Search PubMed⌕ Search

Biomedical subjects

D W Davies

Publications and source records attributed to D W Davies.

At least 19 recordsLinked to original sources

Role of electrophysiological study and ablation in the management of recurrent atrial flutter associated with haemodynamic compromise in a critically ill patient.

Atrial flutter is a common arrhythmia. In the critical care setting, the arrhythmia may present in any patient, but it is most commonly seen in patients with impaired ventricular function, valvular disease, atrial dilatation or after cardiac surgery. We present a 68-year-old lady with recurrent poorly tolerated atrial flutter that was resistant to multiple pharmacological interventions and complicated by cardiogenic shock following direct current cardioversion. The flutter was successfully cured with radiofrequency ablation and was followed by an immediate improvement in her haemodynamic status. We review the management of acute atrial flutter and discuss the role of electrophysiologically guided ablation.

Aged↗

Characterization of the anatomy and conduction velocities of the human right atrial flutter circuit determined by noncontact mapping.

OBJECTIVES: This study was done to characterize human right atrial (RA) flutter (AFL) using noncontact mapping. BACKGROUND: Atrial flutter has been mapped using sequential techniques, but complex anatomy makes simultaneous global RA mapping difficult. METHODS: Noncontact mapping was used to map the RA of 13 patients with AFL (5 with previous attempts), 11 with counterclockwise and 2 with clockwise AFL. "Reconstructed" electrograms were validated against contact electrograms using cross-correlation. The Cartesian coordinates of points on a virtual endocardium were used to calculate the length and thus the conduction velocity (CV) of the AFL wave front within the tricuspid annulus-inferior vena cave isthmus (IS) and either side of the crista terminalis (CT). RESULTS: When clearly seen, the AFL wave front split (n = 3) or turned in the region of the coronary sinus os (n = 6). Activation progressed toward the tricuspid annulus (TA) from the surrounding RA in 10 patients, suggesting that the leading edge of the reentry wave front is not always at the TA. The IS length and CV was 47.73 +/- 24.40 mm (mean +/- SD) and 0.74 +/- 0.36 m/s. The CV was similar for the smooth and trabeculated RA (1.16 +/- 0.48 m/s and 1.22 +/- 0.65 m/s, respectively [p = 0.67]) and faster than the IS (p = 0.03 and p = 0.05 for smooth and trabeculated, respectively). CONCLUSIONS: Noncontact mapping of AFL has been validated and has demonstrated that IS CV is significantly slower than either side of the CT.

Adult↗

Two episodes of life-threatening anaphylaxis in the same patient to a chlorhexidine-sulphadiazine-coated central venous catheter.

Chlorhexidine allergy has been described in the literature, mainly in Japanese individuals. Most reactions have been limited to the skin, mild in severity and a result of chlorhexidine containing solutions such as 'Savlon' (Novartis Consumer Health, Horesham, UK). We describe what we believe is the first reported case of anaphylaxis in a European patient to a chlorhexidine- sulphadiazine-coated central venous catheter.

Anaphylaxis↗

Catheter ablation of ventricular tachycardia related to coronary artery disease: the role of noncontact mapping.

There are a number of limitations associated with conventional mapping for ablation of ventricular tachycardia (VT) in ischemic heart disease, such as the high recurrence rates after initially successful ablation. The development of a noncontact mapping system capable of producing high-resolution isopotential maps of the entire left ventricle has enabled rapid identification of diastolic activity that maintains VT for ablation. With this system it is possible to map nonsustained and fast unstable as well as stable VTs. In this article we review the historic background and concepts of noncontact mapping, its clinical application, and the results of ablations for human VT guided by this mapping system.

Body Surface Potential Mapping↗

Endocardial mapping of atrial fibrillation in the human right atrium using a non-contact catheter.

