Search PubMed⌕ Search

Biomedical subjects

D S Drummond

Publications and source records attributed to D S Drummond.

At least 19 recordsLinked to original sources

A technique of occipitocervical arthrodesis in children using autologous rib grafts.

STUDY DESIGN: Description of an operative technique with an illustrative case report. OBJECTIVES: The technique is presented to provide an alternative to iliac crest graft procedures for achieving occipitocervical fusion in children. This technique is particularly useful in children with instability after extensive decompression or laminectomy and in children with a large protuberant occiput. SUMMARY OF BACKGROUND DATA: The majority of techniques previously described for occipitocervical fusion in children rely on corticocancellous iliac crest autograft. Results generally have been promising; however, it can be difficult to harvest enough graft to span large defects after extensive decompression or to contour an iliac crest graft to a protuberant occiput. Structural rib autograft is superior in terms of availability and its unique and modifiable contour. Theoretical benefits of rib graft include superior strength and lower donor site morbidity. METHODS: The surgical technique is described. A case of a 2-year-old boy with Down's syndrome and myelopathy secondary to cervical instability is reviewed. RESULTS: The patient underwent occipitocervical arthrodesis using the technique described. The child made a full neurologic recovery, and at the 2-years follow-up evaluation, the graft had incorporated and the spine was stable. CONCLUSION: A technique of occipitocervical arthrodesis in children is described using autologous rib graft. This procedure was designed to span large defects or to deal with a large protuberant occiput; however, it is also useful for less demanding cases and may offer several advantages compared with procedures relying on iliac crest graft.

Arthrodesis↗

Anterior vertebral screw strain with and without solid interspace support.

STUDY DESIGN: This in vitro biomechanical study examines segmental anterior vertebral screw strain and solid rod construct stiffness with and without the addition of multilevel, threaded cortical bone dowels in a bovine model. OBJECTIVE: To determine whether strain at the bone-screw interface is higher at the end levels during physiologic range loading, and whether solid interspace support decreases segmental strain on the implant. SUMMARY OF BACKGROUND DATA: Anterior instrumentation provides greater correction and preserves distal motion segments. However, nonunion and implant failure are observed more frequently than with posterior segmental instrumentation, and when observed, loss of fixation occurs at the end levels. METHODS: Eight calf spines underwent mechanical testing in the following sequence: 1) intact condition, 2) anterior release with anterior solid rod and bicortical rib grafts, and 3) anterior release with anterior solid rod and threaded cortical bone dowels (L2-L5). Instrumented vertebral screws were used to assess strain within the vertebral body by the near cortex, whereas an anterior extensometer spanning the instrumented segments was used to measure segmental displacements to calculate construct stiffness. The protocol included axial compression (-400 N), right lateral bending (4 Nm (Newton-meter), away from the implant), and left lateral bending (4 Nm, toward the implant). Statistical analysis included a one-way analysis of variance and a Student-Newman-Keuls post hoc test. A pilot study was performed using four additional specimens loaded for 4000 cycles to investigate macroscopic loosening after fatigue loading. RESULTS: In lateral bending toward the implant, the strain was higher at both end levels, with no differences between the rib and dowel reconstructions. The stiffness values were greater than the intact values for both groups. In lateral bending away from the implant, the strain also was higher at both end screws, and the dowel group had less strain at these levels than the rib group. Both groups were stiffer than the intact condition, and the dowel group was stiffer than the rib group. Axial compressive strain also was higher at the end levels, but this difference did not reach statistical significance. The rib group did not reach intact stiffness values, whereas the dowel group was stiffer than the intact condition. The fatigue study showed gross loosening at one or both end levels in all cases. CONCLUSIONS: Higher strain was observed at the bone-screw interface in both end screws of an anterior solid rod construct during lateral bending, which correlates with the clinically observed failure location. This suggests that physiologic range loading may predispose to failure at the end levels. Disc space augmentation with solid implants increased construct stiffness in all three load paths and decreased strain at the end levels in lateral bending away from the implant. Future implant modifications should achieve better fixation at the end screws, and the current model provides a means to compare different strategies to decrease strain at these levels.

Animals↗

Prevention of positional brachial plexopathy during surgical correction of scoliosis.

