tumor recurrence followed by CO 2 laser or scalpel excision was studied on 150 F344 female rats that were implanted with R3230AC mammary tumor in the mammary ridge. The development of local tumor recurrence was observed for 39 days postoperatively. All groups undergoing CO 2 laser excision showed a significant reduction in local tumor recurrence (p less than 0.05) compared with the scalpel technique. Animals that underwent CO 2 laser excision and wound sterilization 48 h following laser hyperthermia demonstrated the lowest recurrence when compared with scalpel excision (p less than 0.01). These results indicate that the local thermal effect achieved by laser hyperthermia or laser sterilization plays an important role in the reduction of local tumor recurrence and augments complete local tumor resection.

Aluminum↗

Post-cardiac surgery tamponade mimicking acute hepatitis. Report of two cases.

Two patients developed cardiac tamponade from delayed hemorrhage into the pericardial sac following open heart surgery. The initial clinical manifestations of tamponade included nausea and dramatic elevations of serum aminotransferases, simulating acute hepatitis. To our knowledge, this presentation of cardiac tamponade has not been previously reported.

Acute Disease↗

Effect of argon laser and Photofrin II on murine neuroblastoma cells.

Laser-induced fluorescence (LIF) of photosensitizers is used to detect cancer. The effect of argon laser light with an average irradiance of 31 mW cm-2 and Photofrin II (Dihematoporphyrin ether, DHE) at concentrations of 1.0 and 5.0 micrograms ml-1 on C1300 murine neuroblastoma cells (MNB, NB41A3) in vitro was investigated. Growth curves and cell viability (trypan blue dye exclusion) were determined at 1, 24, 96, and 144 hr post-irradiation. Light doses of 1.8 and 9.0 J cm-2 combined with 5.0 micrograms DHE ml-1 decreased both cell numbers and viability, immediately and up to 144 hr postirradiation. Argon laser light alone at a fluence of 9.0 J cm-2 caused reversible injury to the cells. This in vitro study shows that both low energy argon laser light and low dose DHE are cytocidal to C1300 MNB cells. LIF promises to aid in the detection and destruction of neuroblastoma. Surgeons should be aware that tissue irreversible damage is likely to occur when performing LIF detection of neuroblastoma. The doses of laser light and of Photofrin II found to be toxic to neuroblastoma cells in culture may provide guidelines for photodynamic therapy ablation of neuroblastoma clinically.

Animals↗

The role of Monte Carlo simulation of electron transport in radiation dosimetry.

A brief overview is given of the role in radiation dosimetry of electron transport simulations using the Monte Carlo technique. Two areas are discussed in some detail. The first is the calculation of stopping-power ratios for use in ion chamber dosimetry. The uncertainty in stopping-power ratios is discussed with attention being drawn to the fact that the relative uncertainty in restricted collision stopping powers is greater than that in unrestricted stopping powers if the major source of uncertainty is the density effect correction. Using ICRU Report 37 stopping powers and electron spectra calculated in a small cylinder of graphite, the value of the Spencer-Attix graphite to air stopping-power ratio in a 60Co beam is found to be 1.0021 for an assumed graphite density of 1.70 g/cm(3) and 0.23% less for an assumed density of 2.26 g/cm(3). The second area discussed is the feasibility of using Monte Carlo techniques to calculate dose patterns in a patient undergoing electron beam radiotherapy.

Electrons↗

Methods for the endoscopic photographic and visual detection of helium cadmium laser-induced fluorescence of Photofrin II.

Endoscopic detection of small tumors is key to the early diagnosis and treatment of malignancy. This paper describes a simple, endoscopic detection system which enables tumor localization and a permanent record based on the laser-induced fluorescence of dihematoporphyrin ether (LIFD). Spectral analysis of dihematoporphyrin ether (DHE, Photofrin II) was performed with a Perkin Elmer LS-5 scanning fluorimeter. DHE at concentrations of 50 micrograms/ml and 5 micrograms/ml in 95% ethanol were tested, demonstrating fluorescence quenching at 50 micrograms/ml DHE at 406 nm excitation. This phenomenon was not observed at 442 nm excitation. Based on this data and the availability of the helium cadmium laser, a series of endoscopic detection systems was developed and tested utilizing a LiConix 4240NB helium cadmium laser (TEMoo, 442 nm, 40 mW). A fiber with a microdiverging (MDL) lens was used. Irradiance achieved at the tip of the fiber was 31.58 mW/cm2 for MDL. A Corning 34832 (550 nm) sharp cutoff barrier filter was coupled to an Olympus OES BF2T10 bronchoscope. Successful detection of LIFD was obtained. Direct observation of LIFD is possible when wearing Laserguard argon safety goggles (OD 15 at 488 nm, OD 11 at 514 nm). Photographic recording of LIFD was performed with the following cameras and parameters: Olympus OM-2S camera (OM2) with EES135 film (ISO 1600) with a 4-second exposure (method 1) and the Olympus OES SCP-10 instant camera with Polaroid 779 (ISO 640) film and a 120-second exposure (method 2). The photographic methods demonstrate the red fluorescence of DHE on filter paper disks at concentrations of 0.5 micrograms/ml (500 ng/ml). (ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗

Ruptured mycotic pseudoaneurysm of the gastroduodenal artery presenting with hemoperitoneum and subcapsular liver hematoma.

We report a case of a patient with mycotic pseudoaneurysm of the gastroduodenal artery who presented with hemoperitoneum and subcapsular hematoma of the liver. The diagnosis was established with contrasted abdominal CT scanning. Visceral angiography was not needed. Prompt recognition and surgical intervention led to a favorable outcome. Pseudoaneurysm of visceral vessels is an uncommon disease process, and to our knowledge, this is the first reported case that has presented with free blood in the peritoneal cavity and beneath the liver capsule. This case may also represent a rare complication of therapeutic ERCP procedures. Mycotic aneurysm or pseudoaneurysm of visceral vessels may develop from bacteremia and its dissection or rupture should be suspected in patients presenting with sepsis and abdominal pain.

Aged↗