Search PubMed⌕ Search

Biomedical subjects

D S Holder

Publications and source records attributed to D S Holder.

At least 19 recordsLinked to original sources

Electrical impedance tomography spectroscopy (EITS) for human head imaging.

Electrical impedance tomography (EIT) is a recently developed medical imaging method which has practical advantages for imaging brain function as it is inexpensive, rapid and portable. Its principal use in validated human studies to date has been to image changes in impedance at a single excitation frequency over time, but there are potential applications where it is desirable to obtain images from a single point in time, which could be achieved by imaging over multiple frequencies. We describe a novel multifrequency EIT design which provides up to 64 electrodes for imaging in the head. This was achieved by adding a multiplexer to a single channel of an existing system, the Sheffield Mark 3.5. This provides a flexible protocol for addressing up to 64 electrodes but CMRR decreases from 90 dB to 80 dB and analogue amplifier bandwidth from > 1.6 MHz to 0.8 MHz. This did not significantly affect performance, as cylinders of banana, 10% of the diameter of a saline filled spherical tank, could be visualized with frequency referenced imaging. The design appears to have been an acceptable compromise between practicality and performance and will now be employed in clinical trials of multifrequency EIT in stroke, epilepsy and neonatal brain injury.

Electric Impedance↗

A comparison of headnet electrode arrays for electrical impedance tomography of the human head.

Three types of commercially available headnet electrode arrays, designed for use in EEG, and conventional EEG Ag/AgCl cup electrodes were tested on human subjects, and a realistic, saline-filled head-shaped tank was prepared with vegetable skin to simulate human skin in order to determine the optimum electrode system for electrical impedance tomography (EIT) of the human head. Impedance changes during EIT acquisition were produced in healthy volunteers during a finger-thumb apposition task and in tanks by the insertion of a Perspex rod. Signal-to-baseline noise, measured from raw EIT data, was 2.3 +/- 0.3 and 2.3 +/- 0.2 for the human and tank data, respectively. In both the human and tank experiments, a commercial hydrogel elasticated electrode headnet produced the least amount of baseline noise, and was the only headnet in the human data with noise levels acceptable for EIT imaging. Image quality measured in the tank was similar for most of the headnets tested, except that the EEG electrodes produced a higher positional error and electrodes in a geodesic elasticated net produced images with worse subjective image quality. Overall, the hydrogel elasticated headnet was judged to be the most suitable for human neuroimaging with EIT.

Adult↗

A multi-shell algorithm to reconstruct EIT images of brain function.

Electrical impedance tomography (EIT) may be used to image brain function, but an important consideration is the effect of the highly resistive skull and other extracerebral layers on the flow of injected current. We describe a new reconstruction algorithm, based on a forward solution which models the head as four concentric, spherical shells, with conductivities of the brain, cerebrospinal fluid, skull and scalp. The model predicted that the mean current travelling in the brain in the diametric plane for current injection from polar electrodes was 5.6 times less than if the head was modelled as a homogeneous sphere; this suggests that an algorithm based on this should be more accurate than one based on a homogeneous sphere model. In images reconstructed from computer-simulated data or data from a realistic saline-filled tank containing a real skull, a Perspex rod was localized to within 17% or 20% of the tank diameter of its true position, respectively. Contrary to expectation, the tank images were less accurate than those obtained with a reconstruction algorithm based on a homogeneous sphere. It is not yet clear if the theoretical advantages of this algorithm will yield practical advantages for head EIT imaging; it may be necessary to proceed to more complex algorithms based on numerical models which incorporate realistic head geometry. If so, this analytical forward model and algorithm may be used to validate numerical solutions.

Algorithms↗

Design and performance of the UCLH mark 1b 64 channel electrical impedance tomography (EIT) system, optimized for imaging brain function.