Continuous intraoperative monitoring of spinal cord function using somatosensory evoked potentials (SSEP) has gained nearly universal acceptance as a reliable and sensitive method for detecting and possibly preventing neurologic injury during surgical correction of spinal deformities. In several reports, spinal cord injury was identified successfully based on changes in SSEP response characteristics, specifically amplitude and latency. Less well documented and used, however, is monitoring of peripheral nerve function with SSEPs to identify and prevent the neurologic sequelae of prolonged prone positioning on a spinal frame. The authors describe a patient who underwent surgical removal of spinal instrumentation but was not monitored. A brachial plexopathy developed in this patient from pressure on the axilla exerted by a Relton-Hall positioning frame during spinal surgery. In addition, data are presented from 15 of 500 consecutive pediatric patients who underwent surgical correction of scoliosis between 1993 and 1997 with whom intermittent monitoring of ulnar nerve SSEPs was used successfully to identify impending brachial plexopathy, a complication of prone positioning. A statistically significant reduction in ulnar nerve SSEP amplitude was observed in 18 limbs of the 500 patients (3.6%) reviewed. Repositioning the arm(s) or shoulders resulted in nearly immediate improvement of SSEP amplitude, and all awoke without signs of brachial plexopathy. This complication can be avoided by monitoring SSEPs to ulnar nerve stimulation for patients placed in the prone position during spinal surgery.

Adult↗

Congenital vertebral anomalies in ischiopagus and pyopagus conjoined twins.

A review of clinical records and radiographs revealed that five of 10 patients with conjoined twinning (three of six ischiopagus and two of two pyopagus twins) had congenital vertebral anomalies including hemivertebrae (3), multiple thoracic anomalies (1), right hemisacral agenesis (1), and three lumbar vertebra (1). No mirror image anomalies were identified, and different regions of the spine were involved in the two cases in which both twins had anomalies. Coexisting visceral and musculoskeletal anomalies included dextrocardia (3), atrial septal defect (1), congenital vertical talus (2), Sprengel's deformity (1), and multiple unilateral foot anomalies (1). Hip subluxation or dislocation was seen in five of eight ischiopagus or pyopagus twins after separation and required femoral and pelvic osteotomies. Lumbar scoliosis not associated with congenital vertebral anomalies was seen in two ischiopagus twins. These observations suggest an association between ischiopagus and pyopagus conjoined twins and congenital vertebral anomalies, and their coexistence is explained best by a nonspecific teratogenic insult during early embryogenesis.

Humans↗

Growth disturbances after distal tibial physeal fractures.

Twenty-four patients with distal tibial growth disturbance were reviewed. Disturbances were classified as physeal bar (prior to deformity), angular, linear or combined deformities. Treatment consisted of osteotomy in fourteen, epiphyseodesis in seven, excision of bony bar in two, and observation in one patient. Follow up was an average 36.6 months (range 4-129 months) after treatment of growth disturbance. The age at time of injury was 10.4 years of age average (range 3-15 years). There were 12 SH2, 2 SH3, 7 SH4, and 3 SH5 distal tibial physeal fractures. Thirteen of 15 fractures considered high energy and only 1 of 9 fractures considered low energy resulted in angular deformity. Angular and linear deformities presented an average 46 months (range 12-120 months) and physeal bars at an average 14 months (range 6-25 months) after injury. Patients with a delay in presentation of growth disturbance greater than 24 months had angular deformities in 92% compared with 33% in children presenting less than or at 24 months. Treatment based on type of deformity, age at time of injury, and growth remaining was considered successful in 83%. Patients with angular or linear deformities were more likely to present late, have high energy injuries, be male patients and have Salter-Harris types IV and V. Early diagnosis and treatment of growth disturbance can prevent severe deformity.

Adolescent↗

Augmentation of an anterior solid rod construct with threaded cortical bone dowels. A biomechanical study.

