Search PubMed⌕ Search

Biomedical subjects

D W Murray

Publications and source records attributed to D W Murray.

At least 73 records · Page 4Linked to original sources

Macrophage colony-stimulating factor and interleukin-6 release by periprosthetic cells stimulates osteoclast formation and bone resorption.

Periprosthetic bone loss is an important contributory factor for aseptic loosening of total joint replacements. It has recently been shown that osteoclast precursor cells are present in the wear particle-associated macrophage infiltrate found in the membrane surrounding loose implants and that these cells are capable of differentiating into osteoclastic bone-resorbing cells. Long-term co-culture of arthroplasty-derived macrophages and the rat osteoblast-like cell line, UMR-106, in the presence of 1,25(OH)2D3 results in the formation of numerous multinucleated cells that are positive for tartrate-resistant acid phosphatase and vitronectin receptor and capable of extensive lacunar bone resorption. The aim of this study was to determine the effect of cytokines/growth factors, known to be present in the arthroplasty membrane, on this process of osteoclast differentiation. During osteoclast formation, increased levels of macrophage colony-stimulating factor, interleukin-6, and to a lesser extent, interleukin-1beta, but not tumour necrosis factor alpha, were detected in the co-culture supernatants. Addition of neutralising antibodies to human interleukin-1beta or tumour necrosis factor alpha to the co-culture system did not inhibit osteoclast formation. In contrast, co-cultures to which neutralising antibodies to human macrophage colony-stimulating factor or interleukin-6 were added contained fewer cells positive for tartrate-resistant acid phosphatase and vitronectin receptor and formed significantly fewer resorption pits. Time-course studies showed that macrophage colony-stimulating factor and interleukin-6 increase osteoclast formation mainly in the early stages of osteoclast differentiation. These results indicate that the release of macrophage colony-stimulating factor and interleukin-6 by activated cells in the arthroplasty membrane is likely to contribute to pathological bone resorption associated with aseptic loosening by stimulating differentiation of mononuclear phagocyte osteoclast precursors into mature bone-resorbing cells.

Acetabulum↗

Mid-term migration of a cemented total hip replacement assessed by radiostereometric analysis.

We have previously reported the short-term migration of cemented Hinek femoral components using radiostereometric analysis (RSA). We now report the mid-term migration. During the first 2 years after implantation the prosthesis subsided into varus and rotated internally. Between years 3 and 8 the prosthesis continued to rotate internally with the head moving posteriorly (0.07 mm/year, P=0.004). It also continued to fall into varus with the tip moving laterally (0.07 mm/year, P=0.04). The head (0.06 mm/year, P<0.0001), shoulder (0.04 mm/year, P=0.0001) and tip (0.04 mm/year, P=0.001) continued to migrate distally. There were two cases of failure due to aseptic loosening during the follow-up period. During the second year both of these had posterior head migration, which was abnormally rapid (>2 SD from the mean). We have demonstrated that a cemented implant has slow but significant levels of migration and rotation for at least 8 years after implantation. Our study confirms that implants with abnormally rapid posterior head migration during the second year are likely to fail.

Bone Cements↗

One- or two-stage bilateral total hip replacement.

It is not clear whether bilateral hip replacement should be done in 1 or 2 stages. The total number of total hip replacements (THRs) done in our center between 1989 and 1995 was approximately 4,000. The number of hips that were bilateral was 404, or 9% of the total number of THRs performed during this time period. Of these bilateral hip replacements, 190 (95 patients) were done as a 1-stage procedure, whereas 214 (107 patients) were done in 2 stages with 2 to 24 months in between the operations. In contrast to previous studies, there were no significant preoperative differences between the 2 groups of patients having 1-stage or 2-stage THRs, and, in particular, the comorbidity assessed by the American Society of Anesthesiologists (ASA) grade was not significantly different. Our results demonstrate that, in our patient population, bilateral THR was equally safe whether performed as a 1-stage or 2-stage procedure. This was the case in the low-risk (ASA 1 and 2) and high-risk (ASA 3 and 4) patient subgroups. One-stage bilateral THR is cheaper and involves less time in the hospital.

Aged↗

Cement migration after THR. A comparison of charnley elite and exeter femoral stems using RSA.

