Search PubMed⌕ Search

Biomedical subjects

D Villalta

Publications and source records attributed to D Villalta.

At least 19 recordsLinked to original sources

Low specificity of anti-tissue transglutaminase antibodies in patients with primary biliary cirrhosis.

The association between celiac disease (CD) and primary biliary cirrhosis (PBC) is well documented in medical literature; however, a high frequency of false positive results of the anti-transglutaminase (anti-tTG) test has been reported in patients with PBC. To verify if the positive results for anti-tTG autoantibody are false positives due to cross reactivity with mitochondrial antigens, we studied 105 adult patients affected with PBC, positive for anti-mitochondrial M2 antibodies. Anti-tTG IgA antibodies were studied by using six different immunoenzymatic assays that employ the tTG antigen obtained from different sources (human recombinant, placenta, red blood cells, and guinea pig liver). On the whole, 28 out of 105 PBC subjects tested positive for anti-tTG IgA antibodies, but only two were eventually found to be affected by CD; the other 26 were shown to be false positive. The specificity of the various antigenic substrates ranged from 88.5% of the human erythrocytes tTG to 97.1% of the human recombinant tTG. The results of this study showed that a true association between PBC and CD was present in only 2% of the patients and that, in most cases, the false positive results were attributable to the type of substrate utilized in the assay.

Adult↗

A prospective study of 1038 pregnancies on the predictive value of anti-annexin V antibodies for fetal loss.

Retrospective studies have demonstrated that anti-annexin V (anti-AnxV) antibodies are linked to miscarriage. Their predictive value is, however, unknown. We have carried out a prospective study to evaluate the relationship between anti-AnxV antibodies and the pregnancy outcome. A serum sample was taken from 1038 consecutive healthy women at the beginning of pregnancy. IgG and IgM anti-AnxV antibodies were measured by an ELISA method. The cutoff value was set at 5 units for both IgG and IgM. Out of 1038 women, 116 (11.4%) had a miscarriage by the 22nd week; 10 were lost to follow-up, 10 had an induced abortion, 6 had a preterm delivery, and 896 carried their pregnancy through to term. An adverse outcome of the pregnancy proved to be directly related to the number of previous miscarriages (P = .008) and the age of the woman (P = .002). IgG and IgM anti-AnxV were present in 25% and 27% of the women who miscarried, and in 23% and 28% of those who gave birth (mean antibody concentration IgG, 4.2 vs. 4.4 U/mL; IgM, 3.7 vs. 3.5 U/mL). IgG and IgM anticardiolipin and anti-beta(2)GPI, together with antinuclear, antithyroperoxidase, and antithyroglobulin antibodies, were also measured in the 116 sera of the women with miscarriage and in an equal number of women who gave birth. Their positivity or level proved not to be useful in discriminating between the risk of miscarriage and term delivery. This large-scale prospective study demonstrates that the presence of IgG and IgM anti-AnxV antibodies, when measured in healthy women, does not give a positive predictive lead towards the possibility of a miscarriage, and it is not useful in evaluating the risk of miscarriage at the beginning of pregnancy.

Abortion, Spontaneous↗

Accuracy of semiquantitative immunoenzymatic methods in quantitation of anti-topoisomerase I (Scl-70) antibodies.

Reports of a possible correlation between anti-Scl-70 antibody concentration and clinical manifestations in systemic sclerosis patients have recently appeared in the scientific literature. The goal of our study was to evaluate, by means of a multicenter study, the analytical reliability of immunoassay systems in the quantitative measurement of Scl-70 antibodies. Three blind samples (H, M, L) at different anti-Scl-70 antibody concentrations, and a low concentration antibody serum (LPC) used as a common calibrator, were sent three times in a 6-month time span to 39 Italian clinical laboratories. Each laboratory was asked to calculate dosages following the enzyme-linked immunosorbent assay (ELISA) method they used and report the optical density values of each sample (ODs), of the cutoff serum provided by the manufacturer of the kit used (ODco) and of LPC (ODLPC). The overall analytical imprecision (between methods and between laboratories) of the three different determinations of the values respectively expressed in ODs, ODs/ODco and ODs/ODLPCratio was 47.1, 52.8 and 34.0% for sample H, 56.2, 47.4% and 34% for sample M and 84.6, 86.0 and 86.6% for sample L. The average intra-method analytical imprecision was, respectively, 20.7, 29.8 and 18.6% for sample H, 24.6, 26.5 and 19.3% for sample M, and 30.6, 28.1 and 20.2% for sample L. The commercial ELISA methods currently used to determine the presence of anti-Scl-70 autoantibodies show considerable differences in the quantitative determination. The best results for reproducibility analyses have been obtained when the values were expressed as a ratio between the ODs of the sample and of the common calibrator (ODs/ODLPC). Forward-looking clinical studies that can clarify the usefulness of quantitative determination of anti-Scl-70 antibodies in the monitoring of diffuse scleroderma patients can be performed only when standard serum with a known antibody concentration and calibration curves for quantitative ELISA measurements are made available.

