Search PubMed⌕ Search

Biomedical subjects

D Rottenberg

Publications and source records attributed to D Rottenberg.

15 recordsLinked to original sources

The quantitative evaluation of functional neuroimaging experiments: mutual information learning curves.

Learning curves are presented as an unbiased means for evaluating the performance of models for neuroimaging data analysis. The learning curve measures the predictive performance in terms of the generalization or prediction error as a function of the number of independent examples (e.g., subjects) used to determine the parameters in the model. Cross-validation resampling is used to obtain unbiased estimates of a generic multivariate Gaussian classifier, for training set sizes from 2 to 16 subjects. We apply the framework to four different activation experiments, in this case [(15)O]water data sets, although the framework is equally valid for multisubject fMRI studies. We demonstrate how the prediction error can be expressed as the mutual information between the scan and the scan label, measured in units of bits. The mutual information learning curve can be used to evaluate the impact of different methodological choices, e.g., classification label schemes, preprocessing choices. Another application for the learning curve is to examine the model performance using bias/variance considerations enabling the researcher to determine if the model performance is limited by statistical bias or variance. We furthermore present the sensitivity map as a general method for extracting activation maps from statistical models within the probabilistic framework and illustrate relationships between mutual information and pattern reproducibility as derived in the NPAIRS framework described in a companion paper.

Adult↗

A novel miniature ventricular assist device for hemodynamic support.

The HemoDynamics Systems enabler is a new cardiac assist pump that can expel blood from the left ventricle and provide pulsatile flow in the aorta. We evaluated the efficacy of the 18 Fr enabler. The enabler was inserted from the left ventricular apex into the ascending aorta in eight sheep. Heart failure (mild, moderate, and severe) was induced by microsphere injection into the coronary arteries to reduce cardiac output by 10-30%, 31-50%, and more than 50% from baseline, respectively. The enabler was activated, and its flow was increased to approximately 2.0 L/min. Hemodynamic variables were recorded before and after activation. In moderate heart failure, cardiac output and mean aortic pressure increased from 2.3 +/- 0.6 L/min and 59 +/- 12 mm Hg before assist to 2.8 +/- 0.6 L/min and 70 +/- 8 mm Hg at 30 minutes after activation, respectively (p < 0.01). Left atrial pressure decreased from 17 +/- 3 to 13 +/- 4 mm Hg (p < 0.05). Similar findings were observed in mild and severe heart failure. Despite its small diameter, the enabler significantly improved the hemodynamics of failing hearts and may potentially serve as a means of peripheral left ventricular support. Further study is warranted.

Animals↗