Studies using roentgen stereophotogrammetric analysis (RSA) have shown that the femoral components of cemented total hip replacements (THR) migrate distally relative to the bone, but it is not clear whether this occurs at the cement-implant or the cement-bone interface or within the cement mantle. Our aim was to determine where this migration occurred, since this has important implications for the way in which implants function and fail. Using RSA we compared for two years the migration of the tip of the stem with that of the cement restrictor for two different designs of THR, the Exeter and Charnley Elite. We have assumed that if the cement restrictor migrates, then at least part of the cement mantle also migrates. Our results have shown that the Exeter migrates distally three times faster than the Charnley Elite and at different interfaces. With the Exeter migration was at the cement-implant interface whereas with the Charnley Elite there was migration at both the cement-bone and the cement-implant interfaces.

Aged↗

Does arthritis progress in the retained compartments after 'Oxford' medial unicompartmental arthroplasty? A clinical and radiological study with a minimum ten-year follow-up.

We determined the outcome of 56 'Oxford' unicompartmental replacements performed for anteromedial osteoarthritis of the knee between 1982 and 1987. Of these, 24 were in patients who had died without revision, one was lost to follow-up and two had been revised. Of the remaining 29 knees, 26 were examined clinically and radiologically, two were only examined clinically and one patient was contacted by telephone. The mean age of the patients was 80.3 years. At a mean follow-up of 11.4 years (10 to 14) the measurements of the knee score, range of movement and degree of deformity were not significantly different from those made one to two years after operation, except that the range of flexion had improved. Comparison of fluoroscopically-controlled radiographs at a similar interval of time showed no change in the appearance of the lateral compartments. The retained articular cartilage continued to function for ten or more years which suggests that anteromedial osteoarthritis may be considered as a focal disorder of the knee. This justifies continued efforts to develop methods of treatment which preserve intact joint structures.

Aged↗

The length of the patellar tendon after unicompartmental and total knee replacement.

Patella infera may occur after reconstruction of the anterior cruciate ligament (ACL), high tibial osteotomy and total knee replacement (TKR). Restriction of movement of the knee and pain may result. Our aim was to compare the incidence and to assess the effects of patella infera after TKR and unicompartmental knee replacement (UKR). We reviewed radiographs of the knees of 84 patients who had had either TKR or UKR as part of a randomised, controlled trial The length of the patellar tendon was measured on serial radiographs taken before, at eight months and at five years after operation. There was no significant change in the length of the patellar tendon after UKR, but a significant reduction was observed after TKR. Five years after the operation, the shortening of the tendon had increased to a mean of 3.5 mm. Of the knees with TKR reviewed at five years, 34% developed patella infera, defined as 10% or more of shortening, compared with 5% of those with UKR. Shortening was greatest in those knees which had required a lateral release; in this subgroup the mean shortening was 7.2 mm. Shortening correlated with restriction of movement and pain in the knee. Our study has shown that patella infera develops in most patients after TKR with lateral release, and in approximately 25% of patients after TKR without this additional procedure. Patella infera rarely occurs after UKR. It is associated with restriction of movement and pain in the knee. It may be an effect of the more extensive exposure required to perform TKR and may, in part, explain the better clinical results of UKR.

Aged↗

Fluid flow around model femoral components of differing surface finishes: in vitro investigations.

We studied fluid flow at the stem-cement interface of bonded and debonded, polished and rough model femoral components. In a first series of experiments, fluid flow along the interface between bone cement and well-fixed model femoral components, differing in surface finish, and in shape, was measured. Fluid migration along the bone-cement interface of rough stems (Ra 3 microm) was greater than that on polished stems (p < 0.001). This was true of cylindrical and conical tapered stems. On stems with the same surface finish, shape did not influence fluid migration. In a second series of experiments, fluid flow along the stem-cement interface of 5 highly polished and 10 rough-finished (5 of Ra approximately 1.5 microm and 5 of Ra approximately 3 microm), debonded, tapered circular stems was measured. None of the rough stems could prevent fluid flow along the stem-cement interface. Polished tapered stems sealed the interface and, after 48 hrs of continuous pressure, no fluid flow was observed. This difference in the ability to seal the stem-cement interface between rough and polished stems was significant (p < 0.001). The difference in fluid migration along the stem-cement interface of rough and polished stems which we observed offers a plausible explanation of the occurrence of osteolysis distal to the articulation of cemented THR in the presence of cement mantle defects. It may also explain why osteolysis is uncommon with polished double-tapered stems.

Cementation↗

Bisphosphonates in bone cement inhibit PMMA particle induced bone resorption.