BACKGROUND: Endocardial mapping of atrial fibrillation in humans is limited by its low resolution and by complexities in the arrhythmia and atrial anatomy. METHODS AND RESULTS: A catheter mounted non-contact multielectrode was deployed in the right atrium of 11 patients with atrial fibrillation and used to reconstruct 3360 electrograms, superimposed onto a computer-simulated model of the endocardium, using inverse solution mathematics. This allows construction of isopotential maps of the right atrium. Patients had either sustained atrial fibrillation (n=3) for >6 months or developed atrial fibrillation during the study (n=8). Spontaneous initiation of atrial fibrillation was recorded in one patient and was demonstrated by the non-contact system to arise from two successive atrial ectopic beats from the site of a roving contact catheter. Reconstruction of electrograms recorded during atrial fibrillation was validated by comparison with contact electrograms with cross-correlation. During established atrial fibrillation, four patients predominantly had a single right atrial wave front, two had two wave fronts and five patients had three to five wave fronts for most of the time. Periods of electrical silence were seen in the right atrium in eight patients, after which, activity emerged from consistent septal sites alone, suggesting a left atrial origin. During intravenous administration of flecainide, atrial fibrillation in two patients terminated spontaneously or following pacing manoeuvres, while in the remaining patient sinus rhythm was restored via atrial tachycardia. CONCLUSION: Non-contact mapping of the right atrium has demonstrated modes of initiation and termination of atrial fibrillation, characterized different patterns of right atrial activation in atrial fibrillation and suggests that the left atrium may sustain atrial fibrillation in some patients. Simultaneous mapping of the right and left atrium is required to further elucidate the mechanisms of human atrial fibrillation.

Adult↗

Persistent but reversible coronary microvascular dysfunction after bypass grafting.

The effect of coronary artery bypass grafting (CABG) on absolute myocardial blood flow (MBF) has not been investigated previously. MBF (ml. min(-1). g(-1)) was measured at rest and during hyperemia (0.56 mg/kg iv dipyridamole) using H(2)(15)O and positron emission tomography in eight patients with three-vessel disease before surgery and 1 and 6 mo after full revascularization. Baseline MBF was 0.87 +/- 0.12 preoperatively and 1.04 +/- 0.14 and 0.95 +/- 0.13 at 1 and 6 mo after CABG, respectively (P < 0.05, 6 mo vs. preoperatively). Hyperemic MBF was 1.36 +/- 0.28 preoperatively and increased to 1.98 +/- 0.50 and 2.45 +/- 0.64 at 1 and 6 mo after CABG, respectively (P < 0.01, 6 mo vs. preoperatively). Coronary vasodilator reserve (hyperemic/baseline MBF) increased from 1.59 +/- 0.40 preoperatively to 1.93 +/- 0.13 and 2.57 +/- 0.49 at 1 and 6 mo, respectively (P < 0.05, 6 mo vs. preoperatively). Minimal (dipyridamole) coronary resistance (mmHg. min. g(-1). ml(-1)) fell progressively from 59.37 +/- 14.56 before surgery to a nadir of 35. 76 +/- 10.12 at 6 mo after CABG (P < 0.01 vs. preoperatively). The results of the present study confirm that CABG improves coronary vasodilator reserve progressively as a result of reduction in minimal coronary resistance. These data suggest persistent microvascular dysfunction that recovers slowly after surgery.

Adult↗

Feasibility of a noncontact catheter for endocardial mapping of human ventricular tachycardia.

