Comment on "Evidence of many-particle interactions in two-dimensional charge-stabilized colloidal crystals".
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to D Reinke.
Explore the source record for details and available documents.
Several types of pedicular screw systems have been utilized to augment lumbar spine fusion. All systems are made of stainless steel, which interferes with imaging techniques, especially MRI and CT scans. In search of a solution for this problem, we decided to study the use of titanium systems in the lumbar spine. Because there were no titanium pedicle screw systems available on the market, we decided to use the titanium Alta system currently used for femur fractures. This report details our experience in using this device for lumbar spine fusion. From 1990 to 1992, 25 patients underwent thoracic and lumbar fusion with Alta titanium screws and plates. Spinal fusion was performed for a variety of conditions, including metastatic tumor, fracture, spondylolisthesis, pseudoarthrosis, and postdecompressive instability. All but two patients obtained solid fusion clinically and radiographically and considerable improvement in back pain. There was loosening of the implant in both patients. Both patients had osteoporosis. One of these two patients developed pseudoarthrosis, which required further surgery. The other patient with a metastatic tumor of the spine remained asymptomatic without change in the spine alignment despite progression of the tumor. There were no broken screws encountered during follow-up. Two patients sustained subsequent fracture of the vertebra above the fusion. One of the patients also developed a fracture below the fusion. Fusion with titanium implants allowed postoperative evaluation and subsequent periodic examination of the spinal canal with high-quality MR images as well as significant reduction of artifacts on CT scan.(ABSTRACT TRUNCATED AT 250 WORDS)
Explore the source record for details and available documents.
Aberrant left pulmonary artery, or pulmonary sling, is a rare variation of the pulmonary vasculature, with only one previous report of the condition being recognized in an adult. In this report a second case recognized de novo in an adult is presented. Both of these adults were evaluated because of right paratracheal masses which required differentiation from pulmonary malignancies. The barium swallow shows a characteristic indentation of the anterior esophageal wall and the lateral tomogram demonstrates absence of the left pulmonary artery from its normal position in the left hilum. The pulmonary arteriogram is diagnostic and allows avoidance of more invasive diagnostic measures.
Explore the source record for details and available documents.