The UCLH Mark 1b is a portable EIT system that can address up to 64 electrodes, which has been designed for imaging brain function with scalp electrodes. It employs a single impedance-measuring circuit and multiplexer so that electrode combinations may be addressed flexibly using software. It operates in the relatively low frequency band between 225 Hz and 77 kHz, as lower frequencies produce larger changes during brain activity, and has a videocassette-sized headbox on a lead 10 m long, connected to a base box the size of a video recorder, and notebook PC, so that recordings may be made in ambulant subjects. Its performance was assessed using a resistor-capacitor network, and two saline-filled tanks-a cylindrical Perspex one and a latex one which contained a human skull. System signal-to-noise ratio was better than 50 dB and the maximum reciprocity error less than 10% for most frequencies. The CMMR was better than 80 dB at 38 kHz and a sponge, 20 mm across, which caused a local 12% impedance increase, was correctly localized in images. This suggests that the system has adequate performance to image impedance changes of 5-50% known to occur in the brain during normal activity, epilepsy or stroke; clinical trials to image these conditions are in progress.

Brain↗

A comparison of techniques to optimize measurement of voltage changes in electrical impedance tomography by minimizing phase shift errors.

In electrical impedance tomography, errors due to stray capacitance may be reduced by optimization of the reference phase of the demodulator. Two possible methods, maximization of the demodulator output and minimization of reciprocity error have been assessed, applied to each electrode combination individually, or to all combinations as a whole. Using an EIT system with a single impedance measuring circuit and multiplexer to address the 16 electrodes, the methods were tested on resistor-capacitor networks, saline-filled tanks and humans during variation of the saline concentration of a constant fluid volume in the stomach. Optimization of each channel individually gave less error, particularly on humans, and maximization of the output of the demodulator was more robust. This method is, therefore, recommended to optimize systems and reduce systematic errors with similar EIT systems.

Artifacts↗

Three-dimensional electrical impedance tomography of human brain activity.

Regional cerebral blood flow and blood volume changes that occur during human brain activity will change the local impedance of that cortical area, as blood has a lower impedance than that of brain. Theoretically, such impedance changes could be measured from scalp electrodes and reconstructed into images of the internal impedance of the head. Electrical Impedance Tomography (EIT) is a newly developed technique by which impedance measurements from the surface of an object are reconstructed into impedance images. It is fast, portable, inexpensive, and noninvasive, but has a relatively low spatial resolution. EIT images were recorded with scalp electrodes and an EIT system, specially optimized for recording brain function, in 39 adult human subjects during visual, somatosensory, or motor activity. Reproducible impedance changes of about 0.5% occurred in 51/52 recordings, which lasted from 6 s after the stimulus onset to 41 s after stimulus cessation. When these changes were reconstructed into impedance images, using a novel 3-D reconstruction algorithm, 19 data sets demonstrated significant impedance changes in the appropriate cortical region. This demonstrates, for the first time, that significant impedance changes, which could form the basis for a novel neuroimaging technology, may be recorded in human subjects with scalp electrodes. The final images contained spatial noise and strategies to reduce this in future work are presented.

Adolescent↗

Solving the forward problem in electrical impedance tomography for the human head using IDEAS (integrated design engineering analysis software), a finite element modelling tool.

If electrical impedance tomography is to be used as a clinical tool, the image reconstruction algorithms must yield accurate images of impedance changes. One of the keys to producing an accurate reconstructed image is the inclusion of prior information regarding the physical geometry of the object. To achieve this, many researchers have created tools for solving the forward problem by means of finite element methods (FEMs). These tools are limited, allowing only a set number of meshes to be produced from the geometric information of the object. There is a clear need for geometrical accurate FEM models to improve the quality of the reconstructed images. We present a commercial tool called IDEAS, which can be used to create FEM meshes for these models. The application of this tool is demonstrated by using segmented data from the human head to model impedance changes inside the head.

Algorithms↗

Electrical impedance tomography of human brain activity with a two-dimensional ring of scalp electrodes.

