Search PubMed⌕ Search

Biomedical subjects

D T Martin

Publications and source records attributed to D T Martin.

At least 37 records · Page 2Linked to original sources

Impaired interval exercise responses in elite female cyclists at moderate simulated altitude.

The effect of hypoxia on the response to interval exercise was determined in eight elite female cyclists during two interval sessions: a sustained 3 x 10-min endurance set (5-min recovery) and a repeat sprint session comprising three sets of 6 x 15-s sprints (work-to-relief ratios were 1:3, 1:2, and 1:1 for the 1st, 2nd, and 3rd sets, respectively, with 3 min between each set). During exercise, cyclists selected their maximum power output and breathed either atmospheric air (normoxia, 20.93% O(2)) or a hypoxic gas mix (hypoxia, 17.42% O(2)). Power output was lower in hypoxia vs. normoxia throughout the endurance set (244+/-18 vs. 226+/-17, 234+/-18 vs. 221+/-25, and 235+/-18 vs. 221+/-25 W for 1st, 2nd, and 3rd sets, respectively; P< 0.05) but was lower only in the latter stages of the second and third sets of the sprints (452+/-56 vs. 429+/-49 and 403+/-54 vs. 373+/- 43 W, respectively; P<0.05). Hypoxia lowered blood O(2) saturation during the endurance set (92.9+/-2.9 vs. 95.4+/-1.5%; P<0.05) but not during repeat sprints. We conclude that, when elite cyclists select their maximum exercise intensity, both sustained (10 min) and short-term (15 s) power are impaired during hypoxia, which simulated moderate ( approximately 2,100 m) altitude.

Acids↗

Effect of fat adaptation and carbohydrate restoration on metabolism and performance during prolonged cycling.

For 5 days, eight well-trained cyclists consumed a random order of a high-carbohydrate (CHO) diet (9.6 g. kg(-1). day(-1) CHO, 0.7 g. kg(-1). day(-1) fat; HCHO) or an isoenergetic high-fat diet (2.4 g. kg(-1). day(-1) CHO, 4 g. kg(-1). day(-1) fat; Fat-adapt) while undertaking supervised training. On day 6, subjects ingested high CHO and rested before performance testing on day 7 [2 h cycling at 70% maximal O(2) consumption (SS) + 7 kJ/kg time trial (TT)]. With Fat-adapt, 5 days of high-fat diet reduced respiratory exchange ratio (RER) during cycling at 70% maximal O(2) consumption; this was partially restored by 1 day of high CHO [0.90 +/- 0.01 vs. 0.82 +/- 0.01 (P < 0.05) vs. 0.87 +/- 0.01 (P < 0.05), for day 1, day 6, and day 7, respectively]. Corresponding RER values on HCHO trial were [0. 91 +/- 0.01 vs. 0.88 +/- 0.01 (P < 0.05) vs. 0.93 +/- 0.01 (P < 0.05)]. During SS, estimated fat oxidation increased [94 +/- 6 vs. 61 +/- 5 g (P < 0.05)], whereas CHO oxidation decreased [271 +/- 16 vs. 342 +/- 14 g (P < 0.05)] for Fat-adapt compared with HCHO. Tracer-derived estimates of plasma glucose uptake revealed no differences between treatments, suggesting muscle glycogen sparing accounted for reduced CHO oxidation. Direct assessment of muscle glycogen utilization showed a similar order of sparing (260 +/- 26 vs. 360 +/- 43 mmol/kg dry wt; P = 0.06). TT performance was 30.73 +/- 1.12 vs. 34.17 +/- 2.48 min for Fat-adapt and HCHO (P = 0.21). These data show significant metabolic adaptations with a brief period of high-fat intake, which persist even after restoration of CHO availability. However, there was no evidence of a clear benefit of fat adaptation to cycling performance.

Adaptation, Physiological↗

A novel method utilising markers of altered erythropoiesis for the detection of recombinant human erythropoietin abuse in athletes.