STUDY DESIGN: This static, nondestructive, in vitro biomechanical study examines anterior solid rod construct stiffness following the addition of multilevel, threaded cortical bone dowels in a bovine model. A comparison is made with a clinically relevant posterior construct with and without an anterior release. OBJECTIVES: To determine if the addition of solid, multilevel disc space implants will increase construct rigidity, while maintaining or enhancing anterior column length. SUMMARY OF BACKGROUND DATA: Anterior instrumentation for thoracolumbar and lumbar scoliosis has achieved greater correction and preserved distal motion segments; however, kyphosis over the instrumented segments and nonunion have been observed more frequently than with posterior segmental spinal instrumentation. METHOD: Fifteen calf spines underwent mechanical testing. Group A (n = 7) included anterior constructs: 1) intact, 2) anterior release/rod/rib graft (L2-L5), and 3) anterior release/rod/dowels (L2-L5). Group B (n = 8) included posterior constructs: 1) intact, 2) posterior rod without anterior release (T13-L5), 3) posterior rod (T13-L5)/anterior release/rib graft (L2-L5). The protocol included axial compression (-600 N), axial rotation (+7 Nm), flexion/extension (+7.5 Nm), and lateral bending (+7.5 Nm). An anterior extensometer measured segmental displacements to calculate construct stiffness. Lateral radiographs evaluated alignment for the anterior constructs. Statistical analysis involved a one way analysis of variance (ANOVA) and a Student-Newman-Keuls post hoc test. RESULTS: All reconstructions restored stiffness to intact values with the exception of the dowels alone in axial rotation. The rod/dowel construct was stiffer than all other groups in axial compression, flexion/extension, and lateral bending, with the exception of the posterior rod without discectomy, which was superior in flexion and statistically similar in extension, lateral bending, and axial rotation. The anterior construct with rib graft was equivalent to the posterior construct with rib graft in all modes of testing. The dowels created greater lordosis than the bicortical rib grafts. CONCLUSIONS: Disc space augmentation increased stiffness except in axial rotation, in which values were restored to the intact level. Stiffness was superior to a clinically relevant posterior instrumentation comparison group following anterior release, and was equivalent to a posterior construct without anterior release except in anterior flexion. In addition, the implants enhanced lordosis. Increased rigidity should improve rates of arthrodesis, while maintenance of sagittal alignment may prevent pathologic compensatory curves in adjacent spinal segments. Further research is required to determine the optimal method of achieving structural interspace support.

Animals↗

Recurrent meningitis in the pediatric patient--the otolaryngologist's role.

OBJECTIVE: To assess the etiology of recurrent meningitis in the pediatric patient. DESIGN: Retrospective case series and literature review. SETTING: Tertiary-care pediatric hospital. PATIENTS: Children (< 17-years-old) with recurrent meningitis, treated at Texas Children's Hospital (TCH) between 1984 and 1995. RESULTS: A review of 463 cases of bacterial meningitis over an 11 year period revealed six children aged 3 months to 15 years with the diagnosis of recurrent meningitis. The patient's age, number of episodes of meningitis, diagnostic investigations performed and etiologies of recurrent meningitis were recorded. Fifteen episodes of meningitis were identified in these six patients; Streptococcus pneumoniae represented the bacteriology in 73% of the cases. Two patients were diagnosed with temporal bone abnormalities, two children with immunological deficiencies and no underlying etiology for the recurrent meningitis was identified in the remaining two patients. In this series, one-third of patients had an otolaryngologic etiology for their recurrent meningitis. These six patients, along with a review of the recent literature, will highlight the need for otolaryngological assessment and the importance of considering immunological investigations when managing recurrent meningitis in the pediatric patient. CONCLUSION: We propose that children with recurrent meningitis of unknown etiology undergo: (1) an audiological evaluation; (2) a CT scan of the temporal bones, skull base and paranasal sinuses; and (3) an immunological evaluation.

Audiometry↗

Pediatric fracture without radiographic abnormality. Description and significance.

With an expanding application of magnetic resonance imaging in acute musculoskeletal injury, an increasing number of occult traumatic lesions of bone are being identified. The authors describe the entity of fracture without radiographic abnormality, which as the name suggests is a bony injury not apparent on plain radiographs. The clinical significance and potential sequelae have not been defined in the pediatric patient. Accordingly, the purpose of this study is to describe and classify the entity of the pediatric fracture without radiographic abnormality and delineate its importance and appropriate management. Twenty-five children were seen primarily or referred to The Children's Hospital of Philadelphia after having sustained an acute traumatic injury; all refused to bear weight or use their extremity, and all had initial plain radiographs that were interpreted as normal. Subsequent magnetic resonance images of all 25 children showed an occult fracture. These included Salter-Harris fracture Types II (two patients), III (one patient), and IV (three patients), intraosseous epiphyseal fractures (18 patients), and a metaphyseal diaphyseal fracture (one patient). Four patients with intraosseous epiphyseal fractures ultimately sloughed a portion of their articular cartilage, as observed at arthroscopy. The decision to proceed with magnetic resonance imaging in the evaluation of a child who refuses to use an extremity depends on many variables. However, magnetic resonance imaging has proven useful in revealing fractures without radiographic abnormality and in ruling out other pathosis.

Adolescent↗

Screw fixation of Grade III slipped capital femoral epiphysis.

