Search PubMed⌕ Search

Biomedical subjects

D Ropers

Publications and source records attributed to D Ropers.

33 records · Page 2Linked to original sources

Noninvasive detection of coronary artery stenosis using contrast-enhanced three-dimensional breath-hold magnetic resonance coronary angiography.

OBJECTIVES: The purpose of this study was to evaluate a contrast-enhanced three-dimensional (3D) breath-hold magnetic resonance (MR) technique for detection of coronary artery stenoses. BACKGROUND: The accuracy of previously published MR coronary angiography protocols varies widely. Recently, coronary artery imaging using T1-shortening contrast agent has become possible, but so far there are no data concerning its clinical application. METHODS: Magnetic resonance coronary angiography was performed in 50 patients with suspected coronary artery disease. Magnetic resonance data acquisition using an ultrafast 3D gradient-echo sequence lasted over 32 heartbeats within one single breath-hold. Twenty milliliters of gadopentetate dimeglumine was injected at a flow rate of 1 ml/s for two successive studies covering the main coronary arteries in single-oblique planes. Stenosis assessment by MR was compared with significant (diameter stenosis > 50%) stenoses on X-ray angiography. Evaluation was limited to the proximal and mid-coronary artery segments. RESULTS: Two hundred sixty-eight of 350 artery segments (76.6%) could be evaluated. Left circumflex coronary artery was only evaluable in 50% of cases by MR. In the evaluable segments, 48 of 56 stenoses and 193 of 212 nonstenotic segments were correctly classified by MR. On a patient basis, MR correctly identified 34 of 36 patients with and 8 of 14 patients without significant coronary stenoses as demonstrated by X-ray angiography (sensitivity 94.4%, specificity 57.1%). CONCLUSIONS: Oblique projection contrast-enhanced MR coronary angiograms obtained within one single breath-hold permit identification of patients with coronary stenoses in the proximal and mid segments of the major coronary arteries with satisfactory accuracy.

Adult↗

Contrast enhanced electron beam computed tomography to analyse the coronary arteries in patients after acute myocardial infarction.

OBJECTIVE: To evaluate the accuracy of contrast enhanced electron beam computed tomography (EBCT) after acute myocardial infarction in determining patency of the infarct related artery and detecting high grade stenoses and occlusions in the coronary vessels. DESIGN: Case study using blinded comparison with invasive coronary angiography. PATIENTS: 36 patients (mean age 53 years) 4-70 days after acute myocardial infarction. INTERVENTIONS: The patients were studied by EBCT and invasive coronary angiography. For EBCT, 50 axial images of the heart (3 mm slice thickness) were acquired. They were triggered by the ECG during breath holding, after intravenous injection of contrast agent. The original images, surface reconstructions, and maximum intensity projections were evaluated for the presence of high grade stenoses and occlusions of the coronary arteries. MAIN OUTCOME MEASURES: EBCT results were compared with invasive coronary angiography. RESULTS: Of a total of 144 coronary arteries (left main, left anterior descending, left circumflex, and right coronary artery in 36 patients), 29 (20%) were unevaluable by EBCT. In the remaining arteries, 33 of 36 high grade lesions were correctly detected (92% sensitivity). Specificity was also 92% (73/79). Patency of the infarct related artery was correctly detected in 15 of 16 cases (94%). Five of the 14 occluded infarct related arteries (35%) were mistaken as stenotic but patent, and six could not be assessed. CONCLUSIONS: EBCT is very accurate in detecting significant coronary artery lesions in patients after acute myocardial infarction, but differentiation between occluded and patent infarct related arteries is currently unreliable.

Adult↗

In-plane coronary arterial motion velocity: measurement with electron-beam CT.

PURPOSE: To determine the speed of and changes in the speed of coronary arterial movement during the cardiac cycle with electron-beam computed tomography (CT). MATERIALS AND METHODS: With electron-beam CT, 20 consecutive cross-sectional images were acquired at the mid right coronary artery (with 50-msec acquisition time, 8-msec intersection delay, 7-mm section thickness, and intravenous administration of 40 mL of contrast agent) in 25 patients. On the basis of the displacement of the left anterior descending, left circumflex, and right coronary arterial cross sections from image to image, movement velocity in the transverse imaging plane was calculated and was correlated with the simultaneously recorded electrocardiogram. RESULTS: The velocity of in-plane coronary arterial motion varied considerably during the cardiac cycle. Peaks were caused by ventricular systole and diastole and by atrial contraction. The mean velocity was 46.6 mm/sec +/- 12. 5 (SD). The mean velocity of right coronary arterial movement (69.5 mm/sec +/- 22.5) was significantly faster than that of the left anterior descending (22.4 mm/sec +/- 4.1) or the left circumflex coronary artery (48.4 mm/sec +/- 15.0). The lowest mean velocity (27. 9 mm/sec) was at 48% of the cardiac cycle. CONCLUSION: The lowest velocity of coronary arterial movement, which displays considerable temporal variation, was at 48% of the cardiac cycle.