BACKGROUND AND OBJECTIVE: The use of recombinant human erythropoietin (r-HuEPO) to enhance athletic performance is prohibited. Existing tests cannot readily differentiate between exogenous and endogenous EPO. Therefore the aim of our study was to investigate possible indirect detection of r-HuEPO use via blood markers of altered erythropoiesis. DESIGN AND METHODS: Twenty-seven recreational athletes were assigned to three groups prior to a 25 day drug administration phase, with the following protocols: EPO+IM group (n = 10), 50 Ukg(-1) r-HuEPO at a frequency of 3wk(-1), 100 mg intramuscular (IM) iron 1wk(-1) and a sham iron tablet daily; EPO+OR group (n = 8), 50 U.kg(-1) r-HuEPO 3wk(-1), sham iron injection 1wk(-1) and 105 mg of oral elemental iron daily; placebo group (n = 9), sham r-HuEPO injections 3wk(-1), sham iron injections 1wk(-1) and sham iron tablets daily. Each group was monitored during and for 4 weeks after drug administration. RESULTS: Models incorporating combinations of the variables reticulocyte hematocrit (RetHct), serum EPO, soluble transferrin receptor, hematocrit (Hct) and % macrocytes were analyzed by logistic regression. One model (ON-model) repeatedly identified 94-100% of r-HuEPO group members during the final 2 wk of the r-HuEPO administration phase. One false positive was recorded from a possible 189. Another model (OFF-model) incorporating RetHct, EPO and Hct was applied during the wash-out phase and, during the period of 12-21 days after the last r-HuEPO injection, it repeatedly identified 67-72% of recent users with no false positives. INTERPRETATION AND CONCLUSIONS: Multiple indirect hematologic and biochemical markers used simultaneously are potentially effective for identifying current or recent users of r-HuEPO.

Adult↗

Heart rate-perceived exertion relationship during training and taper.

BACKGROUND: Examine the heart rate-perceived exertion (HR-RPE) relationship under conditions of high-intensity training and taper. METHODS: Experimental design and participants: prospective with collegiate cyclists (n=11) completed six weeks of high-intensity interval training, followed by a one-week taper. INTERVENTIONS: participants completed a high-intensity training regimen along with graded exercise tests (GXT) throughout the training and the taper. MEASURES: heart rates (HR) and ratings of perceived exertion (RPE) were recorded following each stage of the GXTs. Scores on GXTs were also recorded. RESULTS: . The HR-RPE relationship during GXTs changed over the course of the training with greater RPEs for a given HR at the end of the training compared to the beginning. The most powerful predictors of the performance response to the taper were training induced changes in the HR-RPE relationship and decreases in HR for a given power output. Those individuals who reported higher RPEs for lower HRs were more likely to have better performance responses to taper (r=0.72) as were those who had larger changes in the HR-power output relationship (r=0.76). CONCLUSIONS: These results indicate that changes in the HR-RPE relationship during high-intensity training may be used to monitor the magnitude of overreaching that is necessary for a positive response to a taper. For coaches and athletes, the HR-RPE ratio may be a practical measure for monitoring an aspect of fatigue associated with high-intensity training.

Adult↗

Effects of a 12-day "live high, train low" camp on reticulocyte production and haemoglobin mass in elite female road cyclists.

The aim of this study was to document the effect of "living high, training low" on the red blood cell production of elite female cyclists. Six members of the Australian National Women's road cycling squad slept for 12 nights at a simulated altitude of 2650 m in normobaric hypoxia (HIGH), while 6 team-mates slept at an altitude of 600 m (CONTROL). HIGH and CONTROL subjects trained and raced as a group throughout the 70-day study. Baseline levels of reticulocyte parameters sensitive to changes in erythropoeisis were measured 21 days and 1 day prior to sleeping in hypoxia (D1 and D20, respectively). These measures were repeated after 7 nights (D27) and 12 nights (D34) of simulated altitude exposure, and again 15 days (D48) and 33 days (D67) after leaving the altitude house. There was no increase in reticulocyte production, nor any change in reticulocyte parameters in either the HIGH or CONTROL groups. This lack of haematological response was substantiated by total haemoglobin mass measures (CO-rebreathing), which did not change when measured on D1, D20, D34 or D67. We conclude that in elite female road cyclists, 12 nights of exposure to normobaric hypoxia (2650 m) is not sufficient to either stimulate reticulocyte production or increase haemoglobin mass.