OBJECTIVE: Wear particle induced bone resorption is thought to be one of the mechanisms that contribute to implant loosening. It has previously been shown that macrophages, in response to polymethylmethacrylate (PMMA) particles, differentiate into bone resorbing osteoclasts, and that this process is inhibited by a bisphosphonate, etidronate (EHDP). The aim of this study was to determine whether incorporating EHDP in bone cement could reduce PMMA associated bone resorption. METHODS: Two concentrations of EHDP were mixed with PMMA monomer before polymerisation. Particles of PMMA (1-10 microns) were generated then added to mouse monocytes cocultured with UMR106 rat osteoblast-like cells and the extent of osteoclast differentiation was determined by assessing the extent of tartrate resistant acid phosphatase (TRAP) staining and measuring the amount of lacunar bone resorption. RESULTS: The addition of PMMA to monocyte-UMR106 cocultures resulted in a marked increase in the number of TRAP positive osteoclast-like cells and a significant increase in the number of lacunar resorption pits compared with control cultures to which no particles had been added. After the addition of particles of PMMA + 20 mg EHDP, significantly fewer lacunar pits (p = 0.00006) and fewer TRAP positive cells were noted compared with cocultures containing PMMA particles alone. CONCLUSIONS: These results indicate that by mixing a bisphosphonate with bone cement, it is possible to inhibit PMMA particle induced bone resorption. This bisphosphonate inhibition of PMMA biomaterial wear particle containing macrophage-osteoclast differentiation and bone resorption may provide a possible therapeutic strategy to prevent or to control the osteolysis of aseptic loosening.

Animals↗

Diagnostic value of intra-articular anaesthetic in primary osteoarthritis of the hip.

We investigated 42 patients who were being considered for primary total hip arthroplasty (THA), but in whom it was uncertain whether the hip was the source of their pain. They were given an injection of local anaesthetic into the joint space. Of 33 patients who gained pain relief from their injection, 32 subsequently had successful THA. The remaining patient has not had surgery. The intra-articular injection of local anaesthetic is thus at least 96% sensitive. Of the nine patients who had no or only minimal pain relief from injection, one has had an unsuccessful THA, three have been successfully treated for other conditions and five have unresolved pain for which no organic basis has been established. We believe that the injection of local anaesthetic into the hip is a reliable test, with low morbidity. In difficult cases it will aid in the clarification of the cause of pain which possibly arises from the hip.

Anesthetics, Local↗

Pain in the assessment of total knee replacement.

The results of total knee replacement (TKR) are commonly assessed by survival analysis using revision as the endpoint. We have used the assessment of pain by a patient-based questionnaire as an alternative. In one hospital, 1429 TKRs were inserted by 66 surgeons between 1987 and 1993. The survival at seven years, with revision as the endpoint, was 97.5% (CI 94 to 100). There were no significant differences between the three different types of implant used, the AGC, the IB2 and the Nuffield Knee. When the endpoint was the development of moderate pain, the survival at seven years for the AGC knee was 72% and that for the IB2 was similar. Significantly more patients (p = 0.007) with the Nuffield Knee, however, had developed moderate pain. Using revision as the endpoint, it is difficult to discriminate between the various types of TKR, but this can be achieved using pain. In this investigation 30% of the patients reported moderate pain at some stage by seven years from operation.

Age Factors↗

In vitro measurement of patellofemoral force after three types of knee replacement.

Using a new, non-invasive method, we measured the patellofemoral force (PFF) in cadaver knees mounted in a rig to simulate weight-bearing. The PFF was measured from 20 degrees to 120 degrees of flexion before and after implanting three designs of knee prosthesis. Medial unicompartmental arthroplasty with a meniscal-bearing prosthesis and with retention of both cruciate ligaments caused no significant change in the PFF. After arthroplasty with a posterior-cruciate-retaining prosthesis and division of the anterior cruciate ligament, the PFF decreased in extension and increased by 20% in flexion. Implantation of a posterior stabilised prosthesis and division of both cruciate ligaments produced a decrease in the PFF in extension but maintained normal load in flexion. There was a direct relationship between the PFF and the angle made with the patellar tendon and the long axis of the tibia. The abnormalities of the patellar tendon angle which resulted from implantation of the two total prostheses explain the observed changes in the PFF and show how the mechanics of the patellofemoral joint depend upon the kinematics of the tibiofemoral articulation.