Autoantibodies↗

Antinucleosome antibodies in SLE: a two-year follow-up study of 101 patients.

We prospectively analyzed the diagnostic sensitivity and specificity as well as the clinical relevance of antinucleosome antibodies in SLE. One hundred and one consecutive SLE patients were followed for 3 years. Three serial serum samples from each patient were tested for antinucleosome antibodies by ELISA (optimum cut-off value 10 U/ml), and for anti-dsDNA antibody (by ELISA and IIF on Crithidia luciliae), and anti-dsDNA avidity (by Scatchard plot analysis). Sera from 100 healthy individuals (HI), 35 patients with systemic sclerosis (SSc), 30 with primary Sjögren's syndrome (SS), 20 with rheumatoid arthritis (RA) and 48 with infectious diseases (ID), were assayed as controls. SLE activity and damage were evaluated using the ECLAM score and the SLICC/ACR index. At baseline, antinucleosome antibodies were found in 87 patients with SLE (86.1%), in 8 patients with SSc (22.8%), in 2 HI (2%), and in 1 ID (2.1%). The sensitivity and specificity of antinucleosome testing for SLE were 86.1% and 95.3%, respectively. The prevalence of antinucleosome antibodies in SLE was significantly higher than that of anti-dsDNA antibodies, with a correlation between them. No relevant relationship was found between antinucleosome antibodies and disease features, including renal involvement, disease activity, and disease damage. During follow-up, no significant variation was observed in antinucleosome level, nor in anti-dsDNA antibody level or avidity. We conclude that antinucleosome antibodies are commonly found in SLE. Low antibody levels can be detected in SSc, whereas medium/high levels are highly specific for SLE. Their clinical relevance during the disease course and utility for monitoring the individual patient seem to be poor.

Adult↗

Bee moth (Galleria mellonella) allergic reactions are caused by several thermolabile antigens.

BACKGROUND: Exposure and contact with bee moth (Galleria mellonella) larvae (Gm) can cause an allergic reaction both in anglers and breeders. We described the case of an amateur fisherman who experienced an allergic reaction using Gm but not using heat-treated Gm (h-Gm) (mummies). The aim of this study was to demonstrate by immunoblotting and radioallergosorbent test (RAST)-inhibition experiments the loss of allergenic epitopes in h-Gm extracts. METHODS: Galleria mellonella larvae and h-Gm were homogenized and extracted at 10% (w/v) in 0.5 M phosphate-buffered saline, pH 7.4 containing 0.5% NaN(3) for 16 h at 4 degrees C. Gm and h-Gm extracts were electrophoresed in a 10% polyacrylamide precast Nupage Bis-Tris gel at 180 mA for 1 h and the resolved proteins stained with 0.1% Coomassie brilliant blue and the molecular weight calculated. For the immunoblotting detection of allergenic components the resolved extracts were transferred onto a nitrocellulose membrane and incubated with the patient's serum. Bound specific-IgE was detected by peroxidase-conjugated anti-human IgE. RAST inhibition experiments were performed according to the Ceska method. RESULTS: The protein profile of Gm and h-Gm extracts resulted markedly different in number, intensity and the position of bands, indicating that heat-treatment modifies the chemical-physical characteristics of the protein contents. The Gm extract showed a strong-coloured band at 73 kDa and more than 20 components ranging from 12 to 133 kDa; h-Gm showed two main band at 77 and 38 kDa and about 15 faint bands between 20 and 133 kDa apparently without any correspondence to the bands present in the Gm extract. Immunoblotting with the patient's serum demonstrated several bands of reactivity with the Gm extract ranging from 20 to 100 kDa and no recognizable bands, but only a diffuse smear with h-Gm. When used in a RAST inhibition experiment the h-Gm extract demonstrated an inability to compete with the Gm one for the binding to patient's IgE serum. CONCLUSIONS: The h-Gm seems to lose the allergenic epitopes and has two advantages for anglers: to avoid new possible sensitizations as well as allergic symptoms in sensitized people, without interfering with their skills and satisfaction in their fishing performance.