Adult↗

Glycerol hyperhydration improves cycle time trial performance in hot humid conditions.

Eight competitive cyclists [mean peak oxygen consumption, (VO2(peak)) = 65 ml x min(-1) x kg(-1)] undertook two 60-min cycle ergometer time trials at 32 degrees C and 60% relative humidity. The time trials were split into two 30-min phases: a fixed-workload phase and a variable-workload phase. Each trial was preceded by ingestion of either a glycerol solution [1 g x kg(-1) body mass (BM) in a diluted carbohydrate (CHO)-electrolyte drink] or a placebo of equal volume (the diluted CHO-electrolyte drink). The total fluid intake in each trial was 22 ml x kg(-1) BM. A repeated-measures, double blind, cross over design with respect to glycerol was employed. Glycerol ingestion expanded body water by approximately 600 ml over the placebo treatment. Glycerol treatment significantly increased performance by 5% compared with the placebo group, as assessed by total work in the variable-workload phase (P < 0.04). There were no significant differences in rectal temperature, sweat rate or cardiac frequency between trials. Data indicate that the glycerol-induced performance increase did not result from plasma volume expansion and subsequently lower core temperature or lower cardiac frequencies at a given power output as previously proposed. However, during the glycerol trial, subjects maintained a higher power output without increased perception of effort or thermal strain.

Adult↗

Greater erythrocyte deformability in world-class endurance athletes.

Because athletes during endurance events require rapid uptake of oxygen, the ability of red blood cells (RBC) to move through capillaries may limit performance. Using ektacytometry, we determined whether RBC deformability (RCD) differed between elite road cyclists (n = 9) and sedentary controls (n = 5). Density profiles and standard hematological measurements were also performed. The deformability index (DI) was higher in the cyclists (0.723 +/- 0.027) compared with that in controls (0.619 +/- 0.040, P < 0.001). Cyclists also had a larger percentage of low-density RBCs (P < 0. 001), and mean cell volume (MCV) was also higher (P = 0.013). These findings are indicative of a larger proportion of "young" RBCs in the blood of elite cyclists and provide further evidence that the turnover of RBCs in endurance athletes is higher than in the general population. With a younger more deformable RBC population and providing the destruction does not exceed replacement, performance potential should be enhanced. Furthermore, examination of factors that contribute to increased RBC turnover in athletes may help us understand the mechanisms that cause RBC aging.

Adult↗

Serum ferritin and anemia in trained female athletes.

The aim of this study was to establish whether extremely low serum ferritin values in female athletes were associated with indications of iron deficiency anemia and whether serum ferritin values were influenced by the type of training or participants' body size. Hematological data collected during 6 years at the Australian Institute of Sport were reviewed to quantify changes in serum ferritin concentration associated with training and to establish whether decrements in serum ferritin were associated with any change in hemoglobin concentration, mean corpuscular volume, or mean corpuscular hemoglobin concentration. Mean serum ferritin concentrations of 7.5 microg x L(-1) were not associated with any indication of iron-deficiency anemia. Serum ferritin declined by approximately 25% with the onset of rigorous daily training (p < .01) whether training was predominantly weight-bearing or non-weight-bearing. Rowers had significantly higher ferritin concentrations than basketball players of similar stature (p=.02). We conclude that considerable background information such as the stage of training, specific sport, and previous blood results should be sought when interpreting serum ferritin concentrations in female athletes.

Anemia, Iron-Deficiency↗

Interval-dependent changes in left ventricular contractile state in lone atrial fibrillation and in atrial fibrillation associated with coronary artery disease.