Aged↗

Coronary arteries: MR angiography with fast contrast-enhanced three-dimensional breath-hold imaging--initial experience.

Gadolinium-enhanced, three-dimensional, breath-hold magnetic resonance (MR) coronary angiography was performed in two healthy volunteers and 11 patients suspected or known to have coronary artery disease. MR angiograms were compared with those obtained with retrospective respiratory gating. Of 52 main coronary arteries, 47 could be visualized with the breath-hold technique and 49 with the gating technique. Signal-to-noise and contrast-to-noise ratios were significantly higher with the breath-hold technique. Overall image quality was slightly lower with breath-hold imaging. With either technique, three of five, significant coronary stenoses were correctly identified.

Contrast Media↗

Value of electron-beam computed tomography for the noninvasive detection of high-grade coronary-artery stenoses and occlusions.

BACKGROUND: Reliable noninvasive assessment of coronary-artery stenoses and occlusions would constitute an advantage in the care of patients with known or suspected coronary artery disease. We investigated the accuracy of contrast-enhanced electron-beam computed tomography (CT) for the detection of high-grade coronary-artery stenoses and occlusions. METHODS: Electron-beam CT was performed in 125 patients. After intravenous injection of a contrast agent, 40 cross-sectional images of the heart were acquired during inspiration, triggered by the electrocardiogram in diastole. Three-dimensional reconstructions of the heart and coronary arteries were rendered to facilitate evaluation of the images. The proximal and middle segments of the major coronary arteries were evaluated for the presence or absence of high-grade stenoses and occlusions. The results were compared with those of invasive coronary angiography in a blinded fashion. RESULTS: Because of technical problems that impaired the quality of the images, 124 (25 percent) of the 500 coronary arteries studied (left main, left anterior descending, left circumflex, and right coronary) in a total of 125 patients were excluded from evaluation. No vessels could be evaluated in 19 patients (15 percent), and another 28 patients (22 percent) had one, two, or three vessels that could not be evaluated. In the remaining coronary arteries with adequate image quality, electron-beam CT permitted visualization of 69 of 75 high-grade stenoses and occlusions (sensitivity, 92 percent), whereas in 282 of 301 arteries, the absence of high-grade stenoses and occlusions was correctly detected (specificity, 94 percent). CONCLUSIONS: When image quality is adequate, electron-beam CT may be useful to detect or rule out high-grade coronary-artery stenoses and occlusions.

Adult↗

[Evaluation of coronary artery stenosis with respiratory gated NMR angiography].

Respiratory gated MR coronary angiography is a new MR imaging technique which permits reconstruction of the coronary arteries from a three-dimensional data set obtained from contiguous parallel sections. In this study, respiratory gated MR angiography was applied to assess significant coronary artery stenoses (> or = 50%). MR imaging was performed in 68 patients (50 men, 18 women) who had been referred to cardiac catheterization because of suspected or known coronary artery disease. The evaluation of coronary artery stenoses was performed in a blinded manner in the proximal, middle, and distal vessel segments after multiplanar coronary reconstruction of the MR images. Of the 680 coronary segments, 275 (40%) were located outside the imaging volume and were, therefore, excluded from further analysis. The highest sensitivity for stenosis detection was found in the proximal left anterior descending (LAD) and right coronary artery (RCA) with 75% and 71%, respectively. The overall sensitivity, however, was low with 48%. The overall specificity was 92%. The positive and negative predictive values were 67% and 85%, respectively. This study shows that significant coronary artery stenoses, especially in the proximal LAD and RCA, can be correctly identified using respiratory gated MR angiography. However, further technical improvements are necessary before this method may become a reliable diagnostic tool in clinical practice.

Adult↗

Comparison of vessel diameters in electron beam tomography and quantitative coronary angiography.

Electron beam tomography (EBT) has been shown to permit non-invasive imaging of the coronary arteries after intravenous injection of contrast agent and 3-dimensional reconstruction. We compared the vessel diameters in EBT reconstructions to quantitative coronary angiography (QCA). 10 patients were investigated by EBT and QCA. 3-dimensional EBT reconstructions (shaded surface display) were performed after acquisition of 40 axial cross-sections of the heart with 3 mm slice thickness (1 mm overlap) which were obtained triggered to the ECG in breathhold following intravenous injection of 120-160 ml of contrast agent. A fixed lower reconstruction threshold of 80 HU was used to selectively visualize the contrast-enhanced coronary artery lumen. At 60 sites in the coronary artery system, the vessel diameters measured in the EBT reconstructions were compared to the diameters found in quantitative analysis of the patients' coronary angiograms. The correlation coefficient of the vessel diameters in EBT and QCA was 0.83. Mean vessel diameters were not significantly different in EBT and QCA (3.06 +/- 0.93 vs. 2.97 +/- 0.94 mm). However, very small vessel diameters tended to be underestimated in the EBT reconstructions, which was due to the partial volume effect. It only vessel diameters measured in the left main or left anterior descending coronary artery were compared to QCA, the correlation increased to 0.87, since these vessel segments are less prone to artifacts in the EBT investigation. Vessel diameters in EBT and QCA correlated reasonably well. Due to partial volume effects, the diameter of very small vessels and stenotic segments tends to be underestimated by EBT.