Adult↗

Analytical and diagnostic accuracy of "second generation" assays for thyrotrophin receptor antibodies with radioactive and chemiluminescent tracers.

AIMS: To investigate the analytical and diagnostic accuracy of thyrotrophin (TSH) receptor antibody assays using recombinant human TSH receptors. METHODS: Sera from 68 patients with Graves' disease, 23 patients with autoimmune thyroiditis, and 119 healthy controls were evaluated in four different laboratories using both radioactive and chemiluminescent tracers. Functional sensitivity, interlaboratory precision, optimal cutoff values for Graves' disease, and the correlation between the two methods were evaluated. RESULTS: Functional sensitivity was 0.98 IU/litre for both assays. Interlaboratory precision, expressed as per cent coefficient of variation over a wide range of antibody concentrations, varied from 5.7% to 15.1% for the radioligand, and from 6.6% to 19.9% for the chemiluminescence assay. The two methods (radioactive and chemiluminescent) were closely correlated. All the sera from untreated or relapsing patients with Graves' disease gave TSH receptor antibody values above 2.1 IU/litre, whereas in none of the healthy controls did values exceed 2.5 IU/litre. Receiver operating curve analysis allowed an optimal cutoff point to be defined at 1.99 IU/litre, according to a sensitivity of 100% and specificity of 99.1%. CONCLUSIONS: These data show the high analytical and diagnostic accuracy of the human TSH receptor assays, both with radioactive and chemiluminescent tracers, when both functional sensitivity and interlaboratory reproducibility are considered. These two methods could be proposed as first line diagnostic markers for Graves' disease.

Adult↗

IgA and IgG tissue transglutaminase antibodies in systemic lupus erythematosus.

Systemic lupus erythematosus (SLE) and coeliac disease (CD) are diseases of an autoimmune origin that share the human leukocyte HLA-B8 and HLA-DR3 histocompatibility antigens, yet the co-association of CD with SLE is mainly based on case reports. Thus, the real prevalence of CD in SLE is unclear. The aim of this study was to determine the prevalence of antitissue transglutaminase (anti-tTG) in SLE and the relation between SLE and CD. In this case-control study, 100 patients with SLE, and 120 healthy subjects were studied. Sera from all participants were analysed for the presence of IgA and IgG anti-tTG antibodies using a human recombinant tissue transglutaminase (tTG) immuno-enzymatic assay. Anti-tTG positive patients and controls were further tested for antiendomysial (EMA) antibodies by an indirect immunofluorescence and HLA typing (DQalpha1*0501-DQbeta1*0201 allele determination). Subjects who had EMA or the mentioned allele, underwent duodenal biopsy to confirm a possible diagnosis of CD. Anti-tTG antibodies (IgA or IgG isotypes) were found in three of the 100 SLE patients (overall prevalence of 3%): one had the IgA and two the IgG isotypes. Only 1 of 120 healthy subjects (0.8%) had a low positive reaction for IgA anti-tTG. Only the IgA anti-tTG positive SLE patient was diagnosed as having CD based on a positive IgA-EMA and small bowel biopsy findings. The two IgG anti-tTG positive SLE patients and the IgA anti-tTG positive healthy subject were classified as false positives (EMA negative and HLA DQalpha1*0501-DQbeta1*0201 allele negative). In conclusion, anti-tTG antibodies were found at a low rate in SLE patients and mostly did not indicate the presence of CD. Thus, serological screening for CD is not recommended in SLE, unless a clinical suspicion of CD is present.

Adolescent↗

IgA and IgG tissue transglutaminase antibody prevalence and clinical significance in connective tissue diseases, inflammatory bowel disease, and primary biliary cirrhosis.