In atrial fibrillation (AF), beat-to-beat changes in left ventricular (LV) systolic performance are caused by variations in filling (preload), aortic pressure (afterload), and ventricular inotropic or contractile state. These factors are known to be influenced by the preceding diastolic or RR interval (RR1), but the independent impact of variations in the pre-preceding RR interval (RR2) on contractile state is not well defined. This aspect was studied in 10 patients with lone AF and 8 with coronary artery disease by measuring LV peak ejection velocity (V[pe] Doppler echocardiography) in 80 to 100 consecutive cardiac cycles. V(pe) was plotted against RR1 for beats with a short RR2 and for beats with a long RR2. Such function-interval plots indicate a direct relation between V(pe) and RR1 (for RR1 = 500 to 1,000 ms). In lone AF, the slope (linear fit) of V(pe) versus RR1 was similar for short and long RR2 (slopes = 46 and 50 s[-1]). V(pe), calculated from best linear fit and a common RR1, was consistently higher when RR2 was short than when it was long. At an RR1 = 750 ms, V(pe) (% of max) was 87 +/- 6% when RR2 was short versus 76 +/- 6% when RR2 was long, p <0.05. Results were similar in patients with coronary artery disease and the observed interval-dependent potentiation of contractile state was preserved in patients with a low ejection fraction. By comparing V(pe) at a common RR1, the effects of time-dependent changes in LV preload and afterload are minimized if not abolished. Thus, differences in V(pe) reflect differences in contractile state caused by variations in RR2. Data confirm interval-dependent alterations in contractile state that are likely an expression of the force-frequency relation. Studies of LV function in AF should incorporate a consideration of cycle length-dependent changes in LV contractile state.

Aged↗

Undersensing of ventricular fibrillation in a noncommitted nonthoracotomy cardioverter defibrillator system.

OBJECTIVE: Evaluation of the impact of undersensing on VF detection time and the relationship of undersensing to the programmed shock energy. BACKGROUND: Failure to reconfirm an ongoing arrhythmia due to undersensing by a noncommitted ICD might prolong the time to therapy. METHODS: We measured initial detection times and redetection times at predischarge and at 2 and 6 months in 29 patients (22 men, mean age 60 years) with a noncommitted nonthoracotomy ICD. Telemetry data and output markers were used to analyze each induction. RESULTS: Undersensing leading to failure to reconfirm was present in 44 (11.1%) of 398 episodes of sustained VF and prolonged significantly the median initial detection time from 2.3 seconds (25th and 75th percentiles: 2 and 2.6 s, respectively) to 5.45 seconds (4.3 and 7.35 s, P < 0.0001). One episode required external defibrillation after reconfirmation failure occurred during charging; the total detection time prior to shock was 46 seconds. In a subset of 87 episodes with failed first shocks, the initial detection time was 2.3 seconds (2.1 and 2.8 s) and the redetection time 3 seconds (2.5 and 4.77 s, P < 0.0001). The presence of undersensing prolonged the redetection from 2.6 seconds (2.35 and 3.1 s) to 5.4 seconds (4.53 and 7.35 s, P < 0.0001). Undersensing was more prevalent during the redetection period (P = 0.004) and in episodes of sustained VF in which the first shock energy was higher than 15 J (19.7% vs 5.8%, P < 0.0001). CONCLUSIONS: In this automatic defibrillator system, undersensing occurs in 11% of the sustained VF inductions and prolongs detection time significantly. Redetection is longer than initial detection mostly due to the presence of undersensing, the frequency of which is proportional to the programmed energy. The clinical significance of this finding is unknown.

Cardiac Pacing, Artificial↗

Combined use of non-thoracotomy cardioverter defibrillators and endocardial pacemakers.

OBJECTIVE: To study the potential interactions in patients with endocardial permanent pacemakers and non-thoracotomy implantable cardioverter defibrillator (ICD) systems. DESIGN: Case series and cohort study. SETTING: Tertiary referral centre. PATIENTS: Fifteen consecutive patients with both endocardial pacemakers (12 dual chamber and three single chamber) and non-thoracotomy ICD systems. MAIN OUTCOME MEASURES: Detection inhibition of induced ventricular fibrillation; double counting; and pacemaker function after shocks. In the evaluation of detection inhibition, 124 VF inductions were analysed for detection duration compared with induced VF episodes in controls with an ICD but without a pacemaker. RESULTS: Two patients (13%) showed detection inhibition of VF and required pacemaker system change at the time of the ICD implant. With the final lead position, despite frequent pacemaker undersensing of VF, ICD detection of VF was not inhibited during any induction, and neither initial detection nor redetection times for VF were different from controls. Double/triple counting of pacemaker artefact and evoked electrogram was noted in three patients (20%). In two, this was remedied during the implantation procedure, and in the other it was abolished when amiodarone treatment was discontinued. Pacemaker function was affected by ICD discharges in two patients, one who showed postshock atrial undersensing and loss of capture, and another whose pacemaker reverted to VVI mode. CONCLUSIONS: When careful testing is performed at implantation to detect and remedy device interactions, non-thoracotomy ICD treatment and endocardial pacemakers can be used safely in combination.