Adult↗

Curved multiplanar reconstructions for the evaluation of contrast-enhanced electron beam CT of the coronary arteries.

OBJECTIVE: We investigated the applicability of curved multiplanar reconstructions for the evaluation of contrast-enhanced electron beam CT scans of the coronary arteries. SUBJECTS AND METHODS: Thirty-two patients (43-72 years old; mean age, 58 years old) underwent electron beam CT. After injection of i.v. contrast medium, 40 axial cross sections of the heart were acquired, triggered to the ECG during breath-hold (3-mm slice thickness, 1-mm overlap). Curved multiplanar reconstructions were obtained separately for each coronary artery. The reconstructions were independently evaluated by two investigators for the presence of high-grade stenoses and occlusions. The results were then compared with coronary angiography results, of which the two investigators had been unaware. RESULTS: Because of degraded image quality, 15 (12%) of the 128 vessels (left main, left anterior descending, left circumflex, and right coronary arteries in 32 patients) were excluded from evaluation. In the remaining 113 vessels, 16 (89%) of 18 high-grade stenoses and occlusions were correctly detected (89% sensitivity). Absence of significant stenosis was correctly detected in 87 (92%) of 95 vessels (92% specificity). The negative and positive predictive values were 98% and 67%, respectively. CONCLUSION: Curved multiplanar reconstructions are useful in the evaluation of contrast-enhanced electron beam CT scans of coronary arteries.

Adult↗

Noninvasive, three-dimensional visualization of coronary artery bypass grafts by electron beam tomography.

Electron beam tomography (EBT, ultrafast computed tomography [CT], cine CT) combines unique temporal and high spatial resolution and is especially well suited for cardiac imaging. We established and evaluated a protocol for the noninvasive visualization and assessment of aortocoronary artery bypass grafts. Twenty-five patients with 56 bypass grafts were studied by EBT. Forty contiguous cross-sectional images were acquired triggered to the electrocardiogram during breathhold and intravenous injection of contrast agent. Three-dimensional reconstructions of the heart and bypass grafts were performed and compared with selective angiography of the bypass grafts. In 1 patient with 2 bypass grafts, a technically inadequate EBT examination was obtained. In the remaining patients (54 grafts), all 13 bypass occlusions were diagnosed with a sensitivity and specificity of 100%. Evaluation for hemodynamically relevant stenosis was possible in 84% of cases (36 of 43 patent grafts) and yielded a sensitivity of 100% (5 of 5 high-grade stenoses correctly detected) and specificity of 97% (1 false-positive diagnosis of high-grade graft stenosis). The main reasons for impaired ability to evaluate the scans were breathing artifacts and misplacement of the imaging volume, causing parts of the bypass grafts to be cut off. EBT permits noninvasive determination of bypass graft occlusion and relevant stenosis with high accuracy.

Coronary Artery Bypass↗

[Noninvasive coronary angiography with electron beam tomography: methods and clinical evaluation in post-PTCA follow-up].

Electron beam tomography (EBT) is a computed tomography technique with unique spatial and temporal resolution. The aim of the study was to establish and evaluate a protocol for the non-invasive visualization and detection of stenoses of the coronary arteries. Following phantom studies, 103 patients were investigated. Among these, 25 patients after coronary angioplasty (PTCA) were included in a prospective, blinded comparison to coronary angiography. After injection of contrast agent in a peripheral vein, 40 axial cross sections of the heart were acquired, triggered to the ECG (slice thickness 3 mm, 1 mm overlap, pixel size 0.29 x 0.29 mm). Three-dimensional reconstructions of the heart and coronary arteries were performed in the form of "shaded surface display," the results were compared to coronary angiography. In the reconstructions, the proximal and mid section of the LAD was visualized in 94% and 85%, image quality was reduced for the right coronary artery (89%/64%) and left circumflex (74%/54%), mainly due to movement artifacts. EBT displayed a sensitivity of 100% (9/9) for the detection of occlusions and high-grade restenoses in patients after PTCA, due to one false-positive result, specificity was 92% (12/13). Three PTCA patients could not be evaluated due to respiration artifacts. Contrast-enhanced electron beam tomography (EBT) permits the visualization of coronary arteries and the detection of stenoses and occlusions with high sensitivity and specificity.