BACKGROUND: Catheter ablation of ventricular tachycardia (VT) is limited by difficulty in identifying suitable sites for ablation. This study assesses use of a system capable of simultaneous endocardial mapping of the human left ventricle to map and guide radiofrequency (RF) catheter ablation of VT. METHODS AND RESULTS: A catheter-mounted noncontact multielectrode array was used to reconstruct 3360 electrograms, superimposed onto a computer-simulated endocardial model. Of 24 patients studied, 20 had ischemic heart disease. Exit sites were demonstrated by the noncontact system in 80 (99%) of 81 VTs, with complete VT circuits traced in 17 (21%). In another 37 VTs, 36+/-30% (mean+/-SD) of the diastolic interval was identified. Thirty-eight VT morphologies were ablated with 154 RF energy applications. Successful ablation was achieved by 77% of RF applications to relevant diastolic activity identified by the system and was significantly more likely (P<0.0001) than by RF at the VT exit or remote from diastolic activation. Over a mean follow-up of 1.5 years, 14 patients (64%) have had no recurrence of VT, and only 2 target VTs (5.3%) have recurred. Five patients have had recurrence of other VTs. CONCLUSIONS: This noncontact mapping system identified diastolic portions of the circuit in most VTs studied and can safely map and guide ablation of human VT.

Adult↗

Noncontact mapping of cardiac arrhythmias.

The development of new mapping systems is beginning to overcome some of the limitations of conventional techniques by offering percutaneous deployment, simultaneous acquisitions of data, high-resolution maps, and correlation of anatomy and electrophysiology, in addition to a catheter location system. The noncontact mapping system continues to undergo development and does not completely address all requirements for an ideal mapping system. The limitations of the system include deterioration in the quality of electrogram reconstruction with increasing distance between the MEA and the endocardium, the inability of the noncontact system to identify subendocardial activation, and problems with distinguishing noise from low-amplitude diastolic electrograms.

Arrhythmias, Cardiac↗

Mapping and ablation of ventricular tachycardia with the aid of a non-contact mapping system.

OBJECTIVE: Treatment of ventricular tachycardia (VT) in coronary heart disease has to date been limited to palliative treatment with drugs or implantable defibrillators. The results of curative treatment with catheter ablation have proved disappointing because the complexity of the VT mechanism makes identification of the substrate using conventional mapping techniques difficult. The use of a mapping technology that may address some of these issues, and thus make possible a cure for VT with catheter ablation, is reported. PATIENTS AND INTERVENTION: The non-contact system, consisting of a multielectrode array catheter (MEA) and a computer mapping system, was used to map VT in 24 patients. Twenty two patients had structural heart disease, the remainder having "normal" left ventricles with either fasicular tachycardia or left ventricular ectopic tachycardia. RESULTS: Exit sites were demonstrated in 80 of 81 VT morphologies by the non-contact system, and complete VT circuits were traced in 17. In another 37 morphologies of VT 36 (30)% (mean (SD)) of the diastolic interval was identified. Thirty eight VT morphologies were ablated using 154 radiofrequency energy applications. Successful ablation was achieved by 77% of radiofrequency within diastolic activation identified by the non-contact system and was significantly more likely to ablate VT than radiofrequency at the VT exit, or remote from diastolic activation. Over a mean follow up of 1.5 years, 14 patients have had no recurrence of VT and only two target VTs have recurred. Five patients have had recurrence of either slower non-sustained, undocumented or fast non-target VT. Five patients have died, one from tamponade from a pre-existing temporary pacing wire, and four from causes unrelated to the procedure. CONCLUSION: The non-contact system can safely be used to map and ablate haemodynamically stable VT with low VT recurrence rates. It is yet to be established whether this system may be applied with equal success to patients with haemodynamically unstable VT.

Adult↗

Simultaneous endocardial mapping in the human left ventricle using a noncontact catheter: comparison of contact and reconstructed electrograms during sinus rhythm.