From 1987 to 1992, 161 children were treated at The Children's Hospital of Philadelphia for slipped capital femoral epiphysis. Of these, 23 patients (23 hips) had Grade III slips (> 50%). Fixation was achieved by 1 or 2 screws in all patients. Twenty-one of 23 patients were available for followup (average followup, 2.8 years). Four slips were acute, 11 were acute-on-chronic, and 6 were chronic. At the most recent followup, radiographs were taken and a Harris Hip Score was assigned for each patient. Stabilization without progression of slip at followup was achieved in all patients. Screw placement was satisfactory per the criteria of Stambough in all patients. Four children (19%) had major complications: Three (1 acute slip and 2 acute-on-chronic slips) had avascular necrosis of the femoral head; One (chronic slip) had chondrolysis. There were no immediate postoperative complications. The mean Harris Hip Score for these 4 patients was 85 points, versus a mean score of 94 points for all 21 patients. Chronic Grade III slipped capital femoral epiphysis can be treated safely and effectively by screw fixation. Five of 6 patients had satisfactory results; the only exception had evidence of chondrolysis preoperatively. Acute and acute-on-chronic Grade III slipped capital femoral epiphyses treated with screw fixation are less predictable. In 15 patients, reduction occurred in 9 hips despite deliberate avoidance of forceful manipulative maneuvers. Avascular necrosis developed in 3 (33%) of these 9 hips. Reduction of the acute component of the slip during screw fixation, whether deliberate or not, indicates gross instability. It is hypothesized that avascular necrosis may be associated with injury to the epiphyseal vasculature occurring at the time of the acute slip.

Adolescent↗

Efficacy of spinal cord monitoring in scoliosis surgery in patients with cerebral palsy.

Although spinal cord monitoring is recommended during scoliosis surgery, a review from Rancho Los Amigos Medical Center stated that they were only able to obtain reproducible tracings in 53% of cerebral palsy patients. To ascertain that monitoring is both feasible and reliable in these patients, we reviewed the records of 34 consecutive patients with cerebral palsy who had scoliosis surgery at our institution. Spinal cord function was monitored by recording peripheral nerve, cervical/brainstem, and cortical somatosensory evoked potentials to posterior tibial nerve stimulation. Reproducible tracings were achieved in 31 of the 34 patients. Significant intraoperative changes were recorded in 12 of the 31 monitored patients, usually related to and requiring some modifications of the instrumentation. We conclude that with careful technique, spinal cord monitoring using cervical/brainstem somatosensory evoked potentials can be reliably achieved in most patients with cerebral palsy undergoing scoliosis surgery.

Adolescent↗

Influence of rigid spinal instrumentation on the neurogenic motor evoked potential.

Three case reports are presented to illustrate how placement of spinal instrumentation obliterates previously normal neurogenic motor evoked potentials (NMEPs) elicited by transosseous electrical stimulation. This results in an unacceptably high false-positive rate for NMEP recordings during scoliosis surgery. The loss of the NMEPs was attributed to shunting of electrical current from JO5 spinous process stimulating needles through the metal rod to ground, thus preventing adequate stimulation to the spinal cord. A modification of the transosseous technique with epidural stimulation to improve test reliability is described.

Adolescent↗

Distraction osteogenesis for congenitally short lesser metatarsals.

Six lesser metatarsal lengthening procedures were performed in three patients using a miniature external fixator to perform distraction osteogenesis. The metatarsals were lengthened an average of 15.5 mm. The external fixator was left in place for an average of 15.5 weeks, with additional time in a cast or cast shoe. Complications included five occurrences of infection, two cases of premature healing of the osteotomy, one nondisplaced fracture through the new bone formation, and hypertrophic granulation at a pin site. While all metarasals were successfully lengthened, two rays (one patient) had symptomatic stiffness at the metatarsophalangeal joint with continued metatarsalgia.

Adolescent↗

Occipitocervical arthrodesis in children. A new technique and analysis of results.

A new wiring technique for occipitocervical arthrodesis was used in sixteen consecutive children between 1985 and 1992. The twelve boys and four girls had an average age of nine years and six months (range, two years and five months to nineteen years and three months) at the operation. The arthrodesis was performed between the occiput and the second cervical vertebra in ten patients and between the occiput and the third cervical vertebra in six. The instability was related to congenital anomalies (six patients), decompression for cervical stenosis (four patients), Down syndrome (three patients), trauma (one patient), resection of a tumor (one patient), and neurofibromatosis (one patient). Six patients needed a laminectomy for decompression because of cervical stenosis or for removal of a tumor. All of the patients were managed with an autogenous bone graft from the iliac crest and postoperative immobilization with a halo device. Fusion was achieved in fifteen of the sixteen patients. Complications developed in seven patients. The use of wire fixation, combined with the inherent stability of the bone-graft construct, allowed for removal of the halo device relatively early (range, six to twelve weeks), before the fusion was fully mature. No graft was displaced. All of the patients were followed at least until there was radiographic evidence of fusion (fifteen patients) or until a reoperation was performed (one patient). The average duration of follow-up was thirty-seven months (range, twelve to 108 months).