Adult↗

Circadian variation in defibrillation energy requirements.

BACKGROUND: Reports have demonstrated a circadian variation in the incidence of acute myocardial infarction, ventricular arrhythmias, and sudden cardiac death. We tested the hypothesis that a similar circadian variation exists for defibrillation energy requirements in humans. METHODS AND RESULTS: We reviewed the time of defibrillation threshold (DFT) measurements in 134 patients with implantable cardioverter-defibrillators (ICDs) who underwent 345 DFT measurements. The DFT was determined in 130 patients at implantation, in 121 at a 2 months, and in 94 at 6 months. All patients had nonthoracotomy systems. The morning DFT (8 AM to 12 noon) was 15.1 +/- 1.2 J compared with 13.1 +/- 0.9 J in the midafternoon (12 noon to 4 PM) and 13.0 +/- 0.7 J in the late afternoon (4 to 8 PM), P < .02. In a separate group of 930 patients implanted with an ICD system with date and time stamps for each therapy, we reviewed 1238 episodes of ventricular tachyarrhythmias treated with shock therapy. To corroborate the hypothesis that energy requirements for arrhythmia termination vary during the course of the day, we plotted the failed first shock frequency for all episodes per hour. There was a significant peak in failed first shocks in the morning compared with other time intervals (P = .02). CONCLUSIONS: There is a morning peak in DFT and a corresponding morning peak in failed first shock frequency. This morning peak resembles the peaks seen in other cardiac events, specifically sudden cardiac death. These findings have important implications for appropriate ICD function, particularly in patients with marginal DFTs.

Aged↗

Increase in defibrillation threshold in non-thoracotomy implantable defibrillators using a biphasic waveform.

We have previously reported a chronic increase in defibrillation threshold in a non-thoracotomy implantable cardioverter-defibrillator (ICD) system using monophasic waveforms. To determine if this phenomenon is related to the lead system or the waveform used, we studied the chronic defibrillation threshold in consecutive patients receiving an ICD capable of delivering biphasic waveforms with the same lead system previously evaluated. Twenty-five patients received an ICD with biphasic shock waveform and have been followed for 4 to 15 months. All have undergone defibrillation threshold measurements using the identical testing protocol with biphasic waveforms at implant and at 2 months. Coronary artery disease was present in 15, idiopathic dilated cardiomyopathy in 9, and valvular heart disease in 1. The presenting arrhythmia was ventricular fibrillation in 11, ventricular tachycardia in 10, and syncope with inducible ventricular tachycardia in 4. The configuration of the shocking electrodes was randomized; the lead-only configuration was used in 14 patients (56%), and a subcutaneous patch was used in the remaining patients. Mean defibrillation threshold using a step-down technique was 9.8 +/- 1.0 J at implant, 13.2 +/- 1.6 J at 2 months, and 12.4 +/- 1.5 J at 6 months (p = 0.01 by analysis of variance). There was no change in clinical status, cardiac size, radiographic lead position, or impedance between implant and 2 months. These findings suggest the increase in defibrillation threshold in this ICD system is not related to the type of waveform used, but rather is a feature of non-thoracotomy as opposed to epicardial electrodes.

Adult↗

Successful laparoscopic repair of paraesophageal hernia.