An association between celiac disease (CD) and other autoimmune diseases such as connective tissue diseases (CTD), inflammatory bowel diseases (IBD), and primary biliary cirrhosis (PBC) has been reported in several studies. However, a high rate of false positives in autoantibody testing was noted, especially when tissue transglutaminase (tTG) from guinea pig liver was used. Thus, the real prevalence of CD in CTD, IBD, and PBC is unclear. In a case-control study, 400 patients with CTD, 170 with IBD, 48 with PBC, and 120 healthy subjects were investigated for CD by the analysis of IgA and IgG tTG antibodies using the more specific human recombinant tTG immunoenzymatic assay. Patients and controls with positive findings were further tested for antiendomysial antibodies by indirect immunofluorescence and HLA typing, and those found positive by either of these tests underwent duodenal biopsy to confirm a possible diagnosis of CD. Twelve patients were positive for IgA or IgG tTG antibodies, showing an overall prevalence of 1.9%. Only 1 healthy subject (0.8%) had a low level positive reaction for IgA anti-tTG. Among the 12 patients and the healthy subject, only 2 (1 SLE and 1 ulcerative colitis patient) were subsequently confirmed to be affected with CD by positive EMA, HLA, and small bowel biopsy findings. The highest rate of false positives was found in PBC patients (10.4%). For these reasons, serological screening testing for CD is not recommended in CTD patients or in subjects affected with IBD or PBC, unless there is a relevant clinical suspicion of CD.

Adult↗

The role of antitissue transglutaminase assay for the diagnosis and monitoring of coeliac disease: a French-Italian multicentre study.

AIMS: Tissue transglutaminase (tTG) was recently identified as the major autoantigen in coeliac disease. The aim of this multicentre study was to evaluate the impact of a new immunoenzymatic assay for the detection of IgA anti-tGT antibodies. METHODS: Seventy four Italian and French clinical laboratories participated in this study; anti-tTG IgA with an enzyme linked immunosorbent assay (ELISA) method using guinea pig liver extract as the coating antigen, anti-endomysium IgA autoantibodies (EMA), and total serum IgA were determined in 7948 patients, 1162 of whom had coeliac disease (737 untreated cases and 425 on a gluten free diet). A proportion of the sera were then sent to a reference laboratory for anti-tTG retesting with an ELISA method using recombinant human tTG antigen. RESULTS: Seven thousand four hundred and fifty eight (93.8%) sera were EMA/antiguinea pig tTG concordant (positive or negative); 490 (6.2%) were non-concordant. The sensitivity of EMA and antiguinea pig tTG in the 737 untreated patients with coeliac disease was 92.1% and 94.8%, respectively, and the specificity was 99.8% and 99.2%, respectively. Retesting of the discordant sera showed that of the 162 sera classified as EMA negative/antiguinea pig tTG positive, only 49 were positive for human recombinant anti-tTG, and that 39 of these were also EMA positive. Furthermore, of the 36 sera classified as EMA positive/antiguinea pig tTG negative, only two were confirmed as EMA positive. CONCLUSIONS: The antiguinea pig tTG assay is more sensitive but less specific than EMA, whereas the antihuman recombinant tTG assay is far more specific and just as sensitive as antiguinea pig tTG. Testing for EMA presents considerable interpretative problems and is difficult to standardise.

Adolescent↗

Anti-dsDNA antibody avidity determination by a simple reliable ELISA method for SLE diagnosis and monitoring.

High avidity anti-dsDNA antibodies are more specific for SLE diagnosis, and more closely associated with renal involvement than intermediate or low-affinity anti-dsDNA antibodies. ELISA methods are largely used to detect anti-dsDNA, but their high sensitivity is inversely related to specificity because they also detect low avidity antibodies. We developed an ELISA assay based on the law of mass action and the competitive binding of dsDNA in solution and coated to microwells with anti-dsDNA antibodies. A simplified Scatchard plot analysis system was used to measure anti-dsDNA antibody avidity which was expressed as apparent affinity constant (Kaa), and quantified in liters per unit (I/U). We prospectively studied 101 consecutive SLE patients, who were followed for 3 years; three serum samples were sequentially collected from each patient during follow-up for determination of IgG anti-dsDNA antibody concentration, and anti-dsDNA avidity. SLE disease activity was estimated using the European Consensus Lupus Activity Measure (ECLAM) index. Sera from 100 healthy subjects and 133 patients with other connective tissue diseases or infectious diseases were also assayed as controls. The mean Kaa in SLE patients was 65.2 +/- 47.3 l/U, with no variations over time. Anti-dsDNA-positive SLE patients had higher Kaa values (79.1 +/- 46.8) than anti-dsDNA negative patients (27.2 +/- 20.1; P < 0.001). No correlation emerged between anti-dsDNA avidity and the ECLAM activity index score. Avidity was significantly higher in patients with renal involvement vs patients without this complication (78.2 +/- 50 vs 59.9 +/- 45.6 l/U; P = 0.0013). This simple ELISA method could be very useful in the diagnostic phase to differentiate high avidity anti-dsDNA autoantibodies that are characteristically found in SLE patients from low avidity antibodies that can also be found in other inflammatory diseases. Moreover, our data confirm the predictive value of high avidity anti-dsDNA antibodies for the development of lupus nephritis.