Bone Nails↗

Complications in children managed with immobilization in a halo vest.

Thirty-seven patients who were three to sixteen years old were managed with immobilization in a halo vest between 1987 and 1993. Twenty-four patients (65 per cent) had the halo vest applied in conjunction with operative arthrodesis of the cervical spine; the remaining thirteen patients (35 per cent) had the halo vest applied to immobilize the cervical spine after trauma. Complications occurred in twenty-five patients (68 per cent). Pin-site infections were the most common complications, developing in twenty-two patients. Grade-II infections (purulent drainage) developed more frequently in children who were eleven years old or more: they were identified in five of fourteen such patients, compared with two of twenty-three patients who were ten years old or less. There was a tendency toward more grade-I infections (non-purulent drainage, with or without erythema) and loosening of the pins in the children who were ten years old or less: eleven of twenty-three such patients had each of those complications, compared with four of fourteen children who were eleven years old or more. Both loosening and infection occurred more frequently at the anterior pin sites. Other complications included one dural penetration, one transient injury of the supraorbital nerve, and three pin-site scars that were considered by the family to be objectionable. There were no complications related to the vest part of the halo vest. Younger patients who had a halo construct with more than four pins (multiple-pin constructs) had a similar rate of complications compared with patients who were managed with a standard four-pin halo construct.(ABSTRACT TRUNCATED AT 250 WORDS)

Adolescent↗

The use of MRI-compatible titanium segmental spinal instrumentation in pediatric patients with intraspinal tumor.

Severe kyphosis is a frequent complication of multiple laminectomies for the treatment of intraspinal tumors in growing children. Early Segmental Spinal Instrumentation (SSI) and posterior spinal fusion can prevent this complication, but because of ferromagnetic properties of conventional stainless steel implants, magnetic resonance imaging (MRI) performed to determine completeness of the resection and later for recurrence of the tumor becomes difficult. To overcome the problems with postoperative imaging, we have resorted to early stabilization of the spine following laminectomy with titanium alloy implants. The decreased ferromagnetic properties of titanium alloy result in less scatter distortion of the image, thus permitting a better follow-up of the tumor. This paper reports five consecutive patients with stabilization of the spine with titanium alloy implants and posterior spinal fusion done at the time of laminectomy. The use of titanium alloy implants in these patients allowed detailed MRI follow-up in all cases, and in two patients offered the surgical team information that altered or affected the patient's care.

Adolescent↗

Intraoperative anaphylaxis due to exposure to latex (natural rubber) in children.

Intraoperative anaphylaxis secondary to exposure to latex is a serious and potentially life-threatening phenomenon that has been recognized more frequently in recent years. Between 1989 and 1992, twenty-one patients had a Type-I (anaphylactic) reaction to latex intraoperatively at The Children's Hospital of Philadelphia. Twelve (57 per cent) of these patients had spina bifida. Six patients (29 per cent) had cerebral palsy, and five of them had a ventriculoperitoneal shunt. Of the remaining three patients, one (5 per cent) had exstrophy of the bladder, one had VATER syndrome, and one had Duchenne muscular dystrophy. All of the patients had had at least two previous operative procedures. Overall, sixteen patients (76 per cent) had a ventriculoperitoneal shunt. The manifestations of the allergic reaction included a rash in fifteen patients (71 per cent), hypotension in fifteen, tachycardia in eleven (52 per cent), bronchospasm in ten (48 per cent), bradycardia in two (10 per ent), and cardiac arrest in two. The symptoms occurred within minutes after the induction of the anesthesia in all but one patient, in whom hypotension and cardiovascular arrest developed approximately one hour after the beginning of the operation. Two patients had a full cardiopulmonary arrest while under the anesthesia. All twenty-one patients responded to management; there were no deaths. Of the six patients who had cerebral palsy, five had been managed with a ventriculoperitoneal shunt because of hydrocephalus following a previous intraventricular hemorrhage that was related to prematurity.(ABSTRACT TRUNCATED AT 250 WORDS)

Adolescent↗