Search PubMed⌕ Search

Biomedical subjects

D Roser

Publications and source records attributed to D Roser.

11 recordsLinked to original sources

Results of a modified left atrial maze procedure as a combined procedure.

Starting in November 1999, we performed a left atrial radiofrequency ablation procedure concomitantly to a variety of cardiac surgical procedures. By January 2001, this ablation procedure had been performed on 100 patients (age 65.7 +/- 10.4 years, 53 % male, 47 % female, left atrium 51.0 +/- 7.5 mm) suffering either from chronic or paroxysmal atrial fibrillation. Primary cardiac pathology was mitral valve disease in most cases (43), aortic valve disease (28) or coronary heart disease (27). After bilateral pulmonary veins isolation, an additional ablation line was directed from the left pulmonary veins to the mitral valve annulus (Thermaline probe, Boston Scientific Corporation, USA). Finally, the left atrial appendage was resected. Surgical success was evaluated in the immediate postoperative course, 3 and 6 months postoperatively (ECG and echocardiography), and every year after that. Operative time was 229.7 +/- 56.5 min, ablation time 18.8 +/- 6.9 min. Follow-up is 95 % complete at the time of writing. Mean follow-up time was 7.3 months, ranging from 3 to 23 months. Success (sinus rhythm and atrial contraction) was proven in 72 out of 90 patients (80.0 %) (75.0 % mitral valve surgery, 84.0 % other cardiac surgery). The reported results support a broad spectrum of indications for this left atrial ablation procedure.

Aged↗

Buffer distances for on-site sewage systems in Sydney's drinking water catchments.

Pathogens and nutrients released from on-site sewage systems represent a risk to surface and ground water quality, particularly where there are sensitive receiving waters such as in drinking water catchments. Buffer zones between on-site systems and waterways are one barrier used to protect water quality. The increased time and distance they provide increases the opportunities for the effluent purification functions of the soil to occur. A risk management model is proposed to assess the efficacy of the buffer zones in Sydney's drinking water catchments. The model is the basis for the development of performance based setback distances for on-site systems from waterways, and incorporates stochastic analysis of pathogen and nutrient transport in the environment and consideration of the effluent quality variability from on-site systems. Catchment-scale integration of contaminant transport is employed to facilitate a risk assessment of on-site systems. The risk management model also allows for the impact of on-site system management and maintenance on catchment water quality to be assessed through scenario building and feedback mechanisms.

Models, Theoretical↗

Centralised versus decentralised sewage systems: a comparison of pathogen and nutrient loads released into Sydney's drinking water catchments.

Data collected from centralised and decentralised sewage treatment plants throughout Sydney's drinking water catchments was used to calculate the relative catchment loads of Cryptosporidium, enteric viruses, nitrogen and phosphorus for an initial screening assessment. Loads were assessed at median and 90 percentile values for expected and worst-cases scenarios. The expected scenario in the Sydney drinking water catchments is that decentralised systems (servicing 32,800 people) provide similar total loads to centralised systems (serving 70% of the catchment population) for total phosphorus (37,090 kg x y(-1)), Cryptosporidium (10(11) oocysts x y(-1)) and enteric viruses (9.1 x 10(13) y(-1)), but higher loads of total nitrogen (237,610 vs. 136,740 kg x y(-1)). Decentralised systems, however, were predicted to have higher loads in the worst-case scenario with 620,620 kg x y(-1) TN, 82,040 kg x y(-1) TP, 7.3 x 10(13) Cryptosporidium oocysts x y(-1) and 9 x 10(15) enteric viruses per year. Greater load variability was experienced with decentralised systems, which presumably reflects less reliability in their current operation and maintenance. Overall, catchment water quality is therefore not only affected by sewage disposal methods, but also failure issues. Decentralised system disposal to land may afford a degree of mitigation that can be enhanced, if the degree of failure is reduced.

Animals↗

Technical evolution of the Ross operation: midterm results in 186 patients.

BACKGROUND: The Ross operation approaches the ideal aortic valve replacement. Between February 1995 and February 2000 we performed 186 procedures. This article reviews modifications introduced reflecting our experience. METHODS: In all patients the Ross operation was performed as root replacement. Echocardiographic follow-up was complete in 94% of patients. RESULTS: No operative death or early mortality occurred, nor did thromboembolic or hemorrhagic events. One patient died at 25 months from hemoptysis with pulmonary valve vegetations. Three patients required reoperation for autograft insufficiency. In 1 patient a tethered cusp was repairable and in 2 patients progressive autograft dilatation required autograft replacement. After routinely incorporating support into the aortic annulus and replacing all dilated ascending aorta, autograft dilatation did not recur. For the pulmonary homograft, one outflow patch was placed to relieve a symptomatic gradient. Nine patients with elevated gradients were under observation. Echocardiography revealed autograft median peak systolic gradients of 4.6+/-2.8 mm Hg, pulmonary homograft gradients of 14.8+/-9.6 mm Hg, and nil or insignificant regurgitation. CONCLUSIONS: The aortic annulus must be supported and the dilated ascending aorta replaced. Root replacement with a short autograft allows consistent results. Pulmonary homograft dysfunction is rare but unpredictable.