Adult↗

Evaluation of a new automated enzyme fluoroimmunoassay using recombinant plasmid dsDNA for the detection of anti-dsDNA antibodies in SLE.

ELISA methods to detect anti-double-stranded DNA (anti-dsDNA) antibodies are highly sensitive, but are less specific for the diagnosis of SLE than the immunofluorescence test on Crithidia luciliae (CLIFT) and the Farr assay because they also detect low-avidity antibodies. This study evaluated the specificity, sensitivity, positive predictive value (PPV), and negative predictive value (NPV) of a new automated fluoroimmunoassay (EliA dsDNA; Pharmacia, Freiburg, Germany). We compared the results with those obtained using a commercial CLIFT and an in-house anti-dsDNA IgG ELISA method, and verified its putative ability to detect only high-avidity anti-dsDNA antibodies. Sera from 100 SLE patients and 120 controls were studied. The control group included 20 healthy donors, 70 patients with other rheumatic diseases (32 systemic sclerosis (SSc); 18 primary Sjögren syndrome (pSS), 20 rheumatoid arthritis (RA)), and 30 patients with various infectious diseases (ID). Anti-dsDNA avidity was estimated using an ELISA method based upon the law of mass action, and a simplified Scatchard plot analysis for data elaboration; the apparent affinity constant (Kaa) was calculated and expressed as arbitrary units (L/U). Sensitivity, specificity, PPV, and NPV for SLE were 64%, 95.8%, 93.8% and 72.7%, respectively, for the EliA anti-dsDNA assay; 55%, 99.2%, 98.5%, and 68.8%, respectively, for the CLIFT; and 64%, 93.3%, 90.6%, and 72.3%, respectively, for the in-house ELISA. Although EliA anti-dsDNA was positive mainly in SLE patients with high- (Kaa>80 L/U) and intermediate- (Kaa 30-80 L/U) avidity antibodies (45.3% and 49.9%, respectively), it was also positive in five (7.8%) SLE patients with low-avidity anti-dsDNA antibodies, and five controls (three SSc, one pSS, and one ID) (mean Kaa = 16.4 +/- 9.04 L/U). In conclusion, EliA anti-dsDNA assay showed a higher sensitivity than the CLIFT, and a good specificity and PPV for SLE. Its putative ability to detect only high-avidity anti-dsDNA antibodies remains questionable.

Adult↗

New coupled-particle light-scattering assay for detection of Ro/SSA (52 and 60 kilodaltons) and La/SSB autoantibodies in connective tissue diseases.

The diagnostic and analytical performance of the coupled-particle light-scattering assay in detecting anti-Ro/SSA autoantibodies (the 60-kDa [Ro60] and the 52-kDa [Ro52] antibodies) and anti-La/SSB autoantibodies was evaluated. The antigens were obtained by recombinant DNA procedures to include the most immunogenic epitopes for each protein by using a prokaryotic expression system. Serum samples from 151 patients with connective tissue diseases and 52 control subjects (including patients with viral infections, patients with Lyme disease, and healthy subjects) were studied. Sensitivities for detection of anti-Ro/SSA and anti-La/SSB were 88.2 and 95.2%, respectively; specificities were 97.6 and 98.1%, respectively. The intra-assay coefficient of variation (CV) ranged from 4.3 to 10.9% for anti-Ro/SSA and from 2.8 to 12.5% for anti-La/SSB; interassay CVs ranged from 6.5 to 13.2% and from 8.2 to 14.5%, respectively. Among the anti-Ro/SSA-positive samples, Ro60 was recognized by 66% of the test sera and Ro52 was recognized by 95% of the test sera. Thirty-four percent of the Ro/SSA-positive sera were reactive only with the Ro52 antigen, indicating that anti-Ro52 is the most common antibody specificity recognized by anti-Ro/SSA autoantibodies. No differences were found between the prevalences of anti-Ro60 and anti-Ro52 in relation to systemic lupus erythematosus or Sjögren's syndrome. The results of the present study indicate that this new immunoassay is an efficient diagnostic tool for the detection of anti-Ro/SSA and anti-La/SSB antibodies in patients with autoimmune disorders.