Previously, electrical impedance tomography (EIT) has been used to image impedance decreases in the exposed cortex of rabbits during brain activity. These are due to increased blood volume at the site of the stimulated cortex; as blood has a lower impedance than brain, the impedance decreases. During human brain activity similar blood flow changes have been detected using positron emission tomography (PET) and functional magnetic resonance imaging (fMRI). If blood volume also changes then the impedance of human cortex will change during brain activity; this could theoretically be imaged with EIT. EIT data were recorded from a ring of 16 scalp electrodes in 34 recordings in 19 adult volunteers before, during and after stimulation with (1) a visual stimulus produced by an 8 Hz oscillating checkerboard pattern or (2) sensory stimulation of the median nerve at the wrist by a 3 Hz electrical square wave stimulus. Reproducible impedance changes, with a similar timecourse to the stimulus, were seen in all experiments. Significant impedance changes were seen in 21 +/- 5% (n = 16, mean +/- SEM) and 19 +/- 3% (n = 18) of the electrode measurements for visual and somatosensory paradigms respectively. The reconstructed 2D EIT images showed reproducible impedance changes in the approximate region of the stimulated cortex in 7/16 visual and 5/18 somatosensory experiments. This demonstrates that reproducible impedance changes can be measured during human brain activity. The final images contained spatial noise; the reasons for this and strategies to reduce this in future are discussed.

Adult↗

Validation of a 3D reconstruction algorithm for EIT of human brain function in a realistic head-shaped tank.

Previous work has demonstrated that electrical impedance tomography can be used to image human brain activity during evoked responses, but two-thirds of the reconstructed images fail to localize an impedance change to the expected stimulated cortical area. The localization failure may be caused by modelling the head as a homogenous sphere in the reconstruction algorithm. This assumption may lead to errors when used to reconstruct data obtained from the human head. In this study a 3D reconstruction algorithm, based on a model of the head as a homogenous sphere, was characterized by simulating the algorithm model, the head shape and the presence of the skull in saline-filled tanks. EIT images of a sponge, 14 cm3 volume with a resistivity contrast of 12%, were acquired in three different positions in tanks filled with 0.2% saline. In a hemispherical tank, 19 cm in diameter, the sponge was localized to within 3.4-10.7% of the tank diameter. In a head-shaped tank, the errors were between 3.1 and 13.3% without a skull and between 10.3 and 18.7% when a real human skull was present. A significant increase in localization error therefore occurs if an algorithm based on a homogeneous sphere is used on data acquired from a head-shaped tank. The increased error is due to the presence of the skull, as no significant increase in error occurred if a head-shaped tank was used without the skull present, compared to the localization error within the hemispherical tank. The error due to the skull significantly shifted the impedance change within the skull towards the centre of the image. Although the increased localization error due to the skull is not sufficient to explain the localization errors of up to 50% of the image diameter present in the images of some human subjects, the future use of a realistic head model in the reconstruction algorithm is likely to reduce the localization error in the human images due to the presence of the skull.

Algorithms↗

Two-dimensional finite element modelling of the neonatal head.

Electrical impedance tomography (EIT) could allow the early diagnosis of infant brain injury following birth asphyxia. The purpose of this work was to determine the effect of variations in skull, scalp or cerebrospinal fluid (CSF) resistivity, as these vary in clinical conditions and could degrade image quality. These factors were investigated using finite element models of the adult and neonatal head. The results suggest that there is a wide range over which the resistivity of the neonatal skull has little effect on the sensitivity to a central impedance change. The scalp and CSF appear to shunt current away from the brain; when their resistivity was decreased from normal values, this shunting effect increased and caused a decrease in sensitivity to a central resistance change. The resistivity of neonatal skull has not, to our knowledge, been directly measured and will anyway vary within and between individuals; this work suggests that EIT will be relatively insensitive to variations in neonatal skull impedance.

Adult↗

Assessment and calibration of a low-frequency system for electrical impedance tomography (EIT), optimized for use in imaging brain function in ambulant human subjects.