Adolescent↗

The Ross operation as a combined procedure and in complicated cases--is there an increased risk?

BACKGROUND: In this report we address the question whether the Ross operation can be recommended in combined and complicated cardiac procedures. METHODS: From February 1995 to July 2000, we performed 203 Ross operations, 129 with ideal clinical presentation (group 1: mean age 41 +/- 13 years, male 105). In 74 patients, the clinical presentation was complex (group 2: mean age 35 +/- 17 years, male 57), defined as previous aortic or cardiac operations in 32, active endocarditis in 8 or combined procedures in 40 patients. Follow-up is 95 % complete. RESULTS: Neither early mortality nor thromboembolic events were observed. Complications in group 1 vs. group 2 were prolonged ventilation in 1 vs. 1, pacemaker insertion in 1 vs. 2, minor myocardial infarction in none vs. 2 and postoperative bleeds in 2 vs. 3 patients. In group 1, one patient died of hemoptysis at 25 months, and in group 2 one sudden death occurred at 5 months. In the long term, two patients required reoperation for autograft failure in group 1, and one on group 2. Pulmonary stenosis required surgical treatment in one patient of group 2. Echocardiography revealed physiological gradients across the autograft with no significant regurgitation in either group. CONCLUSION: The Ross operation has excellent mid-term results and is a safe and attractive therapeutic approach, both in combined procedures and complex clinical presentations.

Adolescent↗

The ross operation in 225 patients: a five-year experience in aortic root replacement.

BACKGROUND AND AIM OF THE STUDY: The Ross operation, introduced more than 30 years ago, has recently undergone several modifications to improve both technical feasibility and results. At the authors' institution, the Ross operation, performed as root replacement in all cases, was commenced in February 1995. METHODS: A total of 225 patients (177 males, 48 females; mean age 39+/-15 years; range: 2 to 67 years) were operated on up to December 2000. Aortic regurgitation was present in 80 patients, stenosis in 69, and combined disease in 73; prostheses were replaced in three patients. Combined procedures were performed in 51 patients. Nine patients had active endocarditis. Follow up was 98% complete and totaled 471 patient-years. RESULTS: There was no early mortality, and no thromboembolic or hemorrhagic events. Complications included prolonged ventilation in two patients, perioperative myocardial infarction in three, pacemaker implants in three and perioperative bleeding in six. One patient died at 25 months from hemoptysis, and one at five months of unknown cause. In the long term, four patients required reoperation due to autograft regurgitation (one autograft repair, three autograft replacements). Routine aortic annulus support, a lowered threshold in replacing all dilated ascending aorta and keeping the autograft short to the level of the sinotubular junction seems to have prevented further autograft failure. Pulmonary homograft stenosis led to reoperation in one patient. Six patients with elevated gradients are currently under observation. Echocardiography revealed autograft median peak gradients of 5.1+/-2.8 mmHg, pulmonary homograft gradients of 14.2+/-11.5 mmHg, and no significant regurgitation, except in one additional patient with recently diagnosed aortic insufficiency (grade >2). CONCLUSION: Mid-term excellent hemodynamic results, low morbidity and reoperation requirement support the evolved root replacement technique and justify its further utilization.

Adolescent↗

The Ross operation: do native aortic, native pulmonary, and homograft pulmonary valve size and form differences influence results?

BACKGROUND: The pulmonary autograft approaches the ideal aortic valve substitute but numerous technical modifications are debated. The valves involved often differ in diameter and shape of the recipient annulus. We previously reported simplified surgical rules and early results of 52 patients and here we extend the report to 76 patients and analyze the mid-term results with respect to valve mismatch. METHODS: We studied the influence of geometric discrepancies. Valve regurgitation and gradient are compared for size discrepancies up to or more than 3 mm between recipient annulus and pulmonary autograft. The normal tricuspid recipient aortic annulus is compared with the flat circular redo-prosthetic or bicuspid annulus. Patients with plication of the aortic annulus and remodeling of the distal aorta are reviewed, and lastly donor homograft to pulmonary autograft discrepancies up to and more than 3 mm are compared. RESULTS: The results were comparable in all groups and no significant differences were observed. CONCLUSION: The pulmonary autograft operation may be simplified, with good results at the least in the first year despite operative tailoring due to valve discrepancies.

Adolescent↗

The influence of geometric mismatch between the native aortic, native pulmonary and homograft pulmonary valve on the results of the pulmonary autograft operation.