Antibodies, Antinuclear↗

Diagnostic accuracy of the anti-citrulline antibody assay for rheumatoid arthritis.

BACKGROUND: Rheumatoid arthritis (RA) is the most common autoimmune rheumatic disease, but specific and practicable tests for its diagnosis are lacking. We evaluated the diagnostic accuracy of a new commercial ELISA in detecting anti-cyclic citrullinated peptide (CCP) antibodies for the diagnosis of RA. METHODS: Anti-CCP antibodies were determined in 330 serum samples: 98 from RA patients and 232 from controls, including patients with connective tissue diseases, other rheumatic diseases, viral infections, Lyme disease, autoimmune thyroiditis, cancer, and monoclonal gammopathy, and sex- and age-matched healthy subjects. Intra- and interassay CVs were 5-13% and 9-17%, respectively. Rheumatoid factor (RF) was also assayed in every sample, and results were compared to anti-CCP for sensitivity and specificity. RESULTS: At a cutoff value of 50 units, sensitivity was 41% (confidence interval, 31-50%) and specificity was 97.8% (95-100%). Anti-CCP-positive RA patients had a mean antibody concentration of 1100 units (range, 57-3419 units), and anti-CCP-negative RA patients and controls had mean values of 7.6 and 6.8 units, respectively (range, 1-39 units). The area under the ROC curve was 0.71 (95% confidence interval, 0.63-0.78). RF had a higher sensitivity (62%) and a lower specificity (84%) than anti-CCP. When the two antibodies were used together, specificity was 99.6%. CONCLUSION: Anti-CCP antibody testing may be useful if performed concomitantly with RF assay to diagnose patients with suspected early RA.

Adult↗

[Laboratory diagnosis of autoimmune thyroid disease].

Assay of the anti-thyroperoxidase (TPO), anti-thyroglobulin (Tg), and anti-TSH receptor antibodies constitutes the basis of the laboratory diagnostic work-up for autoimmune thyroid diseases. However, although these antibodies have been routinely assayed in serum for more than 40 years with increasingly reliable methods, it still exists a wide analytical variability that influences their correct diagnostic use. We analysed the biochemical, physiopathological and clinical aspects of the thyroid antigen-anti body systems, and propose the following guidelines for using autoantibody tests and analytical assay methods: a) assay of anti-TPO with third generation ultrasensitive method should constitute the main test for the diagnosis of autoimmune thyroid diseases. Assay of anti-M antibodies should be considered obsolete because even purified microsome preparations contain traces of contaminants (Tg and other antigens) that make the test aspecific; b) assay of anti-Tg antibodies may be limited to patients with suspect AITD and negative for anti-TPO antibodies, and patients undergoing thyroglobulin assay, because anti-Tg autoantibodies may interfere in the assay of the molecule in the immunometric test; c) assay of the anti-TSH receptor antibodies is used to diagnose Basedow's disease, and atrophic chronic thyroiditis; d) it is appropriate to use normal reference values adjusted for age and gender.

Antigen-Antibody Reactions↗

Sensitivity and specificity of immunological methods for the detection of anti-topoisomerase I (Scl70) autoantibodies: results of a multicenter study. The Italian Society of Laboratory Medicine Study Group on the Diagnosis of Autoimmune diseases.