Arthroplasty, Replacement, Knee↗

Wear of congruent meniscal bearings in unicompartmental knee arthroplasty: a retrieval study of 16 specimens.

Many designs of unicompartmental knee replacement show early and mid-term failure due to polyethylene wear. We studied the wear rate of congruent polyethylene meniscal bearings retrieved from failed Oxford unicompartmental knee replacements. We examined 16 bearings, 0.8 to 12.8 years after implantation, measuring their thickness and comparing it with that of 14 unused bearings. The mean rate of penetration, which included the effects of wear at both upper and lower surfaces, was 0.036 mm per year (maximum 0.08). Bearings as thin as 3.5 mm wore no faster than thicker models, but ten with evidence of impingement had greater wear. The six bearings with no impingement showed a mean rate of penetration of 0.01 mm per year. In unicompartmental knee replacement, careful implantation of fully congruous meniscal bearings can avoid failure due to polyethylene wear.

Aged↗

The Oxford medial unicompartmental arthroplasty: a ten-year survival study.

Retrieval studies have shown that the use of fully congruent meniscal bearings reduces wear in knee replacements. We report the outcome of 143 knees with anteromedial osteoarthritis and normal anterior cruciate ligaments treated by unicompartmental arthroplasty using fully congruous mobile polyethylene bearings. At review, 34 knees were in patients who had died and 109 were in those who were still living. The mean elapsed time since operation was 7.6 years (maximum 13.8). We established the status of all but one knee. There had been five revision operations giving a cumulative prosthetic survival rate at ten years (33 knees at risk) of 98% (95% CI 93% to 100%). Considering the knee lost to follow-up as a failure, the 'worst-case' survival rate was 97%. No failures were due to polyethylene wear or aseptic loosening of the tibial component. One bearing which dislocated at four years was reduced by closed manipulation. The ten-year survival rate is the best of those reported for unicompartmental arthroplasty and not significantly different from the best rates for total knee replacement.

Adult↗

Expansion of an osteoarthritic cyst associated with wear debris: a case report.

We present a case in which the growth of an intraosseous cyst arising from the proximal tibiofibular joint appeared to have been increased by polyethylene wear particles from a medial unicompartmental knee replacement. Histological examination of the cyst wall showed a histiocytic response associated with numerous polyethylene wear particles. This case demonstrates that there is a direct communication between the joint cavity and the cyst. Such communication is probably through openings in the articular cartilage large enough to allow the passage of these particles.

Aged↗

In vitro patellofemoral joint force determined by a non-invasive technique.

OBJECTIVE: To develop a method of measuring the magnitude, direction and point of application of the patellofemoral force (PFF), directly and non-invasively in three dimensions. DESIGN AND METHODS: The compressive PFF is replaced exactly with a tensile force applied to the front of the patella. The magnitude, direction and point of application of the tensile force are then measured. The technique was applied to six normal knees mounted in a 6 degree of freedom rig with quadriceps tendon tension force (QTF) applied to balance a flexing load and to simulate weight bearing. RESULTS: The PFF was greater than in previous more invasive in vitro studies but the results correlated well with recent theoretical analyses. At 20 degrees knee flexion the force was 75% of QTF. It increased to 100% of QTF at 60 degrees knee flexion and remained at this level at higher angles of flexion. The lateral vector of the PFF was small compared to the sagittal plane vector and became negligible beyond 60 degrees of knee flexion. The point of application of the PFF to the patella moved proximally and medially with knee flexion. CONCLUSIONS: A new and reliable method of measuring PFF non-invasively and in three dimensions has been developed. RELEVANCE: A new technique is described for measuring the PFF in vitro. The non-invasive nature of the technique makes it useful for studying the effect on the PFF of simulated pathological conditions, surgical procedures and different types of knee replacement.

Journal Article↗

Steering without representation with the use of active fixation.

This paper demonstrates the use of active fixation on both fixed and moving fixation points to guide a robot vehicle by means of a steering rule which, at large distances, sets the steering angle directly proportional to the deviation of gaze direction from translation direction. Steering a motor vehicle around a winding but otherwise uncluttered road has been observed by Land and Lee to involve repeated periods of visual fixation upon the tangent point of the inside of each bend. We suggest that proportional rule devised for steering in the robotic example appears applicable to the observed human performance data, providing an alternative explanation to the quadratic rule proposed by Land and Lee.

Humans↗