Adult↗

Visualization of the coronary arteries in three-dimensional reconstructions using respiratory gated magnetic resonance imaging.

OBJECTIVE: To assess the applicability of respiratory-gated magnetic resonance coronary angiography, combined with three-dimensional image reconstruction, for visualizing the coronary arteries. METHODS: Twenty subjects (three healthy volunteers and 17 patients without stenoses detected by coronary angiography) were investigated. Magnetic resonance imaging was performed in a 1.5 T scanner using ECG-triggered gradient-echo sequences to acquire a volume data set consisting of 24-48 contiguous axial cross-sections of the heart (2 mm slice thickness, 1.17 mm x 1.17 mm in-plane resolution). Navigator-echo-based retrospective respiratory gating was used to minimize respiratory motion artifacts. Three-dimensional reconstructions of the heart were rendered using surface-display techniques. The length of the visualized coronary arteries was measured in curved multiplanar reconstructions. RESULTS: In the three-dimensional reconstructions, the left main artery (LMA) and left anterior descending artery (LADA) were visualized in 17 cases, the left circumflex artery (LCXA) in 15, and the right coronary artery (RCA) in 16 cases. Vessel continuity was uninterrupted in all 17 cases for the LMA, in 14 for the LADA, eight for the LCXA, and 13 for the RCA. The mean lengths of the visualized vessels were 14 +/- 7 mm for the LMA, 65 +/- 13 mm for the LADA, 45 +/- 16 mm for the LCXA, and 37 +/- 26 mm for the RCA. Reasons for impaired visibility of the LCXA and RCA were poor image quality due to there being a low contrast:noise ratio, motion artifacts, and incomplete coverage by the imaging volume. CONCLUSIONS: Navigator-echo-based magnetic resonance imaging is a promising technique for investigating the coronary arteries. Acquisition of a volume data set permits three-dimensional displays of the coronary vessels.

Case-Control Studies↗

A transgenic mouse model of sickle cell disorder.

A single base-pair mutation (beta s) in codon 6 of the human beta-globin gene, causing a single amino-acid substitution, is the cause of sickle cell anaemia. The mutant haemoglobin molecule, HbS, polymerizes when deoxygenated and causes deformation of the erythrocytes to a characteristic 'sickled' shape. Sickling of cells in small vessels causes painful crises and other life-threatening complications. Although the molecular basis for sickle cell anaemia has been known for 30 years, no definitive treatment is available. An animal model of sickle cell anaemia would not only allow a detailed analysis of the factors that initiate erythrocyte sickling in vivo and of the pathophysiology of the disease, but would also permit the development of novel approaches to the treatment of the disease. By using the dominant control region sequences from the human beta-globin locus, together with human alpha- and beta s-globin genes, we have obtained three transgenic mice with HbS levels ranging from 10 to 80% of total haemoglobin in their red cells. As observed in homozygous and heterozygous Hbs patients, the erythrocytes of this mouse sickle readily on deoxygenation. Irreversibly sickled cells, which are characteristic of sickle-cell patients homozygous for beta s, are also observed in the peripheral blood of the mouse with high levels of HbS.

Anemia, Sickle Cell↗

Overlapping cross-sections significantly improve the reproducibility of coronary calcium measurements by electron beam tomography: a phantom study.

PURPOSE: We conducted phantom studies to investigate whether overlapping cross-sections and volumetric scoring would significantly improve interscan reproducibility of electron beam tomography (EBT) for coronary artery calcium quantification. METHOD: Fifteen phantoms simulating various amounts of coronary calcification were scanned in five different positions with a slice thickness of 3.0 mm and a table feed of 3.0, 2.5, and 2.0 mm. For the conventional "Agatston score" and a "volume score" (total volume of calcified lesions), interscan variabilities were compared between the three image acquisition protocols. RESULTS: Agatston score variability was significantly lower for the 2.0 mm table feed than for the 3.0 or 2.5 mm table feed (3.0 mm: 22.9 +/- 10.3%; 2.5 mm: 13.6 +/- 8.2%; 2.0 mm: 8.9 +/- 5.5%). Volume score variability was significantly lower for 2.5 and 2.0 mm table feed than for 3.0 mm table feed (3.0 mm: 21.7 +/- 11.0%; 2.5 mm: 10.9 +/- 5.9%; 2.0 mm: 9.8 +/- 5.9%). CONCLUSION: Overlapping cross-sections, especially in combination with volumetric scoring, significantly improved interscan reproducibility of EBT calcium quantification in a phantom study.

Aged↗