An EIT system has been produced that has been optimized for imaging impedance changes with scalp electrodes during brain activity in ambulant subjects. It can record from 225 Hz to 65 kHz, has a small headbox on a lead 10 m long, and has software programmable electrode selection. In calibration experiments in a small cylindrical tank filled with potassium chloride solution and samples of cucumber, noise was less than 1% with averaging, and acceptable images were produced at frequencies down to 1800 Hz. This suggests that EIT can be performed at low frequencies, which are likely to give larger signals during brain activity. Future work will include trials in humans and improvement of the current source and isolation.

Brain Chemistry↗

Effect of skin impedance on image quality and variability in electrical impedance tomography: a model study.

A computer simulation is used to investigate the relationship between skin impedance and image artefacts in electrical impedance tomography. Sets of electrode impedance are generated with a pseudo-random distribution and used to introduce errors in boundary voltage measurements. To simplify the analysis, the non-idealities in the current injection circuit are replaced by a fixed common-mode error term. The boundary voltages are reconstructed into images and inspected. Where the simulated skin impedance remains constant between measurements, large impedances (> 2k omega) do not cause significant degradation of the image. Where the skin impedances 'drift' between measurements, a drift of 5% from a starting impedance of 100 omega is sufficient to cause significant image distortion. If the skin impedances vary randomly between measurements, they have to be less than 10 omega to allow satisfactory images. Skin impedances are typically 100-200 omega at 50 kHz on unprepared skin. These values are sufficient to cause image distortion if they drift over time. It is concluded that the patient's skin should be abraded to reduce impedance, and measurements should be avoided in the first 10 min after electrode placement.

Computer Simulation↗

Current approaches to analogue instrumentation design in electrical impedance tomography.

Electrical impedance tomography (EIT) is a novel medical imaging method, which allows reconstructed tomographic images of the internal impedance of a subject to be made with the use of a ring of electrodes. High precision impedance measurements are needed, because the image reconstruction process is ill-conditioned and small errors in measurement can lead to large errors in the final image. In practice, there are formidable instrumentation problems, due to the interaction of finite current drive output impedance, recording amplifier common mode rejection, and unequal skin-electrode impedances. A number of different EIT systems have been constructed or are under development. These employ differing strategies, such as additional electrodes, multiple electrode current injection, or recording at multiple frequencies, to improve image accuracy. This paper reviews the nature of the instrumentation problems and the designs employed by differing groups in attempting to overcome them.

Body Composition↗

Improvement of the positional accuracy of EIT images of the head using a Lagrange multiplier reconstruction algorithm with diametric excitation.

A novel algorithm for the reconstruction of dynamic images using diametric excitation has been developed. The algorithm is specifically designed to image impedance changes in the brain using boundary data obtained from scalp electrodes by incorporating a priori information. The a priori information is obtain by solving the forward problem using a finite-element model (FEM) which includes the discontinuity of the skull resistivity. The advantages with this new approach are that the sensitivity and accuracy of the location of the impedance changes are improved compared to methods based on adjacent excitation.

Algorithms↗

Some practical biological phantoms for calibrating multifrequency electrical impedance tomography.

Three groups of materials have been assessed with a Hewlett-Packard 4284A impedance analyser and Sheffield Mark 1 electrical impedance tomography (EIT) system for suitability for calibration of multifrequency EIT systems. They were required to be easy to use, stable over several hours, and have complex impedance similar to biological tissue. The groups were: (i) inorganic materials including barium titanate, polystyrene microspheres and fumed silica, all in aqueous suspension; these had phase angles below 1 degrees and so were unsuitable. (ii) Cucumber in KCl solution. Cucumber cortex had a phase angle of 40 degrees at a centre frequency of 50 kHz. Contrast between the cucumber and bathing solution could be selected by varying the KCl concentration. (iii) Polyurethane sponge immersed in packed red cells. The phase angle of packed cells was about 25 degrees at 1 MHz. Sponge resistivities and permittivities when immersed in packed cells were 5-20% higher than the bathing solution itself, for densities of 2-6.2% w/v. Both the biological materials appear suitable for the intended purpose; system (iii) is inherently more stable, and has capacitance in both bathing medium and test object. If an initial accuracy of greater than about +/- 15% is required, direct measurement with an impedance analyser is recommended prior to imaging studies.