BACKGROUND: The ability of immunometric methods to identify anti-topoisomerase I (Scl70) antibodies is controversial. We wished to quantify the performance of the currently available commercial systems for the assay of anti-topoisomerase I antibodies in a large multicenter study. METHODS: Fifty Italian clinical laboratories analyzed 36 serum samples: 27 from individuals with scleroderma/systemic sclerosis, and 9 from a control group. The scleroderma/systemic sclerosis samples were positive in our laboratories by both ELISA and immunoblot (IB), and the control samples were negative. The laboratories used 42 immunoenzymatic (ELISA), 21 IB, 3 counterimmunoelectrophoresis, and 2 dot-blot methods, produced by 23 different manufacturers. RESULTS: We obtained 2389 results. The ELISA methods showed 99.2% specificity and 97.2% sensitivity for detection of anti-Scl70 antibodies. For IB methods, specificity was 97.6% and sensitivity was 96.1%. The Western-blot method had poor analytical specificity (27% false positives for anti-extractable nuclear antigen antibodies other than anti-Scl70). CONCLUSIONS: Excluding Western blots, commercial ELISA and IB reagents as used in clinical laboratories have a sensitivity and a specificity >95% for determination of anti-Scl70 antibodies.

Autoantibodies↗

Automatic capture verification by charge-neutral sensing.

Automatic capture verification can prolong pulse generator longevity and increase patient safety. However, the detection of evoked response following pacing is complicated due to afterpotentials caused by polarization of electrodes. This study describes a new capture verification scheme, which neutralizes the charges between the pacing electrodes. The hypothesis of the charge-neutral sensing is that the afterpotentials in the ring and the tip are opposite in polarity when pacing in a bipolar mode between ring and tip. Summing the unipolar signals sensed at the tip and the ring should effectively cancel the afterpotentials. This scheme was implemented in an external computer based system and tested during pacemaker implant/replacement on 23 patients during VVI pacing (17 acutely implanted leads and 6 chronic leads). Surface ECG was recorded to provide a marker for capture and noncapture. The pacing voltage was gradually decreased until a noncapture beat was noted. To avoid fusion beats, the pacing rate was programmed approximately 50% higher than the intrinsic rate. The evoked response was high pass filtered and the integral average was calculated for both capture and noncapture beats. The system signal to noise ratio (SNR) was expressed as ratio of the minimum integral average of all capture beats to the maximum integral average of all noncapture beats. The system SNR was 8.6 +/- 1.3 (mean +/- S.E.M; range 1.5-22.8), indicating that the charge-neutral sensing method has, on average, a ninefold safety margin in providing capture verification. Further, evaluation is needed to fully assess this feature in patients with chronic leads.

Aged↗

[Detection of anti-ENA autoantibodies in patients with systemic connective tissue diseases. Analytical variability and diagnostic sensitivity of 4 methods].

This study was designed to assess the analytical sensitivity and rate of agreement between commercial methods and reagents, among the most used in Italy for the detection of autoantibodies to extractable nuclear antigens (ENA). Sixty-eight serum samples from patients with clinically diagnosed systemic rheumatic diseases were aliquoted and distributed to 4 hospital laboratories; three ELISA (Elias, Shield, Inova) and 1 immunoblot method (Euroimmun) were used. Overall agreement between the test reagents, for each anti-ENA specificity, was 69.1% for Ro/SSA, 83.3% for La/SSB, 70.6% for RNP, 73.5% for Sm, 91.1% for Jo1, and 82.3% for Scl70. Lack of specificity (i.e., false positive reactions) was the most important cause of low concordance. When the data were analysed according to the clinical diagnosis, total agreement and specificity improved. However, a significant difference in terms of sensitivity was observed in the SLE group (30 sera) for RNP (positivity ranged from 20% to 43%) and for Sm (from 7% to 37%), and in the Sjögren's syndrome group (13 sera) for anti-La/SSB (from 8% to 38%). Comparable data were obtained for anti-Ro/SSA (from 70% to 77%) both in the SLE and the Sjögren's syndrome group. Sensitivity of all 4 reagents was good in detecting anti-Scl70 autoantibodies in the 8 patients with diffuse systemic sclerosis, as well as anti-Jo1 autoantibody in the 5 polymyositis patients, with a 100% and a 95% agreement, respectively. These data suggest the need of a better standardization of commercial reagents and analytical procedures, and the opportunity that every laboratory should perform anti-ENA determination by at least two different methods, since none of the methods tested was completely reliable in detecting all anti-ENA autoantibody specificities.

Antibodies, Antinuclear↗