BACKGROUND: The pulmonary autograft operation has achieved broad acceptance and may be the ideal aortic valve substitute. Both the pulmonary autograft and the aortic homograft are more complicated procedures than prosthetic valve replacement. The trend to insert the pulmonary autograft as a root replacement rather than in the subcoronary position has achieved greater uniformity in the results, but there is still confusing diversity in opinions on technical details and anatomical dimensions. The importance of both size and shape mismatches between the three valves involved has received little attention. The valves often differ in diameter and in the shape of the recipient aortic annulus. This uncertainty and the diversity of opinions on essential technical details was disconcerting when we proceeded from aortic homograft-to-pulmonary autograft operations, this was compounded by only a single homograft being available for every operation as we have no homograft bank. METHODS: We compared the hemodynamic results regarding various geometric mismatches. All operative details were the same and patients were studied at regular intervals. Comparisons were made in patients with mismatch between recipient aortic annulus and pulmonary autograft. Patients with a normal tricuspid aortic annulus were compared to those with either a circular redo prosthetic valve annulus or a bicuspid recipient annulus. Thirdly we compared the patients with plication of the aortic annulus to those with remodeling of the distal aorta. Lastly we compared mismatch between donor homograft and pulmonary autograft. RESULTS: No influence of geometric mismatch between the three valves could be found on the results of the pulmonary autograft operation. CONCLUSIONS: Good results are obtainable without a painful learning curve if one keeps to certain surgical principles. It need not be a complicated operation and geometric mismatches between the three valves involved may be compensated for adequately.

Adolescent↗

Changes in haemodynamics and left ventricular function during intravenous nifedipine infusion with and without additional propranolol in patients with coronary artery disease. A randomized, placebo controlled trial.

The haemodynamic effects of a combined intravenous treatment of nifedipine and propranolol in ten patients with coronary artery disease compared to a single treatment with nifedipine or placebo were investigated. Nifedipine infusion resulted in a reduction of left ventricular (LV) afterload and LV volumes with an increase in heart rate and EF and no change of the double product, coronary sinus flow, LV diastolic parameters and dp/dtmax. Addition of propranolol lowers myocardial oxygen demand by reducing heart rate and dp/dtmax together with a sustained afterload reduction with no change in LV volumes and EF. The vasodilatatory action of nifedipine pretreatment balanced the negative effects of acute beta-receptor blockade on LV function and allows the reduction of myocardial oxygen demand without a deterioration of LV function.

Angiography↗

A note on 'plotless' methods for estimating bacterial cell densities.

' Plotless ' techniques for determining population densities have been developed for, and applied to, higher plant populations. They can often be carried out more rapidly than techniques involving total counts of individuals in plots, or quadrants, but such plotless techniques have not been generally applied to the estimation of densities of bacterial cells. Direct microscopical counting of cell numbers in a field of view, an example of a plot-related method, has been traditionally used for microbial cell counts. In this study 'plot' and ' plotless ' methods on a variety of bacterial samples are compared. Estimates of bacterial cell density were obtained by measuring the distance of cells from a fixed point in a field of view. The values, which were more rapidly obtained, were directly correlated with total cell counts. Although there was some apparent deviation from a perfect 1:1 relationship with total counts, as indicated by a correlation coefficient less than 1.0, there were no significant differences between the replicated counts of bacteria on samples of tissue from the surface of Hypholoma basidiocarps (P less than 0.05). This indicated that the methods of enumeration were comparable. The distance-related estimates could readily be obtained from fields of view with cell densities varying over several orders of magnitude. It was more rapidly applied, particularly at high density, and the method was applicable not only to random cell distributions but also to the non-random distributions encountered when microbial cells aggregated into microcolonies. The method appears to be particularly well-suited for automated, digitized, direct counting procedures, as well as to estimating bacterial numbers on membrane filters and natural substrates.

Bacteria↗

Background and early results of a modified left atrial radiofrequency procedure concomitant with cardiac surgery.

With the introduction of the maze operation Cox was able to show that the surgical treatment of atrial fibrillation (AF) is feasible. However, the maze operation remains surgically demanding and time-consuming as it requires multiple incisions in both atria. This has led to the development of various modifications. With new ablative technology and the acceptable results of an exclusively left atrial maze procedure in combination with mitral valve surgery, it has become possible to simplify the maze operation radically. Thirty-one patients ( mean age 62.3 years) with chronic or intermittent AF underwent a modified radiofrequency procedure in combination with some other cardiac surgical operation. Mitral valve disease coexisted in 17 patients, aortic valve disease in 9, coronary heart disease in 4 patients and 1 had an atrial septal defect (ASD). After left atriotomy and with the use of the Thermaline radiofrequency ablator probe, bilateral pulmonary vein isolation was carried out. An additional ablation line was directed from the left pulmonary veins to the posterior mitral valve annulus, and finally the left atrial appendage was resected. The complete procedure added an average of only 18.2 minutes to the operation. In the early postoperative course AF or atrial flutter recurred in 12 patients but at discharge only 8 patients (24%) still had an arrhythmia. We concentrated on the first 26 patients of our series who had received a follow-up examination 3 months postoperatively. At discharge 18 of the 26 patients were in sinus rhythm (69,2%), and at 3 months after surgery 23 of 26 patients were in sinus rhythm (88.5%), with recovery of atrial contraction confirmed echocardiographically. Only 4 patients still required medication for arrhythmias. The modified radiofrequency ablation procedure of the left atrium proved to be simple to perform, quick and reliable. It offers the possibility of a surgical cure for AF when performed together with another cardiac operation, and the early results indicate a high rate of success for this simple procedure.

Adult↗