Electric Impedance↗

Imaging of physiologically evoked responses by electrical impedance tomography with cortical electrodes in the anaesthetized rabbit.

The purpose of this study was to determine if electrical impedance tomography (EIT) could be used to image impedance changes of several per cent over tens of seconds, known to occur during evoked activity of the cerebral cortex. A ring of 16 electrodes was placed on the exposed superior surface of the brain of anaesthetized rabbits. EIT images were acquired every 15 s using a Sheffield Mark 1 EIT system. During periods of 2.5-3 min of intense photic stimulation of both eyes or electrical stimulation of a forepaw, reproducible impedance decreases of 4.5 +/- 2.7% and 2.7 +/- 2.4% (mean +/- SD) respectively occurred in appropriate cortical areas, with a time course similar to the period of stimulation. They were accompanied by adjacent smaller impedance increases. The decreases are probably due to increased blood flow and temperature; the cause of the adjacent increases may be a shadowing artefact of the reconstruction algorithm or due to physiological shrinkage of the extracellular space. This demonstrated, for the first time, that such small changes may be imaged under optimal conditions. These results are encouraging to the prospect that EIT may eventually be suitable for imaging evoked responses or epilepsy in human subjects.

Anesthesia↗

Design considerations and performance of a prototype system for imaging neuronal depolarization in the brain using 'direct current' electrical resistance tomography.

The ability to image the impedance changes that accompany neuronal depolarization in the brain would constitute a major advance in neuroscience technology. Unfortunately, these changes are likely to be small and rapid and so difficult to measure. The impedance change at frequencies above 10 kHz, as used by conventional EIT systems, may be estimated to be about 0.1%. Modelling indicates that a much larger impedance change of about 7% may occur with DC or very-low-frequency excitation. Difficulties with this approach include a low permissive current level and high electrode impedance. We constructed a prototype system employing square wave excitation at 5 Hz to evaluate such problems. It was tested in a saline-filled tank, recording 4000 frames s-1 at a current level of 50 microA. After averaging 100 sets of frames, the signal to noise ratio was 40-50 dB, and reciprocity errors were mostly 10-20%. Images of discrete resistivity changes of less than 10% could be obtained, but with significant systematic errors. While our prototype would not be suitable for neurophysiological imaging as it stands, it has enabled us to determine the modifications that would be required to construct a system for this application.

Action Potentials↗

Experimental validation of a novel reconstruction algorithm for electrical impedance tomography based on backprojection of Lagrange multipliers.

A novel approach to image reconstruction for electrical impedance tomography (EIT) has been developed. It is based on a constrained optimization technique for the reconstruction of difference resistivity images without finite-element modelling. It solves the inverse problem by optimizing a cost function under constraints, in the form of normalized boundary potentials. Its application to the neighboring data collection method is presented here. Mathematical models are developed according to specified criteria. These express the reconstructed image in terms of one-dimensional Lagrange multiplier functions. The reconstruction problem becomes one of estimating these functions from normalized boundary potentials. This model is based on a cost criterion of the minimization of the variance between the reconstructed and the true resistivity distributions. The algorithm was tested on data collected in a cylindrical saline-filled tank. A polyacrylamide rod was placed in various positions with or without a peripheral plaster of Paris ring in place. This was intended to resemble the conditions during EIT of epileptic seizures recorded with scalp or cortical electrodes in the human head. One advantage of this approach is that compensation for non-uniform initial conditions may be made, as this is a significant problem in imaging cerebral activity through the skull.

Algorithms↗