OBJECTIVE: To evaluate prospectively the safety and efficacy of laparoscopic surgical techniques in the repair of types II and III paraesophageal hernias. DESIGN: Case series. SETTING: Tertiary-care, university-affiliated hospitals. PATIENTS: Twelve consecutive patients undergoing elective laparoscopic repair of type II or type III paraesophageal hernias. Patients were available for follow-up for 1 to 17 months postoperatively. INTERVENTIONS: All patients underwent laparoscopic paraesophageal hernia reduction and repair. Eight patients with gastroesophageal reflux disease underwent concurrent laparoscopic Nissen fundoplication. MAIN OUTCOME MEASURES: Operative times, operative complications, and estimated blood loss were recorded. Postoperative outcome measurements included length of hospital stay, postoperative complications, postoperative gastrointestinal tract symptoms, and patient satisfaction. RESULTS: All patients had successful completion of paraesophageal hernia repair laparoscopically with no recurrences, and with an overall minor morbidity rate of 25%, major morbidity rate of 8%, and no deaths. Eight of 12 patients with concomitant reflux disease underwent successful laparoscopic Nissen fundoplication with complete control of reflux symptoms. The average hospital stay for patients with uncomplicated courses was 2.5 days. Long-term (> 6 weeks) postfundoplication symptoms occurred in 13% of those patients who underwent fundoplication. Eleven (92%) of 12 patients described good to excellent results with complete or near complete control of all preoperative symptoms. CONCLUSIONS: Laparoscopic repair of types II and III paraesophageal hernias can be performed under elective circumstances by experienced laparoscopic surgeons, with acceptable morbidity and comparable short-term efficacy. Addition of a concomitant antireflux procedure should be reserved for those patients with clear preoperative evidence of reflux disease secondary to a mechanically defective lower esophageal sphincter. Patients with a normal lower esophageal antireflux barrier do not need a concomitant antireflux procedure.

Adult↗

Preliminary results of a prospective randomized trial of laparoscopic onlay versus conventional inguinal herniorrhaphy.

BACKGROUND: To compare laparoscopic onlay hernia repair with conventional surgery, 61 patients were randomized to either open or laparoscopic surgery. METHODS: Traditional repairs were done according to the surgeons' preference. Laparoscopic repairs utilized a modified onlay technique with a meshed prototype prosthesis. RESULTS: Mean operative time was 62.5 minutes for the laparoscopic group and 80.9 minutes for the open group. Each group had five complications. There were two conversions from laparoscopic to open surgery. Individuals undergoing laparoscopic surgery reported a mean intake of 5 doses of an oral narcotic analgesic versus 16 doses in the open group. Return to normal activity (nonstrenuous) was 7.5 days in the laparoscopic group and 18.5 days in the open group. After a mean follow-up of 8 months (range 1 to 14), there have been two recurrences in the open group and one in the laparoscopic group. CONCLUSION: Laparoscopic onlay inguinal herniorrhaphy is a viable alternative for those who prefer a minimally invasive treatment for this disease.

Female↗

The role of coronary revascularization in recipients of an implantable cardioverter-defibrillator.

The impact of adjuvant coronary revascularization was studied in a group of 138 recipients of an implantable cardioverter-defibrillator, all of whom had ischemic heart disease as the cause of their arrhythmias. Patients chosen for revascularization had more severe anatomic, symptomatic, or physiologic evidence of active ischemia. There were no operative deaths among 23 patients who actually underwent coronary artery bypass combined with cardioverter-defibrillator implantation; however, operative mortality by the intention-to-treat principle was 8% (2/25). Total cardiac survival was better for patients who underwent revascularization than for those patients who had "high-risk" characteristics and did not undergo revascularization. Stratified subgroup analysis demonstrated significant survival advantages favoring revascularization in patients with three-vessel or left main coronary artery disease, class III or IV angina, and an ejection fraction greater than 25%. Multivariate analysis revealed that low ejection fraction and left main coronary artery disease were independent predictors of decreased survival.

Adult↗

Transvenous versus transthoracic cardioverter-defibrillator implantation. A comparative analysis of morbidity, mortality, and survival.

The hypothesis that transvenous implantation of a cardioverter-defibrillator is associated with less morbidity than use of a transthoracic approach was investigated in a retrospective series of 146 patients. None of these patients had concomitant heart procedures, and the preoperative characteristics of the two groups were similar. When analyzed by actual technique used (transvenous, 57 patients; transthoracic, 89 patients) and by the intention-to-treat method (transvenous, 65 patients, 8 of whom actually underwent thoracotomy; thoracotomy, 81 patients), transvenous implantation was associated with a lower incidence of postoperative respiratory complications and atrial fibrillation. Total cardiac mortality and freedom from sudden cardiac death in the transvenous and transthoracic groups were comparable at 2 years.

Aged↗