BACKGROUND: Catheter ablation of ventricular tachycardia is limited in part by difficulty in identifying suitable sites for ablation. A noncontact multielectrode array (MEA) has been developed that allows reconstruction of 3360 electrograms, using inverse-solution mathematics, that are superimposed onto a computer-simulated model of the endocardium. This study assesses the accuracy of timing and morphology of reconstructed unipolar electrograms compared with contact unipolar electrograms from the same endocardial site. METHODS AND RESULTS: The MEA was deployed in the left ventricles of 13 patients (end-diastolic diameters, 61.7+/-8.4 mm [mean+/-SD]). We recorded contact electrograms at 76 points equatorial and 32 points nonequatorial to the MEA during sinus rhythm using a catheter-locator signal to record direction and distance from the MEA. Morphology (cross-correlation) and timing of maximum -dV/dt of contact and reconstructed electrograms were compared at different distances from the MEA center to endocardium (M-E) and from the MEA equatorial plane. For equatorial data, the M-E was 32.12+/-12.12 mm. The timing of reconstructed with respect to contact electrograms was -1.94+/-7.12 ms for M-E <34 mm and -14.16+/-19.29 ms at M-E >34 mm (P<0.001). Cross-correlation of electrograms was 0.87+/-0.12 (95% CI, 0.84 to 0.91) and 0.76+/-0.18 (95% CI, 0.69 to 0.83) for M-E <34 mm and >34 mm, respectively. Nonequatorial points were 32.33+/-10.81 mm (range, 16.9 to 55.6 mm) from the MEA equatorial plane; electrogram timing difference was -8.97+/-15.75 ms and was unrelated to this distance from the equator. CONCLUSIONS: This noncontact mapping system accurately reconstructs endocardial unipolar electrograms from the human left ventricle. At M-E distances >34 mm, timing accuracy of reconstruction decreases.

Adult↗

Characteristics of sinus rhythm electrograms at sites of ablation of ventricular tachycardia relative to all other sites: a noncontact mapping study of the entire left ventricle.

INTRODUCTION: Regions of the diseased ventricle that activate abnormally during sinus rhythm (SR) may be the areas of slow and disorganized conduction that form the diastolic pathway through which reentry may occur during ventricular tachycardia (VT). METHODS AND RESULTS: We examined features of electrograms recorded during SR that might indicate a site suitable for ablation of VT using a noncontact mapping system, which enables reconstruction of > 3,000 electrograms. Preablation SR electrogram characteristics at sites of successful radiofrequency ablation (RFA) were examined in 13 patients with 53 VTs. Timing of onset, lateness of activity, electrogram duration, and number of baseline crossing events of reconstructed electrograms at the sites of successful RFA were compared with the electrograms of latest onset, latest activity, longest duration, and most baseline crossing events of all ventricular sites. Onset of activation at sites of successful RFA were 26.9+/-25.2 msec (mean +/- SD) earlier than (and 2.9+/-1.7 cm away from) the site of latest onset of SR activation. Electrogram duration at sites of successful RFA was 83%+/-14.6% of (and 4.3+/-1.8 cm away from) the longest electrogram. The baseline crossing events at sites of successful RFA were 53%+/-22% of (and 4.9+/-1.9 cm away from) the most fractionated electrogram. The latest activity at sites of successful RFA was 21.6+/-24.8 msec earlier than (and 4.3+/-1.6 cm away from) the site of latest activity. CONCLUSION: Although the site of latest onset of endocardial activation during SR proved to be the most sensitive indicator, the characteristics of SR electrograms did not usefully predict successful ablation sites.

Adult↗

Amiodarone and the thyroid: a practical guide to the management of thyroid dysfunction induced by amiodarone therapy.

Amiodarone induces predictable changes in thyroid function tests that are largely explicable in terms of the physiological effects of iodide excess and inhibition of deiodinase activity. Clinically relevant thyroid dysfunction is not uncommon during amiodarone therapy, and requires careful diagnosis and treatment. The diagnosis and management of thyrotoxicosis is probably best supervised by a specialist endocrinologist. Control of hypothyroidism can generally be achieved simply by the addition of T4 to the therapeutic regimen, ideally after an initial assessment by an endocrinologist. The frequency with which amiodarone causes thyroid and other complications serves to emphasize the need for rational prescribing and long-term cardiological follow up.

Amiodarone↗